Loading...
HomeMy WebLinkAboutS-3949150) C'0 i N INV u (3) V) N z O V) ne w LL LL W J W Q O ro N O N O \ O u7 u7 Ln N N i L0 4-+ N v / Q i N ra a a 0 c 0 c ry N N / 00 / u a) 0 L �I w / 35 30 25 20 15 10 5 00 00 �U can Q w Cn w =W Lu z W I --I w vJ 7 2 U Q ►a JAI IS D J-{■ W I SDMH 74370 RIM 33.49 Q II IE 31.0 S, 6" CONC IE 30.9 N, 6" CONC IE 31.0 SE, 6" CLAY o IE 31.2 W, 6" CLAY 504 O 3 7rtII fi CONC. MON. IN CASE REESTABLISHED STORM DRAIN GRATE PER DNR PERMIT 7373-18" T x 6 W — SD tLLV J4.Jy (9 IUrr Ur r CB 72z 94 RIM 35 85 IE 34.0 E, 6" CPP ELEV 35.111 @ TOP OF PVC CB71706 CONSTRUCTION NOTES: RIM 35.32 � r IE 32.9 S, 12" CONC IIE 32.9 N, 12" CONC I W I O1 CONSTRUCTION CL EQUALS R/W CL, SEE IE 33.6 W, 8" CPP > EE SURVEY CONTROL PLAN, SHT G-5 CB 72350 I I� I Q RIM 36.04 I �I I O REPLACE SURVEY MONUMENT PER CITY IE 33.2 W, 6" CPP I IICD IE 33.2 E, 12" METAL STD DETAIL H031 AS REQUIRED FOR IE 33.2 N, 12" METAL EB c� o CONSTRUCTION CD O P_ _ _ 11 NEW DROP SSMH AS SHOWN PER CITY STD S �� j - - 1�_j I I � CD P � DETAIL 400.1, 4011 402.2 AND 106 _CD12 NEW SANITARY SEWER PIPE PER CITY STD P N DETAIL 405 as - _x U o ■ — — UGP— — — — xll(,P— — ,_� CONC. MON. IN CASE REESTABLISHED 12 PP SD 12 PP SD KB-10 Q PER DNR PERMIT 7373-18 T 6 W KB -I I I x 1 KB-12 I 0 _ _ o 12"W DI-----12"W P --12"W DI-----12"W---12"W DI-r----12"W DI—�---12"W DI-----12"W D �_ — 12"W DI—o �12'4DI— — —12"W DII-----12"W DI �w C20+00 I .+o .. ` C21 00 I .. _ _ C22+00 _ �, I C23+6' CH.ONLY II W I.Lu C900 SS 35�o I I 24" C900 SS \ML A, Lo24" C900 SS J cwn I SDMH 74 660 SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 280 MORRIS SEE SS-21 N' AVE S E: 503 S 3RD ST NIC N' E: 504 S 3RD ST SEE SS-21 N' E• SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 505 S 3RD ST NIC N' E: 507 S 3RD ST NIC N' E: 509 S 3RD ST NIC N' E: S3RD ST SIDE SEWER TABLE SIDE APPROX COORDINATES SEWER NO.* ADDRESS STATION OF CO OR CPLG AT MAIN 601 S 3RD ST NIC N' E: 613 S 3RD ST NIC N' E: *SS NO. SPECIFIC TO THIS SHEET „- I-----1=-— II U 6" S O KB-9 V��A F !n— --`�� ----G--- �G-- G-----G46 - x = _ u� P �j � P 36- I W V CB 73854 RIM 35.51 I w I IE 32.7 NE, 6" CONC I H / IE 32.8 S, 6" CONC 601 � Q I I SPIKE 111 PLAN 0 10 20 40 60 SCALE: 1"=20' 0 Q M o u7 a 0 On l n l OI__ Ln �I ZI N m >? Lu rn (1) RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS C7 (D (D EXIST GR@ II � aLu OHO ww x x ROW CL aw v7 V) X w � O X aw~ w w X u7 � u7 � cn ��� LO Lo � x w W a -- — — --- ---- ---- ---- W w w www a w - ---- ---- ---- ----- — — — — — — — -- - --L - -- - ---- --- 0 O p 0 1 O O 0 00 M r--i 0 N �U U� L V li W w =W W= wz zLn MJ JLy U12 TYP U Q Q 603 LF 24" C900 SS @ SLP=0.1% SSMH #20 11 �6% STA C18+99, 8' RT ' RT RIM=33.66 IE(IN)24"(W)=15.34 IE(IN)8"(N)=23.58 IE(OUT)24"(E)=15.27 15.86 C18+80 C19+00 C19+20 C19+40 C19+60 C19+80 C20+00 C20+20 C20+40 C20+60 C20+80 C21+00 C21+20 C21+40 C21+60 C21+80 C22+00 C22+20 C22+40 C22+60 C22+80 C23+00 C23+20 C23+40 C23+60 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1 10/26/2022 JJM RECORD DRAWING NO.1 DATE I BY NOTICE Jim RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN MUrraYSMirth IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE i RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT 35 30 25 20 10 5 S3RD ST SEWER PLAN & PROFILE STA C18+80 TO STA C23+60 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 S-394915 SHEET SS-10 59 of 121 no REVISION