Loading...
HomeMy WebLinkAboutzW-3949set0) cM N d� C'M N d) d� cM O W U N V) ry 0 0 O N M N 0 N Ln N 0, 70 z w (? N N / V) / Q CL N a 0 0 a� i Ln N N 00 / V) U 0 L d I Lu / 4L CITY OF CITY OF RENTON 1055 S GRADY WAY RENTON, WA 98057 RENTON, WASHINGTON DOWNTOWN UTILITY IMPROVEMENT PROJECT JANUARY 2021 CITY OF RENTON OFFICIALS ARMONDO PAVONE ANGELINA BENEDETTI RANDY CORMAN RYAN MCIRVIN VALERIE O'HALLORAN RUTH PEREZ ED PRINCE KIM-KHANH VAN MAYOR COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER CITY PROJECT MANAGER MIKE BENOIT 425-430-7206 MBENOIT@RENTONWA.GOV DESIGN ENGINEER TY TADANO 206-462-7030 TY.TADANO@MURRAYSMITH.US murra srn1 600 UNIVERSITY STREET, SUITE 300 SEATTLE, WA 98101 P 206.462.7030 i RECORD DRAWINGS THIS DRAWING IS PROVIDED FOR RECORD PURPOSES ONLY, AND HAS BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS RELATIVE TO REPORTED CONSTRUCTED CONDITIONS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE AS OF OCTOBER 26, 2022, MURRAYSMITH MAKE NO ASSURANCES, STATED OR IMPLIED, AS TO THE ACCURACY OF THIS DRAWING. THOSE RELYING ON THIS RECORD DRAWING FOR ANY PURPOSE ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY. CONTRACT MODIFICATION INFORMATION, FABRICATORS SHOP DRAWINGS AND OTHER PROJECT SUBMITTAL INFORMATION PROVIDED BY THE CONTRACTOR WHICH FURTHER CLARIFY DETAILS OF CONSTRUCTION MAY BE ON FILE. SEE ORIGINAL CONTRACT DRAWINGS FOR ENGINEER'S SEAL AND SIGNATURES. Know what's below. Call before you dig. LAKE WADI aCdDJSL U1J eJ o� r 0 �0 U L `) w � a J � w � ❑ z n H SI34TH SW 4SUNSET gLVD L a ��TY 0 RENT Ll TTO I Tno11�411 � LU LU Y. lk"� lul i mi�p F�i VICINITY MAP SCALE: 1 "=1000' R-394901 W-394901 S-394901 3949 18-2251 so 07 lqi- Cy) M N It 0) C'7 O LU U J N w Y a m 0 a 0 a N fM N O N v7 N N (b 0) 3 -0 z w C7 a U) N N m a� a� V) 0 a U N a� ra a a c 0 +-) c a� Ln N N i 00 +-J U a F- w no INDEX OF DRAWINGS GENERAL 66 SS-19 1 G-1 TITLE SHEET AND VICINITY MAP 67 SS-20 2 G-2 SHEET INDEX 68 SS-21 3 G-3 SYMBOLS AND LEGEND 69 SS-22 4 G-4 ABBREVIATIONS 70 SS-24 5 G-5 GENERAL AND EROSION CONTROL NOTES 71 SS-25 6 G-6 SURVEY DATA CONTROL PLAN AND NOTES 72 SS-26 7 G-7 PRECONSTRUCTION POTHOLE AND GEOTECHNICAL PLAN AND BLOCK DESIGNATIONS 73 SS-27 8 G-8 PRECONSTRUCTION POTHOLE DATA TABLE 74 SS-28 9 G-9 TYPICAL EROSION & SEDIMENT CONTROL PLAN AND NOTES 75 SS-40 76 SS-41 DEMOLITION PLANS 77 SS-42 10 D-1 & D-2 S 2ND ST UTILITY DEMOLITION PLANS STA AO+00 TO STA A9+60 11 D-3 & D-4 S 2ND ST UTILITY DEMOLITION PLANS STA A9+60 TO STA A19+20 12 D-5 & D-6 S 2ND ST & S 3RD ST UTILITY DEMOLITION PLANS STA A19+20 TO STA A23+40 & STA CO+00 TO STA C4+80 13 D-7 & D-8 S 3RD ST UTILITY DEMOLITION PLANS STA C4+80 TO STA C14+40 14 D-9 & D-10 S 3RD ST UTILITY DEMOLITION PLANS STA C14+40 TO STA C24+00 15 D-11 & D-12 S 3RD ST & PARKING LOT UTILITY DEMOLITION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+00 16 D-13 & D-14 PARKING LOT UTILITY DEMOLITION PLANS STA E5+00 TO STA E11+51 17 D-15 & D-16 SHATTUCK AVE S UTILITY DEMOLITION PLANS STA FO+00 TO STA F9+60 18 D-17 & D-18 SHATTUCK AVE S UTILITY DEMOLITION PLANS STA F9+60 TO STA F16+00 19 D-19 & D-20 WHITWORTH AVE S UTILITY DEMOLITION PLANS STA GO+00 TO STA G6+00 20 D-21 MORRIS AVE S UTILITY DEMOLITION PLANS STA HO+00 TO STA H6+00 21 D-24 S 2ND ST UTILITY DEMOLITION PLAN STA KO+00 TO STA K4+00 22 D-25 & D-26 MILL AVE S UTILITY DEMOLITION PLANS STA LO+00 TO STA L9+60 SCH A: STORM DRAIN IMPROVEMENTS 23 SD-3 S 2ND ST STORM PLAN & PROFILE STA A9+40 TO STA A14+00 24 SD-4 S 2ND ST STORM PLAN & PROFILE STA A14+00 TO STA A16+40 25 SD-7 S 3RD ST STORM PLAN & PROFILE STA C4+80 TO STA C9+60 26 SD-8 S 3RD ST STORM PLAN & PROFILE STA C9+60 TO STA C14+40 27 SD-9 S 3RD ST STORM PLAN & PROFILE STA C14+40 TO STA C18+80 28 SD-10 S 3RD ST STORM PLAN & PROFILE STA C18+80 TO STA C22+80 29 SD-15 SHATTUCK AVE S STORM PLAN & PROFILE STA FO+00 TO STA F5+60 30 SD-16 SHATTUCK AVE S STORM PLAN & PROFILE STA F5+60 TO F10+40 31 SD-17 SHATTUCK AVE S STORM PLAN & PROFILE STA F10+40 TO F15+00 32 SD-18 SHATTUCK AVE S STORM PLAN & PROFILE STA F15+00 TO F17+00 33 SD-19 WHITWORTH AVE S STORM PLAN & PROFILE STA GO+00 TO G3+20 34 SD-20 WHITWORTH AVE S STORM PLAN & PROFILE STA G3+20 TO G6+00 35 SD-21 MORRIS AVE S STORM PLAN & PROFILE STA H3+20 TO H6+00 36 SD-24 S 2ND ST STORM PLAN & PROFILE STA K2+80 TO K4+00 37 SD-25 MILL AVE S STORM PLAN & PROFILE STA LO+00 TO STA L4+80 38 SD-26 MILL AVE S STORM PLAN & PROFILE STA L4+80 TO STA L9+00 39 SD-40 LATERAL DRAINAGE PROFILES - 1 40 SD-41 LATERAL DRAINAGE PROFILES - 2 41 SD-42 LATERAL DRAINAGE PROFILES - 3 42 SD-43 LATERAL DRAINAGE PROFILES - 4 43 SD-44 LATERAL DRAINAGE PROFILES - 5 44 SD-45 LATERAL DRAINAGE PROFILES - 6 45 SD-50 STRUCTURAL NOTES 46 SD-51 STRUCTURAL SITE PLAN 47 SD-52 BOX CULVERT ACCESS PLAN 48 SD-53 BOX CULVERT ACCESS DETAILS 49 SD-54 BOX CULVERT PENETRATION SUPPORT DETAILS SCH B: SANITARY SEWER IMPROVEMENTS 50 SS-1 S 2ND ST SEWER PLAN & PROFILE STA AO+00 TO STA A4+80 51 SS-2 S 2ND ST SEWER PLAN & PROFILE STA A4+80 TO STA A9+60 52 SS-3 S 2ND ST SEWER PLAN & PROFILE STA A9+60 TO STA A14+00 53 SS-4 S 2ND ST SEWER PLAN & PROFILE STA A14+00 TO STA A18+80 54 SS-5 S 2ND ST SEWER PLAN & PROFILE STA A19+20 TO STA A23+40 55 SS-6 S 3RD ST SEWER PLAN & PROFILE STA CO+00 TO STA C4+80 56 SS-7 S 3RD ST SEWER PLAN & PROFILE STA C4+80 TO STA C9+60 57 SS-8 S 3RD ST SEWER PLAN & PROFILE STA C9+60 TO STA C14+40 58 SS-9 S 3RD ST SEWER PLAN & PROFILE STA C14+40 TO STA C18+80 59 SS-10 S 3RD ST SEWER PLAN & PROFILE STA C18+80 TO STA C23+60 60 SS-11 S 3RD ST SEWER PLAN & PROFILE STA C23+60 TO STA C26+15 61 SS-12 PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E1+20 TO STA E5+00 62 SS-13 PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E5+00 TO STA E8+00 63 SS-14 PARKING LOT EASEMENT SEWER PLAN & PROFILES STA E8+00 TO STA E11+60 64 SS-15 SHATTUCK AVE S SEWER PLAN & PROFILE STA FO+00 TO STA F5+60 65 SS-16 SHATTUCK AVE S SEWER PLAN & PROFILE STA F5+60 TO F6+80 WHITWORTH AVE S SEWER PLAN & PROFILE STA GO+00 TO G3+20 WHITWORTH AVE S SEWER PLAN & PROFILE STA G3+20 TO G6+00 MORRIS AVE S SEWER PLAN & PROFILE STA HO+00 TO STA H5+80 BURNETT AVE S SEWER PLAN & PROFILE STA 10+00 TO STA J1+00 S 2ND ST SEWER PLAN & PROFILE STA KO+00 TO K4+20 MILL AVE S SEWER PLAN & PROFILE STA LO+00 TO STA L4+80 MILL AVE S SEWER PLAN & PROFILE STA L4+80 TO STA L9+00 SIDE SEWER SEWER PLAN & PROFILE STA NO+00 TO STA N4+00 RAINIER AVE S SEWER PLAN & PROFILE STA BO+00 TO STA B3+20 KING COUNTY CONNECTION DETAIL S 2ND ST & BURNETT AVE S KING COUNTY CONNECTION DETAIL S 3RD ST & BURNETT AVE S MISCELLANEOUS SEWER DETAILS SCH C: WATER IMPROVEMENTS 78 W-1 S 2ND ST WATER PLAN & PROFILE STA AO+00 TO STA A4+80 79 W-2 S 2ND ST WATER PLAN & PROFILE STA A4+80 TO STA A9+60 80 W-3 S 2ND ST WATER PLAN & PROFILE STA A9+60 TO STA A14+40 81 W-15 SHATTUCK AVE S WATER PLAN & PROFILE STA FO+00 TO STA F4+80 82 W-16 SHATTUCK AVE S WATER PLAN & PROFILE STA F4+80 TO F10+60 83 W-19 WHITWORTH AVE S WATER PLAN & PROFILE STA GO+00 TO G3+20 84 W-20 WHITWORTH AVE S WATER PLAN & PROFILE STA G3+20 TO G6+00 85 W-25 MILL AVE S WATER PLAN & PROFILE STA LO+00 TO STA L4+80 86 W-26 MILL AVE S WATER PLAN & PROFILE STA L4+80 TO STA L9+00 87 W-29 LAKE AVE S WATER PLAN & PROFILE STA QO+00 TO STA Q2+00 88 W-30 RENTON HIGH SCHOOL WATER PLAN & PROFILE STA SO+00 TO STA S1+00 89 W-31 SMITHERS AVE S WATER PLAN & PROFILE STA RO+00 TO STA R1+00 90 W-40 WATER CONNECTION DETAILS - 1 91 W-41 WATER CONNECTION DETAILS - 2 92 W-42 WATER CONNECTION DETAILS - 3 93 W-43 WATER CONNECTION DETAILS - 4 94 W-44 POLYPIG PLAN AND TEMPORARY THRUST BLOCKING CATHODIC PROTECTION 95 CP-1 CATHODIC PROTECTION - 1 96 CP-2 CATHODIC PROTECTION - 2 ROADWAY RESTORATION PLANS 97 R-1 & R-2 S 2ND ST ROADWAY RESTORATION PLANS STA AO+00 TO STA A9+60 98 R-3 & R-4 S 2ND ST ROADWAY RESTORATION PLANS STA A9+60 TO STA A19+20 99 R-5 & R-6 S 2ND ST & S 3RD ST ROADWAY RESTORATION PLANS STA A19+20 TO STA A23+40 & STA CO+00 TO STA C4+80 100 R-7 & R-8 S 3RD ST ROADWAY RESTORATION PLANS STA C4+80 TO STA C14+40 101 R-9 & R-10 S 3RD ST ROADWAY RESTORATION PLANS STA C14+40 TO STA C24+00 102 R-11 & R-12 S 3RD ST & PARKING LOT ROADWAY RESTORATION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+00 103 R-13 & R-14 PARKING LOT ROADWAY RESTORATION PLANS STA E5+00 TO STA E11+00 104 R-15 & R-16 SHATTUCK AVE S ROADWAY RESTORATION PLANS STA FO+00 TO STA F9+60 105 R-17 & R-18 SHATTUCK AVE S ROADWAY RESTORATION PLANS STA F9+60 TO STA F16+80 106 R-19 & R-20 WHITWORTH AVE S ROADWAY RESTORATION PLANS STA GO+00 TO STA G6+00 107 R-21 MORRIS AVE S ROADWAY RESTORATION PLANS STA HO+00 TO STA H6+00 108 R-24 S 2ND ST ROADWAY RESTORATION PLANS STA KO+00 TO STA K5+60 109 R-25 & R-26 MILL AVE S ROADWAY RESTORATION PLANS STA LO+00 TO STA L9+00 110 R-29 & R-30 LAKE AVE S & SMITHERS AVE S RESTORATION PLANS STA QO+00 TO STA Q2+00 & STA RO+00 TO STA R2+00 111 R-31 CURB RAMP DETAILS - 1 112 R-32 CURB RAMP DETAILS - 2 113 R-33 CURB RAMP DETAILS - 3 114 R-34 CURB RAMP DETAILS - 4 115 R-35 CURB RAMP DETAILS - 5 116 R-36 CURB RAMP DETAILS - 6 117 R-37 CURB RAMP DETAILS - 7 118 R-38 CURB RAMP DETAILS - 8 119 R-39 CURB RAMP DETAILS - 9 120 R-40 RESTORATION AND TRENCH DETAILS 121 R-41 LUMINAIRE FOUNDATION NOTICE Jim RECORD 0 Y 1 DESIGNED DRAWINGS BAW DRAWN murraysmirth IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET 1 10/26/2022 JJM RECORD DRAWING NOT TO SCALE NO. DATE BY REVISION i RENTON DOWNTOWN • UTILITY IMPROVEMENTS PROJECT NOTES: 1. SHEET NUMBER IS BASED ON ALIGNMENT AND STATION. IT IS CONSISTENT ACROSS UTILITY SETS SO THAT THE EXTENTS SHOWN IN A GIVEN SHEET NUMBER FOR ONE UTILITY MATCH THOSE SHOWN ON THE SAME SHEET NUMBER FOR THE OTHER UTILITIES. SEE SHEET G-6 FOR SHEET PLAN. 2. SHEET NUMBERS ARE OMITTED WHEN THERE IS NO UTILITY WORK IN THAT AREA OF THE PROJECT (I.E. W-3 IS FOLLOWED BY W-15 BECAUSE THERE ARE NO WATER IMPROVEMENTS ON SHEETS 4 THROUGH 14). UTILITY IMPROVEMENTS ON SHEET 23 WERE REMOVED FROM THE PROJECT, THUS SHEET 23 IS OMITTED FROM ALL SHEET SETS. 3. DETAIL SHEETS ARE AT THE END OF THE UTILITY SETS BEGINNING WITH SHEET NUMBER 40. R-394902 W-394902 S-394902 SHEET INDEX PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: January 2021 SHEET G-2 2 of 121 LEGEND U H Ul N w Y Q m 0 Q a N M N O N Ln N fM Qb cm 3 _0 z w C7 Ln N N m a� a� V) 0 Q N a� a a c 0 +-) c a� Ln N N i 00 +1 U a F_ w EXISTING PROPOSED EXISTING PROPOSED WATERLINE 1011W — 12" DI W — SANITARY SEWER MANHOLE O O OVERHEAD ELECTRICITY ----OE- - - - OE- ----OE----OE- TYPE 2 CATCH BASIN O❑ O GAS 411G CLEAN -OUT O O TELEPHONE/TELEMETRY - - T - - TYPE 1 CATCH BASIN ❑ ■ SANITARY SEWER LINE 8"SS —8"SS— REDUCER a STORM DRAIN 8"SD —8"SD— THRUST BLOCK ABANDON PIPE VALVE m N DRAINAGE DITCH • • • • • BLOW -OFF ASSEMBLY BARBWIRE FENCE POLYPIG ASSEMBLY ]OC CHAIN LINK FENCE x FIRE HYDRANT ASSEMBLY O Ak CONSTRUCTION FENCE WATER METER EE m TREE PROTECTION FENCE FITTING 'ri 3ZC CLEARING LIMITS _ — CATHODIC PROTECTION TEST STATION Ts TEMPORARY SILT FENCE n n COUPLING 0 GUARDRAIL 0 0 0 0 0 0 0 0 0 0 0 0 0 ECOLOGY BLOCK m RETAINING WALL ANODE TREE/BUSH LINE PULL BOX/JUNCTION BOX CENTERLINE UTILITY POLE -0- EASEMENT/PROPERTY LINE --- -- --- GUY WIRE c___ RIGHT-OF-WAY — — LIGHT POST 0 EDGE OF PAVEMENT/AC ............................... SIGN -� EDGE OF GRAVEL _ _ _ _ _ BENCHMARK CURB TREE DECIDUOUS O SIDEWALK S/W TREE CONIFEROUS STRUCTURE OR FACILITY POTHOLE # GEOTECHNICAL BORING O MONITORING WELL SECTION AND DETAIL DESIGNATIONS SECTION DESIGNATIONS DETAIL DESIGNATIONS SECTION LETTER LA 2 DESIGNATION SHEET WHERE SECTION IS SHOWN * SECTION LETTER SECTION DESIGNATION A SCALE: 2 SHEET FROM WHICH SECTION IS TAKEN * DETAIL - NUMBER DETAIL SCALE: SHEET FROM WHICH DETAIL IS TAKEN * * NOTE: IF PLAN AND SECTION FOR DETAIL CALL -OUT AND DETAIL ARE SHOWN ON THE SAME DRAWING, DRAWING NUMBER IS REPLACED WITH A DASH. 