HomeMy WebLinkAboutS-394914SEE SHEET SS-20
FOR CONTINUATION
CONSTRUCTION NOTES:
N
ra
U
a�
V)
N
z
O
V)
rY
w
w
LL
w
r,
J
w
Q
O
M
M
N
0
N
O
rn
V)
N
N
a
a)
U)
1-1
U
i
N
N
U)
ru
o-
r)
0
c
0
ry
Ln
N
N
i
00
U
a�
0
L
�I
w
HIM
35
MR
25
aim
15
item
5
RAISED WOOD PLTR
RAISED WOOD PLTR
SIDE SEWER TABLE
SIDE
APPROX
COORDINATES
SEWER NO.*
ADDRESS
STATION
OF CO OR CPLG
AT MAIN
�1
316 S 3RD ST
C15+10
N:178072.38
E: 1299433.34
�2
322 S 3RD ST
C15+17
N:178071.93
E: 1299438.33
315 S 3RD ST
NIC
N:
E:
SIDE SEWER TABLE
SIDE
APPROX
COORDINATES
SEWER NO.*
ADDRESS
STATION
OF CO OR CPLG
AT MAIN
319 S 3RD ST
NIC
N:
E:
321 S 3RD ST
NIC
N:
E:
325 S 3RD ST
NIC
N:
E:
n
U)
o-
SIDE SEWER TABLE
SIDE
APPROX
COORDINATES
SEWER NO.*
ADDRESS
STATION
OF CO OR CPLG
AT MAIN
400 S 3RD ST
SEE SS-20
N:
E:
401 S 3RD ST
NIC
N:
E:
405 S 3RD ST
NIC
N:
E:
SIDE SEWER TABLE
SIDE
APPROX
COORDINATES
SEWER NO.*
ADDRESS
STATION
OF CO OR CPLG
AT MAIN
410 S 3RD ST
NIC
N:
E:
413 S 3RD ST
NIC
N:
E:
415 S 3RD ST
NIC
N:
E:
O
00
00
,--1
U0
Q�
�V)
(� w
w=
zU-)
,—, w
J w
_ V)
U
Q
O1 CONSTRUCTION CL EQUALS R/W CL, SEE
SURVEY CONTROL PLAN, SHT G-5
10 NEW SSMH AS SHOWN PER CITY STD
DETAIL 400.1, 401, AND 106
12 NEW SANITARY SEWER PIPE PER CITY STD
DETAIL 405
13 INSTALL SIDE SEWER PER CITY STD
DETAIL 406.1, 406.2, AND/OR 407 AND CO
IF SHOWN
z PLAN
0 10 20 40 60
SCALE: 1"=20'
SIDE SEWER TABLE
SIDE
APPROX
COORDINATES
SEWER NO.*
ADDRESS
STATION
OF CO OR CPLG
AT MAIN
422 S 3RD ST
NIC
N:
E:
423 S 3RD ST
NIC
N:
E:
*SS NO. SPECIFIC TO THIS SHEET
>�
>�
> ci
> m a a
Q
>� U)Ln
N�1
U'
j
V)�
�N
z
> Z) oZS
w
~°° Ln
EXIST GR @
>
'-' w
V) rz -
F-
>
'-'
zz-
w
c~n
Ln
LnV)
Ln
O
ROW CL
�
X
OO
w
w
wwaw
X
ww
0
w a
w
w
a
0 o
00
ao
00U
0
0
0
U0
U)
~
� V)
w U)
w
LU=
=w
V
zU-)
LLI
w
U=
12 T
P
J w
=Ln
u
U
Q
Q
312 LF 24" C900
SS @ SLP=0.1%
SSMH #19 10
STA C15+87, 6' RT `�- +5 92, 5" RT
RIM=32.94 Rip.q 3 �
IE(IN)24"(W)=15.94G
IE(IN)8"(N)=16.79 +6-98
IE(OUT)24"(E)=15.64 i5.46
C14+40 C14+60 C14+80 C15+00 C15+20 C15+40 C15+60 C15+80 C16+00 C16+20 C16+40 C16+60 C16+80 C17+00 C17+20 C17+40 C17+60 C17+80 C18+00 C18+20 C18+40 C18+60 C18+80
PROFILE
SCALE: 1"=20' HORIZ, 1"=5' VERT
1\ 110/26/20221 JJM I RECORD DRAWING
NO.1 DATE BY
NOTICE JJM RECORD
0 /Z 1 DESIGNED DRAWINGS
BAW
DRAWN murra SMI
mt
IF THIS BAR DOES SEE NOTE ON
NOT MEASURE 1" TTT
THEN DRAWING IS CHECKED COVER SHEET
NOT TO SCALE
EA
RENTON DOWNTOWN
� UTILITY
� IMPROVEMENTS
PROJECT
40 RECORD DRAWINGS SHOW CONTRACTOR
SURVEYED STRUCTURE LOCATIONS AND
ELEVATIONS. THE ORIGINAL DESIGN
LOCATIONS AND ELEVATIONS ARE INDICATED
WITH STRIKETHROUGH TEXT. REFER TO
35 CONTRACT DOCUMENTS FOR ADDITIONAL
DETAILS
30
25
20
15
10
OR
S3RD ST
SEWER PLAN & PROFILE
STA C14+40 TO STA C18+80
S-394914
SHEET
58 of 121
so
REVISION
PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021