Loading...
HomeMy WebLinkAboutMFP23006325.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23006325 IVR Number: 23006325 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:12/22/2023Application Date:3342103248Parcel Number: 1308 N 30TH ST Permit Type:01/18/2024Issue Date:Franchise Permit Work Class:01/17/2025Expiration Date:Minor Utility Job Number: JB0001632675Franchise Type:Cable Description: This project proposes to riser down an existing utility pole on the south side of N 30th St then bore approximately 60' north, crossing N 30th St to target address. One new CATV vault will be placed on the north side of the street. All restoration will be done to or exceed all current city standards. Installation of (2) 2" HDPE conduits. Contractor shall pothole and verify all underground utilities prior to the start of construction. Contacts Name Address PhoneTypeBilling Leah Ihlenfeldt Cablecom LLC 1316 Bonneville Avenue Snohomish, WA 98290 B: (360) 670-4291ApplicantX Christie Walker Prince Telecom 13701 24th St E Building G, Building G Sumner, WA 98390 B: (253) 294-6548Applicant Jessamin Santos Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (206) 401-2188Contact CABLECOM LLC 20021 120th Ave NE, #101 BOTHELL, WA 98011 B: (360) 668-1300Contractor Business License Number: 52252Construction Contractor: CABLEL*971DP 7-ELEVEN 13155 NOEL RD STE 100 LB73 DALLAS , TX 75240 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date COMCAST Jessamin Santos 206-401-2188 WAConstruction_JointUse@comcast.com 360-670-4291 CABLEL*971DP Cablecom LLC - Leah Ihlenfeldt 52252 JB1632675 1308 N 30TH ST RENTON WA, THIS PROJUECT PROPOSES TO RISER DOWN AN EXISTING UTILITY POLE ON THE SOUTH SIDE OF N30TH ST AND THEN BORE APPROX 60' NORTH CROSSING N 30TH ST TO TARGET ADDRESS, ONE NEW CATV VAULT WILL BE PLACE ON NORTH SIDE OF THE STREET, INSTALL 2 HDPE CONDUITS 60 COMCAST - JB1344737 x 3/6/2023 MFP23006325 Scott Warlick 1/18/2024 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Cablecom LLC Leah Ihlenfeldt 360-670-4291 1316 Bonneville Ave Snohomish, WA 98290 1308 N 30TH ST RENTON WA This project proposes to riser down an existing utility pole on the south side of N 30th St then bore approximately 60'north, crossing N 30th St to target address. One new CATV vault will be placed on the north side of the street.All restoration will be done to or exceed all current citystandards. Installation of (2) 2" HDPE conduits.Contractor shall pothole and verify all underground utilities prior to the start of construction tbd upon permit inssuance COMCAST - JB0001632675 MFP23006325 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 1/18/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Jessamin Santos 12/22/23 TRAFFIC CONTROL - KEY MAPC-11SCALE: N.T.STHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OF1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON20ISSUE FOR PERMIT12/19/2023DOMSHEET TC-1MFP23006325 D/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WWWWWWSSWROADWORKAHEADW20-1XXSHOULDERWORKW21-522'22'N 30TH ST 25 MPHRURAL ROADS & URBAN ARTERIALSURBAN STREETS25 MPH OR LESS100' +/- (2)200' +/- (2)35 / 40 MPH25 / 30 MPH350' +/- (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.SIGN SPACING = X (1)RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25303540455055606570SHOULDERWIDTH(feet)10'8'4040406060909090USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'160200220170190240150190130170120150SignTraffic Cone or DelineatorLEGENDWork VehicleSPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEV.HOST VEHICLE WEIGHT! 