Loading...
HomeMy WebLinkAboutR-425412A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON LO N 0 W I- Cn I- z W 75 W O rr n 2 0 z a z O 0 a z 0 m a 0 a Cn ►� i w Q z J TS=24.35 BS=23.85__ TS=24.85 BS=24.35� TS=25.35 o _ BS=24.85 ;o I TS=25.31 BS=24.81 TS=24.81 BS=24.31 TS=24.31_ BS=23.81 C601, TYPE 1 N: 174,211.96 - E:1,295,624.85 RIM:23.93-____-- IE:20.09 8" E (IN) IE: 20.09 8" S (OUT) o o _ CFOq�.�l. i r 22 _ _ 7 a I a °a 7„ ti -" 7� � I w - - -26- a �5• _ -26_ - SWC001, 8" CO w 23.81 N:174,214.69 6" 5 0 E:1,295,633.37 5� e `RIM:23.30 _ -7 -25 �. �IE:21.43 4" E (IN) -IE: 20.39 6" E (IN) " M,IE.20.39 8" W (OUT) _ I „ MA 2J. -, 23 7- 23.82 - 24 23 8-1 91_F-8" CPEP @ 3.36% 23.83 11LF-8" CPEP @ 3.36% CB03, TYPE 1 I L F.F.=23.83 N:174,163.23 / E:1, 295, 636.19 5OLF-8" CPEP @ 3.36% RIM:22.66 IE:18.05 8" W (IN) 3 I,I IE:18.05 8" S (OUT) C602, TYPE 1 ; N:174,162.06 E:1,295,625.28 INIM:22.41 _ 2- 3 4 4 C605, TYPE 1 J :18.41 8" N (IN) i 1 IN: 174,155.78 LIE:18.41 8" E (OUT) I E:1,295,633.67 RIM:21.13 9LFII I8" CPEP @ 23.34% I 1 1 1 IE:17.36 6" S (IN) C606, TYPE 2-54" - I \ 2 IE:17.36 8" W (OUT) N:174,155.09 I 15LF-6" P @ 0.00% Lqd 11J RIM:22.47 3SD� IE:15.29 8" E (IN) �� 170SQFT 40LF- % aP� IE:15.29 36" S (OUT) I ' �.� � 20.63 SD � � � ss i SC,SD 3LF-36 CPEP @ 0.00% 6 4 W ss , sD 2 SD 24LF-60" ALUMINIZ D CMP@ 0.00% I ' 5 C1304, TYPE 1 so 3LF-36"JPEP @ 0.00% N:174,124.60 �s E:1,295,645.62 CB07, TYPE 2-54 I RIM: 20.75 N:174,125.48 � sD �' IE:16.71 8" N (IN) I E:1,295,626.67 s¢ IE:16.71 8" E (OUT) RIM:21.64 SD o� Q11 IE:15.29 36" N (IN) �� IE:15.29 12" S (OUT) I ��'� x TO, - U 113.1 05" 2oa1x Boa SD S I I 06" 0 2o5ax ti,6 I I I CV I � I I I �oAtix o� 06„ o I I GRADING AND STORM DRAINAGE PLAN (PRIVATE) SCALE: 1"=20' NORTH HORIZONTAL SCALE: 1"=20' Call 811 20 0 20 40 • ® two business days before you dig NO. REVISION I I \ - -24 - I I I � I I � I I J, � �1�J r 1'�1J�1 b11, ii�� , _ •�i� �� f �� I I � _ I t1 SURVEYED: DESIGNED:DKM DRAWN: KLK CHECKED: DCD BY DATE APPR APPROVED: DCD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY I I I -8. I J � VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF ,R RENTON Planning/Building/Public Works Dept LEGEND SD STORM DRAIN PIPE, INSTALL PER STD PLAN 220.00 AND 220.10/C3.3, AS APPROPRIATE ® TYPE 1 CATCH BASIN, INSTALL PER STD PLAN 200.00/C3.3 TYPE 2 CATCH BASIN, INSTALL PER STD PLAN 201.00/C3.3 25 MAJOR CONTOUR 23 MINOR CONTOUR TS TOP OF STAIR STEP BS BOTTOM OF STAIR STEP GENERAL