HomeMy WebLinkAboutT-422201W mm e1 I_ ' A 11Memp N 1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, i UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. O �i 2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. p W 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START I— OF CONSTRUCTION. 4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT UTILITY AGENCIES 48 HOURS O PRIOR TO COMMENCING WORK AND SHALL COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED W EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY. p Lij 6. THE CONTRACTOR SHALL SALVAGE AND DELIVER ALL EXISTING SIGNAL EQUIPMENT SPECIFIED FOR REMOVAL BACK TO CITY OF RENTON, C UNLESS OTHERWISE NOTED IN WRITING BY THE ENGINEER. O 7. THE LOCATIONS OF PROPOSED CONDUITS AND JUNCTION BOXES SHOWN IN THESE PLANS ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. 8. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS OF ALL PROPOSED FOUNDATIONS WITH THE ENGINEER PRIOR TO EXCAVATION. 9. PROPOSED JUNCTION BOXES LOCATED WITHIN SIDEWALKS AND CURB RAMPS SHALL BE EQUIPPED WITH SLIP -RESISTANT LIDS. 10. TYPE 1 AND TYPE 2 JUNCTION BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10. 11. THE CONTRACTOR SHALL LABEL ALL CONDUCTORS FOR SIGNAL EQUIPMENT WITHIN EACH JUNCTION BOX. 12. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THIS PLAN. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH LOCATION TO CONFIRM THAT THERE ARE NO CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED STREETLIGHT POLES PRIOR TO CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 13. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONDUCTORS ASSOCIATED WITH EXISTING SIGNAL EQUIPMENT SPECIFIED FOR REMOVAL, UNLESS OTHERWISE NOTED. CAP AND ABANDON EXISTING UNUSED CONDUIT. REMOVE PORTIONS OF ABANDONED CONDUIT WHERE IN CONFLICT WITH NEW CONDUIT, UNLESS OTHERWISE NOTED. 14. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 15. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 16. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). CONSTRUCTION NOTES: O PROTECT EXISTING POLE TO REMAIN. REMOVE EXISTING PUSHBUTTON SERVING EAST/WEST O CROSSING AND REPAIR HOLES IN POLE WITH WATERTIGHT SEAL AS APPROVED BY THE ENGINEER. INSTALL ACCESSIBLE PEDESTRIAN PUSHBUTTON POST O3 (PPB) WITH FOUNDATION PER WSDOT STANDARD PLAN J-20.10. INSTALL TWO APS PUSHBUTTON ASSEMBLIES ON POST PER WSDOT STANDARD PLAN J-20.26. O TRAFFIC WORK BY OTHERS. OROUTE NEW CONDUITS) AND CONDUCTORS INTO EXISTING JUNCTION BOX. O ADJUST JUNCTION BOX TO FINISHED GRADE. OEXISTING LOOP WIRES TO REMAIN AND BE PROTECTED IN PLACE. O INSTALL SIGN ON A -FRAME STAND STATING "CROSSWALK CLOSED, USE THIS CROSSWALK jeI Know what�s below. _. Call before you dig. S. GRADY WAY -------------------- - ------------ - - -�. - -- - - --------- -- ---------- ------ ------ - - -- -- - - - - - - -� ~` - ------- - - © 6 3 5 ... -- --r 2 1 3', 1 2' I 6 0 6 — — — — — — — — — — — — — — — - 3 I 5 3 4 5 5 i I .� 7 I WIRING SCHEDULE ® RACEWAY CONDUIT SIZE* VEH DIET 2C(SH) EVP DIET 3C(SH) PPB 2C(SH) VIDEO VDCC CABLE VEH/PED 5C ILLUM #8 OTHER NO. 1 EX 3" 4 (EX) 2 (EX) 2 (0) 1 8 (EX), 1 (0) 2 EX 2" 5 (EX) 2 (0), 2 1 (EX) 3 EX 4" 4 (EX) 3 (EX) 2 (0) 1 (EX), 1 12 (EX), 1 (0) 4 EX 3" 4 (EX) 1 (EX) 1 (0), 1 1 (0) 3 (EX), 1 (0) 2 (EX) 5 EX 4" 6 (EX) 1 (EX) 1 (0), 1 1 (0) 3 (EX), 1 (0) 6 1.5" SCH40 2 7 1" SCH40 1 * ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE EQUAL IN SIZE TO THE LARGEST CONDUCTOR (MINIMUM NO. 8) UNLESS OTHERWISE NOTED. EX - EXISTING 0 - TO BE ADDED BY OTHERS RECORD DRAWINGS THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED BY THE GENERAL CONTRACTOR AND ENGINEER OF RECORD. p�AN MO WA c0 � 56573 �v S OAF �FGISTER��\�� SS/ONAL_ 1 BULLETIN # 1 LR 8/22/22 DZ SURVEM 2 BULLETIN #2 LR 9/30/22 DZ DESIGI APEX aoKe 1" = 20, �VMM�Wb, 991 3 BULLETIN #3 LR 10/25/22 DZ LR ROW - AS-BUILTS LR 4/28/23 DZ DRAM LR am na, DATUM CHWIM a FULL soKE DZ F = = m NO. REVISION BY DATE APPR DZ W" A000"0"0u' LARS ANDERSEN & ASSOCIATES, INC. CIVIL ENGINEERS - LAND SURVEYORS - PLANNERS 4694 WEST JACQUELYN AVENUE - FRESNO CALIFORNIA 93722 TEL: 559 27 -2790 FAX: 559 276-0850 WWW.LARSANDERSEN.MO11 4/28/2023 SCOTT A. MOMMER RCE 56573 DATE: CITY OF RENTON s Planning/Building/Public Works Dept. LEGEND: -••—••—••- BOUNDARY LINE ---- MONUMENTED ROAD CENTERLINE - - PROPOSED R/W LINE ----------- ON -SITE LANDSCAPE BUFFER LINE E E EXISTING UNDERGROUND ELECTRICAL PROPOSED CONDUIT PROPOSED CONDUIT BY OTHERS a PROPOSED ACCESSIBLE PEDESTRIAN PUSHBUTTON (PPB) J❑ JUNCTION BOX PROPOSED CROSSWALK STRIPING T-422201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS HOME DEPOT CIVIL CONSTRUCTION PERMIT TRAFFIC SIGNAL PLAN 00 Cfl V_ M O O N N u H H N Q J C0 O O i ry n i oast 0- 10/12/2022 W FEUROM FML W mar�o Na TS1.0 2 O OHM 29 °F' 55