22,000 OEV.MPH50/7035/4525/30TAPERTANGENT403020806040CHANNELIZATION DEVICESPACING (feet)1321 N 30th St,Renton, WA980561309 N 30th St,Renton, WA98056XX XXL/3L/3ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1SIDEWALKCLOSEDR9-9R9-11 (L)CROSS HERESIDEWALK CLOSEDAHEAD10' MIN. 10' MIN, SIDEWALK CLOSED AHEAD CROSS HERE R9-11 (R)NOTE:PLACE R9-11(R) SIGN ATNEAREST CROSSWALK1308 N 30th St,Renton, WA98056GENERAL NOTES:1.ALL "W" SERIES SIGNS SHALL BE 48" FLUORESCENT ORANGE, UNLESS OTHERWISE NOTED.2.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS.3.PEDESTRIAN SPOTTERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.4.NOTIFY TRANSIT AUTHORITY FIVE DAYS PRIOR TO STARTING WORK.5.ALL LANES SHOULD BE A MINIMUM OF 10' IN WIDTH AS MEASURED TO THE NEAR FACE OF THECHANNELIZING DEVICES.PARK AVE N 25 MPHPEDESTRIANS WILL BE ESCORTEDBY SPOTTERS THRU THECONSTRUCTION ZONESHOULDERWORKW21-5TRAFFIC CONTROLTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON20ISSUE FOR PERMIT12/19/2023DOMTC-12SCALE: N.T.S.MFP23006325 COVER-TITLETHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OF1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMScope of work to Target address 1308 N 30th St, Renton, WA·This project proposes to riser down an existing utility poleon the south side of N 30th St then bore approximately 60'north, crossing N 30th St to target address. One newCATV vault will be placed on the north side of the street.All restoration will be done to or exceed all current citystandards.·Installation of (2) 2" HDPE conduits.·Contractor shall pothole and verify all undergroundutilities prior to the start of construction.BUILDIn The City ROW·New Utility Pole(s): 1·Bore footage:~60'·New CATV Vault: 1VICINITY MAPSHEET INDEXSheet #1C-1Cover-Title2G-1General Notes3SW-1Storm Water Protection Plan4CD-1Construction Plans5D-1 Construction Details6SD-1Municipality DetailsSCALE: NONEContactC-1PROJECT ID: JB16326751CD-1Jessamin SantosComcastJessamin_Santos@cable.comcast.com206-401-2188MFP23006325 GENERAL NOTESTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMROADWAY CENTER LINEEXISTING COMCAST ROUTEEXISTING FENCELINEPROPOSED BORE ROUTEEXISTING WATER LINEEXISTING STORM DRAINEXISTING SANITARY SEWEREXISTING JOINT TRENCHEXISTING RECYCLED WATER LINEEXISTING TV SYSTEMEXISTING GAS SYSTEMEXISTING ELECTRICAL SYSTEMEXISTING TELEPHONE SYSTEMPROPERTY LINELINETYPESBORE PITWATER MANHOLEUNIDENTIFIED MANHOLEGAS METERWATER METERELECTRIC MANHOLESEWER CLEAN OUTSANITARY SEWER MANHOLESTORM DRAIN MANHOLECATCH BASINGAS/WATER VALVETREE/BUSHESGWEXISTING POLEEXISTING COMCAST PEDESTALNEW RISER ATTACHED TO POLEEXISTING IRRIGATION VAULTEXISTING COMCAST VAULTEXISTING UTILITY VAULT/PEDESTALSSCOECOWSDMONUMENTFIRE HYDRANTTRAFFIC SIGNAL COMBINATIONSTREET LIGHTTRANSFORMERNEW COMCAST LOW PROFILE NEW COMCAST PEDESTALNEW COMCAST VAULTPOWER SUPPLY W/ METERNEW COMCAST POWER SUPPLYSYMBOLSEXISTING WATEREXISTING TELEPHONEDRIVEWAYMAXIMUMD/WMAXW T RIGHT OF WAYEXISTING SANITARY SEWEREXISTING STORM DRAINPUBLIC UTILITY EASEMENTPROPERTY LINEMINIMUMFACE OF CURBEXISTINGCENTER LINECOMCASTL MINFOC (E) COMCAST CABBREVIATIONSPUEROWSS SDPL JTSSSDW+++TVTEGTVCATVNEW AERIAL STRAND/CABLE ROUTEOFFSETO/SBACK OF WALKBOWREMOVAL/REPAIRR/RNEW(N) G-12EDGE OF PAVEMENTEOPANCHOR SUPPORTPROOF & PULL ROUTE (NEW CABLE IN (E) CONDUITS)PROPOSED TRENCH ROUTERWOPGENERAL NOTES1.ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS.2.CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS(AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800)227-2600.3.CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIORTO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE,CONTRACTOR MUST VERIFY.4.CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OFCONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE.5.CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITEAT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY OF RENTONAND/OR LAW ENFORCEMENT UPON REQUEST.6.CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALLBE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTINGSTRIPING AND REMOVING UNNECESSARY "USA" MARKINGS.7.CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISEAPPROVED IN WRITING BY THE "CITY ENGINEER."8.CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITHTHE CITY OF RENTON AND STATE OF WASHINGTON STANDARD PLANS AND SPECIFICATIONS,AND CURRENT WASHINGTON DEPARTMENT OF TRANSPORTATION "MANUAL OF UNIFORMTRAFFIC CONTROL DEVICES" AND "WASHINGTON MODIFICATION (468-95 WAC)" FOR USE INPERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIREDFOR ALL LANE CLOSURES.9.CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITHREGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVINGJURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OFWASHINGTON UTILITIES AND TRANSPORTATION COMMISSION, THE STATE OF WASHINGTONDEPARTMENT OF LABOR AND INDUSTRIES, DIVISION OF OCCUPATIONAL SAFETY ANDHEALTH (DOSH), THE COUNTY OF KING, ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TOINSPECTION BY CITY ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST.10.CONTRACTOR SHALL "RED-LINE" ALL LAYOUTS, PLANS AND DETAILS, ON THE DAY OFCONSTRUCTION AND SUBMIT A COMPLETE SET OF "AS-BUILT" PLANS TO COMCAST UPONCOMPLETION OF THE PROJECT, AND TO CITY.11.CONTRACTOR SHALL NOTIFY RESIDENTS AFFECTED BY THE WORK IN LANDSCAPED AREA INADVANCE OF CONSTRUCTION.12.CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OFWORK COMMENCING.13.LANE CLOSURES ARE PROHIBITED BEFORE 8:30 AM AND AFTER 4:00 PM (3:00 PM OFFRIDAYS AND ON DAYS PRECEDING DESIGNATED LEGAL HOLIDAYS). NO LANE CLOSURES AREPERMITTED ON WEEKENDS AND HOLIDAYS.MFP23006325 CONCRETE WASHOUT450 MM(18") MIN.450 MM(18") MIN.25 MM (1") MIN.CONCRETEWASHOUTAREA NOTES:1.) FACE SIGN TOWARD NEAREST STREET OR ACCESS POINT.2.) CONCRETE WASHOUT SHALL BE LOCATED BEHIND THE CURB AND 15 M (50 FT.) MINIMUM FROM DRAINAGE INLETS OR WATERCOURSESBALE CONFIGURATIONTHIS SECTION REMOVED FORGRAPHICAL REPRESENTATIONONLY. STRAW BALE PERIMETERSHALL BE CONTINUOUS.SIGN600 MM(24") MIN.36 CM (14") MIN.3 M (10') MIN. TYP. OF 4 SIDES STRAW BALESAA900 MM(36") MIN.SECTION A - A60 MIL POLYETHYLENE50 X 50 MM (2" X2")STAKES OR #4 J-BARS2 PER BALE TYP.STRAW BALESINLET SEDIMENTCONTROL45° NOTES:1.) SEDIMENT TRAPPED UPSTREAM OF SEDIMENT CONTROL BMP SHALL BE REMOVED WEEKLY AND PRIOR TO A RAINFALL EVENT.2.) PLACE BMP'S TIGHTLY TOGETHER AT JOINTS TO PREVENT OR MINIMIZE SEEPAGE AT JOINTS.GRAVEL BAG(S) OR OTHER ACCEPTEDSEDIMENT CONTROL BMP. PLACE BAGSTIGHT AGAINST FACE OF CURB.BACK OF CURBFACE OF CURBLIP OF GUTTERDRAINAGE INLETWITH FILTER BAGPLAN VIEWSEE NOTE 2FLOWTHE MAXIMUM DRAINAGE AREA PER FILTER SHALL BE NO MORE THAN 0.8 HECTARES (2 ACRES).THE FILTER BAG SHALL BE MANUFACTURED