Loading...
HomeMy WebLinkAboutPre-Con Meeting Notes 12_21DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Last Modified 1/30/2023 1 [Subject] 12/21/2023 CITY OF RENTON PRECONSTRUCTION MEETING WSADA Headquarters Addition, 12/21/2023 PROJECT PERSONNEL: Sam Morman, City Project Manager, 425-430-7383, SAMorman@Rentonwa.gov Thomas Main, Public Works Inspector, 206-999-1833, TMain@Rentonwa.gov Andrew Van Gordon, Planning Reviewer, 425-430-7286, AVanGordon@Rentonwa.gov Corey Thomas, Fire Inspector, 425-430-7024, CThomas@RentonRFA.org GENERAL: 1. Call the construction inspection line at 425-430-7203 24 hours before you start work. Notify Fire Dispatch, Renton Police Department, and King County Metro of project construction schedule. Fire Dispatch can be reached at 253-852-2121. The Renton Police Department can be reached at 425-430-7500. King County Metro can be reached at 206-477-1140. 2. CONSTRUCTION HOURS OUTSIDE OF RIGHT OF WAY: 7:00 AM to 8:00 PM Monday thru Friday and 9:00 AM to 8:00 PM on Saturday. Saturday work is by permission only. No work is allowed on Sunday. 3. CONSTRUCTION HOURS INSIDE OF RIGHT OF WAY: Follow approved traffic control plan. Saturday work is by permission only. No work is allowed on Sunday. 4. RIGHT OF WAY HAUL HOURS: 8:30 AM to 3:30 PM Monday thru Friday. Hauling on Saturday is by permission only. No hauling is allowed on Sunday. 5. INSPECTION HOURS: 7:00 AM to 3:30 PM Monday thru Friday. Contractor must call for City inspection before 3:00 PM on the previous day. Inspections outside of inspection hours must be requested. 6. To request work, hauling, and inspections outside of the hours listed above, contact the City no later than three working days prior to the requested activity. 7. After hours inspection fees (applies to inspections performed on Saturdays, Sundays, observed City of Renton holidays, and non‐holiday Monday‐Fridays outside the hours of 7:00am to 3:30pm). Current fees can be found on the City of Renton Fee Schedule. Any outstanding fees are to be paid by the specialized billing contact provided by the applicant. 8. Public Works Reimbursement (any work performed by City forces or under City contract on behalf of a permit applicant to repair damage to the City infrastructure caused by the permit applicant or contractor under its control, or any and all roadway or right‐of‐way cleanup efforts performed by City forces or under City contract that resulted from the work performed by the permit applicant or contractors under its control. Current fees can be found on the City of Renton Fee Last Modified 9/6/2017 2 WSADA Headquarters Addition, 12/21/2023 Schedule. Any outstanding fees are to be paid by the specialized billing contact provided by the applicant. 9. Contractors shall use only sets of drawings approved by the City for constructing utility and transportation improvements. Approved drawings are signed by the Project Manager and / or other city staff on each plan sheet. A set of approved drawings shall be kept on-site at all times. 10. RECORD DRAWINGS: It is the responsibility of the contractor and engineer to keep record drawings. All changes to the approved construction plans shall be shown on the record drawings. Record drawings are required to be submitted to the City. Record drawings submitted to the City shall be prepared, stamped, and signed by a Professional Land Surveyor or Professional Engineer licensed in the State of Washington. All plan sheets with utility and transportation improvements including those constructed per design, must be verified, stamped, and signed “As-Built”. Record drawings shall first be submitted to the City for review by the Public Works Inspector. Once the record drawings are approved by the Public Works Inspector, final electronic plans (PDF) shall be submitted for City permanent records. Recording of the final plat or short plat or issuance of final occupancy will not be completed until final record drawings are received. 11. If the materials shown on the approved plans differ from those shown in the City standard details, material submittals shall be made to the Project Manager for approval prior to installation. 12. MINOR FIELD CHANGES: Identify the proposed change(s) to the Public Works Inspector. If the Public Works Inspector determines that the change(s) is minor, the Public Works Inspector can approve the change(s) in the field. A summary of any minor changes approved by the Public Works Inspector shall be emailed to the Project Manager. If the Public Works Inspector determines that the change(s) needs further review and approval from other City staff, the contractor shall follow the directions in the Major Field Changes section below. 13. MAJOR FIELD CHANGES: Submit a digital plan clearly showing the proposed change(s) and justification via email to the Project Manager and Public Works Inspector. City staff will respond to the requested change within two business days. The Public Works Inspector cannot give approval for major construction changes in the field. 14. Trenches with City utilities shall be left open for inspection prior to backfill. 15. A spill kit shall be located on site and easily identifiable with signage. 