No preview available
HomeMy WebLinkAboutMFP24000162.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24000162 IVR Number: 24000162 Permit Information Permit Name: P.178791 Address/Location:01/10/2024Application Date:7227801450Parcel Number: 1209 KIRKLAND AVE NE Permit Type:01/18/2024Issue Date:Franchise Permit Work Class:01/17/2025Expiration Date:Minor Utility Job Number: P.178791Franchise Type:Telephone Description: Access MH 424 on NE 12th St for splicing. Access HH 1202 on Kirkland Ave NE for splicing. Access MH 234 for splicing and placing fiber. Access MH 467, then trench approx 10' South to the developer provided conduit. At customer HH, splice and place 1000' of new fiber. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Merilyn Luong Lumen C: (206) 806-7160Applicant Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES 425-615-7121 P.178791 2/5/2024 2/8/2024 9am 4pm Northsky Communications Mike Smith 16701 SE McGillivray Blvd Vancouver, WA 98783 1209 Kirkland Ave NE, Renton 98506 Access MH 424, HH 1202, MH 234 for splicing and placing new fiber. At MH 467, trench approx 10' South to the developer provided conduit. At customer HH, splice and place 1000' of new fiber. MFP24000162 3:00pm Scott Warlick CED 1/18/2024 Merilyn Luong 1/10/2024 SHEET 1 SHEET 2-3 Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing Cover Sheet1:50P.178791 98056 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAY SRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DIST RICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)FREEWAY S & EXPRESSWAY S 55/70 MPH 1500 (OR ASPER MUTCD)MINIMUM TAPER LENGTH (L) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040 General Notes:1. All signs and spacing shall conform to The MUTCD and WAC.2. Priority passage through the w ork area for emergencyvehicles vehicles shall be provided at all times.3. Alert Metro Transit 5 days in advance4. Protective vehicle recommended may be a w ork vehicle.5. Devices should not encroach into adjacent lanes.6. All signs min. 36 x 36 B/O unless otherw ise specified.7. Channelization devices are 28" reflective cones8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or drivew ays.9. Traffic Control Supervisor required for ROW impacts. 10/29/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn MoralesAll Signs & Spacing to conform to the MUTCD Standards-reference W SDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Scope of Work: Manhole Access, Underground Installation, & TrenchingTraffic Control Plan: Cover Sheet MH TMHHH-1202MHMH-467C w w w.invarion.com MFP24000162 Scope of Work: Manhole AccessTraffic Control Plan: Right Lane Closure 1177 HARRINGTON AVE NE 2801 NE 12T H ST 2800 NE 12T H STMCKNIGHT MIDDLE SCHOOL NE 12T H ST REET 25MPH HARRINGTON AVE NE 25MPH LegendConeMHMH 424Sign StandSSpotterWork Area Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing 1 031:50P.178791 98056 Plan Scale1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAY SRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREET SALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)FREEWAY S & EXPRESSWAY S 55/70 MPH 1500 (OR ASPER MUTCD)MINIMUM TAPER LENGTH (L) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040 General Notes:1. All signs and spacing shall conform to The MUTCD and WAC.2. Priority passage through the work area for emergencyvehicles vehicles shall be provided at all times.3. Alert Metro Transit 5 days in advance4. Protective vehicle recommended may be a w ork vehicle.5. Devices should not encroach into adjacent lanes.6. All signs min. 36 x 36 B/O unless otherw ise specified.7. Channelization devices are 28" reflective cones8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or drivew ays.9. Traffic Control Supervisor required for ROW impacts. 