Loading...
HomeMy WebLinkAboutS-39491011••. N U V) U) N z O Ln IL IL w r, J w a O M M N O N 0 Ln U) a U) N N a� a� V) a U N Q) ro a a 0 c 0 c Ln N N i 00 Ln w U L �I w 50 45 .M 35 30 25 20 15 SDMH 67580 RIM 36.83 IE E, 6' CONC IE 30.8 N, 24" CMP IE 30.6 S, 24" CMP IE 32.8 W, 12" CPP CB 67576 RIM 36.43 IE 33.5 E, 12 UFF WOOD DECK UNKNOWN CONNECTION uu I you uq uu u 4 uu - --T- -- T-I-I--+� 1-- ss. 10 STA A19+95 5' LT_ - SS - _G_ SSMH#11 G1 1 1-48" MA M H ...-. SS .-.- -.: ss -�- �- - - - - - - - - I I I----A20+00� . . . . . . I CRPL #3 66" STL I ICI 1 .5/t- -------------- - 15 -----12"STAA19+90 2'LT-- - 121'WWTDI- CPJB #7 d I I 1 I COORDINATE CP STRUCTURE LOCATION WITH I I ENGINEER AS NEAR AS PRACTICAL TO THE EDGE OF RESTORATION EXTENTS Cn 1 SDMH 67608 w uJ I RIM 36.81 IRT \ /� IE 32.2 S, 18" CMP IE 31.4 E, 24" CMP SPIKE 102 , IE 31.4 N, 24" CMP z I IE 33.9 SW, 8" METAL I Qi 1 L / (� I SSMH 67820 �I IE 30.3 N S @ CL ® �I SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION AT OF CO OR CPLG MAIN 526 S 2ND N' NIC ST E: 205 LOGAN NIC N' AVE S E: B 67579RIM 36.48 I N, I IM34 9 W, 6" CONC I cn U) SSM 11722 t W► SMH 67611 SSMH #32, U) � RIM 38.40 SEE SHT SS-22 I IE 2.1 S,E-W @ CL 12" CONC _ IM 37.06 150 E27.9E,W@CLI Aft IE 30.4 S I I I ' KING COUNTY INTERCEPTOR cTL . ' 12'x8.5' � I IE 30.3 Ni TIE-IN, SEE DE T SHT SS-40 C 51x6' \ J) CB 11711 IE 29.2 SW CB 67741 UCT I RIM 37.88 RIM 37.70 ` IE 36.5 W, 6" CONC SSMH 67610 IE 33.9 NE, 6" CONC DUCT 13 9 IE 36.5 E, 6" CONC tE 29•.9 E,' W @ CL ` SSMH 11881 ` \ DU T UCT � IE '30.2'N T \ I \ 1 SSMH 12322 • ' RIM 38.02 v� tE 30.2 S' IE 29.7 SE-W @ CL 18" CONC � T _ N c) I RIM 31.73 . IE 30.0 E, 8" ABANDONED - - x ll IE 32.0 S,E-N @ CL 12' CONC - - - - �DUC� �'�I ln I T DUCT -_ =-T T -T _ T---- T-=-T=-=UG T= G _ T----T `oo �- -- UG _ -- DUCT I DUCT x- - - cU) AT&T HH 463 --��- -T----- T----- T----- T--i�DUCTT -- --T-- DUCT ---- , DbT DUCTN. _ T- --- I T TI I i - SS - - - - - SS - - - - - SS S 2ND ST - - -- S-----SS -_, -- T- -T-- ��------ LT___ I 1I c�STAA23+25 2'LT_ DUCT - - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTL MH, � 5'x12'x8.5' 15 T r - G- - - - - G- - - - - G- - - - - G- - - - - G- - - i.� .- G- - - - G- -.- -•-•� - - - - G- - - I �G8 _ _ 11 CPJB #8 �. s° . 8" C900 SS � _ _ G I COORDINATE CP STRUCTURE LOCATION nrAug CE R 2"PVC CONDUIT 4 WITH ENGINEER AS NEAR AS PRACTICAL TO A21+00 APPROXIMATES` $ A22+00 W A23+00� - A23+40 THE EDGE OF RESTORATION EXTENTS ��----- - - - - - - - - - - - - - - - - - - - - �------------------- - - - - - - L- __ ________ --'-_ _ 1 CRPL #3 66' STL � # STL CRPL #3 66" STL � � � - - --------- _ ------------ --- SD-----SD SD - - - - - SD - - - - Sp ------ -------------- -- --SD -SD �-12"W DID----12" DI-�---12"W I---12"W ---- Sa��---SD - - -- 1 a -12" DI - -- 1-2W DI - -- SD12"W 1- - 12"W �-- ----_ PIKG - P _ - '-- - _ _ U = UGP = = � - GP- - II -- - P - - = �G - I T I ��` - UGP- - - - _U P P , 82 UO I 3$ SDMH 12317 �� r LLJ RIM W-NW: 12" CONC E W; 18 C C NW O_ E 34.4 E, 18" CONC 655 ~*► � � SDMH 12319 1 Q - � � �p / IE 33.4 W, 18" CONC RIM 38.34 U 1 _ - UGP ( STA A23+19 7' LT 11 TION OF ALL SPU IE 32.1 E, 18" CI(�NC 1 f SSM H # 12 IVER PIPES APPR( PROTECT 12" SPU WATER IN PLACE, r IE N/A, W, IN ES IBLE I I "I DO NOT ALLOW EXIST PEA GRAVEL 24" IRON PIPE NE- II LLI I I M I I 1-72" DIA MH CB 67818 BACKFILL TO UNRAVEL BACKFILL PIPE ` RUNNING THROUGH TCR z o I RIM 36.39 ' I I O IE 33.4 S, 18" CPP BEDDING PER SPU STD PLAN 350 CB 12088 IE 33.8 N, 6" PVC I CB 119I I RIM 38.11 50 1 cn IE 35.7 E, 6" CONC RIM 38.37 1� I III � t I I IE 35.1 W, 12" CONC IF 35.6 NE. 12" CON I --,I SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION AT OF CO OR CPLG MAIN 655 S 2ND NIC N' AVE E: 150 LOGAN NIC N' AVE S E: *SS NO. SPECIFIC TO THIS SHEET CONC MON IN CASE PLAN REESTABLISHED PER DNR PERMIT 7373-18" T x 6" W 0 10 20 40 60 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND SCALE: 1"-20' ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS O O w U U o�S � LU z a a (D Ln�--� H a V) � EXIST GR @ II-- (n o = "t V) X ROW CL '-' Xo C0 II w x w w w ,� w w - --- -------- - ---- ----- --------- w---------- l 0 12 TYP 0 324 LF 8" C900 SS @ SLP=0.5% Q SSMH #12 11 STA 7' LTr5' LT A23+19, SSMH #11 10 RIM=38.67 IE(IN)8"(W)=28.25 28--4t STA A19+95, 5' LT IE(IN)12 z�(E)=31.903--88 RIM-37.14 �� IE(IN)8 (S)=31.90 33-�� IE(IN)8"(S)=30.09-3�8.28 IE(OUT)12'(N)=28.15zz8-.-9+ IE(OUT)8"(E)=29.80 A19+20 A19+40 A19+60 A19+80 A20+00 A20+20 A20+40 A20+60 A20+80 A21+00 A21+20 A21+40 A21+60 A21+80 A22+00 A22+20 A22+40 A22+60 A22+80 A23+00 A23+20 A23+40 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY NOTICE Jim 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE RECORD DRAWINGS SEE NOTE ON murraysmi COVER SHEET i RENTON DOWNTOWN � UTILITY � IMPROVEMENTS PROJECT 50 45 .m 35 30 25 20 15 r n ICI qT P I I rTT C) ICI ICI C)T F q O1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 O4 SPU CONDUIT AND APPURTENANCES SHALL BE INSTALLED FOR FUTURE CATHODIC PROTECTION SYSTEM (BY OTHERS), SEE DETAILS, SHT CP-2 O8 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 10 NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 4011 AND 106 11 NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 4011 402.21 AND 106 12 NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 15 CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 S2ND ST SEWER PLAN & PROFILE STA A19+20 TO STA A23+40 S-394910 SHEET SS-5 54 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021