HomeMy WebLinkAboutMFP23005973.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23005973
IVR Number: 23005973
Permit Information
Permit Name: P.188718
Address/Location:11/30/2023Application Date:0823059216Parcel Number: 1107 LAKE WASHINGTON BLVD N
Permit Type:12/07/2023Issue Date:Franchise
Permit Work Class:12/06/2024Expiration Date:Minor Utility
Job Number: P.188718Franchise Type:Telephone
Description: Century Link work IN MANHOLE 326, PUSH FIBER. IN MANHOLE T 182, SPLICE FIBER TO MANHOLE T 184. IN
MANHOLE T 184, SPLICE NEW FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 1004, PUSH FIBER
CABLE. IN MANHOLE 1003, PUSH FIBER CABLE TO EXISTING FIBER CABLE . IN MANHOLE 749, PUSH FIBER
CABLE TO EXISTING FIBER CABLE. IN MANHOLE 747, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN
MANHOLE 734, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 463, PUSH FIBER CABLE TO
EXISTING FIBER CABLE. IN MANHOLE 461, PUSH FIBER CABLE TO EXISTING FIBER CABLE.
Contacts
Name Address PhoneTypeBilling
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Merilyn Luong
Lumen
B: (206) 806-7160
C: (206) 806-7160
Applicant
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
P.188718
1107 Lake Washington Blvd N
Northsky Comm
Mike Smith
12/18/2023 12/20/2023 8am 5pm
425-615-7121
Access existing MHs for splicing.
MFP23005973
VANCOUVER WA 98683-346216701 SE MCGILLIVRAY BLVD
Scott Warlick CED 12/7/2023
8:00AM - 3:00PM
Merilyn Luong
12/5/2023
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Cover Sheet
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
COVER SHEET
SHEET 1
SHEET 2
SHEET 3/4
SHEET 5
SHEET 6/7
www.invarion.comMFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: One Lane Closure
NE 27TH ST30MPH
NE 27TH ST30MPH
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
01 OF 07
Legend
Cone
Flagger
MH MH 326
Sign Stand
Work Area
2609 EDMONDS AVE NE
2616 EDMONDS AVE NE
2601 NE 27TH ST
2601 EDMONDS AVE NE
Plan Scale
1 : 600 (1'' = 50')
EDMONDS AVE NE30MPH
11/29/2023 by:
Elite Traffic Solutions206.922.9205
Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'
8'
10'
12'
50' TO 100'6 DEVICES MIN
X X X
ONE LANEROADAHEAD
W20-4
ROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1
W20-7aROAD
WORKAHEAD
W20-1
W20-7a
ONE LANEROAD
AHEAD
W20-4
ONE LANEROADAHEAD
W20-4
W20-7a
X
X
X
50' TO 300'
X
X
X
www.invarion.com
MFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Shoulder Lane Closure
N 28TH PL25MPH
N 28TH ST25MPH
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
02 OF 07
PARK AVE N25MPH
1306 N 28TH ST
2802 PARK AVE N
1215 N 28TH PL
1303 N 28TH ST
Legend
Cone
MH MH T-182
Sign Stand
Work Area
Plan Scale
1 : 600 (1'' = 50')
11/29/2023 by:
Elite Traffic Solutions206.922.9205
Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'8'
SHOULDERCLOSED
W21-5
L/3
X
X
ROADWORKAHEAD
W20-1
ROAD
WORKAHEAD
W20-1 ROADWORKAHEAD
W20-1
www.invarion.com
MFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Right Lane Closure
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
03 OF 07
N 20TH ST15MPH
Legend
Cone
MH MH 479
Sign Stand
Work Area
1300 N 20TH ST
1303 N 20TH ST
Plan Scale
1 : 600 (1'' = 50')
11/29/2023 by:Elite Traffic Solutions
206.922.9205Julian Morales
TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'
8'11'
X
ROAD
WORK
AHEAD
W20-1
ROADWORK
AHEAD
W20-1
X
X
ROAD
WORK
AHEAD
W20-1
X
X
X
RIGHT LANE
CLOSEDAHEAD
W20-5
RIGHT LANECLOSEDAHEAD
W20-5
BIKESMERGE WITHTRAFFIC
W4-1b
BIKE
LANE
ENDS
W9-1b
X
X
W1-4
W1-4
LEFT LANECLOSEDAHEAD
W20-5
W4-2
X
X
X
L
L/2
B
LAKE WASHINGTON BLVD N25MPH
www.invarion.com
MFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Right Lane Closure
L
A
K
E
W
A
S
H
I
N
G
T
O
N
B
L
V
D
N
2
5
M
P
H
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
04 OF 07
Legend
Cone
Flagger
MH MH 747
Sign Stand
Work Area
2100 LAKE WASHINGTON
BLVD N
Plan Scale
1 : 600 (1'' = 50')
BELLA VISTA
LAKE WASHINGTON
APTS
11/29/2023 by:Elite Traffic Solutions
206.922.9205
Julian Morales
TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'