10/29/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn MoralesAll Signs & Spacing to conform to the MUTCD Standards-reference W SDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. MH20'35'9'10'L SSPOTTER SHALL ASSIST PEDEST RIANSTHROUGH WORKZONE SAFELY. XXXROADWORKAHEADW20-1 W4-2RIGHT LANECLOSEDAHEADW20-5 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 w w w.invarion.comMFP24000162 NE 12T H ST 25MPH SIDEWALK CLOSEDAHEADCROSS HERER9-11(L) DETOURM4-9b DETOURM4-9bROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 MATCHLINE SHEET 3RIGHT LANECLOSEDAHEADW20-5 W4-2XX X S HARRINGT ON AV NE 25MPH JEFFERSON AV NE 25MPH LegendBore PitConeCCust HHSign StandSSpotterTTelephone Vault/HandholeTraffic LightWork Area Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing 2 031:50P.178791 98056 Scope of Work: Underground Installation & TrenchingTraffic Control Plan: Right Lane Closure Plan Scale1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAY SRURAL ROADSRURAL ROADS & URBAN ART ERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)FREEWAY S & EXPRESSWAY S 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840 BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 CHANNELIZING DEVICE SPACING (FEET )MPH TAPER TANGENT50/7035/4525/30 403020 806040 General Notes:1. All signs and spacing shall conform to The MUTCD and WAC.2. Priority passage through the w ork area for emergencyvehicles vehicles shall be provided at all times.3. Alert Metro Transit 5 days in advance4. Protective vehicle recommended may be a w ork vehicle.5. Devices should not encroach into adjacent lanes.6. All signs min. 36 x 36 B/O unless otherw ise specified.7. Channelization devices are 28" reflective cones8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.9. Traffic Control Supervisor required for ROW impacts. 10/29/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn MoralesAll Signs & Spacing to conform to the MUTCD Standards-reference W SDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. w w w.invarion.com MFP24000162 1171 KIRKLAND AV NE RENTON REGIONAL FIRE AUTHORIT Y1209 KIRKLAND AV NE RITE-AID3116 SUNSET BLVD NEKIRKLAND AV NE 25MPH TMHMH-234 HH-1202 MH MH-467C 10'10'10'10' 18'18' 9'12'30'STOPALL WAY 9'8'40' 9'30'45' SIDEWALK CLOSEDCROSS HERER9-11a(R) SIDEWALK CLOSEDCROSS HERER9-11a(R) DETOURM4-9b DETOURM4-9b DETOURM4-9bDETOURM4-9b SIDEWALK CLOSEDAHEADCROSS HERER9-11(L) SUNSET BLVD NE 35MPH SIDEWALK CLOSEDAHEADCROSS HERER9-11(L) SIDEWALKCLOSEDR9-9 DETOURM4-9bSIDEWALKCLOSEDR9-9 SIDEWALKCLOSEDR9-9SIDEWALKCLOSEDR9-9 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 NE 12T H ST 25MPH RIGHT LANECLOSEDAHEADW20-5W4-2 XXXLBLBMATCHLINE SHEET 2LegendBore PitConeCCust HHSign StandSSpotterTTelephone Vault/HandholeTraffic LightWork Area Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing 3 031:50P.178791 