Loading...
HomeMy WebLinkAboutR-408214z _0 U) r) m U) 0 J z D ID LLI ry ID z _ oo N U w Ld J Ll HYDROZONE NO. VALVE SIZE III I G.04 GPM (LAWN, PROPOSED LAWN ARE, HYDROZONE NO. VALVE SIZE I" 18.95 GPM (BED) HYDROZONE NO. VALVE SIZE I" 9.05 GPM (LAWN) EXISTING LANDSCAP EXISTING STREE TREE: EXISTING 51DEWAU HYDKOZONE NO. G VALVE SIZE I'' 22.46 GPM (LAWN) HYDROZONE NO.7 VALVE SIZE 111 23.83 GPM (BED) EXISTING RAI GARDE THIS IRRIGATION PLAN IS SCHEMATIC IN NATURE. FINAL PIPE LAYOUT TO BE DETERMINED IN THE FIELD. LOCATE ALL VALVES IN SHRUB BEDS IF POSSIBLE. VALVE SIZE I" 12.7 GPM (BED) Lane & Associates Landscape Architecture 13802 26TH AVENUE N.W. TULALIP, WA. 98271 (425) 885-2319 AD�% STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT BRUCE CAMERON LANE CERTIFICATE No. 375 S.W. 1 /4 OF S.W. 1 /4 OF SECTION 04, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON POINT OF CONNECTION SEE DETAIL / SHEET L-3 EXISTING WATER SERVICE 3/411 HYDROZONE NO. I VALVE SIZE I'' 8.84 GPM (BED) HYDROZONE NO. 2 VALVE SIZE I" 15.89 GPM (BED) CONTROLLER PROPERTY LINE HYDROZONE NO. I I VALVE SIZE I" 13.0 GPM (BED) HYDROZONE NO. 10 VALVE SIZE I'' I O. G8 GPM (LAWN) LATERAL LINE SPRAY HEAD LOCATION SEE IRRIGATION SCHEDULE PROPOSED SIDEWALK LOCATION MAIN LINE 12" FOR LEGIBILITY, SOME LINES ARE SHOWN IN SIDEWALKS OR OFF SITE, THESE ARE TO BE PLACED IN THE NEAREST APPROPRIATE BED (TYP) 'ER COORDINATE WITH GENERAL CONTRACTOR 5YM130L IRRIGATION MANUFACTURER/MODEL NO. SCHEDULE GPM RADIU5 P51 REMARKS RAINBIRD NOZZLES 15 STRIP SERIES 0 1 5E5T O.G I 4'x 15' 30 4" POP-UP (LAWN) 1 555T 1 .2 1 4'x3O' 30 G" POP-UP (BEDS) 1800 SERIES SPRAY HEADS 5 SERIES MPR 5Q 0.10 5' 30 4" POP-UP (LAWN) 5H 0.20 5' 30 G" POP-UP (BEDS) O 5F 0.41 5' 30 1800 SERIES SPRAY HEAD5 10 SERIES MPR ® I OQ 0.30 10' 30 4" POP-UP (LAWN) ® I OH 0.70 10' 30 G" POP-UP (BEDS) ® 1 OF 1.58 10' 30 1800 SERIES SPRAY HEADS 8 SERIES MPR E� 8Q 0.2G 8' 30 4" POP-UP (LAWN) 8H 0.52 8' 30 G" POP-UP (BEDS) 1800 SERIES SPRAY HEADS FOC POINT OF CONNECTION WITH FEBCO MODEL 850 1 1/2" DOUBLE CHECK A55EMBLY SEE SCHEMATIC DETAIL 5HEET LA-5 © HUNTER XC HYBRID CONTROLLER BATTER POWERED NOTE: PROVIDE'RAIN SENSOR', AUTOMATIC RAIN SHUTOFF DEVICE HUNTER PGV SERIES VALVES WITH DC LATCHING 50LENOIDE5 FOR BATTER POWERED CONTROLLERS ALL VALVES SHALL BE 1 .0" 51ZE MINIMUM LATERALS - PVC CLA55 200, SIZE A5 INDICATED ON CHART. MIN. 1 2" COVER - - - - - - MAINLINE - 1 1/4" PVC SCHEDULE 40 MINIMUM 1 8" COVER IRRIGATION SLEEVE, 4" PVC 5CHEDULE 40 MIN. 18" COVER PER DETAIL SHEET L-3 PROVIDE SLEEVES AT ALL DRIVEWAY AND 51DEWALK CROSSINGS SIZING FOP, PVC FIFF O-B GpM _V4" 9-16 CTM -1" 11-24 CTM -1Y" 25-32 6FM -1Y2" 33-50 6PM -2'' IRRIGATION NOTES 1. GENERAL CONTRACTOR TO PROVIDE: A. NOTIFICATION FOR THE INSTALLATION OF 5LEEVING. NOTICE TO IRRIGATION CONTRACTOR SHALL BE A MINIMUM OF 48 HOURS PRIOR TO INSTALLATION. B. ALL NECESSARY