NOTES 1. SEE APPLICABLE GRADING AND STORM DRAINAGE NOTES ON C3.2 2. SLOPES NOT TO EXCEED 3H:1V 3. TYPE 1 CATCH BASINS SHALL BE TOPPED WITH LOCKING BI-DIRECTIONAL VANED GRATES GRATES PER STD PLAN 204.00 AND 204.30/C3.4, UNLESS OTHERWISE NOTED 4. TYPE 2 CATCH BASINS SHALL BE TOPPED WITH LOCKING SOLID LIDS PER STD PLAN 204.40/C3.4, UNLESS OTHERWISE NOTED 5. CONTRACTOR TO FIELD -VERIFY LOCATION OF EXISTING UTILITIES 6. SEE STORM DRAINAGE SYSTEM PROFILES ON SHEET C3.5 7. STORM STRUCTURES SHALL BE INSTALLED PER STD PLAN 202.00/C3.3 8. CONTRACTOR TO CONNECT ROOF DRAIN AND FOOTING DRAIN TO CB05 WITH 4" PERFORATED PVC SDR35. DRAINS NOT SHOWN ON PLANS FOR THE SAKE OF CLARITY AND FLEXIBILITY OF LOCATION AND INVERT. CONNECTING PIPE MUST HAVE A MINIMUM OF 1' GROUND COVER AND A MINIMUM 1% SLOPE. CROWNS SHOULD MATCH AT C1305, IF POSSIBLE. IF CROWNS CANNOT MATCH AT C1305, THEN THE INVERT OF THE CONNECTING PIPE MUST REMAIN ABOVE THE INVERT ELEVATION OF PIPES CONNECTING AT C1305. 9. PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE, OR TO END OF PIPE IN THE EVENT IT DOES NOT TERMINATE IN A STRUCTURE. 10. BIOFILTRATION POND MUST HAVE A BOTTOM OF 169SF OR GREATER, PER ORIGINAL DESIGN. KEY NOTES INSTALL BEEHIVE GRATE PER STD PLAN 262.40/C3.4 MODIFY EXISTING CONTROL STRUCTURE PER STD PLAN 237.00/C3.4 B� INSTALL 60" 0 STORAGE TANK PER STD PLAN 235.00/C3.4 4� INSTALL SOLID LOCKING LID PER STD PLAN 204.10/C3.4 SALVAGE AND REUSE EXISTING STRUCTURE, IF POSSIBLE. OTHERWISE, INSTALL NEW STRUCTURE AS APPROPRIATE RESTORE EXISTING BIOFILTRATION POND PER DETAIL 300/C3.3 7� ADJUST EXISTING WATER VALVE MANHOLE COVER ELEVATION TO FINISH GRADE SIDEWALK CUT AND PLATE PER DETAIL 301 /C3.3 CONCRETE STAIRS PER DETAIL 340/C3.5 10 PARALLEL RAMP PER WSDOT STD PLAN F-40.12-03/C3.5 11 SINGLE DIRECTION RAMP PER WSDOT F-40.16-03/C3.5 sitts&hill ` V A 46449 ,<<j `O. CIVIL I STRUCTURAL I SURVEY 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-0153 http://www.sittshill.com/ Project No.: 19682 Project Mgr.: REISSUED F 0 R OCTO B E R 30, PERMIT 2023 Proj. Engineer: DCD Proj. Drafter: R-425412 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY SAMorman 12/05/2023 JFarah 12/11/2023 DCD KLK DATE: WASHINGTON STATE AUTO 2022.11.30 DEALERS ASSOCIATION (WSADA) FIELDBOOK: PAGE: 621 SOUTHWEST GRADY WAY, RENTON, WA 98057 DRAWING NO: WSADA BUILDING ADDITION AND IMPROVEMENTS C3.0 GRADING AND STORM DRAINAGE PLAN (PRIVATE) SHEET: OF: 12 26 (0 N 0) T O M N u ME M N a J