GRADING LEGEND:
EXISTING CONTOUR ELEVATION
1250-
LINE
---GB - -
GRADE BREAK
EXISTING CATCH BASIN
DRAINAGE INLET
EXISTING PAVEMENT SLOPE
1.5%
PROPOSED PAVEMENT SLOPE
C - CONCRETE
D - DIRT
DI - DRAINAGE INLET
105.5TC
FF - FINISH FLOOR
10 05 OP
FL - FLOW LINE
P - PAVEMENT
TC - TOP OF CURB
. HEAVY
DUTY PORTLAND CEMENT CONCRETE.
° SEE SECTIONS ON THIS SHEET.
HEAVY
DUTY ASPHALT CONCRETE SEE
SECTIONS
ON THIS SHEET.
CONCRETE SIDEWALK. SEE DETAIL NO. 3
ON SHEET
C2.2.
DECORATIVE PAVEMENT
-------------
I I
I I
I I
I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
1
!■ 7 m m m m
MATCH LINE: SEE GRADING PLAN - SOUTH
GRADING NOTES:
OEXISTING BUILDING TO BE RENOVATED PER
BUILDING PLANS.
OPROPOSED GARDEN CENTER PER BUILDING
PLANS.
O3 CONSTRUCT CONCRETE PER STRUCTURAL PLANS.
OCONSTRUCT HEAVY DUTY CONCRETE PAVEMENT
PER DETAILS ON THIS SHEET.
OCONSTRUCT HEAVY DUTY ASPHALT CONCRETE
PAVEMENT PER DETAILS ON THIS SHEET.
OCONSTRUCT CONCRETE SIDEWALK PER RENTON
STANDARD DETAILS 102 AND F007 ON SHEET
C2.2.
O CONSTRUCT 6" CONCRETE CURB PER HOME
DEPOT DETAIL 26-C1 ON SHEET 2.2.
O CONSTRUCT 6" CONCRETE CURB AND GUTTER
PER RENTON STANDARD DETAIL 101 ON SHEET
C2.2.
OCONSTRUCT CURB RAMP PER WSDOT STANDARD
PLANS PER TYPE NOTED ON PLAN. SEE SHEET
2.2 FOR MORE DETAILS.
10 INSTALL CHARGING PEDESTALS FOR EQUIPMENT
RENTAL USE PER DETAIL ON SHEET C1.2. SEE
ELECTRICAL PLANS FOR MORE DETAILS.
11 SEE ROW PLANS FOR ROW IMPROVEMENTS.
12 CONSTRUCT LIGHT DUTY ASPHALT CONCRETE
PAVEMENT PER DETAILS ON THIS SHEET.
13 INSTALL DECORATIVE PAVEMENT PER:
• HEAVY DUTY SECTION IF WITHIN DRIVE
AISLE.
• STRUCTURAL PLANS IF WITHIN STORE
APRON BOUNDS.
a.. a
HEAVY DUTY PCC PAVEMENT SECTION:
=Io.6.0" PORTLAND CEMENT CONCRETE
• CLASS A
.4" CLASS 2 AGGREGATE BASE COURSE
• 95% RELATIVE COMPACTION
=r=- 12" MIN. COMPACTED SUBGRADE
-1-1-� • 95% RELATIVE COMPACTION
-I I I -I I I -I I I=
-I -I -I • MIN. COMPRESSIVE STRENGTH OF
III -III -III= 4000 PSI
• REINFORCE WITH #4 REBAR EACH WAY AT 12"
OC AT MID -DEPTH
LIGHT DUTY AC PAVEMENT SECTION:
�, - 3" AC PAVEMENT
CLASS 2 AGGREGATE BASE COURSE
• 95% RELATIVE COMPACTION
=11 a I mr=r
12" MIN. COMPACTED NATIVE SOIL
-III-III-I 11= _
=1=1=1 • 95% RELATIVE COMPACTION
I-
HEAVY DUTY AC PAVEMENT SECTION:
-4" AC PAVEMENT
CLASS 2 AGGREGATE BASE COURSE
• 95% RELATIVE COMPACTION
pi, I I I=1 11=
III -III -I 11I-I I-� 12" MIN. COMPACTED NATIVE SOIL
-III=
95% RELATIVE COMPACTION
1
BULLETIN # 1
LR
8/22/22
DZ
suffam
2
BULLETIN #2
LR
9/30/22
DZ
3
BULLETIN #3
LR
10/25/22
DZ
ROW - AS-BUILTS
LR
4/28/23
DZ
DrJM
a�cl�
NO.