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY NOTICE Jim RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murraysmirlh IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE i RENTON DOWNTOWN • UTILITY IMPROVEMENTS PROJECT R-394903 W-394903 S-394903 SYMBOLS AND LEGEND SHEET G-3 3 of 121 .. REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: January 2021 C'O N C7 Nt d) C'O N d� C'O O W U H J N w Y a m 0 a Q a N fM N O N v7 N C� 3 _0 z w C7 a u7 N N i m a� a� Q a U N a� ra a a 0 c 0 c a� N N i 00 i U N 0 a F_ w no @ AT C TO C CENTER TO CENTER F FAHRENHEIT LAT LATITUDE RAD RADIUS W WATER/WEST AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY CARV COMBINATION AIR RELEASE VALVE FA FOUL AIR LB POUND RC REINFORCED CONCRETE W/ WITH & TRANSPORTATION OFFICIALS CB CATCH BASIN FAB FABRICATE LF LINEAR FOOT RCP REINFORCED CONCRETE PIPE W/O WITHOUT AB ANCHOR BOLT CCP CONCRETE CYLINDER PIPE FCA FLANGE COUPLING ADAPTER LIN LINEAL RD ROAD, ROOF DRAIN WM WATER METER ABAN (D) ABANDON (ED) CCW COUNTER CLOCKWISE FCO FLOOR CLEANOUT LN LANE RDCR REDUCER WMN WATER MAIN ABV ABOVE CDF CONTROLLED DENSITY FILL FD FLOOR DRAIN LOC LOCATION REF REFERENCE WS WATER STOP / WELDED STEEL / AC ASBESTOS CEMENT CHAN CHANNEL FDN FOUNDATION LONG LONGITUDINAL REINF REINFORCE (D) (ING) (MENT) WATER SERVICE/ WATER SURFACE ACP ASPHALTIC CONCRETE PAVING CHFR CHAMFER FE FLOW ELEMENT LP LOW PRESSURE/ LOW POINT REQ'D REQUIRED WSDOT WASHINGTON STATE DEPARTMENT OF ADA AMERICANS WITH DISABILITIES ACT CHKV CHECK VALVE FEXT FIRE EXTINGUISHER LPT LOW POINT RESTR RESTRAINED TRANSPORTATION ADJ ADJUSTABLE CIP CAST IRON PIPE FIT FLOW INDICATING TRANSMITTER LRG LARGE RET RETAINING WTRT WATERTIGHT ADJC ADJACENT CIPC CAST IN PLACE CONCRETE FF FINISH FLOOR LS LONG SLEEVE / LUMP SUM RFCA RESTRAINED FLANGE COUPLING ADAPTER WWF WELDED WIRE FABRIC ADPTR ADAPTER CISP CAST IRON SOIL PIPE FG FINISHED GRADE LT LEFT RI RESTRAINED JOINT AE ANALYZING ELEMENT CJ CONSTRUCTION JOINT FGL FIBERGLASS LTF LENGTH TO FIT ROW RIGHT-OF-WAY AFF ABOVE FINISHED FLOOR CL CENTERLINE FH FIRE HYDRANT LVC LIMITS OF VERTICAL CURVE RPBP REDUCED PRESSURE BACKFLOW AFG ABOVE FINISHED GRADE CLJ CONTROL JOINT FIN GR FINISHED GRADE LVL LEVEL PREVENTION DEVICE AFG ACTUAL CUBIC FEET PERMIT CLR CLEAR FITG FITTING LWL LOW WATER LINE RST REINFORCING STEEL AHR ANCHOR CMP CORRUGATED METAL PIPE FLEX FLEXIBLE RT RIGHT AIT ANALYZING INDICATION TRANSMITTER CMU CONCRETE MASONRY UNIT FLG FLANGE MAN MANUAL RW RAW WATER AL ALUMINUM CO CLEANOUT FLR FLOOR MATL MATERIAL R/W RIGHT-OF-WAY ALT ALTERNATE COL COLUMN FM FORCE MAIN MAX MAXIMUM ANSI AMERICAN NATIONAL STANDARDS INSTITUTE COMB COMBINATION FO FIBER OPTIC MCC MOTOR CONTROL CENTER S SOUTH APPROX APPROXIMATE CONC CONCRETE FOC FACE OF CONCRETE MCP MASTER CONTROL PANEL SALV SALVAGE APPVD APPROVED CONN CONNECTION FPM FEET PER MINUTE MECH MECHANICAL SAN SANITARY APWA AMERICAN PUBLIC WORKS ASSOCIATION CONST CONSTRUCTION FPS FEET PER SECOND MET METAL SCFM STANDARD CUBIC FEET PER MINUTE ARCH ARCHITECTURAL CONT CONTINUOUS / CONTINUATION FRP FIBERGLASS REINFORCED PLASTIC MFR MANUFACTURER SCHED SCHEDULE ARV AIR RELEASE VALVE CONTR CONTRACT (OR) FS FLOW SWITCH/ FIRE STATION MGD MILLION GALLONS PER DAY SD STORM DRAIN ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS COORD COORDINATE FT FEET / FOOT MGMT MANAGEMENT SDL SADDLE ASSN ASSOCIATION COP COPPER FTG FOOTING MH MANHOLE SDR STANDARD DIMENSION RATIO ASSY ASSEMBLY COR CITY OF RENTON FUT FUTURE MIN MINIMUM SECT SECTION ASTM AMERICAN SOCIETY FOR TESTING CORP CORPORATION FXTR FIXTURE MISC MISCELLANEOUS SHT SHEET AND MATERIALS CORR CORRUGATED MJ MECHANICAL JOINT SIM SIMILAR ATM ATMOSPHERE CP CONTROL POINT G GAS MO MASONRY OPENING SLP/SL/S SLOPE AUTO AUTOMATIC CPLG COUPLING GA GAUGE MON MONUMENT SLV SLEEVE AUX AUXILIARY CR CRUSHED ROCK GAL GALLON MOT MOTOR SPEC (S) SPECIFICATION (S) AVE AVENUE CS COMBINED SEWER GALV GALVANIZED SPG SPACING AVG AVERAGE CSBC CRUSHED SURFACING BASE COURSE GB GRADE BREAK N NORTH SPL SPOOL AWWA AMERICAN WATER WORKS ASSOCIATION CSP CONCRETE SEWER PIPE GI GALVANIZED IRON NA NOT APPLICABLE SQ SQUARE CSTC CRUSHED SURFACING TOP COURSE GIP GALVANIZED IRON PIPE NC NORMALLY CLOSED SQ FT SQUARE FOOT BETW BETWEEN CT COURT GIS GEOGRAPHIC INFORMATION SYSTEM NIC NOT IN CONTRACT SQ IN SQUARE INCH BFD BACKFLOW PREVENTION DEVICE CTR CENTER GL GLASS NO/NO. NORMALLY OPEN/NUMBER SQ YD SQUARE YARD BFILL BACK FILL CU CUBIC GR GRADE NOM NOMINAL SS SANITARY SEWER BFV BUTTERFLY VALVE CV CONTROL VALVE GR LN GRADE LINE NORM NORMAL SS MH SANITARY MANHOLE BIO BIOLOGICAL CW CLOCKWISE / COLD WATER GRTG GRATING NPW NON POTABLE WATER SST STAINLESS STEEL BKGD BACKGROUND CY CUBIC YARDS GS GROUND SURFACE NRS NON -RISING STEM ST STREET BLDG BUILDING GV GATE VALVE NTS NOT TO SCALE STA STATION BLK BLOCK D DRAIN GRVL GRAVEL STD STANDARD BLVD BOULEVARD DEFL DEFLECTION OC ON CENTER STL STEEL BM BENCHMARK DET DETAIL HAZ HAZARDOUS OD OUTSIDE DIAMETER S/W SIDEWALK BMP BEST MANAGEMENT PRACTICE DI DUCTILE IRON HB HOSE BIBB OF OVERFLOW, OUTSIDE FACE BO BLOWOFF DIA DIAMETER HD HUB DRAIN OHP OVER HEAD POWER T TANGENT BOC BACK OF CURB DIM DIMENSION HDPE HIGH DENSITY POLYETHYLENE OHWM ORDINARY HIGH WATER MARK TB THRUST BLOCK BOW BOTTOM OF WALL DIR DIRECTION HDR HEADER OPNG OPENING TC TOP OF CONCRETE / TOP OF CURB BR BRINE DIST DISTANCE HDWE HARDWARE OPP OPPOSITE TEL TELEPHONE BS BOTH SIDES DIV DIVISION HGR HANGER ORIG ORIGINAL TEMP TEMPERATURE / TEMPORARY BSMT BASEMENT DN DOWN HGT HEIGHT OVHD OVERHEAD THK THICK BV BALL VALVE DOE DEPARTMENT OF ECOLOGY HMA HOT MIX ASPHALT THRD THREAD (ED) BVCS BEGIN VERTICAL CURVE STATION DR DRIVE/ DRAIN HNDRL HAND RAIL P&ID PROCESS AND INSTRUMENTATION DIAGRAM THRU THROUGH BVCE BEGIN VERTICAL CURVE ELEVATION DS DOWNSPOUT HOA HAND -OFF -AUTO PE PLAIN END TOW TOP OF WALL BW BOTTOM OF WALL DWG DRAWING HOR HAND -OFF -REMOTE PERF PERFORATED TP TEST PIT / TOP OF PAVEMENT / BWD BACKWASH DRAIN DWL DOWEL HORIZ HORIZONTAL PERM PERMANENT TURNING POINT BWS BACKWASH SUPPLY DWV DRAIN WASTE AND VENT HP HIGH PRESSURE / HORSEPOWER PERP PERPENDICULAR TPZ TREE PROTECTION ZONE DWY DRIVEWAY HPT HIGH POINT PG PRESSURE GAGE TRANS TRANSITION HYD HYDRANT PL PROPERTY LINE / PLATE / PLASTIC TW TOP OF WALL / TREATED WATER E EAST P-LAM PLASTIC LAMINATE TYP TYPICAL EA EACH I&C INSTRUMENTATION & CONTROL PLBG PLUMBING EC ENUSTON CONTROL ID INSIDE DIAMETER PNL PANEL UIC UNDERGROUND INJECTION CONTROL ECC ECCENTRIC IE INVERT ELEVATION POLY POLYETHYLENE UG UNDERGROUND EL ELEVATION IMPVT IMPROVEMENT PP POLYPROPYLENE UGP UNDERGROUND POWER ELB ELBOW IN INCH PRCST PRECAST UN UNION ELEC ELECTRICAL INCC INCLUDE (D) (ING) PREP PREPARATION UON UNLESS OTHERWISE NOTED ENCL ENCLOSURE INSTL INSTALLATION / INSTALL PRESS PRESSURE USGS UNITED STATES GEOLOGIC SURVEY EOP EDGE OF PAVEMENT INTER INTERCEPTOR PROP PROPERTY/ PROPOSED EQL EQUAL INTR INTERIOR PRV PRESSURE REDUCING VALVE V VENT / VOLT EQUIP EQUIPMENT INV INVERT PSIG POUNDS PER SQUARE INCH GAGE VAC VACUUM ESC EROSION SEDIMENT CONTROL PSL PIPE SLEEVE VB VACUUM BREAKER EUH ELECTRIC UNIT HEATER JT JOINT PSPT PIPE SUPPORT VBOX VALVE BOX EW EACH WAY JUNC JUNCTION PV PLUG VALVE VC VERTICAL CURVE EVCS END VERTICAL CURVE STATION PVC POLYVINYL CHLORIDE VERT VERTICAL EVCE END VERTICAL CURVE ELEVATION KVA KILOVOLT AMPERE PVI POINT VERTICAL INTERSECTION VOL VOLUME EXC EXCAVATE KW KILOWATT PVMT PAVEMENT VTPAV VERTICAL TURBINE PUMP AIR VALVE EXIST EXISTING PW POTABLE WATER VTR VENT THROUGH ROOF EXIST GR EXISTING GRADE PWR POWER EXP EXPANSION PZ PRESSURE ZONE EXP BT EXPANSION BOLT EXP JT EXPANSION JOINT QTY QUANTITY EXT EXTERIOR R-394904 W-394904 S-394904 NOTICE 0 �z 1 IF THIS BAR DOES NOT MEASURE 1" Jim DESIGNED BAW DRAWN TTT RECORD DRAWINGS SEE NOTE ON murraysmirthIwo RENTON DOWNTOWN ® UTILITY IMPROVEMENTS ABBREVIATIONS SHEET —� THEN DRAWING CHECKED COVER SHEET PROJECT 1 10/26/2022 JJM RECORD DRAWING NOT TO SCA EIS 4 Of 121 NO. DATE BY REVISION PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: January 2021 U H V) .. U) N w w V oC Q m 0 Q 0 rl N m N 0 N U) N U) �7 3 oC z w (D Q U) N N M 1-1 a) a� V) 0 Q i N (1) V) ra a rl c 0 c a� oC Ln N N i 00 i U N 0 L �I W ME GENERAL NOTES: WATER UTILITY NOTES: 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON. A THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS SCHEDULING. AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION 2. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL WORKS DEPARTMENT AND THE LATEST EDITION OF THE ROAD, BRIDGE AND NECESSARY PERMITS PRIOR TO CONSTRUCTION. MUNICIPAL CONSTRUCTION PREPARED BY WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1- 800-424- 5555 TO VERIFY PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS DATUM 1988 (NAVD 88), AND FOR HORIZONTAL CONTROL SHALL BE NORTH SHALL BE NEW AND UNDAMAGED, AND CATALOG CUTS" FOR ALL MATERIALS SHALL BE AMERICAN DATUM 1983/1991 (NAD 83/91) UNLESS OTHERWISE APPROVED BY APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK ON- SITE. AND ELEVATIONS ARE NOTED ON THE PLANS. 4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION AND ELEVATION SO AS TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL POTHOLE AS NEEDED TO CONFIRM THE LOCATION, DEPTH, SIZE, MATERIAL, AND CONFIGURATION OF EXISTING UTILITIES. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 5. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING CONSTRUCTION. 6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. THE PLAN SHALL BE CONSISTENT WITH THE PROVISIONS FOUND IN THE STATE OF WASHINGTON MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) FOR STREETS AND HIGHWAYS AND WSDOT STANDARD PLANS. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 8. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 7:00 AM TO 6:00 PM ON WEEKDAYS SUBJECT TO THE RESTRICTIONS DETAILED IN THE SPECIFICATIONS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT 425-430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 9. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION CONFERENCE. 10. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY-FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 11. ALL STRUCTURES, LOTS, SWALES, DITCHES, CURBS, SPEED BUMPS, FENCES, WALLS, MAILBOXES, SIGNS, POLES, GUY WIRES, PIPING, AND UTILITIES DISTURBED DURING CONSTRUCTION TO BE RESTORED TO EXISTING CONDITIONS UNLESS OTHERWISE SPECIFIED. SUCH REPAIR SHALL BE CONSIDERED INCIDENTAL. 12. DESIGN AND IMPLEMENTATION OF SHORING AND DEWATERING SYSTEMS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. A DEWATERING PLAN AND A SHORING SYSTEM PLAN SHALL BE SUBMITTED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 13. THE CONTRACTOR IS HEREBY ADVISED THAT CONTAMINATED SOIL AND GROUNDWATER HAS BEEN ENCOUNTERED IN THE PROJECT AREA WHICH MUST BE HANDLED AND DISPOSED OF IN COMPLIANCE WITH APPLICABLE REGULATIONS AND AS SPECIFIED IN THE SPECIAL PROVISIONS. A CONTAMINATED SOIL AND WATER MANAGEMENT PLAN SHALL BE SUBMITTED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 14. THE CONTRACTOR IS REQUIRED TO PERFORM SETTLEMENT MONITORING ON STRUCTURES AND UTILITIES DURING CONSTRUCTION IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. SETTLEMENT MONITORING RESULTS SHALL BE REPORTED TO THE ENGINEER IN A TIMELY FASHION AS DESCRIBED IN THE SPECIFICATIONS. 15. THE CONTRACTOR SHALL PROTECT AND SUPPORT AS SPECIFIED ANY AND ALL UTILITIES THAT MAY BE IMPACTED BY THE WORK, INCLUDING BUT NOT LIMITED TO THOSE SHOW IN THE PLANS. /1\ 10/26/2022 JJM RECORD DRAWING NO. DATE BY REVISION 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/ AWWA C110/ A21. 10- 82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8 -MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. ALL DUCTILE IRON PIPES, FITTINGS, AND VALVES SHALL BE RESTRAINED -JOINT PIPE. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10 -INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12 -INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE- HALF OF PIPE MANUFACTURER' S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD ( MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS ( OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. 