Loading...
HomeMy WebLinkAboutS-394925N i U N V) N z O ne Lu LL LL Lu J Lu Q O M M N O N O N N u7 3 U) a Ln N N L0 a� v 0 U N (L) ra a a 0 c 0 ry Ln N N i 00 V) 11 U a) 0 L �I w 1 10/26/2022 JJM RECORD DRAWING NO. I DATE BY SSMH #12, SEE SHT SS-5 1-60" DIA MH 15 -d F — M-- Al — S17 ss - -- -Ss 1-2) C 23 LF INSTALLED J0+00 8"DR 17 HDPE SS BEND TO v� CONNECT NEW MH TO EXIST - - SS - - I� PIPE, MIN R-40' I KING COUNTY MANHOLE \ / R01-20 TIE-IN, SEE DET SSMHRIM 139 - - SHT SS-40 5^2-239 CONE— r IE .4 N-S, METRO SEWER 0 TO MEASUE PREVIOUSLY ABANDONED TCR T00 DTLPMH, 6.5x12x8.5' SHORING MAY BE DUCT O3 FO INSTALLED BY HDD, ENCOUNTERED IN THE PROTECT IN PLACE T VICINITY OF THE KING COUNTY EASTSIDE CTL MH, 5'x10.5'x6'--,-" DUCT INTERCEPTOR, REMOVE AND DISPOSE AS NEEDED TO COMPLETE THE WORK i NOTICE Jim 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE �- •� ` I T I -�•IIcr) II III I I I SDMH 12317 7 1 I I I RIM 38.56 IE 34.0 E, 18" CONC cn I = I IE 33.4 W, 18" CONC J \I M I II I\ / III IIII WATER LINE ALIGNMENT AS FOUND IN r FIELD in"I �� FOR CONTINUATION SEE SHEET SS-5 PLAN 0 10 20 40 60 SCALE: 1"=20' a W W 0 M U > > ~ 45 V) cr) ~ V7 EXIST GR @ X w w w X Lu ROW CL Lu 40 35 a 00 u) H110 X X X W uj W U% 30 12 ITYP 0 44 LF 12" PVC SS @ SLP=0.3% 25 A SMH #32TA J 0 + 17 , 2' LT RIM=38.41 IE(IN)12"(S)=28.04 27..94 20 IE(IN)8"(N)=31.94 -41- +9 IE(OUT)12"(W)=27.93 z1-7 1. .-8_ 15 w IE 33.2 E, 18 UUNU IE 32.8 S, 12" CONC IE 32.5 W, 18" CONC IE 35.7 E, 6" CONC IE 35.1 W, 12" CONC SDMH 12087 RIM 38.52 IE N/A, E, CAN'T SEE PIPE IE N/A, N, CAN'T SEE PIPE CONC. MON. IN CASE REESTABLISHED PER DNR -W PERMIT 7373-18"T x 6"W SS — -L D — -- — SD — — —— c BU RN ETT AVE S �S RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS MIR us] 35 SSMH #12 11 25 STA A23+19, 7' LT= STA J 0 + 61, 7' LT ' LT RIM=38.67 IE(IN)8"(W)=28.25 28.4+ 20 IE(IN)12"(E)=31.90 Bi!--99 IE(IN)8"(S)=31.90 3i!.89 IE(OUT)12"(N)=28.15 28.3+ JO+00 JO+20 JO+40 JO+60 JO+80 J1+00 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT RECORD DRAWINGS SEE NOTEMUrraySMirth SHEE COVERRSHEET i 15 RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT rnl\IgTR I IrTTnl\l I\InTFq O1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 O3 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF EXIST UTILITY O8 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 11 NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.2, AND 106 12 NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 15 CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 BURNETT AVE S SEWER PLAN & PROFILE STA 30+00 TO STA 31+00 S-394925 SHEET SS-22 69 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021