Loading...
HomeMy WebLinkAboutR-408209IN S. W. 114 OF S. W. 114 OF SECTION 04, T. 23 N., R. 05 E. W. M. CITY OF RENTON, STATE OF WASHINGTON 0 d- 3 J N I t , 2', 4-, 6-, 12', OR 24- ONE N3 BAR HOOP FOR W HEIGHT INCRLMENT (SPACED EQUALLY). SEE NOTE i RECTANGULAR ADJUSTMENT SECTION t,Oi�AS EE 46 s 49. A 43 BAR EACH CORNER kFN2. �QrF� 43 BAR EACH SIDE #3 BAR EACH WAY a PRECAST BASE SECTION 03 BAR HOOP N3 BAR EACH CORNER 18' MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION • PUBLIC WORKS ViIl DEPARTMENT PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12' CONCRETE ALL METAL PIPE 15' CPSSP', 12' STD. SPEC. 9.05.20 SOLID WALL PVC, STD- SPEC. "5.12(1) 15' PROFILE WALL PVC, STD. SPEC. 9-05.12(2) t5' ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1, AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9 0.50(9)). OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH 111E MINIMUM REQUIRED REBAR SHOWN IN 1HE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BF PLACED IN THE KNOCKOUTS, AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20'. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF2-LAINI1,4LIMT075'MAXINILIM PROVIDEAI.5' h11NIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL TIDE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRACE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. S. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT 1 HL TOP OF TIDE PRECAST BASE SECTION- 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9.20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9.043. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS. RINGS. RISERS. AND FRAMES 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURERS DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. It ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLE 110,14. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 200.00 nvvR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 DATE SEE NOTE 2 s PERFORATED PIPE TO BE LEVEL CLEANOUT PER STD. PLAN 226.00 2' MIN. L 6'DIA MIN PERFORATEDPVC 314' TO 1-112' WASHED DRAIN ROCK PIPE PER ASIM DI785 HOUSE PLAN YARD DRAIN OR CATCH BASIN WITH SOLID LID ROOF DOWNSPOUT WITH OVERFLOW WIVE AND SPLASH BLOCK FLEXIBLE GASKETED CAP PER ASTM D5926 6' PAIN. r 6' MIN HOUSE W DIA MIN. SCH40 PVC 12' PIPE PER ASTM 01785 FINE MESH SCREEN, SS304 10x10 OR SIMILAR COMPACTED BACKFILL :45 Al -- .. - --T- ;--��- 6* MIN �: L PIPE ' 6' MIN. NONWOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9.33.2(1) TABLE 3 12' MIN 12' MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY I� 24 LAIN RESTRICTIVE LAYER SECTION A NOTES: 1. 15' MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES. BASEMENTS, OR ELEVATIONS BELOW THE OVERFLOW POINT. 2. REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100' MAX WHEN LOCATED IN COARSE SANDS OR COBBLES, INFILTRATION TRENCHES MUST BE AT LEAST 20' IN LENGTH PER 1.000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 30' IN LENGTH PER 1.000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLI SS OTIR RW 61 NOTI D. DRAWING 15 NOT TO SCA1E (NTS) STD. PLAN - 225.20 • PUBLIC WORKS SINGLE FAMILY ROOF DOWNSPOUT I� DEPARTMENT INFILTRATION TRENCH GAZ 9/28/2018 DATE Encompass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. • Cle Eluln, WA 98922 • Phone: (509) 674-7433 :45 CLEAN SURFACE AND BOTTOM AREA PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION I I I I I I I I SEE NOTE 4 NOTES: 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH. OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED. AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSOOTIAPWA STANDARD SPECIFICATION 7.05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3, A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y: BOND 5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. G. MORTAR SHALL MEET THE REQUIREMENTS OF WSOOTIAPWA STANDARD SPECIFICATION 9.04.3. 7. PICK I LIF TING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9.20.3(2). B. MORTAR SHAH BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9. FRAME SRALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE UI SUFFICIENT LENGTH W ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) A&MSTD. PLAN - 202.00 • PUBLIC WORKS Pao DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 I 9 VR .�+. w„L..T,..L...,,.. DATE MIN I MIN I MIN I MIN I 55PECIAL NOTE: IN THE EVENT TRANSVERSE PATCHES EXIST J ' WITHIN THE AFFECTED STREET, THE LENGTH III. OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH 11H11J 10 FEET OF THE EDGE OF THE PATCH REQUIRED i FOR THE NEW CROSSING AND ANY SUBSEQUENT PATCH EDGE WITHIN 10 FEET OF THE EDGE OF THE SECOND PATCH AND SO ON UP TO A TOTAL OF 300 FEET, I I I FACE OF CUTTER OR ILI', EDGE OF PAVEMENT ! I I TRAFFIC FLOW I i I I 2" HMA - I _ I 1 - CENTER LINE OR LANE LINE 2" TO B HAIA I I I 6.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 6.5' MIN. -- 1' 1' 1' 1' DEPTH OF Ex1511NC PAVt 1AE1JT -.