8'
50' TO 100'
6 DEVICE MIN
11'
50' TO 100'
6 DEVICES MIN
50' TO 300'
X
ROADWORK
AHEAD
W20-1
ROADWORK
AHEAD
W20-1
X
X
W20-7a
W20-7a
ONE LANE
ROADAHEAD
W20-4
ONE LANEROAD
AHEAD
X
X
X
www.invarion.com
MFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Shoulder Lane Closure
LAKE WASHINGTON BLVD N25MPH
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
05 OF 07
Legend
Cone
MH MH 734
Sign Stand
Work Area
RESIDENCE INN BY
MARRIOTT SEATTLE
SOUTH/RENTON
Plan Scale
1 : 600 (1'' = 50')
HAMPTON INN &
SUITES/RENTON
1322 LAKE WASHINGTON
BLVD N
11/29/2023 by:Elite Traffic Solutions
206.922.9205
Julian Morales
TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'
8'
L/3
ROAD
WORKAHEAD
W20-1
X
X
ROAD
WORK
AHEAD
W20-1
50'NO P ARK24 HRSNOPARKINGFROM
TO
TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
R7-T39
SHOULDERCLOSED
www.invarion.comMFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan: Right Lane Closure
SOUTHPORT DR N 30MPH
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
06 OF 07
Legend
Bus Stop
Cone
MH MH 461
Sign Stand
Traffic Light
Work Area
GRIFFIS LAKE
WASHINGTON
Plan Scale
1 : 600 (1'' = 50')
1000 GARDEN AVE N
LAKE WASHINGTON BLVD N25MPH
11/29/2023 by:
Elite Traffic Solutions206.922.9205
Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'
8'
ROAD
WORK
AHEAD
W20-1
X
X
X
RIGHT LANECLOSEDAHEAD
W20-5
W4-2
ROAD
WORK
AHEAD
W20-1
W4-119 (L)
www.invarion.com
MFP23005973
Imagery and map data ©2023, Google
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
KingP.188718 98057
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS
PER MUTCD)
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Scope of Work: Manhole Access
Traffic Control Plan:Alternating Lane Closure w/ Flaggers
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 48 x 48 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
07 OF 07
Legend
Cone
Flagger
MH MH CB0 1
Sign Stand
Work Area
WIZARD OF THE
COAST LLC
Plan Scale
1 : 600 (1'' = 50')
1000 GARDEN AVE N
LAKE WASHINGTON BLVD N25MPH
1101 LAKE WASHINGTON
BLVD N
920 LAKE WASHINGTON
BLVD N
11/29/2023 by:Elite Traffic Solutions
206.922.9205
Julian Morales
TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
MH
35'8'50' TO 100'
6 DEVICES MIN
ROAD
WORKAHEAD
W20-1
X
X
X
ONE LANEROAD
AHEAD
W20-4
W20-7a
X
X
X
ROADWORK
AHEAD
W20-1
ONE LANEROADAHEAD
W20-4
W20-7a
50' TO 300'
www.invarion.com
MFP23005973
Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be determined by City of Renton.
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Legend
Arrowboard (Chevron)
ConeSSpotter
truck
Work Area
TRAFFIC CONTROL PLAN
JOB # N.991223 C.45
PERMIT #
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
NOT TO SCALE
Sharon Martos
Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com
UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com
LAKE WA BLVD N @ HOUSER WAY N
MH 463
RIGHT LANE CLOSURE
SPEEDLIMIT
25
Comments:
ACCESS MH 463.WEST SIDE LAKE WA BLVD N, SOUTH OF HOUSER WAY N.
RIGHT LANE CLOSUREBIKES MERGE WITH TRAFFIC.
SIDEWALK CLOSED.CURB RAMPED PER ADA REQUIREMENTS TO
ACCOMMODATE PEDESTRIANS.
SPOTTER WILL ASSIST PEDESTRIANS.RRDETOURM4-9bDETOURM4-9bMH 463
WORK AREA
10 X 155
S W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1100'100'100'105'
LAKE WA BLVD N
HOUSERW
A
Y
N100'Nwww.invarion.com
MFP23005973
Additional approval
may be needed from
BNSF for work in
their ROW
Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be determined by City of Renton.
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Legend
Cone
S Spotter
truck
Work Area
TRAFFIC CONTROL PLAN
JOB # N.991223 C.45
PERMIT #
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
NOT TO SCALE
Sharon Martos
Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com
UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com
LAKE WA BLVD N @ BURNET T AVE N
MH 1003
SHOULDER WORK
SPEEDLIMIT
25
S
MH 1003
WORK AREA8 X 40
ROADWORKAHEADW20-1SHOULDERWORKW21-5100'ROADWORKAHEADW20-1DWY
LAKE WA BLVD N
DWY BURNETT AVE NComments:
ACCESS MH 1004.