16. PROJECT CLOSEOUT: The Civil Construction Permit Final Inspection and Construction Closeout Process Requirements document gives information of the requirements for construction closeout. The current version of the Final Inspection and Construction Closeout Process and Requirements document is included in this preconstruction meeting packet. All requirements of the codes and regulations for the construction permit closeout should be followed by the contractor and developer. 17. FINAL INSPECTION WALKTHROUGH: Contractor shall accompany the Site Inspector during the final walkthrough and provide any required traffic control. Last Modified 9/6/2017 3 WSADA Headquarters Addition, 12/21/2023 TRANSPORTATION: 1. TRAFFIC CONTROL PLAN: An approved traffic control plan in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) is required prior to any construction activity in the right of way. A traffic control plan should be submitted to the Project Manager for review at least five working days prior to proposed work in the right of way. The traffic control plan shall be submitted with the traffic control plan cover sheet found here: https://rentonwa.gov/city_hall/public_works/transportation_systems/operations/traffic/traffic _control_plans The traffic control plan shall address both roadway / vehicular and sidewalk / pedestrian traffic impacts. All traffic control plans will be required to submit no later than five (5) working days before the date of work. 2. STREET RESTORATION: Street restoration is required to conform to the City of Renton Trench Restoration and Street Overlay Requirements. A copy has been provided. All street repairs shall be complete and in place within 14 days, or as directed by the Public Works Inspector. 3. PAVING: Paving shall be done in accordance with WSDOT Standard Specifications Division 5. Weather limitations from this specification shall be followed. Reference Section 5-04.3(16) for HMA weather limitations. Pavement subgrade and rock surfaces shall be compacted to at least 95% of the maximum density. 4. TRENCHES: Trenches shall not be left overnight without approval of the Public Works Inspector. Trenches shall be backfilled, plated, or fenced. The proposed method of cover or protection shall be submitted to the Public Works Inspector for approval. Shoring plates and cold mix shall be available on site at all times. The Public Works Inspector will require cold mix for trench restoration in sidewalks or driveways. 5. City streets shall be kept clean at all times. Streets shall be swept in a timely manner. Truck washing and / or other measures as approved by the Public Works Inspector may be required for the duration of the project. 6. Construction traffic shall observe all traffic laws. All hauling shall consist of legal loads. 7. The right of way shall remain unobstructed when possible. No stockpiles are allowed in the right of way. All truck maneuvering and materials storage shall occur on-site. 8. NOISE VARIANCE: Projects that include construction between 10 pm and 7 am will require a noise variance if the project is located within 300 feet of a residential zone. • For work not exceeding 2 days, an Administrative noise variance is required. The process will take approximately five to six weeks for the review, public notification, decision, and end of appeal period prior to start of work. • For work exceeding 2 days, a Public Hearing will be required. The process will take approximately twelve weeks for the review, public notification, Public Hearing, Hearing Examiner decision, and end of appeal period prior to start of work. Last Modified 9/6/2017 4 WSADA Headquarters Addition, 12/21/2023 Please consider the noise variance time requirements when you plan and schedule the construction work. CITY UTILITIES SANITARY SEWER: 1. Pipe and materials shall be as indicated on the approved plans and standard notes. Any sewer pipe with less than four feet or greater than fifteen feet of cover shall be Ductile Iron, Class 50, or C900 pipe. 2. Pipe bedding shall be pea gravel or 5/8" minus crushed rock as approved by the Public Works Inspector. Bedding shall extend 1-foot above the pipe and 6-inches below the pipe. Backfill shall be compacted to at least 95% of maximum density. Compaction testing is required. 3. A Number 6 wire shall be wrapped around the stub and extended to the top with a 2” x 4” marker stenciled in white. 4. Contractor shall as-built the invert elevation of all side sewer stubs. If cleanouts are installed, the top and flowline shall be as-built and noted on the record drawings. 5. No shims or wedges shall be used on any utility structure. STORM/EROSION CONTROL: 1. Approved temporary erosion and sediment control (TESC) and stormwater pollution prevention and spill control (SWPPS) measures are to be installed as first order of business and maintained at all times per the approved drawings or at the direction of the Construction Stormwater Supervisor, or the project Certified Erosion and Sediment Control Lead (CESCL), and the Public Works Inspector. 2. The approved Construction Storm Pollution Prevention Plan (CSWPPP) shall be located on site at all times. 3. The Construction Stormwater Supervisor or CESCL shall review the site’s TESC and SWPPS measures at least weekly and within 24 hours of significant storms. Weekly reports outlining the status and condition of the erosion control plan, with any recommendations of change or revision to maintenance schedules or installation, are required to be submitted by the project Engineer of record or CECSL to the Project Manager and Public Works Inspector. Weekly reports shall include the project’s NPDES permit number (if applicable). 