HomeMy WebLinkAboutW-425401A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
LEGEND
It It
LO LO
N N
N CV
0
I—
I—
z
Cw
G
w
O
rr
n
L
0
z
Q
z
O
I-
0
Q
z
m
a
0
Q
a
z
Ld
o ' '
o
_
° I
o
°
—W— �__ —
Q• A.
°°
— — � � 2 � / I
-25-10
I I
S7" MAPLE a I \ — -24 - I
" MAPLE '� a
S
TE . a 6 MAPLE 34 23� 231
25 ° 3.4 23.4 — ,24 _ I I I
°. I
1 I
I
6" MA E A „ j SSCO-01, 6 SSCO I I �1� ��it3�
E:1,295,624.08
ate', RIM: 22.96
24- IE:15.79 6" E (IN)
Jl
3 ^ . IE:15.79 6" W (OUT)
n I 3 =�z3.83
Q POINT OF CONNECTION
/ TO BUILDING I I
N:174,169.92
J
- \SS 23_ a . E:1,295,627.08
\ �. IE:15.85 6" W (OUT) :J
i° VERT. BEND 3 \ 3LF-6" PVC SDR35 @ 2.00% N I L / Ss
I
11
1 1 48LF-6 PVC SDR35 @ 2.00% sD J ss
0 3 '� I\ (SSCO-01 TO 45° VERT. BEND)
� ss
1 ' Ss
° nuI
ss
O BPS SS S I
ss SD I
La
GAS G a L.� / TV SS SD SS / SD /
�
SS LSD I I
o / Ss
SD
W.
n
SS so
/S� _7
I I SS / SD
I
�s� /sD
JN—
ISS V' SD
En o SS— SD SD
SD '7
Z1.0
/X�o. ,_ I
I ti1`j do I � I
�o81X �o 05„
I I I
SD S I I I
GRADING AND STORM DRAINAGE PLAN (PRIVATE)
SCALE: 1"=20'
I
I
0
1 AS -BUILT GAS LINE INFORMATION
HORIZONTAL SCALE: 1"=20' Call 811
20 0 20 40 • m two business days
NORTH before you dig N0. REVISION
S&H 01.03.241 DCD SURVEYED:
DESIGNED:
DKM
DRAWN:
KLK
CHECKED:
DCD
BY DATE AP P R APPROVED:
DCD
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
v v v v v v v v v
CONSTRUCTION
RECORD DRAWING
PROJECT WAS COMPLETED IN SUBSTANTIAL
CONFORMANCE WITH THE APPROVED
PLANS. ELEVATION DEVIATIONS, WHERE
APPLICABLE, ARE DENOTED WITH PLAN
CALLOUT UPDATES, AND A STRIKEOUT
THROUGH THE ORIGINAL ELEVATION.
UTILITY AS -BUILT INFORMATION OBTAINED
BY SITTS & HILL ENGINEERS, INC
PROPOSED FEATURES -
SS SANITARY SEWER PIPE
• SANITARY SEWER CLEANOUT
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C0.1.
2. SEE CITY OF RENTON STANDARD WASTEWATER NOTES, STD. PLAN 413/C4.2
3. SEE SANITARY SEWER SERVICE PROFILE ON SHEET C4.2
4. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
5. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
6. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
7. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
KEY NOTES
INSTALL SIDE SEWER FROM BUILDING CONNECTION TO PROPERTY LINE
PER STD PLAN 406.2/C4.2
1�f) C.
sitts&hill
� I
'4 ` CIVIL I STRUCTURAL I SURVEY
4644E 4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
RECORD D RAW I N G Project No.: 19682 Project Mgr.: DCD
Proj. Engineer: DCD Proj. Drafter: KLK
SEPTEMBER 20,2024
W-435401 S-425401
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DATE:
d C TY �� WASHINGTON STATE AUTO FIEp022.11.30
RENTON DEALERS ASSOCIATION (WSADA)
PAGE:
621 SOUTHWEST GRADY WAY, RENTON, WA 98057 DRAWING NO:
Planning/Building/Public Works Dept. WSADA BUILDING ADDITION AND IMPROVEMENTS C4.0
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PRIVATE) SHEET:
18 OF:
26
0)
T
O
O
N
W,
H
H