FROM UV RESISTANT POLYPROPYLENE, NYLON, POLYESTER, OR ETHYLENE FABRIC WITH A MINIMUM TENSILE STRENGTH OF 50 LBS PER LINEAL FOOT, AN EQUIVALENT OPENING SIZE NOT GREATER THAN 20 SIEVE AND WITH A MINIMUM FLOW RATE OF 40 GALLONS/MINUTE/SQ FT.THE FILTER BAG MAY BE SUSPENDED FROM OR HELD IN PLACE BY THE EXISTING INLET GRATE (OR OTHER APPROVED METHOD), PROVIDING NO MODIFICATION OR DAMAGE SHALL BE DONE TO THE INLET GRATE OR FRAME. THE INLET GRATE SHALL NOT BE CAUSED TO REST MORE THAN 13MM (.5") ABOVE THE INLET FRAME (SEE DETAIL A).THE FILTER BAG MAY EXTEND TO THE BOTTOM OF THE INLET BOX PROVIDED THE OUTLET PIPE IS UNOBSTRUCTED.FLOWS SHALL NOT BE ALLOWED TO BYPASS THE BAG. THE BAG OR ITS FRAME SHALL CATCH FLOWS AT ALL SIDES OF THE INLET, EXCEPT AS SHOWN FOR FLOOD RELEASE.INLET FILTER BAGS SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL DURING THE WET SEASON AND MONTHLY DURING THE DRY SEASON. SEDIMENT AND DEBRIS SHALL BE REMOVED BEFORE ACCUMULATIONS HAVE REACHED ONE THIRD THE DEPTH OF THE BAG. BAGS SHALL BE REPAIRED OR REPLACED AS SOON AS DAMAGE OCCURS. EXISTING DROPINLET GRATEPLACEMENT AT TYPE A, C, D, & F DROP INLETSAND PARKING LOTSEXISTING DROPINLET FRAMEFILTER BAG(OPTIONAL)FRAME EXISTING DROPINLET GRATEBAG DEPTHMAXIMUMDETAIL AOUTLET PIPE1.3 CM (.5")MAXIMUMPLACEMENT AT TYPE B AND E DROP INLETSMINIMUMAT BACK(FLOODRELEASE)5 CM (2")18" MINIMUM EXISTING OPENBACK HOODCONTACTAT FRONTAND SIDESDETAIL AGRATE)MINIMUMBAG WIDTH(BACK OF5 CM (2")MINIMUMDAM CONTACT,ALL SIDESCURBSTORM DRAIN INLETFILTER BAGOUTLET PIPE65DETAIL A4.3.2.NOTES1.FILTER BAGFILTER BAGSTORM WATERPROTECTION PLANSTORM WATER PROTECTION PLANSW-13THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMMFP23006325 D/WD/WD/WD/WD/WD/WD/WD/WFOCSIDEWALKFOCSIDEWALKWWWW16" W16" W16" W16" W16" W16" W12" W12" W12" W12" W12" W12" W12" W12" SD12" SD12" SD12" SD12" SD12" SD12" SD12" SD12" SDWSS8" SS8" SS8" SS8" SS8" SS8" SSWGG1308 N 30th St,Renton, WA 98056N 30TH ST1305 N 30th St,Renton, WA 980561309 N 30th St,Renton, WA 980561302 N 30th St,Renton, WA 98056PARK AVE NRISER DOWN EXIST. UTILITY POLETRENCH IN SIDEWALK. ~30 SQ FT OF SIDEWALK RESTORATION12" WATER POTHOLE16" WATER POTHOLE8" SANITARY SEWER POTHOLEGAS POTHOLE12" STORM DRAIN POTHOLE3'X3' BORE PIT. PLACE NEWCATV VAULT UPON COMPLETIONCONTINUE BORE TO TARGET60' BORE ROUTESCALE: 1:20CONSTRUCTION PLANSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMCD-14MFP23006325 BORE PIT DETAILSCALE: N.T.S.(E) CURB & SIDEWALK3'x3' BORE/RECEIVING PITTRENCH RESTORATIONPER CITY OF RENTONSTANDARD DETAILS2-2" CONDUIT.BORE DEPTH SHALLBE BELOWSANITARYSEWER MAIN TOCLEAR ALL UTILITYA HIGH DENSITY REINFORCED CONCRETE BOX, WITH NON-SETTLING SHOULDERSPOSITIONED TO MAINTAIN GRADE AND FACILITATE BACKFILLING.APPROXIMATE DIMENSIONS SHOWN.B36 VAULT DETAILSCALE: N.T.S.CONSTRUCTION DETAILSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMD-15MFP23006325 MUNICIPALITY DETAILSTHIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALAPPROVED:DRAWN BY:DESIGN:DESCRIPTIONREVDATEAPPROVED:APPROVED:PROJ#: CONSTRUCTION TYPE: SYSTEM: NODE: SHEET: OFCALL TOLL FREE48 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERT1-800-227-2600IMPORTANT NOTICESection # 4216/4217 of the Government Code requires a Dig AlertIdentification Number to be issued before a "Permit to Excavate" will bevalid For your Dig Alert I.D.1308 N 30TH ST, RENTON, WAJB1632675-SMBBORERENTON60ISSUE FOR PERMIT12/19/2023DOMSD-16MFP23006325