98056 Plan Scale1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAY SRURAL ROADSRURAL ROADS & URBAN ART ERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DIST RICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)FREEWAY S & EXPRESSWAY S 55/70 MPH 1500 (OR ASPER MUTCD)MINIMUM TAPER LENGTH (L) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730 CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040 General Notes:1. All signs and spacing shall conform to The MUTCD and WAC.2. Priority passage through the w ork area for emergencyvehicles vehicles shall be provided at all times.3. Alert Metro Transit 5 days in advance4. Protective vehicle recommended may be a w ork vehicle.5. Devices should not encroach into adjacent lanes.6. All signs min. 36 x 36 B/O unless otherw ise specified.7. Channelization devices are 28" reflective cones8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or drivew ays.9. Traffic Control Supervisor required for ROW impacts. 10/29/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn MoralesAll Signs & Spacing to conform to the MUTCD Standards-reference W SDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. COORDINAT E WIT H RENTON FIRETO ENSURE T HAT T HEY 'REABLE TO EXIT T HE DRIVEWAYIN AN EMERGENCY. Scope of Work: Underground Installation & TrenchingTraffic Control Plan: Right Lane Closure w w w.invarion.comMFP24000162 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.140406400000”NVICINITY MAPSL2832 NE SUNSET BLVDRENTON, WA 98056P.178791W26226RNTNWA0123N5E912/27/2341®CUSTOMER NAME: SOLERA MARKETLCON: N/APHONE #: N/AEMAIL: N/AWFMT #: N/AORDER #:  N/AARMOR OR DSR #: N/ASCOPE OF WORK:POF: @ MANHOLE 424, SPLICE THE COUNT LRE23 333-344, FROM THE EXISTING 216-UG FIBER [TUR2] TO THE EXISTING 24-UG FIBER[A3G4L] & THE COUNT WILL TERMINATE IN HANDHOLE 1202. @ HANDHOLE 1202, SPLICE THE COUNT FROM THE EXISTING 24-UGFIBER [A3G4L] TO THE EXISTING 48 UG-FIBER [A3G44] THEN TO NEW 24 FIBER & TRENCH APPROX 24' IN NEW CONDUIT TO 4'X4'BORE PIT 1. @ 4'X4' BORE PIT 1, BORE NEW 24 FIBER APPROX 40' IN NEW CONDUIT TO 4'X4' BORE PIT 2. @ 4'X4' BORE PIT 2, TRENCHNEW 24 FIBER APPROX 30' IN NEW CONDUIT TO MANHOLE 234. @ MANHOLE 234, SPLICE & PLACE THE COUNT FROM THE EXISTING48-UG FIBER TO A NEW 140' OF UG 24-FIBER & TERMINATE IN MANHOLE 467. @ MANHOLE 467, TRENCH APPROX 10' SOUTH TO THEDEVELOPER-PROVIDED CONDUIT & INTERSECT THE DUCT RUN FOR FIBER PLACEMENT TO SEVERAL MDUS. @ FIRST MDU FORFIBER PLACEMENT WILL BE TO SOLERA MARKET. SPLICE & PLACE 1000' OF NEW 24-UG FIBER WITH THE COUNT LRE23, 333-336THRU THE DEVELOPER PROVIDED CONDUIT TO THE MDU SOLERA MARKET & TERMINATE IN THE MDF ON THE P1 LEVEL.SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ROBIN POEPHONE NO: 253-458-6571EMAIL: robin.poe@lumen.comREVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION - V2 1 & 4 ADDITION OF BORE & TRENCH WITH PITS - UPDATE SOW, TOTALS, STATIONING & NOTES SL 10/28/24MFP24000162 TTTTTEEEEE CATV CATV CATV CATV CATV CATV CATV CATV GGGGG TS TS TS TS TS WWWWW S S S S S SD SD SD SD SD C/L C/L C/L C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W P/L P/L P/L P/L P/L P/L B/C B/C B/C B/C B/C B/C B/C B/C EOP EOP EOP EOP EOP TTTUSAMEEPWREE CATV CATV TVTV CATV CATV CATV CATV CATV CATV CATV CATV VTS C/L C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL2832 