4. If dewatering for the site is required, all site construction stormwater discharge shall be less than 25 NTUs if discharged into Waters of the State. Any pipe conveyance system that eventually discharges to a body of water is construed as discharging into Water of the State. 5. If dewatering is proposed to the City sewer then a permit from the City and King County will be required. If dewatering is proposed to a sewer system belonging to another sewer district, contact that district for approval. Contractor is strongly encouraged to obtain all required sewer discharge permits in advance of any anticipated need to discharge to a sewer. Last Modified 9/6/2017 5 WSADA Headquarters Addition, 12/21/2023 6. Wet Season requirements found in Appendix D of the 2022 City of Renton Surface Water Design Manual (RSWDM) shall be adhered to for construction occurring between October 1st and April 30th. For construction occurring during the wet season, a Wet Weather fee, as defined in the City Fee Schedule, is applicable. 7. Dust control shall be implemented as directed by the Public Works Inspector. 8. Proper removal of all TESC measures is required prior to permit closeout unless otherwise approved by the Public Works Inspector or Project Manager. 9. Pipe and materials shall be as indicated on the approved plans and standard notes. 10. Contractor must notify the Project Manager and Public Works Inspector of any vertical conflict prior to proceeding with construction. Any proposed changes shall be submitted to the City as described in the Major Field Changes note. 11. Pipe bedding material shall be per WSDOT Standard Specifications 9-03.12(3) or as approved by the Public Works Inspector. Backfill shall be compacted to at least 95% of maximum density. Compaction testing is required. 12. Smooth interior wall corrugated polyethylene stormwater pipe, where permitted, shall use watertight couplings. It shall also be bedded in pea gravel as described in the City specifications. 13. Catch basin penetrations shall be grouted smoothly. 14. No shims or wedges shall be used on any utility structure. 15. Contractor will be responsible for TVing of the storm drain. Pressure tests on the storm drain shall be per City specifications. 16. The storm system shall be flushed and cleaned prior to final approval. This includes the downstream system for a minimum of two structures or 500 feet, whichever is greater. FIRE PREVENTION: 1. Access to the site shall be maintained at all times. Access must be able to support emergency equipment in all types of weather. 2. A separate permit from the Renton Fire Authority is required for the following items. These permits can be applied for at the 6th Floor of City Hall. a. Temporary storage, handling, or use of hazardous materials, as required by International Fire Code and City of Renton Ordinance. b. Temporary storage of fuel on site. c. Abandonment, removal, or installation of fuel storage tanks. d. Hot works on site (welding, soldering, cutting, brazing, etc.). PLANNING: Last Modified 9/6/2017 6 WSADA Headquarters Addition, 12/21/2023 1. TREE PROTECTION: a. Prior to development activities, the applicant shall erect and maintain six foot (6’) high chain link temporary construction fencing around the drip lines of all retained trees or at a distance surrounding the tree equal to one and one-quarter feet (1.25’) for every one inch (1”) of trunk caliper, whichever is greater, or along the perimeter of a tree protection tract. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees,” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. b. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies, or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. c. All areas within the required fencing shall be covered completely and evenly with a minimum of three inches (3”) of bark mulch prior to installation of the protective fencing. Exceptions may be approved if the mulch will adversely affect protected ground cover plants. d. The applicant shall retain a certified arborist or licensed landscape architect to ensure trees are protected from development activities and / or to prune branches and roots, fertilize, and water as appropriate for any trees and ground cover that are to be retained. e. Tree protection (fencing, etc.) must be retained throughout the project (site and building development). 2. Contact the Planning Reviewer directly for landscape inspection. 3. The contractor / applicant shall comply with all conditions of land use approval and SEPA Environmental Review. Conditions are listed on the first or second sheet of the approved plan. CONDITIONS TO ISSUANCE OF A CONSTRUCTION PERMIT: 1. Pay all system development, special assessment, and other outstanding permit fees. 2. Provide a surety device in the amount calculated by the City’s Bond Quantity Worksheet. The surety device can be a permit bond, assignment of funds, or irrevocable letter of credit. The Bond Quantity Worksheet and form for each time of surety device can be found in the Development Engineering Forms section of the City website located here: http://rentonwa.gov/business/default.aspx?id=42473. 3. Provide a copy of the utility / dirt contractor’s license number. 4. Provide a copy of the utility / dirt contractor’s City of Renton business license number.