10. TEMPORARY WATER SERVICE CONNECTIONS AND RECOMMENDED POLYPIGGING AND DISINFECTION PLAN AS SHOWN IN THIS PLAN SET ARE SCHEMATIC AND REPRESENTS THE MINIMUM WORK ANTICIPATED. THE CONTRACTOR IS REQUIRED TO SUBMIT A FULL TEMPORARY SERVICE AND POLYPIGGING/DISINFECTION PLAN AND PROVIDE TEMPORARY THRUST RESTRAINT CALCULATIONS UP TO THE MAXIMUM TEST PRESSURE. ANY VARIATION OR ADDITION TO TEMPORARY SERVICE PLAN OR POLYPIGGING AND DISINFECTION PLAN SHALL HAVE WRITTEN APPROVAL FROM THE CITY OF RENTON WATER DEPARTMENT. 11. ANTICIPATED TEMPORARY WATER SERVICES, CUT AND CAP LOCATIONS, VALVE AND HYDRANT REMOVAL, AND PIPE ABANDONMENT/REMOVAL INFORMATION IS AVAILABLE IN THE DEMOLITION SHEETS. 12. AT UTILITY CROSSINGS MAINTAIN MINIMUM VERTICAL SEPARATION OF 18" FROM ALL OTHER UTILITIES UNLESS OTHERWISE NOTED, MEASURED WALL-TO-WALL. 13. TEMPORARY 2-INCH WATER SERVICE SHALL BE POLYETHYLENE (PE) PIPE OR APPROVED EQUAL WITH THRUST RESTRAINT AND SHALL BE INSTALLED IN TRENCH WITH 24" OF COVER OVER PIPE. WORK TO INCLUDE ALL CONNECTIONS TO EXISTING WATER SERVICE LINES UPSTREAM OF EXISTING WATER METERS AND ALL REQUIRED FITTINGS. DISINFECTION AND SATISFACTORY PURITY SAMPLES SHALL BE OBTAINED FROM NEW TEMPORARY 2-INCH WATER LINE BEFORE CONNECTION TO EXISTING WATER SERVICES. SURFACE WATER DRAINAGE NOTES: 1. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 2. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL, ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 3. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 4. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. CONTRACTOR SHALL LOCATE CATCH BASIN GRATES AT THE FACE OF CURB AND SHALL VERIFY INSTALLATION LOCATIONS PRIOR TO CONSTRUCTION. 5. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 6. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.00, 204.10, 204..20, 204.30, AND 204.50. STRUCTURES SHALL HAVE: - RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. - ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. - ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 7. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 8. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 9. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 10. FOR ALL DISTURBED PREVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 11. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 12. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 13. THE LOCATION OF DIRECT CONNECTIONS OF EXISTING STORM DRAIN LATERALS TO THE EXISTING STORM DRAIN PIPE SHOWN ARE BASED ON CCTV VIDEO AND ARE APPROXIMATE. FOR ALL SUCH DIRECT CONNECTIONS SHOWN AND FOR ALL SUCH DIRECT CONNECTIONS WHICH ARE NOT SHOWN BUT ENCOUNTERED DURING CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO VERIFY IF THE EXISTING STORM DRAIN LATERAL IS ACTIVE. ADDITIONAL FITTING AND/OR STRUCTURE INSTALLATION TO RECONNECT THE EXISTING STORM DRAIN LATERAL (IF NEEDED) SHALL BE APPROVED BY THE ENGINEER. 14. NEW CATCH BASINS SHALL HAVE RECTANGULAR FRAME PER COR STD PLAN 204.00 AND RECTANGULAR VANED GRATE PER COR STD PLAN 204.20 UNLESS NOTED OTHERWISE ON THE PLANS AND PER THE FOLLOWING: • STORM ROUND FRAME AND COVER PER COR STD PLAN 204.50 WITH CONVERSION RISER PER COR STD PLAN 200.40. 17. NEW SDMH SHALL HAVE ROUND FRAME AND COVER PER COR STD PLAN 204.50 UNLESS NOTED OTHERWISE ON THE PLANS AND PER THE FOLLOWING: • RECTANGULAR FRAME PER COR STD PLAN 204.00 AND RECTANGULAR VANED GRATE PER COR STD PLAN 204.20. SANITARY SEWER NOTES: 1. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. AS -BUILT DRAWINGS SHALL INCLUDE NORTHING AND EASTING OF ALL CLEANOUTS. 2. PIPE BEDDING SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 3. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. 4. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D3034, SDR 35, OR AWWA C900 OR C905, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 5. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE TO MATCH PAVING. 6. MH LADDERS AND CONES SHALL BE ORIENTED SUCH THAT THE LADDER ENDS ON A CHANNEL BENCH AND, TO THE GREATEST EXTENT PRACTICAL, THE COVER IS OUTSIDE THE WHEELPATH OF THE TRAVELED WAY. 7. LOCATIONS OF SIDE SEWERS SHOWN ARE APPROXIMATE AND MAY NOT REFLECT ACTUAL LOCATIONS. 8. AT UTILITY CROSSINGS MAINTAIN MINIMUM TYPICAL VERTICAL SEPARATION OF 18" FROM WATER AND 12" FROM OTHER UTILITIES, MEASURED WALL TO WALL, UNLESS OTHERWISE SHOWN ON THE PLANS. NOTIFY ENGINEER IF TYPICAL VERTICAL SEPARATION CAN NOT BE MET. 6-INCH ETHAFOAM PAD MAY BE USED IF APPROVED BY THE ENGINEER RESTORATION NOTES: 1. CHANNELIZATION MARKERS SHALL BE REPLACED IN PLACE PER STANDARD PLAN 109 OR AS DIRECTED BY THE ENGINEER. MISCELLANEOUS NON-STANDARD TRAFFIC AND PARKING LINES SHALL BE REPLACED WITH THERMOPLASTIC PAINT. SHUR-CURB TRAFFIC MARKERS SHALL BE REMOVED AND REPLACED. 2. TEMPORARY CHANNELIZATION MARKINGS SHALL BE PER WSDOT STANDARD PLAN K-70.20 OR AS DIRECTED BY THE ENGINEER. 3. ALL SIGNS SHALL BE REPLACED IN PLACE, INSTALLED AS SHOWN ON THE PLANS, OR INSTALLED AS DIRECTED BY THE ENGINEER PER STANDARD PLAN 129. 4. ALL LANDSCAPING IMPACTED BY THE WORK SHALL BE REPLACED IN ACCORDANCE WITH THE SPECIFICATIONS. 5. FOR STREETS WITH PAVEMENT OVERLAY, PROVIDE CROWNED ROADWAY SECTION WITH PEAK IN THE CENTER OF THE STREET AND SLOPE OF 1.5% TO 2.0% OR AS DIRECTED BY THE ENGINEER. R-394905 W-394905 S-3949051 SHEET NOTICE Jim RECORD DESIGNED RENTON DOWNTOWN 0 /Z 1 BAW DRAWINGS N44® UTILITY GENERAL AND EROSION CONTROL DRAWN NOTES G - 5 IF THIS BAR DOES SEE NOTE ON murraysmirth'� IMPROVEMENTS NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET PROJECT NOT TO SCALE 5 of 121 PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: January 2021 N i U N V) U) N z O V) rY w LL LL w r, J w a O M N O N O I a I U) N N ,--i a) v v7 Q U N N Ln ro t d d p c 0 4 c ry N N i 00 +-) U a) 0 L �I w no ui Q w W FUTURE 12" WATER MAIN IE AT HYDRANT =31.76 \ i- 0 i o� COL O - LID LID 28.86 2 ELEV 8.46 Q TOP OF PVC 1 (BY OTHERS) STA A81-94 I I AC I + SSMH 31431 (MH6345) STA AO+96 5' RT 35 I 35 I z III RIM 41.87 1-12"X6" TEE, RJXFL I I RIM 29.4165 AC I rn I I IE 32.9 W-E @ CL ' CO1 1-6" GV, FLxRJ I/ I I SPEED HUMP IE 21.1 S, 24" CPP II � 1-FH 26 LT J- I _ STAA4+24, 4' RT IE 21.2 N, 24" CPP SDMH 65164 c� 1-12 CROSS, FL G IE 25.6 W, 8" METAL I D I RIM 29.54 �--� 144 1-TB I /I I 100 4-12" GV, FLGxRJ f C IE 24.7 E, 8" CPP I I rn I IE 20.7 S, 24" CPP I if I I O 4" CPP INSTALLED 2-450 �g BENDS, 3-FT SPOOL, AND ANCHORS TO SS - - - _S �, ROUTE UNDER DUCT BANK II G P 18- - - A� - STA 0+00, 0' s�'i' IE=31.58 AO+00 I v?r� IE=34.30 Hill �II _ • �/�/ MIC 269 -41 STA AO 00, 10' RT 16 STA AO+88 5' RT d I 1-POLYPIG 2-6 45° BEND, RJ I IE=23.36 IE 20.9 N, 2 CB 65442 IE=34.01 I o I IE 25.1 W, 8" CONC / l I I o I SQ I \ \ \ CB 65162 / RIM 30.12 I I RIM 28.86 SSMH 65930 SSMH 65941 IE 28.4 NE, 8" METAL DWY I i RIM 31.55 IE 25.3 W, 8" CPP 37 O IE 27.7 E,W,N @ CL IE 25.6 E,W @ CL l / O.NOT.ENTER .�b' _ 0 r \ , 99 �- UGP- UG -� - AC I I AC i CB 65166 P N - - /_-- P - - - -- UGP - - - -I �/ ^oRIM29.10 AC IE 27.4 NE, 8" CONC - - so �- - - - - - - - - - - - - - - - - - - S -S - - - - = SS R21 00 - _ pPK 214 T � DWY � -G -- G-----G- --�WY _- REBAR - IE=19.5 � I T __GTYP T_ + T T STA 20 --\- T-- ---T-� \19 I- --STAA4+12 - CI MW_10 QN / \. •, ,p ,. \ I Q Al+00 A2+00 \ .\ .... .... ..�. .. .... p f 27 ~ A 3 + 0 0 - i - I A 4 + 0 0 2 ,� I U)1w 1-TB .... i / - I -SD - - - - - SD - - - - I -----�----- ----NO.RT-TURN II I - - ---- Fz--� SD - - - - }E- RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 50 45 .rs 35 30 25 20 15 V) rn .... .. ... �.: .... .. .... .... .... .... .. 12"DI W 12"DI W d9 12"DI z ur) . •I . S •.2 N D ST I CONC MON IN CASE II I 37 ~' w --1 J 8" SDR 35 SS / / REESTABLISHED PER DNR _ _ U) ,� .. • . ... 8. . . SS • . ... • • . „ PERMIfi7373 - 18 T X 6 W 10 S D .. .. .... /.. .... / z ' STA A4+ 14, 20' RT Mic II " ~ / STA Q1+20 DWY C� UGP- - �- - - GP- - - - -UGP- - - - U - -I - UGP - - -UGP-® - - -UGP- - - - P UGP J - - - - UGP- -- - _ _ -31 P --UG - -- UGP - - -- -UGP- -�- - - -- f�' ----- AC--��-32 - - - - -- - - - - - - - - - - - IUGP CRPL#3 6 � CRPL#3 66" STL % \1 CB 658 \ RIM 29- n .96 - ------ AC-- IE 28.7 S, 6" CON RP-L#1� STL CRPL# 66"STL - J -� _ j-------- -- ---- ------ -- ---- -- L 5'; - - - - - - - - - - - - - - - - - - CRPL#2 51.5" STL ---- PL#251.5"STL SEE SHT W-29 FOR ALIGNMENT Q = PLAN 0 10 20 40 60 SCALE: 1"=20' a a (D = w z U- m O w Ln a 0 a w p Lu Q d Ln Ln H ---- ---- a 0 a 0 w Ln .. -- _ a- Ln Ln oo N w 11 ------ 00 EXIST GR @ a LO U) O I ---- ---- ROW CL � w p w M - ---- a U) 00 Q --- X w d N O � N N -- --- ----- ----- X LUII w _-- w Lu W2 zLn -------- ---- ---- ---- w ° z w 27 Lu = 12 "DI W O U Q XX x I x x x x x x f 392 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP I) AO+00 AO+20 AO+40 AO+60 AO+80 A1+00 A1+20 A1+40 A1+60 A1+80 A2+00 A2+20 A2+40 A2+60 A2+80 A3+00 A3+20 A3+40 A3+60 A3+80 A4+00 A4+20 A4+40 A4+60 A4+80 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE JAM RECORD 0 /Z 1 DESIGNED DRAWINGS BAW DRAWN murraysmi IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET 1 10/26/2022 JJM RECORD DRAWING NOT TO SCALE NO. DATE BY REVISION i RENTON DOWNTOWN � UTILITY IMPROVEMENTS PROJECT r`nn1CTD 11r`TTnK1 Kin-rr-C - 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 16 POLYPIG STATION IN ACCORDANCE WITH COR STD PLAN 300.6 27 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-1 34 SEE SHT W-29 PIPE CONTINUATION 35 FH ASSY PER COR STD PLAN 310.1 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-1 99 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 50 45 m 35 30 25 20 15 S2NDST WATER PLAN & PROFILE STA AO+00 TO STA A4+80 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 W-394906 SHEET W-1 78 of 121 M N U N V) J N z O ne w a w w J W a O M N O N O N >I O I I I Ln N N I a� a� 0 Q U i N a� r� a a 0 c 0 4 c I N N i 00 U a� 0 �I W 45 W 35 30 25 20 15 10 SSMH 65030 / RIM 30.29 IE 24.9 E,W cL STA A6-I-iF JOINT DEFLECTION IE 25.2 E,W @ CL / 200 F3] I STA A6+29 4' RT 15 THROUGH CURVE 1-12"x6" TEE, RJxFL STA �9+�z�+� 400 15 STA A9+41 12' LT BENC TRASHCAN 1-6" GV, FLxRJ i 211 i i ^NCO BF! i R4 O — — — _ _ — _ 8'�TLK 1-FH, 20' LT � JOINT DEFLECTION 1-12 x6 TEE, RJxFL tJGT = _ _ _ = UTG� -_ _ — dGP-r -==T�l �SSLL T _ _ �Z __ _ _ _Er 1-6"GV, FLxRJ _ SS - 4 CHLK T A 2 _ _1-TB - _ _ ._ TUB_ _ _ _ THROUGH CURVE 1-FH, 32 LT O _ - SS Ac_ - _ - SS - - I 13 LBWS J _2-6" 450 BENDS _ CJGF'= _ = s _ n 1-TB p p SS _� �`-r i 711 i i .7 CO BCnll"1 Ill 00 AC �r TWO MOUNTED SIGNAL HEADS T I F WIT =- -. DWY -� + DWY _ _ L _ - T - -_- - - O F 2 U - - T - - - T T - - - - i _ - ill U _ _ _ _ - - - - T _ _ -T __ - _ _ -_ \ CB 6 49 ' 24 IE=27.4 - STA A7+36, 0 - _ T- �S _- T RI 231. S 6" CONIC Q 8"W c22- — — — — 8>,W CI - - - 8„W 1 TYP,) - E "�V Cl - - - 6 W C1= — _ � °W� — � — -31 — — - T - _ 37 T _ .... 27 A6+ .j. IE=27.6 - 8 W CI _I _ 8„W C - - _ T _ - - - _ _ - -1J _ - T W - -� - ; -I i- I - -_ _ A7+00 - I 8 - T _ _ _ T - T m LU 12"DI W �- - W CI 8' _ _ - Z I• w ci _ _ -$- STA A9+32 0' - wJ 23 _ S 2ND ST •.: ... 418 0 ..