Loading...
HomeMy WebLinkAboutR-425404A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON LO N 0 w I- z LU 75 w 0 0 z Q z 0 0 Q z m a 0 V�rQ^J STORM CATCH BASIN TYPE I RIM=23.19 IE=21.43, 4"PVC E IE=20.39, 6"PVC E IE=18.27, 8"PVC S STOP "RA YMOND A VE. S. W. " "S. W. GRADY WAY" CALCULATED INTERSECTION PER R-1 10.26'-\ STORM CATCH BASIN-4 TYPE I RIM=26.49 IE=23.04, 8"CMP S 1 o ' , o X212 _ A X�3,1 STORM CATCH BASIN SCRIBE #13 E 129562724 TYPE 1 1 ASPHALT N. 174302.58 STORM CATCH BASIN �Y WAY IM=26.60 x tiea� - 9- 30� STORM CATCH BASIN---,RIME25.46 FIRST AVE.qVE� ' IE=22.80, 8 CMP N tibia x 2 TYPE I ' IE=22.60, 12 CMP W T'1c CFI - -rXg • ;22„ IE=21.41, 8"CMP N �-' RIM=25.46 „ T , _ a a ' q�. IE=22.04, 8"CMP S IE=21.31, 12 CMP E ,„w 550.�5 5� X 7 .b x a a J p� -_- 3"� x IE=21.31, 12 CMP W S��°2� TON Ite x 2e. e � e ,�'� 6» SHING tie I a _ -X ,WASHINGTON A AUTO x a.. 2 " a �L� , 26 25 _24 1 eel z DEAL RS ASSN' y0� X�6A1 - �7i ^' 7 X,�6�,'� X`l6' x�6 - - '.A1/�= eA� Q tie a a e�� e�x PLAT) / FLl 7' (498.25 ib 25 PLAT) SEWER MANHOLE x 201 P5. RIM=24.41 1 ' �0 oa X ti5. x �- 25�° FO 4. $ a 2 'i So / 2 a �j9 ti�.2 . 5 24 8 C • ; A !yA.o A• 7 aAe ASPHALT CONCRETE WALKWAY 2 Xtin a �90 , ,,._ 6 o ° �' 95 I S ti2A^ 20� x I �I' / so 5k 2 \ - CD 24 HEDGE 2 0 2 o a �. 1 �I ? 1 CN x �1 w c . o TR 2 STORM DRAIN MANHOLE rn I GRAVEL SWALE/ 2 TYPE RIM=24.37 titi y5 - -� - STORMiPIP ' 2 IE=14.37, 18"CONC N x2�' CATCH BASIN 2�- 3 IE=14.52, 18 "CONC E r IE=14.57, 12"CONC S I I STORM PIPE 2 . cn 2�.71 I �� IE-14.82, 12 CONC SW o (n titi6b 1I 11 STRM 1 STORM DRAIN MANHOLE GRAVEL SWALE w' PO D \ TYPE II RIM=21.94 CONCRET I GRAVEL SWALE IE=16.34, 8"PVC E SWALE W HANNEL�AINI IE=15.29, 36"CMP S THROUGH IDEWALK 22.0 N, WATER VALVE i GAS VALVE 1 I - TBM MAG NAIL #12 3 N: 174099.19 Igo �11 2� x� E. 1295578.71 I X 21.54 1 1 ELEV.' 20.94 SANITARY SEWER MANHOLE I 21�6 1 PI �TEF� TYPE RIM=20.74 V) s / IE=772, 12"CONC N o ss ss s IE=8.07, 12"CONC E -tit SD < �e 1• IE=8.29, 10" CONIC S so Ln 21,07 �'- BLOCKED PIPE W I PIN � x 20' � - 1 tit � ,�0. X N x of / TO. a1 5 0„ a STORM CATCH BASIN I % tio81x 10. TYPE I SID �- S �x ti RIM=19 22 IE=14.84, 12"CONC N IE=15.18, 12 "PVC E IE=14.86, 12"CONC S STORM CATCH BASIN TYPE II RIM=17.95 IE=13.65, 12 "CONC N IE=14.53, 8"CONC E IE=13.80, 12 "CONC S IE=13.90, 12 "CONC W N ASPHALT _ CD. �" x tie11 -26� - a • ' (343 I i x k _NN _ �. N - CONCRETE a �e a, 25- \ l� y5. 