FIELD LAYOUTS TO VERIFY EXACT LOCATION OF ALL REQUIRED SLEEVES. C. IRRIGATION MAINLINE SLEEVES SHALL BE NO MORE THAN 24 INCHE5 NOR LE55 THAN 18 INCHES FROM TOP OF FINISH GRADE. D. ANY CHANGE5 AND/OR ADJUSTMENTS IN SLEEVES, ONCE INSTALLED, SHALL BE DONE AT THE EXPENSE OF THE GENERAL CONTRACTOR. E. INSTALLATION OF 110 VOLT ELECTRICAL SERVICES FROM ELECTRICAL 50URCE TO AUTOMATIC CONTROLLER, INCLUDING WIRE HOOK-UP INTO MOUNTED CONTROLLER (IRRIGATION CONTRACTOR WILL MOUNT CONTROLLER PER DE51GN AND COORDINATE WITH GENERAL CONTRACTOR). F. VARIFY WELL CAPACITY TO PROVIDE MINIMUM OF 22 GPM AT 45 PSI, OTHR W15E PROVIDE MINIMUM, A 3/4" IRRIGATION METER SERVICE FOR EACH TRACT. G. PROVIDE GALVANIZED STANDARD THREADED STUB -OUT WITH THREADED CAPON D15CHAKGF 51DE OF METER. STUB -OUT TO BE INSTALLED APPROXIMATELY 18 INCHES BELOW FIN15HED H. REMOVE ALL A5PHALT EXTENDING GREATER THAN 4 INCHES BEYOND BACK OF EXTRUDED CURBING, TO ALLOW FOR IRRIGATION HEAD PLACEMENT. 2. ALL WORK PER LOCAL CODE. INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 3. PRIOR TO START OF CONSTRUCTION VERIFY MINIMUM 50 GPM AT GO P51 AT STUB -OUT LOCATION, VERIFY ALL DIMENSIONS AND CONDITIONS, NOTIFY LAND5CAPE ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING CON5TRUCTION. 4. 5LEEVING 15 REQUIRED FOR ALL IRRIGATION AND CONTROL WIRE UNDER ALL PAVEMENTS, WALLS, ETC. CONTRACTOR 15 RESPONSIBLE FOR VERIFICATION OF 51ZE OF ALL 5LEEVING REQUIRED FOR COMPLETE INSTALLATION OF WORK. 5. ALL SLEEVES SHALL BE 2X THE DIAMETER OF INSERT PIPES UNLE55 OTHERWISE NOTED. BURY 18" AND PROJECT 15" INTO PLANTINGS. G. MAINLINE SHOWN RUNNING PARALLEL TO PAVING EDGE SHALL BE INSTALLED IN ADJACENT PLANTING AREAS AND NOT UNDER PAVEMENT. INSTALL ALL VALVES IN SHRUB AREAS. 7. PLAN 15 DIAGRAMMATIC. ADJUST LINE LOCATIONS A5 NECESSARY. HEADS TO BE PLACED ACCORDING TO PLAN. 8. PLACE ALL POP-UP HEADS 2 INCHES FROM ALL CURBS AND SIDEWALKS. SHRUB POP-UP HEADS TO BE SET MINIMUM 112 INCH ABOVE FIN15H GRADE (AFTER MULCH). PLACE LAWN POP-UP HEADS FLUSH WITH GRADE AND G INCHES FROM BUILDING5 (TO ALLOW FOR MOW STRIP). 9. PRESSURE TEST ALL 5Y5EM JOINTS, CONNECTIONS, COUPLING5, VALVES, AND ALL OTHER JUNCTION POINTS SHALL BE LEFT EXP05ED UNTIL COMPLETION AND ACCEPTANCE BY LAND5CAPE ARCHITECT. 10. PROVIDE OWNER WITH "A5-BUILT" DRAWINGS AND OPERATORS MANUAL UPON COMPLETION. SURVEYED: DESIGNED: BCL DRAWN: BCL 1. Revised per revised engineers site plan rec.11-14-19 BCL 11-18-191 FCHECKED: BCL NO. REVISION BY DATE APPR APPROVEBCL SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON Planning/Building/Public Works Dept. R-408214 A-NNNNNNN p APPROVED FOR CONSTRUCTION U) ISSIONS i PLANNING DIVISION BY: 19APPROVED 12/09/2019 jding BY: BY: BY: Ij m U) DATE: ~ DATE: 0 J DATE: z DATE: 28 HUNDRED UNIT LOT SUBDIVISION IRRIGATION PLAN DATE: 3/28/19 W FIELDBOOK: PAGE: z DRAWING NO: 44-2016 M= ` 0 N SHEET: L-2 OF: 3