--_8„wcl ___ ___ - 13 Ln 2 — — -- — _ IE=25.3 "w a ss _ _- U .. ... .... .. � STAA6+14 4'RT — _ — •.., •: •.. - •• _�,,W�� _ - I ` 1-12"X2" TEE SIC 259 • ' ' • , — - " \ STA A6+07 4' RT- — - 2"PVC CONL — - 8" C900•SS=�--� , '" ' ' • • — — -32 A9+ - G G - - - -- 1-12"X2"TEE --�- 1-2"GV ---G-____G_--� STA 16'1' 1 0 00 1-2" GV STA A6+59, 20 RT- 31- — _ _ I _ - I LGP_ - �1� - _ - - - T G1 - _U �Al � - -UGP- - - - - - - T - - - T - - -•- T - - - - - - _ CONIC RET WALL T DWY p CONIC RET WALL - - - -UGP- - - - _ GP I DWY �� \ T - - - T - - - FO DUC �� !" O -ta---UGP-- UGP- �� - 2 __------ - - - --------- -- - 32- - - -- -32 I. RPL#3 66" STL I - - - - - - -I-1- � - - - - - - _ STA , ' �' ------ � -`, AC ----���-- - 3�STA A9+22, 9' LT_,,-""--- - - - - - - - - - —- - J �------- SDMH 31999 --- � -�— -- --- _�_\ ��11 Q I - I -� -1-12 INSULATING SLV'\ 26 r� - - IE 5.8 W,E CL 1�1 Cl A I U Gp, \ ---------------- ----- ------ � I --- I �3Y_ � � \ � con �W CRPL#1 66" STL ,� - - -------------------------------� cal -- - - - - - _ _ - - - - - ENJ�S�-10\ZONE(E) DO.NOT. NTER(W)I �-Lu - - - -�-- �- -----------------------�� ---- �I-�t ----_- - - Z2 CRPL#251.5 STL �� ----------------- - - - - - - - AC 0 - - - - - - - - - - - - MIC257 �-1LuCB 32463 �� UGP_ - - - - UG - - UGP - - -UGP- - - RI �0�6- �\ - 32 (n y U G Q _ U GP- - - - -UGP- - - - - UGP- - _ I / - - �NACCESSIBL� FILLED W/DIRE ��� - - _ ���� V I1 vGP� - - - UGP_ _ _ - / IUGP_ _ - CONIC RET WALL - _ _ - STA A9+36 2' IT ' 203 I 1 �- UG - - - -UGP- ` I I / - UGP_ _ , \ CONIC MON IN CASE o O I ,, / 1 - _ U P� —31 _ y, _ , REESTABLISHED PER DNR 1-12" -TB 22.5 BEND, RJ E7+00 E2+00. I E8+00 E3+00 UGP- _ \ \ PERMIT 7373 - 18"T X 6"W ANIM 31.96 - - - -I- - - - - -I- - - i - _ / 211 IE 23.0 N, 1 " CCONC ONC - - - SD - - - D a -� D - - _ 5 CH-Ll���� 5' CHI K GATF \ \ _ \ \ CRPt r �� IE 23.0 E, IE �L5.9 E, 2' CONIC I RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS PLAN 0 10 20 40 60 SCALE: 1"=20' WATER SERVICE TABLE SERVICE ADDRESS SIZE APPROX STATION FIELD VERIFIED NO. AT MAIN STATION AT MAIN �1 IRRIGATION 2" A9+391 35' LT A9+431 35' LT �2 IRRIGATION 1.5" A6+171 20' LT A6+071 20' LT WATER SERVICE TABLE SERVICE APPROX STATION FIELD VERIFIED NO. ADDRESS SIZE AT MAIN STATION AT MAIN E200 S 2ND ST 2" A6+ 10, 30' LT 6+ 10.51 30' LT W W cn j M W 0 N N (D Ln � 0*)Z) m = , A IU- V1 a a N Ln a LO a ~ � V) V) p X � X II I- '-' '-'X X XX W a-W a ROW CL W a a w W W w 00 110 — + — — — — — — — — — — — — — — — — Lu w U) o v (n w = LULLJ U W = z w W 12"DI W Lu top U STA A9+23 U Qf 480 LF OF 12" CL 52 1-12" INSULATING SLV ___- -_ , v Q REST JOINT DI WATER MAIN WITH POLYWRAP TAT „-- .4 INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' A4+80 A5+00 A5+20 A5+40 A5+60 A5+80 A6+00 A6+20 A6+40 A6+60 A6+80 A7+00 A7+20 A7+40 A7+60 A7+80 A8+00 A8+20 A8+40 A8+60 A8+80 A9+00 A9+20 A9+40 A9+60 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY NOTICE JAM 0 /2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE RECORD DRAWINGS SEE NOTE ON murra sm� COVER SHEET RENTON DOWNTOWN � UTILITY IMPROVEMENTS PROJECT CONSTRUCTION NOTES: 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 11 MINIMUM SPACING OF 24" BETWEEN 2" TAPPED TEE FOR WATER SERVICE LINE AND HYDRANT TEE MEASURED EDGE TO EDGE 13 REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE 15 FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 23 PROP WATER SERVICES TO AVOID ABANDONED VAULT 26 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS 27 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-2 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-2 38 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 45 ius 35 30 25 20 15 10 S2NDST WATER PLAN & PROFILE STA A4+80 TO STA A9+60 W-394907 SHEET W-2 79 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 CONSTRUCTION NOTES: N i a t U U) N z O re w LL LL w r-, J W a O M N O N O M i O Un N N O N a� U7 i 0 Q U i N a� r� a a 0 c 0 ry Ln N N i 00 13 U �I w 45 .O 35 30 25 20 15 10 SEE SHEET W-30 FOR CONTINUATION ItLS.b t CONNECT TO EXIST 6" �� STA A9+71, 0� LT IE 25.3 SE / STA Al2 °+73 4' LT STA A13+ r- 4.3' LT CB 62912 WATER SEE SHT W-30 EXIST 6 FIRE RIM 33.15 STA F1+00, 0 RT I � 1-12 45 BEND, RJ FOR PLAN &PROFILE 1-SDMH #5 5 IE 306 N 12" CPP A SSMH 5330 KiNI JL.LI �/� SPRINKLER VAULT 1-TB Ei, CB 62819 RIM 32.22 E 29.6 S, 6" CONC SSMH 62818 IE 30.6 W, 12" CPP RIM 31 S, SDMH 62148 SSMH 62147 STA A9+84, 16' LT IE 20.5 E,W ® CL 29.2 E, 12" CPP STA Al2+64 4' LT JE W a.55 1� � r. IE 31.1 S, 6" CONC RIM 31.80 RIM 32.38 STA FO+84 13' LT F$-I 9�9-'-E� 1-12" 450 BEND RJ �- STA G-8 1 85 IE 27.5 SE, W @ CL, IE 20.8E ' ' - 4' CHLK IE 20.E S 1-12"� TEE, FLG IE=26.62 PROVIDE TEMPORARY � ` 1-TB _ _ _STA G-0+04, 9' RT 4 34 3-12 GV FLGxRJ SUPPORT AND PROTECT - W - - STA A11+75 11' LT STA Al2+78 4' LT -T A 1-Tg AG EXISTING FO DUCT CB 62448 1-12" 450 BEND o 1_12 90 BEND, RJ �G DURING CONSTRUCTIO c I RIM 32.12 1-TB T AC RAMP - -33�•3 N, 6" STA A1�2��� 1-TB ®� AC --- T-----T-IE=26.97 T -- ---- - - -T - - - �\ - 33- STA Al2+43 4 LT STA Al2+87 W - - -- _ - - _ • 1-12 GV RJxRJ _ - = T - - O �- - , �� - - T - P _ - - -ter - - u�r-- - _ YTGP� -STA G0+00 " _ _� �� _ _ 4'Y - fi - - 4"W - - - l0 - STA A 10 + 20 13' LT - - - - - - T`� -- -4 4 �- - - --E�1= T - - - ss STAA12+35 4 LT T==== -T--- + 1-12" INSULATING SLV - - - _ ---- --- --- ss-� - ss- -- 9&�----ss - -SS ---- _ _ j3 15 p SS - - 37 ■ 12"C 00 SD•1-12" INSULATING SLV - - N Q _ SS - - - -CsS - - - SS - - - .- S- �S = - n ��, - - Ss - -.- . .- -. SS �. - - - S'? .� - - - �S• - - - Q J� ���FO DU S 2ND ST 79 S/l_ SSMH 62820 �,.. \/ \/ // ~ A11+00- - `4 - - -#00 wAl2+00 - - - - --o-A13+00 ■ 12"PP SD�[A14+00 TYP 1 --_ --- L LV.v L •LU Lu O Lu SD lu <I ,/� .III►. i III FOR CONTINUATION SEE SHEET W-15 - �- --------------IE=26.9----------- - - - - - - -- ---------- CTf OLS CY 6" STL 26 /� �\ -- - -cR 3 6�ST - FOUND PREVIOUSLY STA A11+81 5' LT 26 - 9 �y 2 6 v- -34- - - - - - - O-----------------------CRPL -- STL ------ 13 6 STA A14+00 39' RT 1-12" 45° BEND 8 - UqP • 33" iVIP 1-12" GV RJxRJ 2 UNKNOWN LUMEN FO DUCT _ �� ' ' ^-, �� ' T P - - - UG - 1-TB UGP- - - GP- - - - � U P- - � = KB-2 26 B - ,�- - 2-12" SOLID SLV, RJ - �-�-=- . 11 UGP- - - - STA A+ r; --rT =-� $ -3 2 PVC CONDUIT STA A11+48 10' LT = STA S1+00 IE=27.05 sp IE=26.9 8 SD 1-12" TEE, FLG - _ r �- 8�� SDR .3D D 36 TA Al2+30 4 LT iflE=IL9 33,z�Q. 3-12" GV. FLGxRJ .. 1-1" AIR RELEASE VALVE 20 1 .16 ® 1-TB o / i"DI SD CASE 81815 1 1211)($" RDCR "VW DI - 12"W DI -32_B =SD= - �4-45°BENDS --� -SD -----s - - ---- - - - S' j --SD -- ---- ---- - ,, -STA A13+04 39' RT -- - -- W.-PI+Gff �� P _ _ � �P= GpS7G--U =UGP- - -�P - - - _ = U BP� _ UGP- - - UG - - -- - - - U� - `-'=4 �I �' - - _ F - 1-12" INSULATING SLV _ STA Al2+78 39' RT w - IE-27.15 - - - - 1-12" TEE, FLG SDMH 633 T IE=26.35 iI D CB 62661 3-12" GV, FLGxRJ RIM 7 28A S, 6" CONC Q 1 CB 63513 W-40 RIM 31.33 RECORD DRAWINGS SHOW CONTRACTOR 1-TB IE 28.3 E, 12" CONC = 15 DIKA 701)1) 28.8 N, 6" CONIC SURVEYED STRUCTURE LOCATIONS AND STA Al2+86 39' RT IE 28.3 W, 12" CONC 1 STA Al2+92, 39' RT ELEVATIONS. THE ORIGINAL DESIGN 1-22.50 BEND, RJ IE 28.4 NE, 4' CONC - 27 1 1-22.50 BEND, RJ LOCATIONS AND ELEVATIONS ARE 1-TB CB 63515 0 1-TB INDICATED WITH STRIKETHROUGH TEXT. plA^ �� �� � FOR CONTINUATION REFER TO CONTRACT DOCUMENTS FOR PLAN ADDITIONAL DETAILS ~ SEE SHEET W-19 0 10 20 40 60 >_ SCALE: 1"=20' nmr,, 1 W DI - - �1�1.� - CB 63332 / Li RIM 32.66 IE 29.2 W, 12" CONC IE 29.2 E, 12" CONC IE 30.3 N, 6" METAL(THROUGH) IE 30.3 S, 6" METAL(THROUHG) 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 6 12" GATE VALVE TO BE CUT IN BY CITY FORCES PRIOR TO ABANDONMENT OF EXIST WATER < > 8 WATER SERVICES CROSSING SPU SHALL USE KAMCO MUNICIPAL AQUA SHIELD COPPER PIPE 9 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTION DETAILS SHT CP-1 13 REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE 15 FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 20 REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE 24 WATER SERVICE TO BE INSTALLED WITH A 2" SADDLE TAP PRIOR TO ABANDONMENT OF 8" WATER BETWEEN SHATTUCK AVE S AND WHITWORTH AVE S 26 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETAILS, SHT CP-1 27 TEMPORARY WATER SERVICE WITH END CAP WATER SERVICE TABLE SERVICE APPROX STATION FIELD VERIFIED NO. ADDRESS SIZE AT MAIN STATION AT MAIN �1 321 S 2ND ST 1" Al2+07, 5' LT Al2+09, 16' RT ElIRRIGATION 2" A13+26 A13+241 18' RT (D co I x M W co U EXISTGR@ ' n-N 0 � '�O00O� � � ROW CL aw HX O �11 OO O x x x WaW � O N W _x WW ,�_W d d� W - - - - - - - - - - - - + --z - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - NQ O ' U 28 w EXIST 12"DI W w W 30 1 7 L Z 1T 2" INSULATING SLV w i--i STA Al2+35 1-12" INSULATING SLV STA Al2+88 1-12" 22.5° BEND, RJ U) = 29 IE=28.9 STA Al2+64 IE=28.3 u 1-12" 450 VERT BEND, RJ 28 IEE=27.6 STAA12 8 4 1�4 ] � Lzz.5. Q Q _STA 1-12 INSULATING SLV � 2BEND, RJ3 f 320 LF OF 12 CL 52 IE=26.5 U 1R" 4 J � REST JOINT DI WATER STA Al2+73 STA Al2+78 (� MAIN WITH POLYWRAP 1-12" BEND, RJ 1-12" 22.50 BEND, RJ 45° VERT IE =3{�T 20.0 IE=26.5 STA Al2+78 1-12" 900, RJ IE=20.0 - . INSTALL JOINT BONDS AT ALL INSTALL JOINT BONDS AT ALL JOINTS JOINTS AND ANODES EVERY 20' AND ANODES EVERY 20' A9+60 A9+80 A10+00 A10+20 A10+40 A10+60 A10+80 A11+00 A11+20 A11+40 A11+60 A11+80 Al2+00 Al2+20 Al2+40 Al2+60 Al2+80 A13+00 A13+20 A13+40 A13+60 A13+80 A14+00 A14+20 A14+40 /1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY NOTICE JAM 0 /Z 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT RECORD DRAWINGS SEE NOTE ON murraysmi COVER SHEET i RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT AND THRUST RESTRAINT, SEE SHT D-3 28 SEE SHT W-19 FOR PIPE CONTINUATION 29 SEE SHT W-30 FOR PIPE CONTINUATION 30 SEE SHT W-30 FOR PIPE CONTINUATION 45 36 AIR RELEASE VALVE PER COR STD PLAN 340.3 40 < 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-3 35 30 25 20 15 10 S2NDSIT WATER PLAN & PROFILE STA A9+60 TO STA A14+40 W-394908 SHEET W-3 80 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 O) M N a U a� V7 N z 0 V) w LL LL w r-, J W Q O M N O N O Ln 0) i Ln N N i U) N N V7 i Q i N U) ra a a 0 c 0 Ln N N i 00 U, U �I w i SEE SHEET W-3 FOR CONTINUATION LI I I I k I STA F1+66 11' LT 36 / /' /' /' SDMH , 68463 STA F2+40 8 LT I STA �F1+41, 11 LT 1-1 AIR RELEASE VALVE // / / / RI 27 .70 �1-12" 450 BEND, RJ �1-12 GV, RJ � +.-B� i 1-TB 1 STA F1+76 10' LT 1-TB, IE=27.0 II / it / 1-12"x6" TEE, RJxFL15 F2+43 220 I , J II „ / START 13 LT STA F1+02 8 LT 26 L I 1-6 GV, FLxRJ 1-12" 450 BEND, RJ 1-12" 450 BEND, RJ 1 1-FH 24' LT I CASE'8ffi1 � � CB 626 1 / SSMH 6846 1-TB, IE=27.2 STA �F2+65 13' LT 1-TB 4'11 1 1-12 GV, RJ 1-12 INSULATING SLV I 1-DEADMAN I I `+�' 2 3 4 1-TB RIM 4 RI 68620 0.98 III1 II I� I I I N G.., �,� / IE 1.4 RIM 30.98 4' CHUIE=27.5 r�l 6' CHLK v a 1 21.4 26 E 29.6 W, 6" CONC ` 4 CHLK GAIL PROPERTY INACCESSIBLE 6' ON STA FO+97 8 LT S AC/ / / v / 6 H 5' CHLK 5' CHLK-12" 45° BEND,FLGxRJ_27 - - WYP --\ -1-DEADMAN JU P- _ - / U- U - T T u�P 520 - xw LlT -- I -- -T --T--- T - - - - -T- - - -T -- --T --T ----T- s IE=17.9 / NW N_ / / I o 12"DI W o ---cnW C1�= STA FO+84 13'cLT j +0 1 ;� � , ,3� � - 8' a - - 8"W CI - - 8"W CI - - - - - 8"W CI /ate - - - SS - - ss-F2+00_ - ss _ a F3+00 _ _ - F4+0 1-12 ITEE, FLG I 1-12" GV, FLGxFLG 25 IE=23.2 p / / / T' >1 37 \ -'-'- 2-12"GV,FLGxRJ I 14 20 TYP ,/ �/ '� 3DR35SSn --- �� ---- ---- 1-TB i cl OF 3 / / / 3 ~ SHA33 TTUCK AVE S 1 TYP 1@CL, III la I 99 - as - STA F1+24, 12' LT s - r--sD - -- D - -sD -SD-18"PPSD� --- - 1-12" 450 BEND, RJ -� ®I I I 42 � - 1-TB, 1-DEADMAN w / / /DWY - - - -STA F2+32 9' LT - UGH - Tv- - _ - I -/ - - _ -- -T-1-12"450BEND,RI ----- -- - M STA - - - - 10' LT - M c I MIC 2 7 1-12" 450 BEND, RJo 6, "M/GN�r/SON' APT ' .� pq��� 1-TB •�-�� STA F3+10, 9' LT Nc I I I (fi 31 -TB / / / / �.5 CHLK STA F2+23 9' LT 1-12"x6" TEE, RJxFL 35 4' v f - I I 26 / STA F 1 + 16 12' LT A r L1-12" 450 BEND, RJ 1-6" GV FLxRJ c( II , Q I 1-12" 450 BEND, RJ, Nc / / 1 4 �G B 68720 1-TB I � z T / / NC / / OOD RIM .1' N 211 1-FH, 24' LT 0 1-TB 1-DEADMAN Nc/ / IE 28.1 NE, 6" coNc 1-12" GV RJ N p / r IE 28.2 E, 6" CONC I II I c l l / 1-TB, IE=27.5 II (/) I STA F1+88 10' LT / M 31.73SMH 65 / 1-12" 45° BEND, R1 / /\ / % E 21.6 S I I STA F4+04 18 RT ICI / U E 21.6 SE 1-4 x4 TEE, RJ 1 4" 45�E�. 