Loading...
HomeMy WebLinkAboutR-394930O� rn Co O Lu U N z O ry w LL LL w J w Q M N O N O TV 0 0, 0 U) N N a� a� v7 Q i N a� r° a a 0 C 0 s= ry Ln N N i 00 U �I w 1 35 1 30 1 25 1 20 1 15 1 10 5 SEE SHEET SD-8 FOR CONTINUATION CB 26961 30.96 IE 27.4 W, 12" CMP IE S 27.4 , 12" METAL � I CONC MON IN CASE REESTABLISHED CB 2.4 S, RIM 6852 PER DNR PERMIT 7373 - 18 Tx6 W 0.83 IE 26.4 E, 12" CPP I IE 26.5 N, 12" CONC II 301 IE 26.2 W, 12" CONC I M I I 12 STA F 10 + 01 18.2' LT 1-CB #53 W/RECTANGULAR FRAME & VANED GRATE AT&T CRITICAL SSMH 26850 I (� �' CB #19 SEE SHT SD-8 CB 69591 FIBER OPTIC, RIM 30.7E CUSHION PER THE CHANGED TO TYPE 1 CB PROTECT IN PLACE RIM 0.00 I CB 70375 IE -8.6 N,E,S ® C 4 I I SSMH 26851 awl CB 6897E RIM 31.22 RII 2 12" CONCI IE 23.E E,W - 1 ®j WE •° i ss I e I SEE DET 2, SHT SD-45 � I STA F7+73 21.3' LT 12 1-48" SDMH #56 W/ RECTANGULAR FRAME & VANED GRATE I PLACE DENSE FOAM • lie 'j 01 • 28.8 • .� ` ' • 1 BETWEEN ` • ® . ■ 1 RIM IE " 1 . , REPAIRED EXIST FRAM : ' ` RIM 29.73 - - .�ME I , .RIM IE 26.8 S, • 6" CONC 1. • A C- AC 11 �-J& AC CLAY SS LATERAL :: PVC @ .. i .:eo7 n 11 • CI:111 OVA Oil-Jt� _� , .� AMil A-mm I • 12"W PLACE PER 1-07.17 • • � Wx�= - U00 �• �� 1 .. ••'SD O24" PP • •PON • SDMH #16, SEE SHT SD-8/ - 13 22 1-CB #44 , I I P - P- -3' - - - U / SPi CB # 18, SEE SHT SD-8i SSMH 69595 CON FILL E CB 70005 I SD 2669 1 RIM .6 N 13 RIM 29.69 a IE 22.E N,S � cL I I STA F10+01 15.2' R 12 IE 28.1 SE, 4" PVC STA F5+98 10.9 RT RI 30.74 1 IE 28.4 SE, 4" PVC a 12 IE 22.1 N,S, NW IF 22.8E IE 28.4 NW, 4" PVC I I Q 1-48 SDMH #15 IE 26.4 , 12" CONC CB 69599 STA F7+70 11.9' RT 3 1-48" SDMH #35 SDMH 25291 - 338) \ II RIM 30.12 12 SDMH 69907 I RI 7 9,75 1 ® RIM 29.73 TIED INTO EXIST CB IE 26.5 S, 6" CONC IE 29.3 N, 6" CONC 1-48" SDMH #33 RIM 30.69 RIM 30.88 IE 27.3 E, 12" CONC IE 21.8 N,S, 12" CONC I I I M IE 27.3 NE, 6" CONC IE 25.4 NE, 12" METAL STA F5+89 15.E RT c� IE 25.8 W, 12" CMP a 1-48" SDMH #14 12 CI 21.3E F IE 23.5 E, 12" CONC I I � SDMH 25292 L J IEM27.83N, 12" METAL 1 STA F7+70 20.6' RT I RIM 31.01 1 j IE 27.8 W, 12" METAL 1 1-CB #42 11 13 STA F9+60 28.0' R IE 25.9 E, W, 12" CMP STA F9+24 15.1 R o �E_2�.2.SrlZtadEtAL STA F5+86 21.1' RT 11 a SDMH 25290 12 �� z 1-CB #46 1-60 SDMH #34 I I � 1-CB #17 IM 30.96 SDMH 25300 I I 3: I a RIM 31.01 zIE 27.6 SE, 8" CONuCulNu IE 25.9 E, W, 12" CMP al- I W f- IE 22.8 ELf), W/THROUGH PIPE, 12" CONC I IE 27.2 S, 12" METAL ACI + II / a IE 27.0 NW, 6" METAL CB 25293 I I I I (n CB 25298 P LA N RIM 30.65 I O RIM 30.76 207 220 I IE 26.2 E, 12" CMP I I o \ IE 28.7 E, 12" METAL 0 10 20 40 1 60 8 CON oo ,1 SCALE: 1"=20' u) Q !I, kI