HomeMy WebLinkAboutW-3949220) C'7 N U a) V) J rl N z O LJJ LL LL LJJ J LJJ a N N O M N O N O I 0) 3 I O w 0 I I a I Ln N N I Ln a) a) Q N a) Ln ra a a 0 0 a� Ln N N i 00 U a) L a �I w TOTAL SF OF BEARING SURFACE NEEDED FOR TEMPORARY THRUST RESTRAINT USING ECOLOGY BLOCKS TOTAL WEIGHT OF ECOLOGY BLOCKS (LBS) 31600 71200 101800 141400 181000 211600 z 4 1 - - - - - Lu , 6 5 2 - - - - "' 8 10 8 5 3 - - W 12 - 23 20 18 15 13 1. CONTRACTOR TO CONFIRM UNCONFINED COMPRESSIVE STRENGTH OF SOIL IS AT LEAST 500 PSF. 2. TEMPORARY THRUST RESTRAINT UTILIZING ECOLOGY BLOCKS BASED ON TOTAL SYSTEM PRESSURE AND WATER HAMMER PRESSURE OF NO GREATER THAN 120 PSI. THIS TABLE SHOULD NOT BE USED FOR NEW MAIN WITH TEST PRESSURES HIGHER THAN 120 PSI. 3. SHIMS AND/OR GROUT SHALL BE PLACED AS NECESSARY TO FILL VOIDS BETWEEN RESTRAINED JOINT CAP, ECOLOGY BLOCKS, AND UNDISTURBED SOIL. 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY NOTICE JAM 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE NnTFc 1. BEARING SURFACE 2. TYPICAL ECOLOGY BLOCK (2x2x6) 3. TEMPORARY RESTRAINT JOINT CAP 4. EXISTING WATER MAIN TO REMAIN IN SERVICE 5. SHIMS TO BE PLACED BETWEEN CAP AND ECOLOGY BLOCK AS NEEDED 6. GROUT TO BE PLACED BETWEEN ECOLOGY BLOCK AND UNDISTURBED EARTH AS NEEDED TO PREVENT SLIDING OF THE ECOLOGY BLOC 7. TYPICAL TRENCH 8. PROPOSED WATER MAIN 9. THRUST BLOCK TO FOLLOW STD 330.2 10. 2" TAP AND TEMP WATER SERVICE RECORD DRAWINGS SEE NOTE ON murraVSMi mt COVER SHEET EA 0 TOP SECTION VIEW NOT TO SCALE i_ 18" _i 10 8" 2'-0" 1'-6" 1'-6" 1'-6" 2 10" 2'-6" 1'-6" 1'-6" 1'-6" 2 12" 2'-6" 2'-0" 1'-6" 1'-6" 4 16" 3'-0" 2'-6" 2'-0" 1'-6" 4 NOTES: ' 1. CONCRETE SHALL 3000 P.S.I. READY MIX POURED IN PLACE. 2- REINFORCED BARS SHALL BE DEFORMED BARS AND TIED TOGETHER. 3. FORMWORK AT FACE OF ANCHOR WALLS MUST BE REMOVED. BACKFILL AT FACE OF ANCHOR WALL MUST BE COMPACTED TO 95X MAX DRY DENSITY BASED ASTM D1557 PRIOR TO REINSTATING SERVICE OF THE WATER MAIN. E. IN, I MAXIMUMN. ELEVATION VIEW Y arr + PUBLIC WORKS CONCRETE DEADMAN BLOCK � ` DEPARTMENT RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT #4 REBAR AT 8" ON CENTER WITH 180' STANDARD HOOKS ® BOTH ENDS RECOMMENDED POLYPIGGING AND DISINFECTION PLAN START CONNECTION DETAIL END CONNECTION DETAIL rA W-40 rA W-1 rD W-40 rD �-3 rN"'� W-43 N ��3 rG W-41 rG W-16 D �W-40 D �-3 E W-41 rE W-19 rK**�� W-42 rK W-25 rL W-42 L W-26 rL W-42 L W-25 M W-42 M W-26 POLYPIG PLAN AND TEMPORARY THRUST BLOCKING PROJECT NO.: 18-2251 1 SCALE: AS SHOWN I DATE: JANUARY 2021 W-394922 SHEET W-44 94 of 121 REVISION