1-TB E22.7NW r c� I I " � � � 12-4 GV DMH 68466 I co I I STA FO+95 38' RT / / / 4' 00 I 2-4 450 BEND 9:F 1 nn nT I I I I � / io RIM22.94N, 1 CON C �r4�-v�-z��rr IE 12-TB i 4��ENDI I I I U 0 / IE 22.9 S, 1 CONC �� ^ I I I I / /// / �/ / /'_%� / \ i I ELEV 24.0 -W, TOP OF 12 ID CONC SS PIPE 136 DEEPS FOR CONTINUATION RECORD DRAWINGS SHOW CONTRACTOR SURVEYED SEE SHEET W-2 STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT P LA N DOCUMENTS FOR ADDITIONAL DETAILS 0 0 10 20 40 60 V7 00 450 BEND MOVED TO SCALE: 1"=20' V7 DROP BELOW FOUND FO X � N DUCT, CASING EXTENDED M W 'n 45 O � ^ W N W M N II 3:p co W .. II a w w V N H H a Lu V7 II Q M w �Lr � � w 40 0 a - UO-can 0 -M of 0' M p 0 0- J- _ d - N N V)m V) (!) _ V) N �p LL ('D W N Cp ,N� N �,� Vi >) _ �O II � II N LL cn N al0 >N ��oEXIST 0w aN 00 O ON 0 II mO 0 0 0 �pN j O II ROW O W X z 0 X XXw x oCw X � L �_U w U -0- 1-4 w 0- II aaa 35 30 31 1 25 F8195 STA FO+86 1-12" 450 BEND, FLGxRJ IE=26.7 20 1 F#i$R STA FO+94 1-12" 450 BEND, RJ IE=19.5 15 FO+80 U)0 X 0� w U 0 IrAPPROX 21' LONG CASING Iam= 24"STEEL CASING, LTF F1+00 F1+20 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY - L -- I- - - - - t - - - --E O - - T - APPROX 15' LONG 0 CASING71-m' Lu 2:> 0 0 12"DI W 12 1-12" INSULATING SLV zA F1+83_ 1T 2'" 450 VERT BEND, RJ STA F2+32 f 490 LF OF 12" CL 52 O 1-12" 450 VERT BEND, RJ REST JOINT DI WATER IE=26.4 Imo¢ IE=27.0 TE- STA F1+24 MAIN WITH POLYWRAP 1-12" 450 BEND, RJ 24"STEEL '-�\STA F2+23 IE=26.4 3E-R4.8 CASING, LTF 1-12" 450 VERT BEND, RJ STA F1+16 STA F1+88 IE=20.4 3E-+9.8 1-12" 450 BEND, RJ 1-12" 450 VERT BEND, RJ IE=19.5 IE=20.3 4 CONSTRUCTION NOTES: < > 1 CONSTRUCTION CL EQUALS R/W CL, SEE STA F4+05, 12' LT SURVEY CONTROL PLAN, SHT G-6 1- GV 1-4"" GV, FLGxRJ TEE, FLGxRJ 3 REMOVE AND REPLACE EXIST STORM TO A I 1-TB I I 300 DISTANCE OF 10 FT ON BOTH SIDES OF PROP v WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND CULV 69111 6' IRON GATE CB 68976 ALIGNMENT IE 31.6 2" PVC UCAB I RIM 30.71 IRON GATE IRON 1.5' CO�C WALL 2 4 SUPPORT SPU WATER IN PLACE PER 1-07.17, DO ac AG 14" NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU DWG _ ITHTO_ U- P - - IJGP- - UGP - - - 00 STD PLAN 350 21 -TIE=25.4- MW-11--�T-----T----T--- - -T- -- T 9 PROPOSED CORROSION PROTECTION FLUSH LL_ MOUNTED TEST STATIONS TYPE FF, SEE 12 DI W -o _ Q'� CORROSION PROTECTION DETAILS, SHT CP-1 �1--- - -�u)N CI -�1 8 W CI -- - �"�I-----8"W CI ---- �� a II F5+00 ,��, 12 CASING PIPE SHALL CONFORM TO STD 4121 SPU - •- - . �- .y,. .� U = SUPPORT DETAILS IN APPENDIX A I SDR 35 SS Z V7 SS - - - -CB 41 2 - i--i w IE-26.5 I► RIM J Lu 14 WATER SERVICES CORP CONNECTIONS SHALL PP SD -- -- ----------18"PP SD-------SD0, =� BE A MIN OF 18" FROM OTHER SERVICES OR _ u FITTINGS DWYI _ T- _� _ _ __ DWY- - T - _d- _ - T _ - Q 15 FH ASSY PER COR STD PLAN 310.1, CLOSE -T - - - - - - -- - - T- - - - EXIST HYDRANT VALVE, REMOVE HYDRANT, 1 VALVE COVER, & VALVE BOX, SALVAGE TO COR AC CD AC OR DISPOSE AS DIRECTED BY CITY ENGINEER CONC RET WALL CONC BLOCK RET WALL 6' CHLK C ATE / SDMH 68468 20 REPLACE EXIST WATER LATERAL AND METER RIM 31.85 IE 22.6 N, 12" CONCI 212 PER COP, STD PLAN 320.1 AND RECONNECT TO // IE 22.6 S, 12" CONC WOOD DECK-"""' EXIST SERVICE IE 23.2 W, 8" CONC n2l REPLACE EXIST WATER LATERAL AND METER WATER SERVICE TABLE SERVICE ADDRESS SIZE APPROX STATION NO. AT MAIN �1 211 SHATTUCK AVE S 411 F4+09, 27 RT �2 305 S 2ND ST 1" F1+70, 28' LT �3 309 S 2ND ST 1" F1+71, 28' LT �4 315 S 2ND ST 1" F1+72, 28' LT �5 220 SHATTUCK AVE 1" F3+58, 24' LT PER COR STD PLAN 320.4 AND RECONNECT TO EXIST SERVICE 26 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS, SHT CP-1 27 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-15 31 SEE SHT W-2 FOR PIPE CONTINUATION 35 FH ASSY PER COR STD PLAN 310.1 36 AIR RELEASE VALVE PER COR STD PLAN 340.3 EXIST WATER TO BE ABANDONED AND/OR 37 REMOVED, SEE SHT D-15 45 99 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 0 40 d � N V7 a N U) x 0 II ~' w a t w_ IL-U4 co Ln u- Q � ---- Vl W Lu zLn i-4w J W = v7 U Q F1+40 F1+60 F1+80 F2+00 F2+20 F2+40 F2+60 F2+80 F3+00 F3+20 F3+40 F3+60 F3+80 F4+00 F4+20 F4+40 F4+60 F4+80 F5+00 F5+20 F5+40 F5+60 F5+80 INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE JAM RECORD 0 Yz 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT 35 30 25 20 15 SHATTUCK AVE S WATER PLAN & PROFILE STA FO+00 TO STA F5+80 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE W-394909 SHEET W-15 JANUARY 2021 81 Of 121 no REVISION CONSTRUCTION NOTES: M 1 N U N H V) V) N z O W LL LL W r-, J W Q O M N O N O \ Ln N N i ,-1 L0 a N i U N a) L0 ra a a 0 c 0 c ry Ln N N i 00 U L �I w 35 30 25 20 15 10 IE 27.4 S, 12" METAL CB 26852 0 I � � STA F6+34 13' LT STA F6+39 13' LT 301 RIM 30.83 1-12" 22.50 BEND, RJ 1-12" 22.50 BEND, RJ IE 26.4 E, 12" CPP IE 26.5 N, 12" CONC Q 1-TB 1-TB IE 26.2 W, 12" CONC I N II STA F6+44 13' LT SSMH 26850 I (Yi - / 1-12" TEE' FLGxRJ (CUT -IN) RIM 0.00 IE -8.6 N,E,S @ C Q I I 27053 z CB 70375 ' 1-12" GV, FLGxRJ RIM 30.62 SSMH 26851 I a I II RIM 30. 2-12" SOLID SLV, RJ IE 29.5 W, 4' RIM 31.22 I 37 p IE 2 N, 12" METAL 1-TB - IE 23.6 E,W @ CL a U) 26751 C NC RIM 29.73 SSMH 69592 -4 P 1ri�- 1IE 26.91 1 -. 1 :: • 16HLK RIM ������ •� • : • `J� A ' O' O ! ' 1 �'5 GATE 6' CHILKGATE MINIM • - �I . 11 v ! - ss PRO- .. 1 . - � ,q ���U� '� ..:►. � 1.� tea-= I a 1 1 s\ �r r) n'1 U ,o m - I QW r,I P TR O CDT== T---- T----_T_I - -=7 T = 88 - gyp. _== - ,-I _ 0 --04-„W CI - - - -8 g 1 "W CI - - LL -T-- -12" I� 12"W -16"W CI-- � _ �7 1 TYP }� - _ - T- o - - - o „ „ 12"W DT-- T==--- I--- V)T----- f„ W DI - - - - 12 'Wp�l - - - 12 W DI - - I - - 12 W DI - - - - - - - T - - - - - T ,. - - - T - - - - - T - - - - .• -� - -F8+00 III - F9+00 o I o F10+00 LU Lu So- S = N_- �- ASS- �S _ I - PIKE 118 { ' d ' w ---- ' =�TT CK AVE Sc-84 SHAD w 24 PP SD I 24" PP SDn J U) III-- - 11 RE C==== SD -� I -SD ----- KB 17 __SD _ _ -SD --- SD - -- Sp 9- -�' 851}PIi�-� - s��-- - �86�0 �z,,Dls I -- - u awly :a��W/POWER AND FLASHER _ _ _ G DWY / DWY '0gU f O TRASHCAN Q - I I P -- ----- STA F6+44 5' LT CD SSMH 69595 1-12 - PLUG, RJ CONC-FILLEQ RIM 31.00 CB 70005 I I � I SD 2669 1-TB IE 22.6 N,S ® CL RIM 29.69 I I J 7' CHLK RIP 21 N,S NW CONC MON IN CASE IE 22.8E IE 28.4 SE, 4" PVC z IE 28.4 NW, 4" PVC � I I a '< IE 12" CONC REESTABLISHED PER DNR SDMH 69907 I CB 70275 IE 26.5 6" CONC 0 ED 27.3 E, " CONC PERMIT 7373 - 18"T X 6"W CONC RIM 30.69 I RIM 29.73 IE 21.8 N,S, 12" CONC I I � IE 27.3 NE, 6" CONC C 5299 IE 23.5 E, 12" CONC I I (y � STA F6+44 10 RT 1= 0 EI 27.8 6 12" META, 1-12" GV, RJ I I (f IE 27.8 W, " METAL 2-12" SOLID SLV, RJ I I I 29690 STAB F6+45 40' RT 220 I I 1-6 SPL, LTF :. 6 SE,' 8" CONC 1-FH, STA F6+79, 40' R �8 E, W/THROUGH NiFL, 1 z UUNU 207 -n NN HYDRANT AND 6" SPOOL REPLACED BY CITY TO 7 EXIST 6" GV IN 5/25/2022 PLAN 0 10 20 40 60 1 1 mlIIIIIIIIIl SCALE: 1"=20' CL� F-v) a-� Lu _ � OU � O U N W a F Lrl N ~ W W m N z a O � II - -0 w II z W H O O ci a- w w .� a _� -w -U EXIST GR @ ROW CL O O 0 --- - - - ---- z w TOP OF SD=24.3 Ln Ln p ° NO W DEFLECTION ,-� LL � Q U REQUIRED '� Q 12"DI W 0 UO w `t V) w w W z xxXXx LU= 4- 4• 2 " �� 5 ° 1AC-P sEP PIP, R9 z V) W i--i W J . � r LU J W (n _ _ V) U Q I� �1�i"i-5 , iIE-ia.5- Q �2�1.59pgpG64pjg)))))) 9.5 f 65 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP F5+80 F6+00 F6+20 F6+40 F6+60 F6+80 F7+00 F7+20 F7+40 F7+60 F7+80 F8+00 F8+20 F8+40 F8+60 F8+80 F9+00 F9+20 F9+40 F9+60 F9+80 F10+00 F10+20 F10+40 F10+60 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE JAM RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT < > 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 5 REMOVE AND REPLACE CATCH BASIN (TYPE 1), REMOVE AND REPLACE EXIST STORM PIPE FROM CATCH BASIN TO 10 FT PAST PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT 10 CONNECT TO EXIST MAIN W/ CUT -IN TEE & VALVE PER COR STD PLAN 300.2 15 FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1. CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX. SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-16 35 30 25 20 15 10 SHATTUCK AVE S WATER PLAN & PROFILE STA F4+80 TO STA F10+60 W-394910 SHEET W-16 82 of 121 no REVISION PROJECT NO.: 18PROJECT NO.: 18-22511SCALE: AS SHOWNIDATE: JANUARY 2021AS SHOWNIDATE: JANUARY 2021 C'D N U V) N z O ne w LL- LL. W r-, J w 0 M N O N O rn a Ln N N L0 a� N 0 Q U i N a� ra a a 0 c 0 ry Ln N N i 00 U L a �I w no Ip , LTA w STA GO+27 9' RT 1-12" 450 BEND, R 1-TB CB 62819 7/11 Z / / ' /' / 220 CB 27447 !� / rlIM301 E4 6" PVC / / /SDtVIH 76973 30.1 NW, 6" CONC ' IE 30.1 SW, 6' CONC /' / / E/ 129.87NE, 6" CONC/ I�E 29.5 S, 6" CON' VW-3 fE 2a.7 w 12" coN¢¢ STA �G2+°59 8' RT 1` 3 / IE 28.8 E, 12" C60NCH 1-12 90 BEND, FLGxRJ�, 17 G TE 1-12" DI SPL, LTF - a J ® STA G2+56, 8' RT 1-12" TAPPING GV, FLG IE 31.1 S, 6 c�NcA y I I - - - - - - U - / =33 INSULATING SLV 2-TB O __ _ TV v / - T 1V 12" TAPPING TEE, FLG + �a I A I d E .4 _ _ _ _ „ _ / /„ M T- Al STA GO+00, 0' RT 11 I I __ O STA Al2+87, 0' RT 4 1AIC 25 26 'WTI I- 1 TYP / 4 - // // - - SD - - MW-32" PP SID Q N 26 - _ WHITWORTH AVE S -G- - G /--— G — — — — —G F- 2 � GO+00 I I'I c� �-Il�jO�0 G1+00 I G2+ 0 / _ _ I_ G3+00� (n w I E=19.2 '� I �Qti I I 0 k. j 0 0 lS S — I/ / /'+ cS�O 3 7 7--- S-- Lu LU LU SSMH 6281 / I I � -, I C / / / RIM32.55 I I I I 12 DIW 12 DIW / `SQ --G -_ i--�w Lu IE26.4E,W®'L I c� — — / / — 12"W DI �— 12"W DI — — 12"W = 61 -- �, I ----- - - - G - - / 60 u I '5811 I 14 DWY � STAG-0+05 9'RT I� 79� —I® I �I' _ — ____- G-� - -__ `L - / A u T T Q 1-12" 90° BEND, RJ I I 8'' TV— `� T / / / BIKE RACK B ACK E �� I n/�• IM 32.48 20 STA G1+82 8' RT /gam — w P AISTA G2+32 8' RT W-41 1 o RAISED PLANTE � I I �, I �; IE 29.s w. s" �oNc 1-12" 45° BEND RJ / / '� 1-12 45 BEND RJ I I �I 9 STA GO+39 9 RT 1 � / `FA U)( I `° I I I U)1 1-12" TEE FLG 1-TB //�° / // 9 1-TB 26 CONNECT TO III M n M i 11 3-12 GV, FLGxRJ Iy / /Q�/ / EXIST 12" W M I I I /� EXI DEADMAN BL CK I o z II 1-TB SDMH 63337 STA G1+90 STA G2+24 8' RT N 8 RT / / / / II 26 L III IM 32.47 1-12" 450 BEND, RJ / / / / / 1-12" 450 BEND, RJ I 32 I I 8.4 S, 6" CONC 321 1-TB / / / / 1-TB / I IE .3 E, 12" CONC I ( 1 I ( (^ 1 I IE 28. W, 12" CONC Ii I III I 1 I� I IE 28.4 E, 4' CONC I� cn•� I \ `� I I STA GO+20 9 RT 1-12A450 BEND, RJ / 1-TB FOR CONTINUATION SEE SHEET W-3 RECORD DRAWINGS SHOW CONTRACTOR P LA N SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN 0 10 20 40 60 LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. p SCALE: 1"=20' REFER TO CONTRACT DOCUMENTS FOR cn ADDITIONAL DETAILS T Ln � rn 45 N a N a 0 a 35 30 25 20 15 10 � t n .. • L D STA GO+69 9' RT 15 tW40 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24 LT 1-TB TOP OF PVC CB 63513 IE=27.0 RIM 32.22 IE 29.9 W, 6" CONC BRICK WALL/PLTR, 2.5' TALL —\ loon WATER SERVICE TABLE SERVICE ADDRESS SIZE APPROX STATION FIELD VERIFIED NO. AT MAIN STATION AT MAIN E319 S 2ND ST 1" G1+29 G1+29 1 M � II O N O II ,w_, � W NJ-ko N ^ N � w Q a i--I Q CO CO H a� Lu U) .� a? a � � � � Q o2S a U) 0 cn a Ln U)� M N to Ln m O > 11 N o0 Z) � �� m a'� 1- Z) � 00 LL C� �z�Ln nz U� ko a �� I-- � O cn Ln Lrn cn F-a O' 00� 00 H O1 a Ln U) N Ln N V) cn N EXIST G R @ d cn V) CO�� cn N Ln ZH l0 z cn N O II � � � O � oC WX xxa X l O II 1--1 II � II � — II O x� W X Lux w x x w� ROW CL O � x � X�xwX� O -- II — O � II Ox w w w w U_ w Lu a w w_ w w_ o- a w w U w w U U w_� -- - -- - APPROX 15' LONG o O APPROX 15' LONG N CASING 32 z w CASING OU (D 12 �� oN Q ' 1 12"DIW [-.- 7\\XI T 12"W w STA GO+27 w 32 o 1-12 45 VERT BEND, RJ STA G1+82 Z 12 z Ln IE=27.2 5 1-12" 450 VERT BEND, RJ N �-+ TA + 5 5 i--i w z N IE=26.4 �C�Zi?