Loading...
HomeMy WebLinkAboutR-394925M i 0 W U N U) Ln N z O w w w w r-, J w Q M N O N O n 0) 0 U) N N Ln a) a� V) Q U i N v7 (0 L a a 0 0 ry Ln N N i 00 Ln U FI w so 1 40 1 35 1 30 1 25 1 20 1 15 1 10 5 � a I o I' I l CD CB 18707 (141563 \ w RIM 30.76 I °- - - . I IE 29.1 W, 8 PVC 695 (178159) \ \ I ' �� \� T GB 1'8710 (1400 - ° M 30.93 CB 184 5 (113735) II ° IE �g;7 E'a.8" P4'VC, ,I CB 18485 (113734) \ I IE 25.9 SW, 12" HDPE RIM 30. 7 I I IE 28.3'NW, 8" PVC STA C8+39 21.0' LT 11 112 IE 21.6 SE, 12" METAL IE 2 .4 S, 8" CONC STA C5+33 20.9' LT I 112 a o,a . a , I < IM 31.12 O _ O IE 17.8 NE, 48 METAL 1-CB # 13 11 I IE 29.8 S, 8" CONC I 1 CB # 15 IE 17.8 NW, 48" METAL I l ��. I' IE(OUT)12"(S)=27.13 IE(OUT)12"(S)=27.50 O I �I 187 8 (No ID b STA C6+85 21.0' LT 11 1 0 RIM'31.1 ° � ,.° I w Pvca 1-CB #14 -xi` I a ° I IE(OUT)12"(S)=26.57 STA C8+39 13.5' LT , STA C4+90 13.6' LT STA C5+33 13.7' LT _ _ _ > - - as - - - - �- as � - 12 1-48" SDMH #9 12 1-48" SDMH #10 0 � - - - ' ~ � � � 1-48" SDMH #12 ' � R .HALLS33125 (1 27 27 p 3 i d0lS - P --C7 - TO 0 a C STA C6+85 13.0 LT 12 a NE.WAY Q O -T --T GP- �� G -.--------U�P== _= Gp= _ a4 P- Ada--UGa --. P--1-48"SDMH#11 �IGP-- �- -3-- �_�� 0 l0 Erl -44 24 - - - - - - - - - - - - 25 - - I I 26 4 U 12"C900 SD 12"C900 SD J" 1 `� 1 1 12�'C900 SD 1 1 12"C900 SD Q o 15 „ ,I, ,_ I S3RDST TYP ____ I - w - - 12 W DI - - - - 1 I W DI - - - - - 12"W DI - - - - - 12''WkDI - - - 12 W D - - - - - 12"W DI -� - -I - 12'W DI - - - - - 12 W DI - - - - - 12"W DI - - 12"W DI - - - - 12"W DI - - - - 12"W 12''W DI - - 12"IW DI - - - - F- � C5+00 C6+00 C7+00 C8+00 �2 C9+00 � w �,�- .:I .... ... .-r. j .�- -., AT - . .- .,�A ._ - �-� - . i . r I - .}.�.. �� -1.- +- .-I .--. ,�;T .� �. ; �.� _. - I� .+.� .� � .� " �. W = ... \ • • • .. 24" C900 SS I I 24" C900 SS - I Z Ln I w I® \� I G � G � G G I � G G G G � ® 82 � G G =� 31 I I I f T T T ° I f T U I I I _ - KB-16 _ - _ - _ - - - ® - uG ° - _ ° a -r -° -- -U U 0 RIM 31.06 t �E 2 C SDMH 18144 (135877) 1-�71',METAL.POST IE 23.3 E, 8" CONC � RIM 31.36 l-G IE 23.1 NW, 12" METAL IE 26.2 N, 8" CONC CB RIM IE 24.9 E, 8" CONC YD 26457 , IE r I , IE 24.6 W, - CONC ' RIM 31.74 r ' IE 300 I 107 111 115 IE ':0 E, 3" PVC 125 ; RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND I ELEVATIONS. THE ORIGINAL DESIGN PLAN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO 0 10 20 40 60 CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SCALE: 1"=20' 'I CONSTRUCTION NOTES: O CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 11 INSTALL CB PER COR STD PLAN 200.00 12 INSTALL CB PER COR STD PLAN 201.00 15 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE 24 INSTALL 5 LF OF 12-IN PP PIPE AT SLP=1.6% 25 INSTALL 5 LF OF 12-IN PP PIPE AT SLP=1.2% 26 INSTALL 5 LF OF 12-IN PP PIPE AT SLP=2.2% 27 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION (D N _ � EXIST GR @ �! u u- U) w X w w ROW CL w w w o l0 0 0 0 m Q 00 154 144 LF 12" C900 @ SLP=0.45% U-) LF 12" C900 @ SLP=0.48%o 153 LF 12" SLP=0.53% C900 (a)w (� w 42 LF 12" C900 W w @ SLP=0.47% U) 48" SDMH #11 STA C6+85, 13' LT 48" SDMH #12 ww 48' SDMH #10 STA C8+39, 14' LT = STA C5+33, 14' LT RIM=31.38 RIM=31.74 U RIM-31.16 IE(IN)12"(E)=23.93 IE(IN)12"(E)=24.65 ~ IE(IN)12"(E)=23.09 IE(IN)12"(N)=26.33 IE(IN)12"(N)=26.98 Q 48„ SDMH IE(IN)12"(N)=27.50-�8 IE(OUT)12"(W)=23.90 IE(OUT)12"(W)=24.67 STA C4+90, 14' LT IE(OUT)12"(W)=23.07 RIM=31.23 i!2.3 IE(IN)12"(E)=22.87 22 -F- IE(OUT)12"(NW)=22.83 (RECONNECT) IE(IN)12"(SE)=22.83 (RECONNECTED) C4+80 C5+00 C5+20 C5+40 C5+60 C5+80 C6+00 C6+20 C6+40 C6+60 C6+80 C7+00 C7+20 C7+40 C7+60 C7+80 C8+00 C8+20 C8+40 C8+60 C8+80 C9+00 C9+20 C9+40 C9+60 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY REVISION NOTICE SEO RECORD 0 /Z 1 DESIGNED DRAWINGS BAW DRAWN MUrraYSMirth IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE i RENTON DOWNTOWN � UTILITY IWO IMPROVEMENTS PROJECT 35 30 25 20 15 10 E S3RDST STORM PLAN & PROFILE STA C4+80 TO STA C9+60 PROJECT NO.: 18-2251 1 SCALE: AS SHOWN I DATE: JANUARY 2021 R-394925 SHEET SD-7 25 of 121