WEST SIDE LAKE WA BLVD N, SOUTHOF BURNETT AVE N.
SHOULDER WORK.BIKE LANE ACCESSIBLE.
SPOTTER WILL ASSIST PEDESTRIANS.Nwww.invarion.com
MFP23005973
Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be determined by City of Renton.
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Legend
Cone
S Spotter
truck
Work Area
TRAFFIC CONTROL PLAN
JOB # N.991223 C.45
PERMIT #
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
NOT TO SCALE
Sharon Martos
Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com
UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com
LAKE WA BLVD N @ BURNET T AVE N
MH 1004
SHOULDER WORK
Comments:
ACCESS MH 1004.
WEST SIDE LAKE WA BLVD N, SOUTHOF BURNETT AVE N.
SHOULDER WORK.BIKE LANE ACCESSIBLE.
SPOTTER WILL ASSIST PEDESTRIANS.
SPEEDLIMIT
25
S
MH 1004
WORK AREA8 X 40
ROADWORKAHEADW20-1SHOULDERWORKW21-5100'DWYROADWORKAHEADW20-1LAKE WA BLVD N
BURNETTAVENNwww.invarion.com
MFP23005973
Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be determined by City of Renton.
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Legend
Cone
S SPOTTER
Work Area
Work Truck
TRAFFIC CONTROL PLAN
JOB # N.991223 C.45
PERMIT #
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60NOT TO SCALE
Sharon Martos
Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com
UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com
PARK AVE N @ N 28T H ST
MH T-182
SHOULDER WORK
Comments:
ACCESS MH T-182SOUTH SIDE N 28TH ST @ PARK AVE N.
SHOULDER WORK.SPOTTER WILL ASSIST PEDESTRIANS.
N 28TH STPARK AVE NN 28TH PL
ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1NSPEEDLIMIT
25
100'
MH T-182
WORK AREA
10 X 40
S
www.invarion.com
MFP23005973
Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be determined by City of Renton.
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Legend
Cone
Flagger
Work Area
Work Truck
TRAFFIC CONTROL PLAN
JOB # N.991223 C.45
PERMIT #
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
NOT TO SCALE
Sharon Martos
Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com
UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com
BURNETT AVE N @ N 28TH PL
MH T-184
ONE LANE 2-WAY Comments:
ACCESS MH T-184.
WEST SIDE BURNETT AVE N
@ N 28TH PL.
ONE LANE 2-WAY WITH FLAGGERS.
FLAGGERS WILL ASSIST PEDESTRIANS.ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aR
O
A
D
W
O
R
K
A
H
E
A
D
W
2
0
-1
B
E
PR
E
P
A
R
E
D
TO
S
T
O
P
W
2
0
-7b W2
0
-
7
a
N 27TH PLN 28TH PLN 29TH STALLEYROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1ROADWORKAHEADW20-1BE PREPAREDTO STOP
W20-7b
W20-7a100'
100'
BURNETT AVE N
ROADWORKAHEAD
W20-1
SPEEDLIMIT
25
MH T-184
WORK AREA
10 X 90
100'
100'
100'100'Nwww.invarion.com
MFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.14400000000”NVICINITY MAPFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMSCOPE OF WORK:LSH24, 17-18. IN MANHOLE 326, PUSH LSH24, 17-18 FROM EXISTING FIBER CABLE [QD68] TO EXISTING FIBER CABLE [QD67]. IN MANHOLE T-182, SPLICE FIBERCABLE [QD67] TO NEW FIBER CABLE BEING PLACED APPROX. 1440' THROUGH EXISTING CONDUIT TO MANHOLE T-184. IN MANHOLE T-184, SPLICE NEWFIBER CABLE TO EXISTING FIBER CABLE [TTP6]. IN MANHOLE 1004, PUSH FIBER CABLE [TTP6] TO EXISTING FIBER CABLE [TTN3]. IN MANHOLE 1003, PUSHFIBER CABLE [TTN3] TO EXISTING FIBER CABLE [TTN2]. IN MANHOLE 749, PUSH FIBER CABLE [TTN2] TO EXISTING FIBER CABLE [TTN1]. IN MANHOLE 747,PUSH FIBER CABLE [TTN1] TO EXISTING FIBER CABLE [A3DAQ]. IN MANHOLE 734, PUSH FIBER CABLE [A3DAQ] TO EXISTING FIBER CABLE [A3DEL]. INMANHOLE 463, PUSH FIBER CABLE [A3DEL] TO EXISTING FIBER CABLE [TTM9]. IN MANHOLE 461, PUSH FIBER CABLE [TTM9] TO EXISTING FIBER CABLE[A3LNZ]. IN CBO1, PUSH FIBER CABLE [A3LNZ] TO EXISTING FIBER CABLE [A3LPF]. IN ACCESS POINT, PUSH FIBER CABLE [A3LPF] TO EXISTING FIBER CABLE[A3LP5].FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057112RMFP23005973