•a 1-12" INSULATING SLV J W U) STA G2+31 u 1-12" 450 VERT BEND, RJ IE=25.5 T STEEL U 24" STA GO+20 f 265 LF OF 12" CL 52 STA G1+90 CASING, 1-12 45 VERT BEND, RJ LTF STA G2+24 24" STEEL 1-12" 450 VERT BEND, RJ REST JOINT DI WATER IE=20.5 1-12" 450 VERT BEND, RJ IE=20.5 CASING, LTF IE=20.0 3E-i9.5 MAIN WITH POLYWRAP INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' GO+00 GO+20 GO+40 GO+60 GO+80 G1+00 G1+20 G1+40 G1+60 G1+80 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT G2+00 G2+20 G2+40 G2+60 G2+80 G3+00 G3+20 NOTICE JAM RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET 1 10/26/2022 JJM I RECORD DRAWING NOT TO SCALE NO. I DATE I BY REVISION 45 35 30 25 20 15 10 RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT CONSTRUCTION NOTES: < > 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 3 REMOVE AND REPLACE EXISTING STORM TO A DISTANCE OF 10 FT ON BOTH SIDE OF PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXISTING SLOPE, SIZE, AND ALIGNMENT <V4 > SUPPORT SPU WATER IN PLACE PER 1-07.171 DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL. BACKFILL PIPE BEDDING PER SPU STD PLAN 350 7 GAS TO BE RELOCATED PRIOR TO CONSTRUCTION 8 WATER SERVICES CROSSING SPU SHALL USE KAMCO MUNICIPAL AQUA SHIELD COPPER PIPE 9 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTIONS DETAILS SHT CP-1 12 CASING PIPE SHALL CONFORM TO STD 412 SPU SUPPORT DETAILS IN APPENDIX A FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE 15 HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 17 CONNECT TO EXIST MAIN W/TAPPING TEE & VALVES PER COR STD PLAN 300.1 20 REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE 24 WATER SERVICE TO BE INSTALLED WITH A 2" SADDLE TAP PRIOR TO ABANDONMENT OF 8"W BETWEEN SHATTUCK AVE S AND WHITWORTH AVE S 25 PROPOSED WATER MAY HAVE A CONFLICT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURE TO INSTALL THE WATER UTILITY SUCH THAT FUNCTIONALITY OF THE EXISTING UTILITY IS MAINTAINED UNTIL SUCH TIME AS IT IS ABANDONED 26 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETAILS, SHT CP-1 27 TEMPORARY WATER SERVICE, SEE SHT D-19 32 SEE SHT W-3 FOR PIPE CONTINUATION EXISTING WATER TO BE ABANDONED AND/OR 37 REMOVED, SEE SHT D-19 WHITWORTH AVE S WATER PLAN & PROFILE STA GO+00 TO STA G3+20 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 W-394911 SHEET W-19 83 of 121 CONSTRUCTION NOTES: N 9- U a� U) J N z O w LL LL w r-, J w Q 0 ,--q M N O N O \ O N i Ln N N L0 a) v U7 i Q U N a) U0 ra a a 0 c 0 ry N N i 00 U a) 0 L �I w 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY 0 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 45 Qlim 35 01110 25 oxilm 15 I I rn I I I I I I I M-9 Mum STA G5+45. 6' LT 1-12"x12" TEE, FLGxRJ (CUT -IN) 1-12" GV, FLGxRJ 1-TB 3-12" SOLID SLV, RJ 1-12" GV, RJxRJ / PLAN 0 10 20 40 60 SCALE: 1"=20' AC STA G5+85, 6' LT 1-12" 11.250 BEND, RJ 1-TB 1-44 900 BEND 4"W CI — —- - CONNECT TO EXIST 6" W 1-12"x6" TEE, FLGxRJ 1-12"xA4TEE 1-12" PLUG, RJ 2-TB !i,,1-4" GV, FLGxRJ u 13' METAL & PLASTIC, POWER, 325 "3RD STREET PROFESSIO AL BLDG" STA G5+63 6' LT 1-12" 11.250 BEND, RJ 1-TB STA G5+58 6' EL I 1-12" 11.250 BEND, RJ II 1-TB II „� STA G5+46, 30' RT 1-6" SPL, LTF 1-FH, STA G5+81, 31 RT HYDRANT AND 6" SPOOL REPLACED BY CITY TO EXIST 6" GV ON 9/2/2021 M N (n l0 d EXIST GR @ N O N ROW CL w Ln -, V) cn u, O U) uX w ww wU wD- rn — --- ww o EXIST 4" Ln Z w Lu U) = D Q DID NOT INSTALL BENDS + --" -- -- -BEMB, R3 T1T�7TTr T r 11 1 It f 80 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 0 G3+20 G3+40 G3+60 G3+80 G4+00 G4+20 G4+40 G4+60 G4+80 G5+00 G5+20 G5+40 G5+60 G5+80 G6+00 G6+20 G6+40 G6+60 NOTICE JAM 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT RECORD DRAWINGS SEE NOTE ON murraVSMi mt COVER SHEET EA 45 Qi7 wiz 25 1wil RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT 15 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-20 WHITWORTH AVE S WATER PLAN & PROFILE STA G3+20 TO STA G6+00 W-394912 SHEET W-20 84 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 r`nKICTD 1 1r`TTrlKI K1r1TCC - M i N ►i U a� Ln 5- Ln N z O Ln ILL W 7 J W a 00 M M N 0 N 0 N Ln N 0 Ln N N i i Ln N a� t U7 0 Q U i N Q) Ln ra a a c 0 c ry Ln N N i 00 Ln V a �I W no 55 50 45 .s 35 30 25 CB 30024 RIM 43.10 IE 38.7 NE, 6" CONC IE 38.5 SW, 6" CONC 4'CHLK CONNECT TO 1 EXIST 8" W CB 30025 RIM 43.27 IE 41. NE, 6" IRON IE=41.25 0RC.351 13 STA L1+46 10' LT 1-12"X2" TEE -1-2" GV �H4 44 4 12"DI W STA L2+02 10, LT 1-12"x8" TEE, RJxFLG 1-12" GV, RJ 2-8" 450 BENDS, RJ 1-8" SOLID SLV, RJ 1-8" GV, RJxFLG 100 3-TB 1.5' CONC WALL STA L3+60, 11' LT 8' BUS GN 7BUS SHELTER BENCH 1-12" INSULATING SLV TRASHCAN 1 I i 64 0 45 �1/� �L1 0 I — — — L2+00 lz /14—�— ` ` I 98 MILL AVE S � �— �— —G ———— G — — — —— DWY I C DWY LT ,V- o/ 1 x 1L c CONC WALL WIC APPROXIMATE LOCATION OF BRIDGE APPROACH SIB STA L1+35 10' LT 99 77 Ac _1-12" 450 BEND, RJ AC P AC 1-12" GV, RJ 2 20 1-TB ' IE=37.9 } B 3 6 0 STA L 1 +11 24' RT IE 42.0 NE, 6" c1-12 X8"TEE, RJxFL (ROLLED DOWN) C DE INEANR ` \ ` K 1-8" 450 BEND, RJ 1023 ARNI POSTS W-4 1-8" 900 BEND, RJ O 1-8" SOLID SLV, RJ & COLUMNS ` 1-12" PLUG, RF , 5 IR AT 1-TB \ ` 1-DEADMAN ON EXIST WATER MAIN 1 WATER SERVICE TABLE SERVICE ADDRESS SIZE APPROX STATION FIELD VERIFIED NO. AT MAIN STATION AT MAIN EIRRIGATION 1.5" L1+46, 10' LT L1+461 10' LT El1023 BRONSON WAY 1" L2+45, 11' LT L2+45, 23' RT E1010 BRONSON WAY 1" L2+93, 11' LT L2+93, 23' RT PLAN 0 10 20 40 60 SCALE: 1"=20' STA L4+07, 11' LT ' 1-12" 450 BEND, RJ 1-12" INSULATING SLV, RJR 1-TB `yam STA L4+03, 11' LT 1-12" 450 BEND, RJ L 1-TB W-42 SSMH 85682 RIM 46.04 Q 1 8.2 NE,E,S-W @ CL .� P XING AL IC 9 Al 1 STA L4+ 18 11' LT II I i 1-12" 22.50 BEND, RJ I (n o II 1-TB I SDMH 85661 Q I 11 RIM 45.37 i TI STA L4+25 11' LT N I II 1-12" 450 BEND, RJ I V) I !� ROTATED DOWN o O I I i 1-TB RIM 44.97 O o I IE 42.9 NW, 8" CONC IF a? q N. 8" CONC _ T I I STA L4+71 11' RT 1-12" INSULATING SLV I G 9 37 O + \ 6„ J� ! 4 � � — N 65 I 6 4,)46� ' �'- 6FL 3 , Q + .� 3 W Lu i -, SS S£ 2iaS „8 - 38 - 7�— SS aalJ= ZT� N, . z Lu Ju fly DWY n I T --- �26TV Q Ac cKIAI 3 6' CHLK GATE 1 I I CBP8D5 21M 44. 2 CONNECT TO E 42.0 S, 8" CONC I N E 42.0 N, 8" CONC STA L3+98 11 LT EXIST 12 sW 85622 1-12"CROSS, RJxFLG CAP EXIST TEE 2-12" GV, RJxFLG 1 i RIM �45.46 CONC STA L4+50 11 RT „ 2-12" INSULATING SLV, RJ I I I 1-12" 450 BEND, R11 " CONIC IE=39.9 1-TB III IE=38.9 CONC. MON. IN CASE o REESTABLISHED PER DNR I `` STA L4+75, 11' RT ` PERMIT 7373 - 18"T X 6"W I I IN'• L 1-12"x6" TEE, RJXFL I I I I I I D 1-6" GV, FLxRJ STA L3+96, 0 RT A I l i l l 0 1-FH, 29' RT } 1 _ 8VI R3 I• �za 1-TB RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS oC co H �I LU � �I U7� %1 /�.,1 rn Ou- (n cn (n oC U ki N M o � II n a LU nI X F- ° a ° W a o �o a :: i Ln wz ~ X F- O (Doo 00 F- � U7 � Z) � U N --1 LaL O .X w W U) z ,--i co Ln iI1 0 7-11 a � X 0 O n m X OOO II X a 0C X oC jj X X X 11-- D A Y O oC OW 11 oC U W w W EXIST GR ROW CL @ a W O a w n w w w a w W w w w w O i U w _,a W z z Ov O O ' U L 00 -- ---- --- W > o o 0 _ 19 io J 0 0 o o Ov = - IF = ------ 0 w 12"DI W -- LU w z z c=n STA L3+60 STA L4+03 STA L4+71 i--i W " STA L1+�11 1-12" INSULATING SLV -1 450 VERTT BEND RJ 1-12" INSULATING SLV W = (n 1-8 45 COMPOUND BEND, RJ I_ 19A U 1-8" 900 COMPOUND BEND, RJ f 345 LF OF 12" CL 52 IE=MATCH EXIST WATER INVERT REST JOINT DI WATER Q 1T 2" 450 VERT BEND, RJ MAIN WITH POLYWRAP IE=37.5 FE--9z8 STA L4+18 1-12" 22.50 BEND, RJ IE=37.5 I�� STA L4+25 1-12" 450 COMPOUND BEND, RJ IE=39.3 JE-40._ INSTALL J INT BONDS AND ANOD S FOR EACH IPE LENGTH AND FITTI G LO+00 LO+20 LO+40 LO+60 LO+80 L1+00 L1+20 L1+40 L1+60 L1+80 L2+00 L2+20 L2+40 L2+60 L2+80 L3+00 L3+20 L3+40 L3+60 L3+80 L4+00 L4+20 L4+40 L4+60 L4+80 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY REVISION NOTICE JAM RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murraysmi IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE i RENTON DOWNTOWN � UTILITY IMPROVEMENTS PROJECT 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 2 SEE SHT G-6 FOR STATION CL NORTHING AND EASTINGS 3 REMOVE AND REPLACE EXIST STORM TO A DISTANCE OF 10 FT ON BOTH SIDES OF PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT 4 SUPPORT SPU WATER IN PLACE PER 1-07.171 DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU STD PLAN 350 9 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTION DETS 13 REPLACE EXISTING WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE 14 WATER SERVICES CORP CONNECTIONS SHALL BE A MIN OF 18" FROM OTHER SERVICES OR FITTINGS 19 PLACE DENSE FOAM CUSHION AT ALL UTILITY CROSSINGS WHERE WATERMAIN CROSSES WITHIN 6" ABOVE/BELOW ANOTHER UTILITY 20 REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE 26 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS, SHT CP-1 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-25 38 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 98 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF EXIST UTILITY 55 gg CONCRETE DEAD MAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 50 45 35 30 25 MILL AVE S WATER PLAN & PROFILE STA LO+00 TO STA L4+80 PROJECT NO.: 18-2251 1 SCALE: AS SHOWN DATE: JANUARY 2021 W-394913 SHEET W-25 85 of 121 N i 7 U N V) J V) N z O V) ne w LL LL w J W a O M N O N O N O a Ln N N ,-1 L0 4-+ a) v / 0 a U / N Q) L0 ru L d d 0 c 0 c ry N N / 00 / U L �I w / 55 50 1 45 .W 35 30 25 SDMH 79859 R RIM 46.89 0 \ \ \ \ IE 43.7 SW, 8" CONC IF 42.4 N, 6" CONC \ S1 x \ \ � \ IF 42.4 NW, 6" CONC �� �5 S� \ IE 40.4 E, 12" CONC 32 R9 S s1 \ CB 80056 j a y IE 4. 8" CONC \ RIM 46.23 KB-7' % �\ .4 C�ONC \ \ IF 43.0 S, 8" C0�4C IVY D1 SP � �� '�9 � R 46. � IE 5 \ 0 N C SSM ,� AIM VY \ I \ \ \\ -48 IF 4 3 37 CONNECT TO OI -4 6- Ad RK / AC BARK _ EXIST 12" W Op - - 3' - _ _ - - - - _ as _ \ W STA L8+ 19, 1' LT l --�-------- - - \ a - - - - 8"W cl - - - 4 - 6"W CI - - - - - 6"W CI - - 6 'W-cl- - - pw� W CI S - - - 6 W C MILL AVE S - - - - - 6 'w CI 6"Wd l - -------- J �� 12" PP SD - 12"PP SD - _ _ _ _ \ 1 Ty P W-4 c� Q -- --4 - __----MIC 268 --� --\----�j--r -- >T' � CRPL#3 66" STL 0 CRPL#3 66" STL \ \ �(n -- - - L5+00 .•.•.•. n`\w L6+00L7+00 L8+00 _ --L9+` - 00 00 V) Z - - 284 LF 12 CIPP SS ... .. ..-US - .- - - - - - �.•v .... .... ... '134.LF ' 13 SS w J 12"DIW .... ... •.80 co-••I�'• - _ - s Ln= 12 DIW _qv12 DIW s \ M Ur�Gfl- 45 8"DI SD ---SD --SD - - - -- -- � �\ �-- T = _ = U S U� _ _- =.-U _ - - DWY UGP- - - - �P- DWY - 20 _T- 3�\' -3 , AG o CB 805 05 46- ORN MENTAL FOUNT 1 2 1�1 CB 80213 � RIM 45.04 STA L7+50 11 RT 42.2 N, 8" CONC 2.0 S, 8" CMP IE 4SIlI W, 6" CONC RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IF 42.8 N, 8" CMP IF 42.8 W, 8" CMP SSMH 80203 / RIM 46.20 IF 40.1 N,S @ CL 211 W/RR-XING AND "NO RIGHT" SIGNAGE 15 RIM 1-12"x6" TEE, RJxFL E440 S , " CONC 1-6" GV, FLxRJ IF .0 NW, 8 NC 1-FH, 29' RT SSMH 79860 1-TB RIM 46 71 WATER SERVICE TABLE SERVICE APPROX STATION FIELD VERIFIED NO. ADDRESS SIZE AT MAIN STATION AT MAIN �1 IRRIGATION 1.5" L7+631 12' RT L7+611 29- RT \ 235 MILL AVE S 1" L7+60, 12' RT L7+641 28- RT n- - - - _ _ _ - - -- --• -- IF 41.0 SW,N @ CL STA L8+ 13, 11' RT 1-12" 450 BEND, RJ 1-TB IE=40.2 PLAN 0 10 20 40 60 SCALE: 1"=20' MH 79861 IM 46.40 E41.2S,NE@CL AC SSMH 80291 RIM 46.94 IF 41.4 N,S @ CL \ STA L8+47 17' RT 17 1-24"x12" TEE, FLG (TAPPING) \ 1-12 GV,FLGxRJ C CD w \ 1-TB o N Of w Nx\ IE=37.0 \ o 0 ``STA L8+39 23' RT o 1-12" 450 BEND, RJ 1-12" SOLID SLV, RJ �� I \ 1-TB 0 \ \I STA L8+23 21' RT \ 1-12" 450 BEND, RJ RAMP \ 1-TB \ IE=39.3 L4+80 L5+00 L5+20 L5+40 L5+60 L5+80 L6+00 L6+20 L6+40 L6+60 L6+80 L7+00 L7+20 L7+40 L7+60 L7+80 L8+00 L8+20 L8+40 L8+60 L8+80 L9+00 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE JAM RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT 55 50 45 .O 35 30 25 CONSTRUCTION NOTES: 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 5 REMOVE AND REPLACE CATCH BASIN (TYPE 1), REMOVE AND REPLACE EXIST STORM PIPE FROM CATCH BASIN TO 10 FT PAST PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT 13 REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE 17 CONNECT TO EXIST MAIN W/TAPPING TEE & VALVES PER COR STD PLAN 300.1 20 REPLACE EXISTING WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-26 MILL AVE S WATER PLAN & PROFILE STA L4+80 TO STA L9+00 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 W-394914 SHEET W-26 86 of 121 no REVISION N i U (3) V) N z O V) ne w a LL w r-, J w Q 0 M N O N O ,-1 ,-1 N 0) i a Ln N N L0 a� N v7 i p Q U i N ra a a p 0 a� ry N N i 00 U L a P_I w 1\ 110/26/20221 JJM I RECORD DRAWING NO.1 DATE I BY STA 1 + 0 5 12' LT 154-12"x6" STA QO+44, 16' LT 1-12" CROSS, FLG 4-12" GV, FLGxRJ 1 TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 25' LT STA 0+96 12' LT