Loading...
HomeMy WebLinkAboutR-425416A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 251/4" 29 114" BOLT -DOWN HOLE (TYP.) - 5/8 11 NC, SEE DETAIL AND NOTE 2 TOP RECESSED ALLEN HEAD CAP SCREW 5/8"- 11 NC x 2" GRATE FRAME -� � q All SECTION BOLT -DOWN DETAIL SEE NOTE 2 24 1/4"<> I SECTION A SEE DETAIL ISOMETRIC VIEW 7/8" 1/8" ' 11/4" 1 NOTES: 1 1. THIS FRAME IS DESIGNED TO ACCOMMODATE 20" x 24" GRATES OR COVERS, 4 112" SEE STANDARD PLANS 204.10, 204.20, 204.30, AND 204.40. I 1 518" 1 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND IDE TWO HOLES IN THE / FRAME THAT ARE VERTICALLY ALIGNED WITH COVERS, UNLESS OTHERWISE SPECIFIED. OTHE GRATE OR COVER SLOTS. 1 5/8 THE FRAME SHALL ACCEPT THE 618"-11 NC x 2" ALLEN HEAD CAP SCREW BY 3/4" / BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF \ / BOLT -DOWN HOLES VARIES BY MANUFACTURER. \ 2 1/2 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL \ DETAIL REQUIREMENTS. UNLESSOTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.00 PUBLIC WORKS ° DEPARTMENT RECTANGULAR FRAME GAZ 9/28/2018 I Punur wonz Aam�mnmror DATE DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 F MAX. - OPTIONAL PARALLEL TANK TERMINAL END / 36'MIN.� INLET PIPE ACCESS RISERS, SEE NOTE 4 (BACKUP SYSTEMS, �L SAME SIZE AS INLET PIPE, WHERE ALLOWED) I I J I� 12" MIN. DIA. I I 2' MIN. VV II II ACCESS RISERS PER FLOW _ A STD. PLAN 211.10 OUTLET PIPE 0 O INLET PIPE (FLOW THROUGH) CONTROL STRUCTURE WITH 36" MIN. CONNECTOR PIPE SOLID LOCKING LID PLAN TYPE 2 CATCH BASIN (CB) "FLOW -THROUGH" SYSTEM SHOWN SOLID. REQUIRED FOR FLOW THROUGH DESIGNS FOR "FLOW BACKUP" SYSTEM AND SYSTEM ONLY PER STD. PLAN 201.0 PARALLEL TANKS SHOWN DASHED FINISH GRADE 5D MAX. 1 00'MAX. 2"MIN. DIA. AIR VENT PIPE ACCESS RISERS, SEE WELDED TO TANK (REQUIRED STD. PLAN 235.10 IF NO ACCESS RISER ON TANK) 2' MAX. 6" MIN. ® 2' MIN. SEE NOTE 10 DETENTION TANK (TYPO (SIZE AS REQUIRED) 6" SEDIMENT STORAGE A-- FLOW 2' MIN. 2' MIN. 36" MIN. DIA. (TYP.) SEE NOTE 10 (TYP.) CONTROL STRUCTURE(FROP-T SECTION A SHOWN), MIN, 54" DIA. TYPE 2 CB PER STD. PLAN 237.00 NOTES: FLOW RESTRICTOR PER STD. PLAN 237.00 1. THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2. MINIMUM TANK DIAMETER IS 36 INCHES. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. ACCESS RISERS REQUIRED WITHIN 50 FEET FROM ANY LOCATION IN THE DETENTION TANK AND WITHIN 5 FEET OF EACH TERMINAL END. ANY LOCATION WITHIN THE DETENTION TANK SHALL HAVE A DIRECT LINE OF SIGHT FROM AN ACCESS POINT, UNOBSTRUCTED BY ANY RESTRICTIONS SUCH AS A WALL OR BAFFLE. 5. H-20 LIVE LOADS MUST BE ACCOMMODATED FOR TANKS LYING UNDER PARKING AREAS, ROADWAYS, AND ACCESS ROADS. 6. BEDDING OF THE PIPE SHALL BE IN ACCORDANCE WITH STD. PLAN 220.00. 7. PRIOR TO STARTUP, DETENTION TANK SHALL PASS LEAK TEST. 8. PIPE MATERIAL, JOINTS, AND PROTECTIVE TREATMENT FOR TANKS SHALL BE IN ACCORDANCE WITH SECTIONS 7-04 AND 9-05 OF THE WSDOT/APWA STANDARD SPECIFICATION. 9. ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES. 10. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 11. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) A10• STD. PLAN - 235.00 �PUBLIC WORKS AtRlMCLMdb : ,' DEPARTMENT TYPICAL DETENTION TANK artin Pastucha 8/13/202 ��1�3A♦LYD... DATE a z J U_ :45 An 1 8:4 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 24" 1 � 4 EQUAL SPACES -1 [- 4 EQUAL SPACES �{ 1 5/8" MAX. J SECTION A I I I I 10 BOLT -DOWN SLOT, SEE DETAIL AND i 3/4" ;OTE 1 I 1 1/4" I � I I I I BOLT -DOWN SLOT DETAIL L - SEE NOTE 1 _ J SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 518"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. USE ONLY IN SAGS ON VERTICAL CURVES. 4. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.30 PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL PR °' ,C,,� �I� DEPARTMENT VANED GRATE GAZ 9/28/2018 I P„blik-k:Aamh-1, DATE DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS REMOVABLE WATERTIGHT � I COUPLING 0 FLANGE 2" MIN. A ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 6" MIN. 2' MIN, 6" MAX. PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS 12" MIN. UNDER PAVEMENT ADDITIONAL LADDER RUNGS (INSETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER 1 �J 7 ANGLE AS / / NECESSARY SE0, ii7 j FRAME & SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 :45 AN 16" MAX. VERTICAL BAR GRATE FOR SECONDARY INLET 6" MIN. DESIGN WATER ELBOW RESTRICTOR, SURFACE SEE DETAIL AND NOTE 10 HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 12"(TYP.) 1.5 x D SEE NOTE 9 (TYP.) MIN. 2' MIN. T D ISOMETRIC i OUTLET PIPE, SEE INLET PIPE NOTES 1 & 5 2' MIN. SHEAR GATE WITH CONTROL ROD FOR INVERT AND (ROD BENT AS REQUIRED CLEELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER) FOR VERTICAL L 12" SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 2 12" MIN. WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 NOTES: SECTION A 1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. DocuSign Envelope ID: 361B3403-7EOA-476C-AD63-4329FFEOC108 TIERING SLT HCtE5 - 3P1_,AiE9 3VALLr ;PACED W APART ON ieIW QIA. B.C. SKID GROOVE PATTERN DIA. P"HOLE COVER BOTTOM VIEW (3L RLT SOC. (ALLEW.. HEAD) 51b--1I 11.5 53 RUDDER JIII 3r4- 2 1l2' ,^ $ EON BOLTING DETAIL. 4TYP.) COVER SEC IION VIEW IM-1 11118" 1m RIM, 26 172"DfA. 25 IA' DIA. 0A1SKE7 T OR00+4' . DETAIL 174' DIA. NEOPRENE CASKET if4" � � + 1P2" 5' 3ne w. 23 3AI' DIA, CL OPE14 27 UI EF DIA SKID GROOVE PATTERN DETAIL 34 1W DIA MOM; 1 ALLGOVER& SHALL BE LOCKING LID PER EJ No 3717C1 OR APPROVED EOIUAL 2. THIS GUYER SHALL ONLY BE USED FOR STRUCTURES WITHIN PRIVATE L!_'-'ELOP4IEHTS OUTSIDE OF PUSLIr RlGlirZF.wwr, JNLl SSOIHLRI%115E NC 11U, UNAWINC IS N�11 IL' SCAR IN ISI STD. PLAN -204.40 PUBLIC WORKS STORM ROUND FRAME AND COVER DEPARTMENT (PRIVATE) 21rtin Pastuch@V13fz020 P,141�FD79U4-48o DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 20" FLOW CONTROL STRUCTURE ORIFICE DIAMETER (IN) ELEVATION WELDED RESTRICTOR 0.90 13.29 ELBOW RESTRICTOR 0.50 17.29 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T-0" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESSOTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 237.00 •�• PUBLIC WORKS FLOW CONTROL STRUCTURE - �e�"edby: 7K DEPARTMENT RESTRICTOR TEE a3r�tiizn� Pastucha $/13/20 DATE LCall 811 two business days before you dig NO" REVISION 0 18 24" ' � - I I P 112 O BOLT -DOWN SLOT, SEE DETAIL AND 314" 2 1/2" DIA. HOLE NOTE 1 1 1/4" _ A' 0o I 5/8" O� z: DO�O�O�O ��0�0�00 BOLT -DOWN SLOT DETAIL I SEE NOTE 1 �3 TOP "1 ISOMETRIC 4 3/4" 1 1/2" 1 5/8 R39". SEE NOTE 2 SECTION B R26", SEE NOTE 2 5„ NOTES: 3 1/2" y 3/4" 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. 