Ln rnl rn 12I n z r� 0 aim CONSTRUCTION NOTES: (DCONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 11 INSTALL CB PER COR STD PLAN 200.00 12 INSTALL CB PER COR STD PLAN 201.00 13 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE 1s CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE 16 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS 18 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION 19 SEE PROFILE 6 ON SHT SD-42 20 SEE PROFILE 7 ON SHT SD-42 21 SEE PROFILE 8 ON SHT SD-42 22 SEE PROFILE 1 ON SHT SD-43 �p SEE PROFILE 2 ON SHT SD-43 24 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY, IF CONFLICT PREVENTS INSTALLATION OF A TYPE 1 CB, CONTRACTOR SHALL INSTALL A SHALLOW CONCRETE INLET WITH ENGINEER APPROVAL PER COR STD PLAN 200.3 AT NO ADDITIONAL COST TO THE CITY 27 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION a m �' �= U�N U) co a �Q m O a 5 a Lu N i� w �� w (D U ��O X cn Ln En O 0 w a ww w w ww w a w ww w~ ROW CL w w � (n w X w 13 LF 18" PP SD @ ----- - -- - - --- --- SLP=0.23% - ---- --- _ ____ 10LF18"PP SD@ 8 ° SLP=1.75% 0 0 O ° a00000 ° 8 + 0 LL kD 0 v) + Ln 0 (n w LLO Lu Lu � z ' 108 LF 24" PP SD @ SLP=0.30% „' Lr 24" � ~ 154 LF 24" PP SD @SLP-0.65% - - 389i 77 LF 24" PP SD @ SLP=0.18% = cwn w W 48" SDMH #15 �° U = z STA F5+98, 11' RT 48" SDMH #16 RT,� RIM=31.12 2-69 -IE(IN)18"(NW)=21.58 SEE SHT SD-8 48" SDMH #33 STA F7+70, 12' RT ' 60" SDMH #34 STA F9+24, 15' RT Q = U z2+.69 IE(OUT)18"(S)=21.58 RIM=30.70 - RIM=30.65 48" SDMH #14 IE(IN)24"(N)=20.49 zz6-.6B 2 6-.+8 IE(IN)24"(N)=19.46 Q STA F5+89, 16' RT IE(IN)12"(W)=25.07 254 & IE(IN)12"(NW)=26.98 48" SDMH #35 RIM=31.03 64 LF 18" PP SD @ IE(IN)12"(E)=23.64 23-5& IE(IN)12"(E)=22.85 STA F10+01, 15' RT RIM=30.13 IE(IN)18"(N)=21.76 SLP=0.14/o o IE(OUT)24"(S)=20.46 28.63r 26--Ad IE(IN)12"(S)=26.19 IE(IN)24"(N)=19.60 +9.84 21-Fi! IE(IN)12"(S)=21.85 8.33% 2848 IE(OUT)24"(S)=19.46 IE(IN)12"(E)=20.06 28..i4 26--88 IE(IN)12"(NW)=27.09 �� - IE(OUT)18"(SE)=21.76 IE(OUT)24"(S)=19.58 +9.84 F5+60 F5+80 F6+00 F6+20 F6+40 F6+60 F6+80 F7+00 F7+20 F7+40 F7+60 F7+80 F8+00 F8+20 F8+40 F8+60 F8+80 F9+00 F9+20 F9+40 F9+60 F9+80 F10+00 F10+20 F10+40 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY NOTICE SEO RECORD 0 Yz 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE • RENTON DOWNTOWN o UTILITY '� IMPROVEMENTS PROJECT 40 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO 35 CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 30 25 20 15 10 5 SHATTUCK AVE S STORM PLAN & PROFILE STA F5+60 TO STA F10+40 R-394930 SHEET SD-16 30 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021