PK'2 1-TB R1-12" 450 BEND, RJ-' , 1-5'x5' CONC PAD IE1-TB o STA 0+31 17' LT SDMH 65164 II , IM 29.54 II 1 1-12"x8" RDCR. RJxRJ 1 24.7 E, 8" CPP - 1-8" SOLID SLV, RJ _ IE : N*PP — ---- IE 25.1 w nic CONNECT TO EXIST 8" W - - IRK S 165 C RIM 29.41 IE 21.1 S, 24" CPP W-40 IE 21.2 N, 24" CPP Q +�� _ 25.6 LAKEAVES� — —aS —/ ==fi_uC�—' — — STA QO+51, 151 LT 1-12" 450 BEND, RJ 1-TB STA QO+55, 15' LT / 1-12" 450 BEND, RJ I 1-TB RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS i m 35 "Im 25 rP41A 15 99 SEE SHEET W-1 FOR CONTINUATION V I I I III 00 I I IIII I I I I I\ 27 I I I I I I I I z I l l p I i �, w MW-10 N N I I II I 1 I I d r LU I 1 4 I II'' I STA 1 + 2 5 10' LT I lJ� III 8" RDCR RJxRJ cl CONNECT TO Gill � � �11►�'=n it , � ��. ♦w� z I_ I'1 II CONC MON IN CASE , REESTABLISHED PER DNR ° -do a- PERMIT 7373 - 18"T X 6"W 0- I I� � I� I� I I ICI I °_� I I I� 0 I a �II� I I 1 W-4 7� � I 1 i RE I p o-STA Q1+LLJ 20 I �� w w STA A4+ 14 I a l I I ,--� U7 CB 65442 1 I 1 I I ICB 5 44 RIM 30.12 I I I 1 RIM 09.96 i I I I IE 28.4 NE, 8" METAL CD I CD IIE 18.7 6 CO�1C CB 65166 AC � DV�Y I \ ' I I I I I RIM 29.10 STA 0+92 13' LT I �1. aSTA Q1+00 I I IE 27.4 NE, 8" CONC 1-12" 450 BEND, RJ I 1 STA IA4�+12 1-TB ! I I I I I I I I I I 1 -dn- :\n 1_ I I I I I 100N. FOR CONTINUATION SEE SHEET W-1 3^P WY ?n V' � U O O' O� O, � M. al _ PLAN 0 10 20 40 60 SCALE: 1"=20' ue (DLn LO (� � = U) U 60 2 I— 00 O 00 00 ('D 00 N (h - 00 U Lu 00 ZLn c) cn (n N cn Ln N cn Ln cn in Ln Ln M Z EXIST G R @ OX � X X Xw X wX XX X Xa O ��u0X ROW U w 0-1 w w w w w w w w w a a U w �— _ n 33 EXIST 8" 0 � EXIST 8' W STA Q+i-rrt STA QO+59 RJ 12"DI STA QO+96 1-12" 450 BEND, IE=25.2 8 1-12" 450 BEND, RJ IE=25.1 4E-R5,+ STA STA QO+61 STA QO+92 1-12" 450 BEND, RJ 1-12" 450 BEND, RJ IE=23.2 I--r'• IE=23.1 4 QO+00 QO+20 QO+40 QO+60 / QO+80 f 90 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP NOTICE JAM 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE Q1+00 Q1+20 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT Q1+40 Q1+60 Q1+80 Q2+00 RECORD DRAWINGS SEE NOTE ON murra sm� COVER SHEET CIS i 35 30 25 lw( 15 RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT CONSTRUCTION NOTES: 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 15 FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 27 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-29 33 SEE SHT W-1 FOR PIPE CONTINUATION 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-29 99 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION LAKE AVE S WATER PLAN & PROFILE STA QO+00 TO STA Q2+00 W-394915 SHEET W-29 87 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 CONSTRUCTION NOTES: I N - U (3) V) N z O V) ne w w w w J w a O ,--q M N O N O O M a Ln N N i L0 Q) Q i N Q) ra a a 0 c 0 ry N N i 00 U L �I w SEE SHEET W-3 FOR CONTINUATION CONTRACTOR TO ROTATE 11 1� 1 I 1 450 BEND AS NEEDED TO I I�� I I � 1 MAKE CONNECTION Ih 1 �•' D — I � APPROX LOCATION OF EXIST 6"W I - — — WI I � � C/� �� I CONNECT TO EXIST 6" W I� I _ cn HIGH SCHOOL N ACCESS ROAD w-4 2 A-n c ° rQ + 0 I I STA SO+94 I o •c 0 1I•-� 1-12"x8" RDCR 2-8" 45° VERT BENDI /�� I I Q__II 1 44 1 00 I W , 1 cSTA A r; 42,-- T� I U I STA S1+00, 0' LT = STA A11+48, 11' LT 11-12" TEE, FLG I I I I � 4 1 I 13-12" GV, FLGxRJ > �I 99 37' 1 111-TB ail 1 I I II 4 I I o 8"DIY I III I I -- as 11 c/) i— GP I n I �' 99 1 1 I I STA SO+66, 0 RT I 1 +R"x8" 1-8"x6" RDCR, RJ 1-6" 450 BEND, RJ 1-6" SOLID SLV, RJ w I III 1-TB RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE I BY PROVIDE TEMPORARY SUPPORT AND PROTECT EXIST FO DUCT DURING CONSTRUCTION 0 FOR CONTINUATION SEE SHEET W-3 PLAN 0 10 20 40 60 SCALE: 1"=20' 2 SEE SHT G-6 FOR STATION CL NORTHING AND EASTINGS 25 PROPOSED WATER MAY HAVE A CONFLICT WITH EXIST UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURE TO INSTALL THE WATER UTILITY SUCH THAT FUNCTIONALITY OF THE EXIST UTILITY IS MAINTAINED UNTIL SUCH TIME AS IT IS ABANDONED 32 SEE SHT W-3 FOR PIPE CONTINUATION 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-3 99 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALL PRIOR TO FINAL CONNECTION U7 N ,-1 O a0 � U•) 11 Lu x X < � < , w 40 a � 40 EXIST GR @ w ~ D co Oo co 00 N Ln ROW CL w Z � (n UO Ln N V N a N OO U X w ,'_, X w X X w X w 11 w 35 a 35 bo 30 EXIST 6" 30 —ME 32 t V911. 0 25 25 z a f 35 LF OF 8" CL 52 - REST JOINT DI WATER 25 ,�.-' <'. f,-' MAIN WITH POLYWRAP 20 20 SO+20 SO+40 SO+60 SO+80 S1+00 DUCT BANK FOUND APPROX 4.5' DEEP. 8" W RUN ABOVE • _ W/ FOAM PAD, SEE PHOTO PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT W-394916 NOTICE JAM RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN m rra SMI IF THIS BAR DOES SEE NOTE ON mt NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE EA RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT RENTON HIGH SCHOOL WATER PLAN & PROFILE STA SO+00 TO STA S1+00 SHEET W-30 88 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 N i■ i L U N (n J V) N z O V) ne w ILL ILL J W Q O ,--q M N O N O M i Ln N N L0 a) v 0 Q U N Q) L0 ru L d a 0 c 0 ry N N i 00 U L �I w RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS =_-so-1 Tom- - -cp -rt 80 --G— --G ----3:—GI 1 34 I 1 I I SPIKEO'l -METAL & PLA ® I I I I / "BURGER TOWN" a I s l I I 601 \ o II c ] AC 37 STA R1+00,IO LT 1 1 TYP 11 I 1 AC�j C W-43 I I I I --- 4 01 I I R1+ i CONC MON IN CASE _ REESTABLISHED PER DNR �I LR0+83 �, PERMIT 7373 - 18"T X 6"W I STA RO+94 1' RT 45® �46 10 1-12"x12" TEE, FLG CUT -IN v� — v- — — T — — — — ( ) 1138 �47� 2-SOLID SLV, RJ I =3 3-12" GV, FLGxRJ 1-TB III "^^ � II :SS 45 i 35 30 25 20 GS Idh�ZT 1. KB-10' \ I. _ M - - I I I I I W � M V / a' a I I DWY - N I I o � in � I• o 4' IRON Fr,. N i PE SIGNI L I � I AC I I o CONC FENCE FOOTING (TYP) I EXPOSED 0.5" CONDUIT IDW AC I I PLAN 0 10 20 40 60 SCALE: 1"=20' TIC, W/POWER, STA R1+92 16' LT STAB R+ 1-88r 1-6 900BEND, RJ 141900 BEND ROTATED UP 1-6" SOLID SLV, RJ 1-41L SOLID SLV 1-TB IE=34.3 U) (n N � � n I O ii Ill n J — W-4 CONNECT TO EXIST 6" W R 0 - STA R1+92 6- LT 2-6" 450 VERT BEND SMITHERS AVE S STA R1+92, 2' RT STA R+ 1-8r8r 1-12" PLUG, RJ 1 1-4" GV, FLGxRJ 1-Fil GV 1-12"x6" TEE, RJxFLG 1-12"xAPLL TEE 2-TB STA R1+79, 2' RT 1-12"x6" TEE, RJxFLG 6 GV, FLGxRJ 1-FIRE HYDRANT (20' LT) i V � Q (n U N U T--i = U z L � a M � V) a M z U Ow LUwLU a ww a ° Ow` Ln EXIST GR @ ROW CL ' z w EX IST 6"W+¢ =W 0 O o U ' n f 95 LF OF 12" CL 52 7' REST JOINT DI WATER MAIN WITH POLYWRAP RO+80 R1+00 R1+20 R1+40 R1+60 R1+80 R2+00 R2+20 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE SEO RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murrar!,vsmilh IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET 1 10/26/2022 JJM RECORD DRAWING NOT TO SCALE NO. I DATE I BY I REVISION EA 45 35 30 25 20 RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT CONSTRUCTION NOTES: 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 10 CONNECT TO EXIST MAIN WITH CUT -IN TEE & VALVE PER COR STD PLAN 300.2 15 FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER 19 PROVIDE DENSE FOAM CUSHION AT ALL UTILITY CROSSINGS WHERE WATERMAIN CROSSES WITHIN 6" ABOVE/BELOW ANOTHER UTILITY 37 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-31 38 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION SMITHERS AVE S WATER PLAN & PROFILE STA RO+00 TO STA R1+00 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021 W-394917 SHEET W-31 89 of 121 N i U a) V) N z O w LL LL w r-, J W a N N O (10 N O N I O ,-1 ,-1 0 0) O w 0 i Ln N N i ,-1 Ln a a) 0 a i N a) Ln ra 0- 0 r= O CII no r EXIST FH TO BE REMOVED AND VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG NEW SERVICE AND VALVE REPLACE WITH NEW FH AT FINAL TO BE INSTALLED ON CONNECTION TO EXIST 8" CI W u� 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW -OFF EXISTING 12"DI W, SEE VERTICAL CROSS (MJxFL) FOR��POLYPIGGING S 2ND ST III - 1-TEMP TB SHT W-3 1-BLIND FLANGE ON TOP W/ 2 TAPS & 2 PLUG N 1-BLIND FLANGE ON BOTTOM 1-8" PLUG, RJ W/2" TAP & 2" BLOW -OFF Y 1-PLUG (MJ) W/2" TAP & 2" BLOW -OFF 1-TEMP TB 1-TB 12" DI W 12" DI W CRPL#3 66" STL W - 1-12" PLUG, RJ W/2" TAP & 2" BLOW -OFF — — — — — — — 1-TEMP TB _ 1-12 PLUG, RJ W/2 TAP & 2 BLOW -OFF O V) 1-TEMP TB > Lu 1-8" PLUG, RJ W/2" TAP & 2" BLOW -OFF �_ Q 0 '3:_ 1-TEMP TB > N REMOVE > Q VALVES 3 LJJ w �- S 2ND ST FUTURE 12" DI J N 12" DI W BY OTHERS u -12" DI W 0 N -------------------- CUT & CAP 12" DI W CRPL#3 66" STL W — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — _ 0 S 2ND ST \ N \I ------------- V' ------ — 1-12" PLUG, RJ W/2" TAP & 2" B W-OFF — — — — CRPL#2 51.5" STL W S 2ND ST 1-TEMP TB POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION TA A4+24 S , 4' RT I STA Q1+05, 12' LT S 2ND ST CONNECT TO EXIST 8" (BY CITY FORCES) 1-12"x8" RDCR, RJxRJ 1-8" SOLID SLV, RJ ---------------------------- __________ �--12" DI W �� 12 DI W�.l (.!) TEMP WATER ^ N SERVICE — - CRPL#3 66 STL W " - — — — — — — — Lu ri — — — — — — —— — — — — — — — — — — — - trJ > LLJ CO ADMAN N N BLOCKING PER p T' � Q Jkk TLJ DETAIL ON W-44 ''; CONNECT TO EXIST 8" (BY CITY FORCES) .-i +-i 2-6" 450 BEND R7 1-12"x8" RDCR, RJxRJ 1-8" SOLID SLV, RJ STA Al2+78, 39RT .� INSTALL 2" PLUG ON TOP OF STA GO+69, 9' RT BLIND FLANGE AFTER '-' STA Q0+44, 16' LT S 2ND ST 30'-4" REMOVAL OF POLYPIG �o u 0 12" DI W 12" DI w �p ao - Npr Ln 12" DI W — — — — — — — — — — — — CRPL#3 66" STL W 1 — — — — — — — — — — — — — O STA AO+96, 5' RT — — — — — — — — — — — w \ FUTURE 12" DI — — — — — — — -- _ o Q BY OTHERS S 2ND ST CONNECT TO EXIST 12" (BY CITY FORCES) — — — — 1-12" INSULATED SOLID SLV, RJ FINAL CONFIGURATION FINAL CONFIGURATION FINAL CONFIGURATION FINAL CONFIGURATION CONNECTION DETAIL CONNECTION DETAIL CONNECTION DETAIL CONNECTION DETAIL rD A B c SCALE: NTS BASED ON STD 300.6 W-1 SCALE: NTS BASED ON STD 300.6 & 300.5 W-29 SCALE: NTS BASED ON STD 300.6 & 300.5 W-29 SCALE:NTS BASED ON STD 300.E & 300.5 �-3 W-394918 NOTICE 0 �z 1 JAM RECORD DRAWINGS RENTON DOWNTOWN SHEET DESIGNED A SEE NOTE ON COVER SHEET murra sm� ® UTILITY U IMPROVEMENTS PROJECT WATER CONNECTION DETAILS - 1 W-40 90 Of 121 IF THIS BAR DOES NOT MEASURE 1" EN DRAWING IS T NOT TO SCALE DRAWN TTT CHECKED Di 10/26/2022 JJM RECORD DRAWING NO. DATE BY REVISION PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: JANUARY 2021 M N ►- U a� U) N z O V) w LL LL w r-, J W Q N N O M N O N O 0) O w 0 Q Ln N N i 06 a� a� U7 Q i N a) r� a a 0 0 Ln N N i 00 i U 4J 0 a �I W i no VERTICAL CROSS (MJxFL) FOR POLYPIGGING (� / 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG I \ 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW -OFF CUT & CAP 1-TEMP TB ry 0 N �' REMOVE VALVES (2) T 12 DI W 'mw U) W VERTICAL CROSS (MJxFL) FOR POLYPIGGING CUT IN: (BY CITY FORCES) > Q 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-12" TEE, FLGxRJ 2-12" GV, RJ S 3RD ST 1-12" PLUG, RJ W/2" Q N 1-BLIND FLANGE ON BOTTOM TAP & 2" BLOW -OFF Y � 1-PLUG (MI) W/2" TAP & 2" BLOW -OFF 2-12 SOLID SLV, RJ 1-TEMP TB U 1-TEMP TB 1-TB 1-TEMP TB N W Q N > 2:- �� �� 1-12" PLUG, RJ W/2" 1 12 PLUG, RJ W/2 TAP TAP & 2 BLOW -OFF & 2" BLOW -OFF 1-TEMP TB = 1-TEMP TB AC � CUT &CAP REMOVE VALVE 2 n ° CONNECT TO EXIST 12" (BY 12"DI W — —12"DI w --�W CITY FORCES) S 3RD ST 1-1212" TAPPING TEE, FLG 1-12" TAPPING GV, FLGx RJ 4" DI W 1-12" SPL, LTF o CUT IN: (BY CITY FORCES) 1-12" 900 BEND, RJxRJ 1-12" TEE, RJxFLG 2-TB 1-GV, RJxFLG I 2-12" SOLID SLV, RJ 1-TB 1-4" PLUG, RJ W/2" TAP & 2" BLOW -OFF 1-TEMP TB J POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION II STA G5+45, 6' LT 2-8" BLIND FLANGE V 2-TB I u � LLB U) QN �1 = Q S3RD ST I � � N 12 DI W o u N J F_ .