2 I I I o � �o . - 2 5 tik' _ x by-N6 ASPHALT I o 50.0' ?�Ss9 ?6... 2 �A 6, a 1 x ti5 -25" X e �X2 \ I 2 �2 $ w �ixDO 7 -25 - �. �. � \ oel ti�oe 5 a a 1 \ 10 Tk. N �$q i _-25 7" MAPLE a I X tip. I ti�\a6 b! - .24 - X I I z i 1 u94.6 ��- g ,125�xS RI MAPLE '� a \ EAVE_ - I I I 6' 3 ID/ k 23.. 1 ?3� 23.1 EDGE �� 35 _ _ �X ��til 10. I I 2 GRAVEL CL 2 3.8 10e 24 5 T N 3340404730 1 I 1 •1 • 5 6 1 6 WSA A PROPERTY L�LC. I .• STORM CATCH BASIN I � �� MID STOR IPE TYPE 1 I , 1�� 11� �•� J� Ji� J 2 �a RIM=23.25 4 IE=17.92, 8"PVC N I ` r .�l',,1 T- FENCE ASCRIBE #14 IE=1780, 8 PVC S I i���� , �j .>,iI I t 2 2 IC'OI�S bri FATI0 , 4. 129, 639.43 _ _ ' T EXISTING C�' 7s 3.81 BUILDING I _F_-����TING BUILDING )�� ►� j: I ' - ' Ss to ss ' 1 STORM CATCH BASIN I I I JI I I s ss TYPE I STORM CATCH BASIN I I w ss s SA 3 RIM=21.58 1 TYPE I J I ss / RIAI ti9 2 CATCH BASIN IE=16.77, 8"PVC W RIM=20.81 I t1 / ss 3\ cTnRM CA(cd 5ASIN IE=17.13, 8"PVC S IE=16.62, 6"PVC N PLAT) J L / ss i SS I IE= IE=16.22, 8 PVC E (3 34A ss \ 3 RIM=20.58 I N��`2� 26� ss I CATCH BASIN IE=16.18, 8"PVC W 1 ' 6-AhHS �AWNN 36 "DOOR �,_-1 I � , _ ' SS____ ss I 2 IE=17.48, 6 PLASTIC S I ti' 3 __ so ��J CC i "'���'' I •� J �o•, s` - / ss 50.00' PLAT) 5' s � ss ,� 6„E 150.0 2 STORM PIPE do also �' i ss u o 1 SID /10 ?E c9 / SS STORM 1 GAS METER' ti :1' j sa 10 Lx SD 92 g;b a• ss / SD 1 I I 1. ' 20 O 19.82 �9 � 1556� So / / I 3 C- / I s X g ens i so / so I I 3 ��oss / so /' ASPHALT TYPEM CATCH BASIN I I I I RIM=18.99 TPN 3340404705 1 � ss � X / s° � 36"DOOR "FIRE I I sx �A INS 1 ' SPRINKLER ROOM" I IE=15.12, 12"CMP E so CATCH BASIN:ATCH BASIN I I IE=15.13, 12"CMP W SEE SITTS & HILL PROJECT NO. 17383 I I Irrt 1 RIM=20.75 I I TAN 3340404805 Q1 1 I IE=16.80, 8"PVC N e I IE=16.71, 8"PVC E I I I I I I �• STORM DRAIN MANHOLE o TYPEI I 1 I ) I j ' i RIM=21.47 I I I JJ IE=15.21, 36"CMP N TPN 3340404785 I I o ' (49 r I E=15.02, 12 "CONC S OIL WATER SEP. SOUTH I I I JJ '-BLOCK WALL STORM CATCH BASIN I I TYPE ll RIM=20.78 ti I IE=14.88, 12"CMP E • titi• IE=14.86, 12"CMP W 1 .. IE=14.51, 12"CONC N STORM CATCH BASIN I 1 j� TYPE 11 RIM=17 53 1 I jJ IE=1763, 24"CMP N S 12TH ST. IE=7.53, 8 CMP WI , I S.W. OIL WATER SEP. WEST +MAG NAIL #3002 I2� 26"0 R 4j�0 Al• 174nn9 R4 /FaF.1 TEMPORARY EROSION AND SEDIMENT CONTROL PLAN (PRIVATE) SCALE: 1"=20' 0 20. x 09 205bx N N j°6 1 1 "I0. 