5/8" PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8`11 NC x 2" ALLEN 4" HEAD CAP SCREW BY BEING TAPPED, OR OTHER II' 3/4" DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 1/2" DIA. HANDLE 1 1/2" 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. SECTION C 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.10 PUBLIC WORKS .•�• RECTANGULAR SOLID METAL COVER [G?7��Z 9/28/2018 I �I� DEPARTMENT Public Workx A-M..., DATE SURVEYED: DESIGNED: DKM DRAWN: KLK CHECKED: DCD BY DATE AP P R APPROVED: DCD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU V 8:48 :45 AN DocuSign Envelope ID: A9707D3B-AOEF-441 F-8140-2CDB48E878CA CAST IRON BEEHIVE GRATE AND FRAME, SEE NOTE 1 - OPTIONAL 6" OR 8" STREAMBED COBBLES, PER WSDOT 9-03.11(2), SEE NOTE 2 CATCH BASIN ADJUSTMENT SECTION AS REQUIRED, DESIGNER TO SPECIFY ELEVATION FDESIGN PONDING ELEVATION SEE NOTE 3 �'I- -IIII� � III-I II VARIES, 5' MAX. -III-III- III -III -III " ° I Ip-I I1ll=1I I�-I 7-7T - UNDERDRAIN PIPE, IF REQUIRED, SEE NOTE 4 (TYP.) - c� III=III=1 I� I SEE STD. PLAN 262.10 U 6" MIN. IIIIIIIIIIIIIIIIIIIII CATCH BASIN TYPE 1 PER STD. PLAN 200.00 OR OTHER STORM DRAIN PIPE, STRUCTURE WITH APPROVAL DESIGNER TO SPECIFY 12" MIN. SUMP CONCRETEBASE ° a ° 6" MIN. J 6. MIN. GRAVEL BACKFILL FOR DRAINS, COMPACT PER WSDOT STD. SPEC. 9-03.12(4) NOTES: 1. FRAME AND GRATE SHALL BE LOCKING AND GRATE SHALL BE BOLTED TO FRAME. FRAME SHALL CONFORM TO WSDOT STANDARD PLAN B-30.10-03. GRATE TO BE DUCTILE IRON BEEHIVE GRATE FITTING 20'724" FRAME. OLYMPIC FOUNDRY PART SM60BH OR EQUAL. SEE STANDARD SPECIFICATIONS 9-05.15(2). 2. MINIMUM STREAMBED COBBLE DIAMETER SHALL BE LARGER THAN MAXIMUM GRATE OPENING. 3. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 4. WHEN CONNECTING TO A NEW PIPE USE A FLEXIBLE CONNECTOR KOR-NSEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. GENERAL NOTES: 1. PLANT SPACING WITHIN FACILITY TO ALLOW MAINTENANCE ACCESS TO STRUCTURE. 2. 12-INCH MIN. CLEARANCE WITHIN OVERFLOW STRUCTURE SHALL BE PROVIDED FOR MAINTENANCE ACCESS. 3. OVERFLOW PIPES MUST BE LOCATED AT AN ELEVATION HIGHER THAN THE STORM DRAIN HYDRAULIC GRADE LINE TO PREVENT BACKFLOW INTO THE BIORETENTION FACILITY. 4. OVERFLOW STRUCTURE SHALL BE LOCATED WITHIN 10 FEET OF ROAD EDGE FOR MAINTENANCE ACCESS, UNLESS APPROVED OTHERWISE. OVERFLOW STRUCTURE MAY BE LOCATED IN SIDE SLOPES. 5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 262.40 • PUBLIC WORKS BIORETENTION -OVERFLOW OUTLET [Tm5R9;`Em­dby- DEPARTMENT STRUCTURE Martin Pastucha 11/2/2 Puernnip�8448D... DATE C TY OF IR , RENTON Plan ning/Building/Public Works Dept 01 L1) C. O i O� OT Wi�Sk. 41- sitts&hill CIVIL I STRUCTURAL I SURVEY 46449 1 4815 CENTER STREET I TACOMA, WA. 98409 ��C15�0 PHONE: (253) 474-9449 I FAX: (253) 474-0153 () �:1L �`Q http://www.sittshill.com/ Project No.: 19682 Project Mgr.: DCD REISSUED F 0 R PERMIT Proj. Engineer: DCD Proj. Drafter: KLK OCTOBER 30, 2023 R-425416 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SAMorman 12/05/2023 DATE: WASHINGTON STATE AUTO 2022.11.30 DEALERS ASSOCIATION (WSADA) FIELDBOOK: PAGE: 621 SOUTHWEST GRADY WAY, RENTON, WA 98057 DRAWING NO: WSADA BUILDING ADDITION AND IMPROVEMENTS C3.4 GRADING AND STORM DRAINAGE DETAILS i SHEET: OF:^^ T O O N 1 ♦`J N N J