TTEE CATV
CATV
CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L
R/W R/W R/W P/L P/L B/C B/C B
/C
EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057212RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W
R/W
R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W T35'6'2632#04230591392609#3343900041#04230593042424#334390000516'42'28'27'30'29'32'NOTE:LSH24, 17-18. IN MANHOLE 326, PUSH LSH24,17-18 FROM EXISTING FIBER CABLE [QD68] TOEXISTING FIBER CABLE [QD67].SPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057312RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSMATCH SHEET 5
EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T24'24'26'26'24'12'1215#3342100725164450TR-B1303#05230590561307#0523059060#33421033011306#3342103285NOTE:1400' OF NEW48F IN EX UG.NOTE:IN MANHOLE T-182, SPLICE FIBER CABLE [QD67]TO NEW FIBER CABLE BEING PLACED APPROX.1440' THROUGH EXISTING CONDUIT TOMANHOLE T-184.SPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057412RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP
EOP R/W R/W R/W
R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP EOP R/W R/W R/W EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP R/W R/W R/W T905#3342100615900#16445002802807#33421005802803#3342100595#062305900122'15'32'30'18'30'MATCH SHEET 4 NOTE:IN MANHOLE T-184, SPLICE NEW FIBERCABLE TO EXISTING FIBER CABLE [TTP6].SPEEDLIMITSPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057512RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP
EOP
EOP
EOP
EOP
R/W
R/W
R/W
R/W
R/W
R/W
R/W
EOP
EOP
EOP
EOP
EOP
R/W
R/W
R/W
R/W
R/W
R/W R/W
R/W
R/W
R/W
R/W R/W
R/W R/W R/W TT#0523059003#2296500185#22965001804'4'NOTE:IN MANHOLE 1004, PUSH FIBER CABLE [TTP6] TOEXISTING FIBER CABLE [TTN3]. IN MANHOLE 1003,PUSH FIBER CABLE [TTN3] TO EXISTING FIBER CABLE[TTN2].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057612RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MANHOLE 749, PUSH FIBER CABLE[TTN2] TO EXISTING FIBER CABLE [TTN1].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057712R EOP
EOP
EOP
EOP
EOP
R/W
R/W
R/W
R/W
R/W
R/W R/W
R/W
R
/W
R/W
R/W
R/W
R/W
R
/W
R/W
EOP
EOP EOP EOP T55'30'33'3'6' S/W20'49'60'3'SPEEDLIMIT#05230590031303#33445003151303#3344500315MFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS1400#33445000390NOTE:IN MANHOLE 747, PUSH FIBER CABLE [TTN1]TO EXISTING FIBER CABLE [A3DAQ].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057812R EOP
EOP
EOP
EOP
EOP
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
EOP
EOP
EOP
EOP
EOP T24'35'25'4' GRASS6' S/W11'175'#0523059003MFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS1322#3344500005NOTE:IN MANHOLE 734, PUSH FIBER CABLE[A3DAQ] TO EXISTING FIBER CABLE [A3DEL].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057912R EOP
EOP EOP EOP
R/W R/W R/W R/W
R/W R/W
EOP
EOP EOP EOP
R/W R/W R/W R/W R/W R/W T24'34'33'25' PARKING420'TOHOUSERWAY4' BIKE LANE#3344500007MFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EO
P
EOP
EOP EOP EOP
T R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 3'135'6' S/W55'48'#08
2
3
0
5
9
0
2
7
#082
3
0
5
9
1
9
1
NOTE:IN MANHOLE 463, PUSH FIBER CABLE[A3DEL] TO EXISTING FIBER CABLE [TTM9].SPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571012RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSH
IP
P
ING
Y
ARDT
E
O
P
EOP EOP R/W R/W R/W R/W EOP EOP PWR STATION BOEINGNOTE:IN MANHOLE 461, PUSH FIBER CABLE[TTM9] TO EXISTING FIBER CABLE [A3LNZ].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571112RMFP23005973
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN CBO1, PUSH FIBER CABLE [A3LNZ] TO EXISTINGFIBER CABLE [A3LPF]. IN ACCESS POINT, PUSH FIBERCABLE [A3LPF] TO EXISTING FIBER CABLE [A3LP5].TTO
L
A
K
E
W
A
S
H
I
NG
TO
N
B
L
V
D
N 111111071103SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571212RMFP23005973