6 " x °z� O l NORTH HORIZONTAL SCALE: 1"=20' Call 811 20 0 20 40 • m two business days before you dig NO. REVISION SURVEYED: DESIGNED: DKM DRAWN: KLK CHECKED: DCD BY DATE AP P R APPROVED: DCD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU V + C TY OF RENTON Planning/Building/Public Works Dept LEGEND 0 AND EXISTING BUILDING PROPOSED BUILDING CATCH BASIN PROTECTION SAWCUT LINE DEMOLITION CLEARING LIMITS GENERAL NOTES 1. SEE APPLICABLE TEMPORARY EROSION AND SEDIMENT CONTROL NOTES ON C1.2 2. MATERIAL REMOVED FROM SITE TO BE DISPOSED OF AT AN APPROVED, OFF -SITE LOCATION 3. LAND OWNER TO COORDINATE WITH PURVEYOR OF UTILITIES BEFORE ANY DEMOLITION 4. LAND OWNER TO SHUT OFF AND REPAIR ANY UTILITIES DAMAGED ON -SITE THAT ARE NOT MARKED FOR REMOVAL 5. PROTECT ALL ON -SITE MONUMENTS OR FEATURES USED FOR SURVEY PURPOSES 6. PROTECT ALL TREES ON -SITE NOT MARKED FOR REMOVAL 7. PROTECT ALL IRRIGATION SYSTEM FEATURES 8. ALL SURFACES SHALL BE COMPOST AMENDED PER 200/C2.3 9. CONCRETE SIDEWALK PANELS TO BE REMOVED AT CLOSEST JOINT OUTSIDE OF DEMOLITION BOUNDARY 10. PROVIDE CATCH BASIN INLET PROTECTION AT CATCH BASINS NOT SHOWN ON PLANS THAT WOULD RECEIVE RUNOFF FROM THIS SITE. KEY NOTES PROTECT FEATURE AS NOTED 2� REMOVE FEATURE AS NOTED INSTALL CATCH BASIN PROTECTION PER STD PLAN 216.30/C1.3 SAWCUT CONCRETE FULL DEPTH TO SMOOTH, UNYIELDING EDGE 1fwf) C. sitts&hill CIVIL I STRUCTURAL I SURVEY 48449 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-0153 FlI'LL �' �¢ti'� http://www.sittshill.com/ RECORD D RAW I N G Project No.: 19682 Project Mgr.: DCD Proj. Engineer: DCD Proj. Drafter: KLK S E PTE M B E R 20, 2024 R-425404 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: WASHINGTON STATE AUTO 2022.11.30 DEALERS ASSOCIATION (WSADA) FIELDBOOK: PAGE: 621 SOUTHWEST GRADY WAY, RENTON, WA 98057 DRAWING NO: WSADA BUILDING ADDITION AND IMPROVEMENTS C1.0 TESC PLAN (PRIVATE) SHEET: OF: 4 26 N,