Loading...
HomeMy WebLinkAboutS-394914SEE SHEET SS-20 FOR CONTINUATION CONSTRUCTION NOTES: N ra U a� V) N z O V) rY w w LL w r, J w Q O M M N 0 N O rn V) N N a a) U) 1-1 U i N N U) ru o- r) 0 c 0 ry Ln N N i 00 U a� 0 L �I w HIM 35 MR 25 aim 15 item 5 RAISED WOOD PLTR RAISED WOOD PLTR SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN �1 316 S 3RD ST C15+10 N:178072.38 E: 1299433.34 �2 322 S 3RD ST C15+17 N:178071.93 E: 1299438.33 315 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 319 S 3RD ST NIC N: E: 321 S 3RD ST NIC N: E: 325 S 3RD ST NIC N: E: n U) o- SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 400 S 3RD ST SEE SS-20 N: E: 401 S 3RD ST NIC N: E: 405 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 410 S 3RD ST NIC N: E: 413 S 3RD ST NIC N: E: 415 S 3RD ST NIC N: E: O 00 00 ,--1 U0 Q� �V) (� w w= zU-) ,—, w J w _ V) U Q O1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 10 NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 12 NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 13 INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN z PLAN 0 10 20 40 60 SCALE: 1"=20' SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 422 S 3RD ST NIC N: E: 423 S 3RD ST NIC N: E: *SS NO. SPECIFIC TO THIS SHEET >� >� > ci > m a a Q >� U)Ln N�1 U' j V)� �N z > Z) oZS w ~°° Ln EXIST GR @ > '-' w V) rz - F- > '-' zz- w c~n Ln LnV) Ln O ROW CL � X OO w w wwaw X ww 0 w a w w a 0 o 00 ao 00U 0 0 0 U0 U) ~ � V) w U) w LU= =w V zU-) LLI w U= 12 T P J w =Ln u U Q Q 312 LF 24" C900 SS @ SLP=0.1% SSMH #19 10 STA C15+87, 6' RT `�- +5 92, 5" RT RIM=32.94 Rip.q 3 � IE(IN)24"(W)=15.94G IE(IN)8"(N)=16.79 +6-98 IE(OUT)24"(E)=15.64 i5.46 C14+40 C14+60 C14+80 C15+00 C15+20 C15+40 C15+60 C15+80 C16+00 C16+20 C16+40 C16+60 C16+80 C17+00 C17+20 C17+40 C17+60 C17+80 C18+00 C18+20 C18+40 C18+60 C18+80 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO.1 DATE BY NOTICE JJM RECORD 0 /Z 1 DESIGNED DRAWINGS BAW DRAWN murra SMI mt IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE EA RENTON DOWNTOWN � UTILITY � IMPROVEMENTS PROJECT 40 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO 35 CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 30 25 20 15 10 OR S3RD ST SEWER PLAN & PROFILE STA C14+40 TO STA C18+80 S-394914 SHEET 58 of 121 so REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021