Loading...
HomeMy WebLinkAboutR-408205IN S. W. 114 OF S. W. 114 OF SECTION 04, T. 23 N., R. 05 E. W. M. CITY OF RENTON, STATE OF WASHINGTON JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2'x2' 14 GAUGE WIRE. OR EQUIVALENT. IF STANDARD STRENGTH FABRIC USED FILTER FABRIC --��__-_--_-----I-1__� - I W MAX. - I I I I 1 [' I.1 N J POST SPACING MAY BE INCREASED 4.4- MIN TRENCH TO 8' IF WIRE BACKING IS USED I I L BACKFILL TRENCH WITH NATIVE SOIL - OR 3!4' TO 1-112' WASHED GRAVEL 2-a4' WOOD POSTS, STEEL FENCE POSTS. OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY DE USED DOWNSLOPE OF ALL DISTURBED AREAS 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1 THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ADS (ASTM D4751) 30-100 SIEVE SIZE (O.GD-0.15mm) FOR SILT FILM SO-100 SIEVE SIZE (0 30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SECT MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) UL IRAVIOLET RESISTANCE (ASTM 04355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE, WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED. THE SLOPE SHALL NOT BE STEEPER THAN 2H:IV 2,4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4-X4- TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM B INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5 FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE. THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3 IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4 SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH. 3.5 IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN. IT SHALL BE REPLACED. UNEESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 214.00 PUBLIC WORKS SILT FENCE y 9/28/2018 1 1- DEPARTMENT GAZ .. .. ...,... DATE 3 0 J E U 1� e W I W s Know what's below. Call before you dig. il- :45 M R=25'MIN INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS EXISSL�G POPO 4'-8' QUARRY SPALLS GEOTEXTI-E - 12' MIN. THICKNESS CONSTRUCTION ENTRANCE NOTES: 1. DRIVEWAYS SHALL BE PAVED T EDGE OF THE RIGHT-OFWAV THRIGHT-OF-WA PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE \ ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 100' MIN 15' M' N. PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION S17E AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. 1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE STABILIZED SURF ACES SHALL BE OF SUFFICIENT LENGTIIMIIDIH TO PROVIDE VEHICLE ACCESSWARKING. BASED ON LOT SIZEICONFIGURATION 2. DESIGN AND INSTALLATION SPECIFICATIONS PA A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVENI CDR PUNCTURE STRENGTH (ASTM D6241) 495 LBS MIN. ADS (ASTM D4751) 12D45 (U.S. STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE. CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE PH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3, HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IV AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS 1 T I H I I CARRIED PAVEMENT. If THE HOG FUEL IS NOT PREVENTIN.. SEDIMENT FROM BEIN., TRACKED ONTO PAVEMENT OR F THE HOG FUEL S BE NG C R ED ONTO A EMENT. 2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE 2.5 WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAO AND REDUCE THE NEED FOR MAINTENANCE 3. MAINTENANCE STANDARDS 1. QUARRY SPALLS HALL BE ADD IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3. U ., S ADDED E T P T 3.2 IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OV THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH IF WASHING IS USED. IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK. AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 3.3 ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS. A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAU AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEH'CLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S). FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING 15 NUT TO SCALE (NIS) STD. PLAN - 215.10 ,• DEPARTMENT PUBLIC WORKS STABILIZED CONSTRUCTION ENTRANCE APPGVED 9/28/2018 1 v,l, <w:.., u.: r•„• . DATE nco mp as s ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division L--, 407 Swiftwater Blvd. • Cle Eluin, WA 98922 • Phone: (509) 674-7433 NO. :45 At J MAX. RAINAGE GRATE TRIM (;RA IL IRAML.- _ C_ OVERFLOW BYPASS 1 ' BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS ry`' FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.) Ail OVERFLOW BYPASS(TYP.) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: I. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2 INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA 161UST NOT BE LARGER THAN ONE ACRE 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGO SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6 THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8.01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216.30 • PUBLIC WORKS APPR LD '+It DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 DATE ROOTS 1 - AI One sign per 50 feet, (minimumof 2 signs) TREE PROTECTION FENCE DETAIL. I I I t t I I I I I j6 Ft. Temporary _ I Chain Link Fence SURVEYED: SCALE VERTICAL: NAVD 1988 SDM 1 " = 20 HORIZONTAL: NAD 1983/1991 DESIGNED. NEM DRAWN., TLK ONE INCH DATU M AS-BUILTS KMR 1051221231 KMR CHECKED: AT FULL SCALE NEM IF NOT ONE INCH REVISION BY DATE APPR I APPROVED: NEM SCALE ACCORDINGLY Pcx)TS NO TRESSPASSING PROTECTED TREES :45 At 0 Cl T Y OF RENTON Planning/Building/Public Works Dept. CRAM 12' DEPTH 2" - 4' ROCK 24' MIN. SETTLING DEPTH v Yi"M7 ' 35'-5' (., ` J; 1.5' MIN SEDIMENT STORAGE NOTES: 1. MAY BE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM 12" OVERFLOW DEPTH OUTFLOW CHANNEL IF r CONSTRUCTED BY I n EXCAVATION 12"DEPTH 314'-1112' WASHED GRAVEL FILTER FABRIC FENCING i UNLESS OTHERWISL NOTE O, DRAWING IS NOT 70 SCALF (NTS) STD. PLAN - 211.00 •®, PUBLIC WORKS APPR tED �It DEPARTMENT SEDIMENT TRAP GAZ g/2g/2plg DATE AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITION: AS OF 05122123 (DATE SIGNED) BY: KEVIN M. REESE - --� �- 05/22/23 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR :45 00 O (O U NIP z 0 0 R-408205 CC) IN COMPLIANCE WITH CITY OF RENTON STANDARDS � O J 28 HUNDRED UNIT L 0 T SUBDIVISION TESC DETAILS Q) W DATE: 1211312021 F'IELDBOOK' N/A PAGE: NIA T DRAWING N0: 1666.3 y oo SHEET., 5 OF., 12 N