- MIFJ I PAIN � VARIES -"{ PAIN I MIN 2" SAWCUT AND REMOVE OR PLANE, SEAT WITH 2" - 6- MIN. HMA (SEE NOTE 2) AR-4000W (EACH SIDE) \6" CRUSHED SURFACING TOP COURSE (CSTC) 2" HMA (9-039(3)) PER WSOOT STANDARD SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROCTOR. SAWCUT AFTER BACKFILL (EACH SIDE) CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03 19), GRAVEL BORROW! (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIOI45 OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOIECH REPORT, COMPACTED TO 95% MODIFIED PROCTOR. WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED IMPROVEMENT (SEE WSOOT STANDARD SPECIFICATION 2-09 4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF PIPE ZONE BEDDING. MATERIAL- SEE STANDARD NEEDED, SHALL MEET THE REQUIREMENTS OF WSOOT PLAN 110.1. STANDARD SPECIFICATION 7-08.3(1)8 TRENCH WIDTH FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR STD. PLAN - 110 PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID I'I'h 1:11 „ DEPARTMENT PAVEMENT WITH OVERLAY f0 1 AS-BUILTS NO. REVISION :45 25 1/4- BOLT -DOWN HOLE (TYP.) - 518'. 11 NC, SEE DETAIL AND NOTE 2 TOP RECESSED ALLEN HEAD CAP SCREW 518'-11 NCx2' GH IE FRA4E SECTION BOLT -DOWN DETAIL SEE NOTE 2 24 1/4' I SECTION A ISOMETRIC VIEW SEE DETAIL 718, \ \ 1!8' / \ J/4' / 11/4' ` NOTES: I 1 THIS FRAME IS DESIGNED TO ACCOMMODATE 20' • 24' GRATES OR COVERS. 1 4 1/2- SEE STANDARD PLANS 204.10. 204.20. 204.30. AND 204,40. -�-I 1518, I 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRANiES, GRATES, AND _1L I / COVERS. UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE 1 5/8' FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8'-11 NC It 2' ALLEN HEAD CAP SCREW BY 314' / BEING TAPPED. OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. \ 2 112' 3 REFER TO STANDARD SPECIFICATION 9-05. 15(2) FOR ADDITIONAL \ DETAIL _ REQUIREMENTS. UNLESS OTIIERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.00 • PUBLIC WORKS RECTANGULAR FRAME D 9/28/2018 1 'tl® DEPARTMENT GAZ DALE. VARIES: 4.5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL r - DEPTH OF FXISTING PAVEMENT 2" - 6" HMA -- � - � --- (SEE NOTE 2) 1' 1' EDGE OF PAVEMENT, EDGE OF CURB & GUTTER, OR MIN. MIN. CENTER OF LA14C MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD 2" SAWCUT AND REMOVE SPECIFCATIONS, COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR- 4000W CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF 0 95% MODIFIED PROCTOR. PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSDOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE OF IMPROVEMENT INSTALLED, EXCEPT: WSDOT STANDARD SPECIFICATION 7-08.3(1)B • FOR STORM AND WATER PIPE, PER STD PLAN 220.0 F-� FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH 0 FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A #4 SIEVE AND LESS THAN 5% PASSING A #200 SIEVE NOTES: 1. WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2. PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND T14ICKNESS SHALL BF HMA CL J" PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS - HMA CL J" PG 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4". S. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHAH. BE PLANED OR REMOVED AND OVERLAID WITH HMA. 4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT, 5. IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS. TYPICAL LONGITUDINAL PATCH STD. PLAN - 110.1 • PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR I' ` I J 1 DEPARTMENT RIGID PAVEMENT WITH OVERLAY 1p f t I SURVEYED: SDM DESIGNED: NEM DRAWN: TLK KMR 05122123 KMR CHECKED: NEM BY DATE APPR APPROVED: NEM SCALE 1" = 20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: MVD 1988 HORIZONTAL: NAD 1983/1991 DATU M AS BOLT -DOWN SLOT, I I/2' SEE DETAIL AND NOTE 1 \ 3/4' I�F- 1 1I1J' -'�tll I 518' TI BOLT -DOWN SLOT DETAIL LETTERING ISOMETRIC 24" 7 OR 8 EQUAL SPACES 1 DIRECTION OF FLOW 1 5/8' MAX SEE NOTE 1 1' 3' 20- I NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES GRATES AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 518%11 INC x 2' ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2, REFER TO STANDARD SPECIFICATION 9-05. 15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME OF TAILS. SEE STANDARD PLAN 204.00 UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.20 •• PUBLIC WORKS Pao fft RECTANGULAR VANED GRATE GAZ 9/28/2018 V,1` DEPARTMENT n,n< DAIE CITY OF RENTON Planning/Building/Public Works Dept. AS -BUILT DRAWINGS PLAN THESE AS -BUILT DRAWINGS AND THE INFORMATION SHOWN ACCURATELY REFLECT EXISTING FIELD CONDITIONS AS OF 05/22/23 (DATE SIGNED) BY: KEVIN M. REESE 05/22/23 PROFESSIONAL ENGINEER OR DATE PROFESSIONAL LAND SURVEYOR :45 IN I z 0 0 R-408209 m IN COMPLIANCE WITH CITY OF RENTON STANDARDS � O J 28 HUNDRED UNIT L 0 T SUBDIVISION DETAILS Q) a1TE.• 1211312021 2) OOK N/A ACE.,FIELD P' PAGE: NIA T DRAWING N0: 1666.3 y oo SHEET., 9 OF., 12 N