NE SUNSET BLVDRENTON, WA 98056P.178791W26226RNTNWA0123N5E912/27/2342®MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: KIM BURKSPHONE NO: 503-881-3393EMAIL: kimberleah.burks@lumen.comMFP24000162 NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. C/L C/L C/L C/L C/L C/L C/L C/L C/L EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R /W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W C/L C/L C/L EOP EOP EOP EOP T R/W 2908PARCEL#72278017761200PARCEL#87265000801170 & 1174PARCEL#72278016752801PARCEL#72278016801177PARCEL#72278013552613 & 2615PARCEL#7227801345PARCEL#7227801860PARCEL#872650TR-A2607 & 2609PARCEL#7227801340POF LMN MH 424 NE 12th STREETSIDEWALK25SPEEDLIMITNOTE:POF: @ MANHOLE 424, SPLICE THE COUNTLRE23 333-344, FROM THE EXISTING216-UG FIBER [TUR2] TO THE EXISTING24-UG FIBER [A3G4L] & THE COUNT WILLTERMINATE IN HANDHOLE 1202.SIDEWALKHARRINGTON AVE NE SIDEWALK SIDEWALK 29'28'31'31'28'31'14'14'5' 20'20' R/W R/W NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL2832 NE SUNSET BLVDRENTON, WA 98056P.178791W26226RNTNWA0123N5E912/27/2343RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: KIM BURKSPHONE NO: 503-881-3393EMAIL: kimberleah.burks@lumen.comMFP24000162 NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. C/L C/L C/L EOP EOP R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W EOP EOP C/L C/L EOP EOP EOP R/W R/W R/W R/W TT EOP EOP EOP EOP RENTON REGINALFIRE AUTHORITYSTATION 121209PARCEL#72278014502908PARCEL#7227801776975PARCEL#7227801405 R/W R/W R/W R/W 2832NE SUNSET BLVDPARCEL#722780123525SPEEDLIMIT25SPEEDLIMIT30SPEEDLIMIT25SPEEDLIMIT25SPEEDLIMIT2+34 LMN MH 467 0+94 LMN MH 234C2+44 CUST HH1171PARCEL#7227801406NE 12th STREETSIDEWALKSIDEWALKJEFFERSON AVE NESIDEWALKHARRINGTON PLACE NESIDEWALK KIRKLAND AVE NESIDEWALKSIDEWALKSIDEWALKSIDEWALK 24'27'26'26' 24'25' 20'24' R/W R/W R/W R/W R/W R/W 3' 3' 9'9'9'9' 18'18'16'16'35'25'17'17'70'40'3002PARCEL#7227800285T LMN HH 12029'24'NOTE:@ FIRST MDU FOR FIBER PLACEMENTWILL BE TO SOLERA MARKET. SPLICE &PLACE 1000' OF NEW 24-UG FIBER WITHTHE COUNT LRE23, 333-336 THRU THEDEVELOPER PROVIDED CONDUIT TO THEMDU SOLERA MARKET & TERMINATE INTHE MDF ON THE P1 LEVEL.NOTE:@ MANHOLE 467, TRENCH APPROX 10'SOUTH TO THE DEVELOPER-PROVIDEDCONDUIT & INTERSECT THE DUCT RUN FORFIBER PLACEMENT TO SEVERAL MDUS.NOTE:@ MANHOLE 234, SPLICE & PLACE THECOUNT FROM THE EXISTING 48-UGFIBER TO A NEW 140' OF UG 24-FIBER &TERMINATE IN MANHOLE 467.NOTE:@ HANDHOLE 1202, SPLICE THE COUNT FROM THEEXISTING 24-UG FIBER [A3G4L] TO THE EXISTING 48UG-FIBER [A3G44] THEN TO NEW 24 FIBER & TRENCHAPPROX 24' IN NEW CONDUIT TO 4'X4' BORE PIT 1.PLANTER GRADE SOFT, ASPHALT &CONCRETE SURFACE36" MIN TRENCH/BORE DETAIL 'A'TRENCH/BORE PLACEMENT OF 2" OR 4" CONDUIT - 36" MINN.T.S.6"MIN.2" OR 4" CONDUIT0+24 4'X4' BORE PIT 1IN DIRT0+64 4'X4' BORE PIT 2IN ASPHALTNOTE:@ 4'X4' BORE PIT 1, BORE NEW 24 FIBER APPROX40' IN NEW CONDUIT TO 4'X4' BORE PIT 2.NOTE:@ 4'X4' BORE PIT 2,TRENCH NEW 24FIBER APPROX 30' INNEW CONDUIT TOMANHOLE 234.NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS4RSL2832 NE SUNSET BLVDRENTON, WA 98056P.178791W26226RNTNWA0123N5E912/27/234SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: KIM BURKSPHONE NO: 503-881-3393EMAIL: kimberleah.burks@lumen.comMFP24000162RESTORATION PER CITY OF RENTON STANDARDS