REVISION
BY
I DATE
I APPR
ESTIMATED QUANTITIES:
CUT: 14 CY
IMPORT: 28 CY
FILL: 14 CY
THESE QUANTITIES DO NOT INCLUDE ANY SHRINKAGE,
SUBSIDENCE, OVER -EXCAVATION, OR ANY SPECIAL
CONDITIONS OR REQUIREMENTS THAT MAY BE SPECIFIED IN
THE GEOTECHNICAL INVESTIGATION REPORT. THESE QUANTITIES
IN THE AREA FOR PERMIT PURPOSES ONLY. ALL
CONTRACTORS BIDDING ON THIS PROJECT SHOULD MAKE
THEIR OWN DETERMINATION OF EARTHWORK QUANTITIES PRIOR
TO SUBMITTING A BID.
RECORD DRAWINGS
FHIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATIOP
'ROVIDED BY THE GENERAL CONTRACTOR AND ENGINEER OF RECORD
F� A N MO
WA
cow
g
fTl � 56573 ��
�FGISTE \�
S FSSIO NM_
SIM
APEX vmvrm: Ho ism
1" = 50' HOMMMA : we 1991
LR
LR am
DATUM
DZ N FILL BCiIIE
FN
DZ
LARS ANDERSEN & ASSOCIATES, INC.
CIVIL ENGINEERS - LAND SURVEYORS - PLANNERS
4694 WEST JACQUELYN AVENUE - FRESNO CALIFORNIA 93722
TEL: 559 27 -2790 FAX: 559 276-0850 WWW.LARSANDERSEN.COM
4/28/2023
SCOTT A. MOMMER RCE 56573 DATE:
CITY OF
RENTON
s
Planning/Building/Public Works Dept.
GENERAL GRADING NOTES:
1. CONCRETE WALKS TO HAVE 1.5% MAX CROSS SLOPE AND 5.0% MAX IN
DIRECTION OF TRAVEL. CONTRACTOR SHALL PROVIDE CERTIFICATION FROM
SURVEYOR AT JOB COMPLETION.
2. ALL GRADING SHALL COMPLY WITH STATE BUILDING CODE, CITY OF RENTON
STANDARDS AND SPECS„ AND SOILS REPORT.
3. CONTRACTOR TO ADJUST ALL EXISTING AND PROPOSED UTILITY LIDS TO
MATCH FLUSH WITH PROPOSED FINAL SURFACE GRADES. THIS INCLUDES BUT
IS NOT LIMITED TO THE FOLLOWING: MANHOLES, METER BOXES, VALVE BOXES,
ELECTRICAL BOXES, TELEPHONE BOXES, CABLE BOXES, AND TRANSFORMER
PADS.
4. ALL GRADING SHALL BE DONE UNDER THE OBSERVATION OF A GEOTECHNICAL
ENGINEER.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY FOR THE LOCATING AND PROTECTION OF ALL
UTILITIES.
6. DUST SHALL BE CONTROLLED BY WATERING AT ALL TIMES.
7. THE DEVELOPER AND/OR CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES
FORTY-EIGHT (48) HOURS PRIOR TO GRADING AT 811 UNDERGROUND SERVICE
ALERT.
8. ALL GRADING SHALL BE DONE IN CONFORMANCE WITH THE RECOMMENDATION
OF THE GEOTECHNICAL ENGINEERING INVESTIGATION REPORT PREPARED BY
TERRACON PROJECT NUMBER: 81195216 DATED: 12-27-2021 AND THE
RECOMMENDATIONS THEREIN ARE HEREBY MADE A PART HEREOF, AS
QUALIFIED CONTRACT DOCUMENTS.
9. ALL WORK WITHIN PUBLIC RIGHT OF WAYS MUST HAVE AN ENCROACHMENT PERMIT
ISSUED BY THE PUBLIC WORK'S OFFICE.
10. CONTRACTOR SHALL OBTAIN PERMIT TO GRADE FROM THE CITY BUILDING DEPARTMENT
AND SHALL GIVE ADEQUATE NOTICE FOR REQUIRED INSPECTIONS.
11. CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AS -GRADED PLANS.
PLANS ARE TO BE SUBMITTED UPON COMPLETION OF GRADING AND PRIOR TO
OCCUPANCY.
12. THE OVERALL BUILDING SITE SHALL HAVE A MINIMUM SLOPE OF 1.0% IN ALL
AREAS TO AN APPROVED DRAINAGE FACILITY. CONTRACTOR IS TO BLUE TOP
ANY AC PAVEMENT SLOPES UNDER 1.5% FOR CONFORMANCE WITH PLANS.
13. ANY VERTICAL CUT OR FILL DIFFERENTIAL EQUAL TO OR GREATER THAN
TWELVE (12) INCHES BETWEEN ADJACENT PROPERTIES SHALL BE SUPPORTED
BY AN APPROVED RETAINING WALL OR SHALL HAVE A MAXIMUM SLOPE OF
ONE (1) VERTICAL TO TWO (2) HORIZONTAL.
14. PROVIDE COMPACTION REPORTS PREPARED BY AN APPROVED TESTING AGENCY
FOR ALL FILLS.
15. PAVING SECTION SHALL BE INSPECTED BY THE GRADING ENGINEER OR BY A
CERTIFIED INSPECTOR.
16. ALL SITE CLEARING, EXCAVATIONS, FILLS, AND GRADING TO BE UNDER THE
DIRECTION OF A GEOTECHNICAL ENGINEER WITH FULL TIME OBSERVATION OF
THE ENGINEER OR HIS QUALIFIED REPRESENTATIVE. A SOILS INVESTIGATION
REPORT AND A REPORT OF SATISFACTORY PLACEMENT OF FILL, BOTH
ACCEPTABLE TO THE BUILDING OFFICIAL SHALL BE SUBMITTED.
17. NO SURFACE DRAINAGE SHALL BE PERMITTED TO DRAIN ONTO ADJACENT
PROPERTIES, OR PUBLIC PROPERTY.
18. CONTRACTOR SHALL PROVIDE CORING SAMPLES TO THE PROJECT ENGINEER
AFTER COMPLETION OF PAVING. SAMPLES SHALL BE SUPERVISED BY SOIL
ENGINEER. A FREQUENCY OF ONE CORE PER 10,000 SQ. FT. OF PAVING WITH
A TOTAL OF NO LESS THAN 4 CORES BE MET.
19. OPEN GRADED GRAVEL AND ROCK MATERIAL SUCH AS 3/4-INCH CRUSHED
ROCK OR 1/2-INCH CRUSHED ROCK SHOULD NOT BE USED AS BACKFILL
INCLUDING TRENCH BACKFILL. IN THE EVENT GRAVEL OR ROCK IS REQUIRED
BY A REGULATORY AGENCY FOR USE AS BACKFILL (CONTRACTOR TO OBTAIN A
LETTER FROM THE AGENCY STATING THE REQUIREMENT FOR ROCK AND/OR
GRAVEL AS BACKFILL), ALL OPEN GRADED MATERIALS SHALL BE FULLY
ENCASED IN A GEOTEXTILE FILTER FABRIC, SUCH AS MIRAFI 140N, TO
PREVENT MIGRATION OF FINE GRAINED SOILS INTO THE POROUS MATERIAL.
20. THE GRADING CONTRACTOR SHALL REMOVE ALL ORGANIC MATTER, DEBRIS,
AND OTHER DELETERIOUS MATERIAL FROM THE SITE.
GENERAL NOTES:
1. SEE SHEET C2.1 GRADING PLAN - SOUTH FOR ADDITIONAL
IMPROVEMENTS.
2. SEE SHEET CO.2 AND CO.3 FOR ADDITIONAL NOTES.
3. ALL EXISTING UTILITY STRUCTURES (MANHOLES, CLEANOUTS,
VAULTS, ETC) TO BE RAISED TO PROPOSED GRADE.
4. CONTRACTOR TO VERIFY EXISTING PAVEMENT SECTIONS AND
COORDINATE WITH GEOTECH ENGINEER PRIOR TO INSTALLATION
OF NEW PAVEMENTS.
R-422202
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HOME DEPOT
CIVIL CONSTRUCTION PERMIT
GRADING PLAN - NORTH