Loading...
HomeMy WebLinkAboutW-419910rn T N i 0, m �Q rr, LLJ I� oCD (f7 Of I rr CDm o (,n U Q C-1 X C/ I U _jo J n m m � I /U� m� m QQ CV X O 0 J X c� w cn cOf o� J o] 4 Q 0 � X N O � �X /N oN 0 UI� o I CD 0 J m V) �Q � X C/)/ of o� O o O N 0- 6� 1� O J O CO o, X V) Of I 0m om O n NQ X I / �b3 N p c O y U � 6 X 390 370 360 350 340 330 STA 50+82.54, 7.28' LT FIRE HYDRANT CONNECTION '-FIRE HYDRANT ASSEMBLY 1 REMOVE EX FIRE HYDRANT ABANDON EX 8" (435 ZONE) W AFTER COMPLETION OF NEW 12" W (1)-8" CAP, (MJ) II STA 51 +10.88, 18.63' RT (1)-4" CAP, (MJ) (1)-2" TEMP BLOW -OFF ASSEMBLY (1)-THRUST BLOCK k-I)-4 UV, krLXMJ) (1)-12" GV, (FLxMJ) (1)-12" FLANGE ADAPTER (FLxMJ) (1)-THRUST BLOCK I - II 1 n I NOTES A 51 +43.28, 21.61' LT i" WATER METER 1. RESTORE UTILITY TRENCH TO EX GRADE IN ACCORDANCE WITH RMC INSTALL EX METER IN 9-10-11 TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS. W METER SETTER & METER DOCUMENT EX GRADE PRIOR TO CONSTRUCTION. IX STA 53+54.17, 6.07' LT 3 CONNECT TO PRIVATE CONNECT TO EX 8" W �3O 2. ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END(S) RVICE LINE (1)-12%8" TEE, (FLxFL) SHALL HAVE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 'A 51+50.68, 21.48' LT (1)-12" GV, (FLxMJ) 1100. WATER METER (1)-12 FLANGE ADAPTER, (FLxMJ) 3. CONCRETE THRUST BLOCKS ARE REQUIRED ON ALL WATER FITTINGS PER '.W METER SETTER & METER ABANDON EX 4" (565 ZONE) (2)-45• ROTATED BEND, (MJ) COR STD. PLANS 330.1, 330.2 AND 330.3. )X W AFTER COMPLETION OF -8 SLEEVE, (MJ) 4. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL :CONNECT TO PRIVATE NEW 12" W (1) THRUST BLOCK LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR .RVICE LINE (1)-4" CAP, (MJ) UIRED MAXIMUM JOINT SEPARATION UNLESS OTHERWISE STATED. PLACE CURB & GUTTER AND - ------ (1)46'x2' DEAD MAN ►NCRETE SIDEWALK (TYP) 2• PIPE " �" 5. WATER MAIN PIPE DEFLECTION SHALL NOT EXCEED ONE HALF OF PIPE P DEFLECTIONS - P - - - MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE. SAS SS P SS SS SSSS� 6. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT -LINED (DOUBLE Wmm w I 1 THICKNESS) DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C151 -r _ 1 AND C104 STANDARDS. JEFFERSON AVE NE w 1 -� (COMMERCIAL A ECC ECC SSA 80+0o LEGEND STA 53+65.48, 6.57' LT (1)-12" CAP, (MJ) (1)-THRUST BLOCK _ STA 53+42.41, 5.65' LT CONNECT TO EX 4" FIRE SPRINKLER SERVICE (1)-12"x4" TEE, (FLxFL) (1)4' GV, (FLxMJ) (1)-12" GV, (FLxMJ) (1)-12" FLANGE ADAPTER, (FLxMJ) �(2)- 4" 45• ROTATED BEND, (MJ) -4" SLEEVE, (MJ) _ � ,(1) THRUST BLOCK J J Q Q U_ C� O O ~ Z o I- .... W f..................W...............................W ................................................. ....................... ........................... i..... ..................................GL'J..................................................................................... ......................................... U �_ •` � i i i Q Z i � Y Z w ~ � O z 0 Z U U L�J LLICD at LiJ w Z W W W i W W " W z W W W > W �� W 0 L,J CD i> ED ED > L d N I W W Z > C) LLJ >; Q 1--..�/�...L�.......C�.... m...... m......2...................... ................................................. ............ ...................................F..L�...?....................... ....U..1—.... ....U'....1—.............................:............................... ................................................. ........................ .. .... ...................................................................................................................................................................................................................................................................................................C�......L�..U..................C....C�................................... .... ...j... ...i... LLJ EX GRADE EX DB _ _ - EX ................................................. :................................................. :................................................. :..... ........................................... :................. ........ .............. ...... ........ ......... ......................... ............. ...... ........ � _.. r....-............. 111 -GAS — N 192 LF! 28 LF 1L z ............................... ..................................................... 1.................................................:................................................,..,.. ;....................... 6 LF X 8" SS PSE P IM Y B 8L I EX8"SS: Z ` 5 LF 19 LF NEW 6" SS N .......................................................................................................................................................................................................................:.........................................:................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. 6" ETHAFOAM PAD.00 NE 10TH ST EX12"SD IN CONCRETE CASING 50+00 50+40 RECORD DRAWINGS THESE AS -BUILT DOCUMENTS HAVE BEEN PREPARED FROM THE CONTRACTOR'S REDLINED MARK-UPS OF THE CONSTRUCTION DOCUMENTS. THE ENGINEER REVIEWING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL THE ELEMENTS OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA OR CERTIFY THE ACCURACY OF THE INFORMATION PROVIDED BY THE CONTRACTOR'S AS -BUILT REDLINES. 50+80 51 +20 "00 0 10' 20' 40' 1 inch = 20 ft. HORZ 0 5' 10' 20' 1 inch = 10 ft. VERT 51+60 52+00 52+40 52+80 1 AS —BUILT 10/10/23 RVEYED: DESIGNED: BG DRAWN: DC, JYL CHECKED:- B NO. REVISION BY DATE APPR APPROVED: TJE 53+20 53+60 AS -BUILT 04199 SCALE: HORIZO�Nf� HAD 1983/11991 AS SHOWN ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 390 •e 370 360 350 340 330 W-41991 0 • CITY OF RENTON Planning/Building/Public Works Dept ROW LINE w w WATER < 12" �W�W� WATER > 12" Fs Fs FIRE SERVICE N VALVE THRUST BLOCK �i FIRE HYDRANT SLEEVE 1 • E POLYPIGGING STATION FLAG NOTES O1 EX FIRE HYDRANT TO BE REPLACED. EX FIRE HYDRANT SHALL REMAIN OPERATIONAL UNTIL NEW WATER MAIN AND FIRE HYDRANT ARE ACCEPTED AND OPERATIONAL. EX FIRE HYDRANT, FIRE HYDRANT VALVE, AND VALVE BOX SHALL BE REMOVED AFTER ABANDONMENT OF EX WATER MAIN. EX HYDRANT TO BE REPLACED SHALL BE SALVAGED TO COR WATER SHOPS. I— z LLJ 2 LU O 5� L Z_ a LLJ a W U) LL ILL z zY w�SNj'���1 W f 1q)ff � a (D • Call 811 �6, 4ISTER�'� ��`rs10NAL 1601 5th Avenue, Suite 1600 w ® two business days ���tie Seattle, WA 98101 C/) before you dig 206.622.5822 z 10/16/2023 www.kpff.com CITY OF RENTON 11/15/2022 RENTON SUNSET GARDENS SELDBOOK: z OFF -SITE WATER MAIN IMPROVEMENTS DRAWING NO: WATER UTILITY PLAN & PROFILE - C302 z JEFFERSON AVE NE (COMMERCIAL) SHEET: 0l 10 14 