-I N ~ _ Q CONNECT TO PROP 12" (BY CITY FORCES) CONNECT TO EXIST 12" _ " 2-12 SOLID SLV, R] BY CITY FORCES) � > U) 1-22.5" VERT BEND, RJ 1-12 SOLID SLV, RJ - � Q 1-TB Id N � No CONNECT TO EXIST 12" 1-12" BLIND FLANGE 4'-4" (BY CITY FORCES) 1-12" INSULATED SOLID SLV, RJ 1-TB L�J AC 11'-8" STA F6+44, IT LT STA G2+59, 8' RT 12°DI w 12°DI w- W�— CUT IN: (BY CITY FORCES) 1-GV, RJxFLG S 3RD ST 2-12" SOLID SLV, RJ u > 6" 00 CONNECT TO EXISTS (BY CITY FORCES) 1-12" SOLID SLV, RJ FINAL CONFIGURATION EINAL CONFIGURATION FINAL CONFIGURATION CONNECTION DETAIL CONNECTION DETAIL CONNECTION DETAIL rH E SCALE: NTS BASED ON STD 300.6 & 300.1 W-19 SCALE: NTS BASED ON STD 300.5 1 W-16 SCALE:NTS BASED ON STD 300.5 W-20 W-394919 NOTICE 0 �z 1 JAM RECORD DRAWINGS RENTON DOWNTOWN ® UTILITY U WATER CONNECTION DETAILS - 2 SHEET W-41 DESIGNED A IF THIS BAR DOES NOT MEASURE 1" DRAWN TTT SEE NOTE ON murraysmi '� IMPROVEMENTS THEN DRAWING IS NOT TO SCALE COVER SHEET • PROJECT 91 Of 121 CHECKED A 10/26/2022 JJM RECORD DRAWING NO. DATE BY REVISION PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: JANUARY 2021 IZI- CM N ►i U a� U) J N z O V) w LL LL w r-, J W Q N N O M N 0 N 0 N 0 O w 0 Ln N N i 06 U7 Q i N a) r� a a 0 0 Ln N N i 0 i U 0 a �I w i no w \Lu zz_ / > N > 00 ' 3; J REMOVE VALVE 00 w _ �RTICA Y IG ING SS (MJxFL) �`OR 12°DI w— AA0 0 a J ' -BLIND LANGE ON TOP W/ 2" ' 12"DI w 0` T S & 2� PLUG - - - - - - - - _ g VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1_12" PLUG, RJ 1-BLIND LANGE ON BOTTOM VERTICAL CROSS (MJxFL) 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLU 1 TEMP TB 1-PLU ( J) W/2" TAP & 2" - - FOR POLYPIGGING I 1-BLIND FLANGE ON BOTTOM I BLOW-0 1-TEMP TI 1-BLIND FLANGE ON TOP W/ �� S 2 N D ST • 1-PLUG (MJ) W/2" TAP & 2" BLOW -OFF 2" TAPS & 2" PLUG 1-TEMP TB F CB 3 OH- 1-BLIND FLANGE ON BOTTOM � �� I 1-PLUG (MJ) W/2" TAP & 2" RIM 4 3.2i B \\kA \\ IE 41.7 NI MP TB c� CUT IN: (BY CITY FORCES) 12"x12" CROSS, RJxFL / UGP- - - 2-12" GV, RJxFL / W� , �G-p= ' W - - - - - \ 2-12" INSULATING SLV, RJ 301 �C)_ AM 4 0 I ,,pti \ 1 [ ] -- ``�v CONNECT TO EXIST 24" (BY CITY FORCES) .0 N E C ' CON C I� �ti I� I w 1-24"x12" TAPPING TEE FLG 1-TAPPING GV, FLGxRJ I 1-TB G� I I I N POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION POTENTIAL TESTING CONFIGURATION (\1 / L 1 (f) / 00 w > Q 3: /It� p = (� T w w > I \ CUT &CAP `� r\j > �w J Q , ( J `� I Q AA``Py J J � STA L1+11, 24' RT 1-8" BLIND FLANGE 1-TB I J ~ Vv 1 I --I CONNECT TO EXIST 8" CITY FORCES) � (BY STA L3+98, 11' LT 1-12 X8"TEE, RJxFL (ROLLED DOWN) lb I� oo o + 1-8" 450 BEND, RJ 1-8" 900 BEND, RJ 12"DI W— a12"DI Wl 1-8" SOLID SLV RJ - - - - - _ _ 1-12" PLUG, RJ" 1-TB I CONNECT TO PROP 12 (BY CITY FORCES) 1-DEADMAN - - - - - - _ in S 2 N D ST 1-12" SOLID SLV, RJ ' CONNECT TO PROP 12" GV (BY CITY FORCES) W I 1-12" 450 BEND, RJ e,v N 2-12" INSULATING SLV, RJ 1-TB I �.5145 CB 3002E p ::�E � ' I0 RIM 43.2 / `�.� \Go \ / I E 41.7 NI s \ / ' GP- —u - W = �G�= ' _ W - - - - .` \ \ STA L8+47, 17' LT IM 4 0 " I NE, 6 CONC T ti0 \\ 'y \ 1-12" CAP, RJ 1-2" TEMP BLOW -OFF / .0 I � 1-TB CR / CUT AND CAP, SEE00 `Q r DEMOLITION PLANS FOR CUT o c I I I AND CAP LOCATION AT MILL AVE S AND HOUSER W S = FINAL CONFIGURATION FINAL CONFIGURATION FINAL CONFIGURATION CONNECTION DETAIL CONNECTION DETAIL CONNECTION DETAIL K L M SCALE: NTS A-25 SCALE: NTS W-25 SCALE: NTS W-26 W-394920 NOTICE SEO RECORD RENTON DOWNTOWN SHEET /Z 1 IF THIS BAR DOES NOT MEASURE 1" DESIGNED BAW DRAWINGS SEE NOTE ON murraysmiIMPROVEMENTS ® UTILITY WATER CONNECTION DETAILS — 3 W-4` DRAWN TTT THEN NOTDRAWING SCALE IS COVER SHEET PROJECT 92 Of 121 CHECKED 1 10/26/2022 JJM RECORD DRAWING NO. DATE BY REVISION PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: JANUARY 2021 M N ►i U N U) J N z O V) w w w w J w Q N N O M N O N O M I 0) 3 1 O w 0 Q Ln N N 1 06 a� N U) i Q U i N aJ (0 L d d 0 0 re I Ln N N i 00 U .o a �I W no 1-6" PLUG, RJ W/2" TAP & 2" BLOW -OFF 1-TEMP TB \ ,o~ VERTICAL CROSS (MJxFL) FOR POLYPIGGING �- 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG �\ 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW -OFF 1-TEMP TB —6"DI W- S3RDST �- —12"DI W CUT IN (BY CITY FORC 5 L IV U 5 1 1-12" TEE, FLGxFLG 3-12" GV, FLGxRJ " �■FO, U' 2-12"SOLID SLV, RI xxxxxxxxxxxx��E`2 DI 12 DI X 1-TB IlLIVIUVL VI-%LVL POTENTIAL TESTING CONFIGURATION CONNECT TO EXIST 6" (BY CITY FORCES) 1-12"x6" RDCR, RJxRJ 1-6" 450 BEND, RJxRJ 1-6" SOLID SLV, RJ 1-TB 1-12"x8" RDCR 2-8" 450 VERT BEND • TT STA A 11 +48, 10' LT S2NDST �--12" DI W�14 12" DI W NFO FINAL CONFIGURATION CONNECTION DETAIL SCALE: NTS 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY REVISION 1-4" PLUG, RJ W/2" TAI 1-TEMP TB NOTICE JAM RECORD 0 Yz 1 DESIGNED DRAWINGS BAW DRAWN murra SMi mt IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE \, POTENTIAL TESTING CONFIGURATION EA S3RDST �- —12"DI W STA RO+94 2-6" 45° VERT BI-I.v, CONNECTION DETAIL SCALE : NTS • RENTON DOWNTOWN � + UTILITY � IMPROVEMENTS • PROJECT 1 011 MI T h 1 PI CI A It 1!"177 CONNECT TO EXIST-+uW (BY CITY FORCES) 1-4" SOLID SLV, RJ FINAL CONFIGURATION WATER CONNECTION DETAILS - 4 PROJECT NO.: 18-2251 1 SCALE: AS SHOWN DATE: JANUARY 2021 W-394921 SHEET W-43 93 of 121 0) C'7 N U a) V) J rl N z O LJJ LL LL LJJ J LJJ a N N O M N O N O I 0) 3 I O w 0 I I a I Ln N N I Ln a) a) Q N a) Ln ra a a 0 0 a� Ln N N i 00 U a) L a �I w TOTAL SF OF BEARING SURFACE NEEDED FOR TEMPORARY THRUST RESTRAINT USING ECOLOGY BLOCKS TOTAL WEIGHT OF ECOLOGY BLOCKS (LBS) 31600 71200 101800 141400 181000 211600 z 4 1 - - - - - Lu , 6 5 2 - - - - "' 8 10 8 5 3 - - W 12 - 23 20 18 15 13 1. CONTRACTOR TO CONFIRM UNCONFINED COMPRESSIVE STRENGTH OF SOIL IS AT LEAST 500 PSF. 2. TEMPORARY THRUST RESTRAINT UTILIZING ECOLOGY BLOCKS BASED ON TOTAL SYSTEM PRESSURE AND WATER HAMMER PRESSURE OF NO GREATER THAN 120 PSI. THIS TABLE SHOULD NOT BE USED FOR NEW MAIN WITH TEST PRESSURES HIGHER THAN 120 PSI. 3. SHIMS AND/OR GROUT SHALL BE PLACED AS NECESSARY TO FILL VOIDS BETWEEN RESTRAINED JOINT CAP, ECOLOGY BLOCKS, AND UNDISTURBED SOIL. 1\ 110/26/20221 JJM I RECORD DRAWING NO. DATE BY NOTICE JAM 0 Y2 1 DESIGNED BAW DRAWN IF THIS BAR DOES NOT MEASURE 1" TTT THEN DRAWING IS CHECKED NOT TO SCALE NnTFc 1. BEARING SURFACE 2. TYPICAL ECOLOGY BLOCK (2x2x6) 3. TEMPORARY RESTRAINT JOINT CAP 4. EXISTING WATER MAIN TO REMAIN IN SERVICE 5. SHIMS TO BE PLACED BETWEEN CAP AND ECOLOGY BLOCK AS NEEDED 6. GROUT TO BE PLACED BETWEEN ECOLOGY BLOCK AND UNDISTURBED EARTH AS NEEDED TO PREVENT SLIDING OF THE ECOLOGY BLOC 7. TYPICAL TRENCH 8. PROPOSED WATER MAIN 9. THRUST BLOCK TO FOLLOW STD 330.2 10. 2" TAP AND TEMP WATER SERVICE RECORD DRAWINGS SEE NOTE ON murraVSMi mt COVER SHEET EA 0 TOP SECTION VIEW NOT TO SCALE i_ 18" _i 10 8" 2'-0" 1'-6" 1'-6" 1'-6" 2 10" 2'-6" 1'-6" 1'-6" 1'-6" 2 12" 2'-6" 2'-0" 1'-6" 1'-6" 4 16" 3'-0" 2'-6" 2'-0" 1'-6" 4 NOTES: ' 1. CONCRETE SHALL 3000 P.S.I. READY MIX POURED IN PLACE. 2- REINFORCED BARS SHALL BE DEFORMED BARS AND TIED TOGETHER. 3. FORMWORK AT FACE OF ANCHOR WALLS MUST BE REMOVED. BACKFILL AT FACE OF ANCHOR WALL MUST BE COMPACTED TO 95X MAX DRY DENSITY BASED ASTM D1557 PRIOR TO REINSTATING SERVICE OF THE WATER MAIN. E. IN, I MAXIMUMN. ELEVATION VIEW Y arr + PUBLIC WORKS CONCRETE DEADMAN BLOCK � ` DEPARTMENT RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT #4 REBAR AT 8" ON CENTER WITH 180' STANDARD HOOKS ® BOTH ENDS RECOMMENDED POLYPIGGING AND DISINFECTION PLAN START CONNECTION DETAIL END CONNECTION DETAIL rA W-40 rA W-1 rD W-40 rD �-3 rN"'� W-43 N ��3 rG W-41 rG W-16 D �W-40 D �-3 E W-41 rE W-19 rK**�� W-42 rK W-25 rL W-42 L W-26 rL W-42 L W-25 M W-42 M W-26 POLYPIG PLAN AND TEMPORARY THRUST BLOCKING PROJECT NO.: 18-2251 1 SCALE: AS SHOWN I DATE: JANUARY 2021 W-394922 SHEET W-44 94 of 121 REVISION N U Ln tn i N LU Y Q m 0 a Q Ln m 0 fM N O N N a 0) a U Q Ln N N i ul v U) i a i N N U) rB a a 0 c 0 61 c: Ln N N i 00 U L a �I w ■■ TU C�\IITr 1.Ir1 A r,�r,�� i.ir IYIII VI\LJIV IYI !ll\VVL PLAN ELEVATION ANODE INSTALLATION rl �pl PM-1ule ,IfillWA1: (17 #10 AWG STRANDED CO GRADE LEVEL TEST STATION 1-#8 AND 1-#12 AWG COPPER WIRE WITH BLUE TW INSULATION eTHERMITE WELD WIRE CONNECTION, TYPICAL EXISTING SPU WATER LINE: CRPL#1 66" STEEL CRPL#2 51.5" STEEL CRPL#3 6611 STEEL COPPER -COPPER SULFATE REF ELECTRODE, #14 AWG COPPER WIRE WITH YELLOW RHW INSULATION 1'-6" SQUARE CONCRETE SLAB, 6" THICK FINISH GRADE e-TERMINAL BOARD 1-#8 AND 1-#12 AWG COPPER WIRE WITH WHITE TW INSULATION CONNECTION TO SPU -WATER LINE TO BE MADE BY SPU ­--RENTON D.I. WATER LINE ZINC DRAIN ANODE #12 AWG COPPER WIRE WITH BLACK THHN INSULATION. PLACE ANODE BETWEEN PIPELINES TYPE FF — FLUSH MOUNTED TEST STATION eTHFRMITF WFI n WIRE #2 AWG JOINT BOND CABLE V-6" SQUARE CONCRETE SLAB, 6" THICK GRADE LEVEL TEST STATION COPPER -COPPER SULFATE REF ELECTRODE, #14 AWG COPPER WIRE WITH YELLOW RHW INSULATION. PLACE ADJACENT TO JOINT. FINISH GRADE TERMINAL BOARD e RENTON D.I. WATER LINE THERMITE WELD WIRE 8 CONNECTION, TYPICAL INSULATING JOINT e TYPE FI — FLUSH MOUNTED TEST STATION 8 THERMITE WELD CAP OR MASTIC MOLD TO FIT OVER THERMITE WELD & FOLLOWER RING MECHANICAL JOINT BOND CONNECTION #10 AWG JOINT BOND CABLE THERMITE WELD, TYP WITH THERMITE WELD CAP OF e8 MASTIC TAPE COATING NOTE: COAT ALL EXPOSED STEEL AND COPPER WITH PRIMER PRIOR TO APPLYING WELD CAP 1 2 30 04 0 0 0 0 5 6 TERMINAL FF TEST STATION FI TEST STATION 1 #12 BLUE, RENTON #12 BLUE, PROTECTED 2 #8 BLUE, RENTON #8 BLUE, PROTECTED 3 #12 WHITE, CRPL #12 BLACK, ISOLATED 4 #8 WHITE, CRPL #8 BLACK, ISOLATED 5 #14 YELLOW, REF #14 YELLOW, REF 6 #12 BLACK, DRAIN ANODE CONDUCTOR TERMINATIONS -A &.MV ^An I1ILI\IYIIIL TV - EXOTHERMIC WELD 68 CP1 HANDLE MOLD LID STARTING POWDEF METAL POWDER METAL DISC MOLD COPPER SLEEVE CABLE METAL SURFACE INDUCTOR 1�IR�II>)�I:Z�P►���1:7yT�3� CONSTRUCTION NOTES: JOINT BONDING ALL DUCT I LE I RON P I PE JO I NTS VALVES, TEES, AND OTHER METALL I C EQU I PMENT ASSOC I ATED W I TH THE NEW WATER L I NE SHALL BE MADE ELECTR I CALLY CONT I NUOUS W I TH I N 50' OF THE SPU CROSSINGS UNLESS OTHERWISE SPECIFIED ON THE PLANS. FORE I GN L I NE CROSS I NG (TYPE FE) TEST STATIONS I. INSTALL TEST STATIONS AT THE LOCAT I ONS SHOWN ON THE PROJECT DRAWINGS. 2. TEST LEAD INSULATION COLOR AND WIRE SIZES SHALL BE AS DESCRIBED ON DRAWINGS. 3. 1 NSTALL A S I NGLE REFERENCE ELECTRODE BETWEEN EACH RENTON AND SPU PIPELINE CROSSING. THE ELECTRODE SHALL BE SPACED EQUIDISTANCE BETWEEN THE LINES. 4. 1 NSTALL A Z I NC DRA I N ANODE AT EACH RENTON AND SPU PIPELINE CROSSING. MAINTAIN A MINIMUM DISTANCE OF 4' BETWEEN THE ANODE AND REFERENCE ELECTRODE. ISOLATION (TYPE FI) TEST STATIONS I. INSTALL TEST STATIONS AT THE LOCAT I ONS SHOWN ON THE PROJECT DRAWINGS. 2. TEST LEAD INSULATION COLOR AND WIRE SIZES SHALL BE AS DESCRIBED ON DRAWINGS. 3. 1 NSTALL A S I NGLE REFERENCE ELECTRODE ADJACENT TO THE INSULATION FITTING. ANODE INSTALLATION . H I GH POTENTIAL MAGNESIUM ANODES ARE TO BE INSTALLED ON THE ELECTRICALLY CONTINUOUS SECTIONS OF THE NEW RENTON D. 1. P I PEL I NE. 2. ALTERNATE ANODE PLACEMENT ON OPPOSITE SIDES OF PIPE. 3. LOCATE ANODES 2' M I N I MUM FROM OTHER UNPROTECTED PIPES. 4. INSTALL ONE ANODE ON EACH LENGTH OF P I PE, SPAC I NG BETWEEN ANODES NOT TO EXCEED 20. J STEPS: #2 AWG INSULATED 1. CLEAN AND FILE PIPE TO BRIGHT STRANDED COPPER WIRE METAL. 2. STRIP INSULATION FROM WIRE SUFFICIENT TO CLEAR WELD MOLD, INSTALL COPPER SLEEVE AS PROTECTED PIPE UNPROTECTED PIPE 8 THERMITE WELD WIRE e REQUIRED. CONNECTION, TYP DRESSER STYLE 39 OR ROMAC STYLE IC 3. HOLD MOLD FIRMLY WITH OPENING 501 INSULATED NYLON SLEEVE COUPLING AWAY FROM OPERATOR, IGNITE FOR D.I. PIPE POWDER. NOTES: 4. REMOVE SLAG FROM CONNECTION, TEST WELD WITH SHARP HAMMER 1. ALL BONDING AND TEST LEAD CONNECTIONS BLOW. SHALL BE COMPLETED USING THE THERMITE WELD PROCESS. 5 POSED METALS AS INSULATING FLEXIBLE COUPLING (5 RCOVER 1 EQUIRED PUSH —ON AND FLANGED JOINT BOND NOTICE Jim RECORD DESIGNED 0 Yz 1 DRAWINGS BAW DRAWN m h IF THIS BAR DOES SEE NOTE ON murraysmirt NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET 1 10/26/2022 JJM RECORD DRAWING NOT TO SCALE NO. DATE BY REVISION i EXOTHERMIC WELD PROCEDURE RENTON DOWNTOWN • UTILITY '9 IMPROVEMENTS PROJECT CATHODIC PROTECTION - 1 PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE W-394923 SHEET January 2021 95 of 121