GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON
STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE
DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION.
2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION.
3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED
BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION.
4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE
APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING
LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR
SHALL CONTACT UTILITY AGENCIES 48 HOURS PRIOR TO COMMENCING WORK AND SHALL
COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM
CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY
IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED
EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY.
6. THE CONTRACTOR SHALL SALVAGE AND DELIVER ALL EXISTING LIGHTING EQUIPMENT
SPECIFIED FOR REMOVAL BACK TO CITY OF RENTON, UNLESS OTHERWISE NOTED IN
WRITING BY THE ENGINEER.
7. THE LOCATIONS OF PROPOSED CONDUITS AND JUNCTION BOXES SHOWN IN THESE PLANS
ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR SHALL FIELD VERIFY FINAL
LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION.
8. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS OF ALL PROPOSED FOUNDATIONS
WITH THE ENGINEER PRIOR TO EXCAVATION.
9. PROPOSED JUNCTION BOXES LOCATED WITHIN SIDEWALKS AND CURB RAMPS SHALL BE
EQUIPPED WITH SLIP -RESISTANT LIDS.
10. TYPE 1 BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10.
11. THE CONTRACTOR SHALL LABEL ALL CONDUCTORS FOR STREET LIGHTS WITHIN EACH
JUNCTION BOX.
12. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONDUCTORS ASSOCIATED WITH EXISTING
LIGHTING EQUIPMENT SPECIFIED FOR REMOVAL, UNLESS OTHERWISE NOTED. CAP AND
ABANDON EXISTING UNUSED CONDUIT. REMOVE PORTIONS OF ABANDONED CONDUIT WHERE
IN CONFLICT WITH NEW CONDUIT, UNLESS OTHERWISE NOTED.
13. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT
THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES.
HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE
PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THIS PLAN. AS THE
FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH LOCATION TO
CONFIRM THAT THERE ARE NO CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE
CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED
BETWEEN OVERHEAD POWER LINES AND THE PROPOSED STREETLIGHT POLES PRIOR TO
CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY.
THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS
DISCOVERED.
14. LUMINAIRE WIRING SHALL BE PER THIS PLAN AND CITY OF RENTON STANDARD PLAN 119.
15. STREET LIGHT POLES SHALL BE NUMBERED PER CITY OF RENTON STANDARD PLAN 121.
COORDINATE WITH THE CITY OF RENTON FOR NUMBERING.
16. FUSING AND/OR SPLICING OF LUMINAIRE WIRING SHALL BE PER CITY OF RENTON
STANDARD PLAN J013.
mil
7+15.95
It"M
-E -E E -E
LUMINAIRE POLE SCHEDULE
LUMINAIRE
RENTON POLE
CENTERLINE
STATION
OFFSET
LONGITUDE
LATITUDE
LUMEN OUTPUT
MOUTING
ARM
WATTAGE
DISTRIBUTION
LUMINAIRE TYPE
NOTES
POLE NO.
NO.**
REFERENCE
***
***
HEIGHT
LENGTH
4 *
S. GRADY WAY
10+76.7
42.9 FT RT
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
0*
S. GRADY WAY
1 1 +37.4
43.3 FT RT
23,200 (ROADWAY)
35FT,
8FT,
120W,
III,
CYCLONE DOMIA (ROADWAY),
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
0*
S. GRADY WAY
1 1 +96.9
34.9 FT RT
2,582 (PEDESTRIAN)
1 6.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
4
S. GRADY WAY
12+61.3
33.9 FT RT
23,200 (ROADWAY)
35FT,
8FT,
120W,
III,
CYCLONE DOMIA (ROADWAY),
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
0*
S. GRADY WAY
13+20.7
34.1 FT RT
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
S. GRADY WAY
13+82.4
35.2 FT RT
23,200 (ROADWAY)
35FT,
8FT,
120W,
III,
CYCLONE DOMIA (ROADWAY),
*
O
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
0*
S. GRADY WAY
14+79.4
33.9 FT RT
23,200 (ROADWAY)
35FT,
8FT,
120W,
III,
CYCLONE DOMIA (ROADWAY),
DS
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
0*
S. GRADY WAY
15+36.4
33.3 FT RT
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
DS
S. GRADY WAY
15+95.9
33.7 FT RT
23,200 (ROADWAY)
35FT,
8FT,
120W,
III,
CYCLONE DOMIA (ROADWAY),
*
0
DS
2,582 (PEDESTRIAN)
16.5FT
4FT
20W
III
CYCLONE DOMIA MINI (ROADWAY)
GENERAL NOTES CONTINUED
17. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE
IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES,
LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
18. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL
GRADE ONCE CONSTRUCTION IS COMPLETE.
19. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT
CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL
HAVE NON-SKID LIDS).
20. LUMINAIRE FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
21. ALL ILLUMINATION SYSTEM ARE SUBJECT TO INSPECTION BY CITY OF RENTON
TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE.
CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS
MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE ----
REPRESENTATIVE.
22. CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL,
(425) 430-7423 FOR STREET LIGHTING INSPECTION PRIOR TO ENERGIZING.
23. THE CONTRACTOR SHALL SUBMIT, FOR REVIEW BY THE ENGINEER, DESIGNS FOR THE
LUMINAIRE POLE FOUNDATIONS THAT BEAR THE SEAL AND SIGNATURE OF A VALID LICENSED
WASHINGTON STATE PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY STRUCTURAL AND/OR GEOTECHNICAL ANALYSIS THAT MAY BE NEEDED TO
DETERMINE THE NECESSARY FOUNDATION DEPTHS FOR THE ARTERIAL STREET DECORATIVE
LUMINAIRE POLES AND THE ARTERIAL PEDESTRIAN LUMINAIRE POLES, IN ACCORDANCE WITH
CITY OF RENTON STANDARD PLANS 117.1 AND 117.2. A GEOTECHNICAL ENGINEER SHALL
BE PRESENT AT THE TIME OF BORING OF THE FOUNDATION TO VERIFY SOIL CONDITIONS.
LEGEND
* CITY OF RENTON LIGHTING
** CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, EREC CUTSHALL (425
430-7423 FOR POLE NUMBERS TO BE INCLUDED ON POLES.
*** CONTRACTOR SHALL DETERMINE FINAL COORDINATES FOR RECORD DRAWINGS.
DS - DEFERRED SUBMITTAL. LIGHT POLE BASE INSTALLED AS OF 4/20/2023 UNDER CITY DEFERRAL
AGREEMENT. FULL LIGHT POLE INSTALLATION REQUIRED UPON MATERIAL AVAILABILITY.
1
BULLETIN
# 1
LR
8/22/22
DZ
suffam
2
BULLETIN
#2
LR
9/30/22
DZ
DomNm
3
BULLETIN
#3
LR
10/25/22
DZ
ROW - AS-BUILTS
LR
4/28/23
DZ
ova%
NO. REVISION
0.
RECORD DRAWINGS
THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION
PROVIDED BY THE GENERAL CONTRACTOR AND ENGINEER OF RECORD.
p�AN M LARS ANDERSEN & ASSOCIATES, INC.
WA Sy�0'�l CIVIL ENGINEERS - LAND SURVEYORS - PLANNERS
o�� TEL: WEST JACQU-2790 LYF AVENUE - FR50 .LABS NIANDE 9372M
TEL: 559 27 -2790 FAX: 559 276-0850 WWW.LARSANDERSEN.COP1
� Z
56573
S OAF �FGISTER��\� 4/28/2023
SS�ONAL_ SCOTT A. MOMMER RCE 56573 DATE:
aoKe
APEX 1" = 30' � , ", CITY OF
LR RENTON
LR am NCR °
DZ N Fsc� DATUM
u planning/Building/Public Works Dept.
sWrOWM
90" N0001IMM ur
DZ
GENERAL NOTES:
1. ALL CONSTRUCTION MATERIALS FOR TRAFFIC SIGNS,
TRAFFIC STRIPING, PAVEMENT MARKERS, AND PAVEMENT
MARKINGS SHALL BE FURNISHED AND INSTALLED BY
THE CONTRACTOR.
2. ALL LIGHTING INSTALLATIONS TO BE MADE PER CITY OF
RENTON STANDARD DETAILS AND PLANS.
3. ALL STREET LIGHTS TO EXTEND 2-FEET INTO THE
STREET. CONTRACTOR TO MOVE FOUNDATION OR
INCREASE ARM LENGTH ACCORDINGLY IF NOT. IF THE
FOUNDATION IS SHIFTED CLOSER TO THE CURB, ALL
NEW STREETLIGHT FOUNDATIONS MUST BE SHIFTED
EQUALLY FOR UNIFORM INSTALLATION.
CONSTRUCTION NOTES:
INSTALL DECORATIVE LUMINAIRE POLE PER RENTON
Q CITY STD PLAN 117.1. CONNECT TO EXISTING
ELECTRICAL CONDUIT PER CITY STANDARDS.
O INSTALL DECORATIVE PEDESTRIAN LUMINAIRE POLE PER
RENTON CITY STD PLAN 117.2. CONNECT TO EXISTING
ELECTRICAL CONDUIT PER CITY STANDARDS.
30 EXISTING 1 4" ELECTRICAL CONDUIT. CONTRACTOR TO
CONFIRM SIZE AND LOCATION.
O PROPOSED DECORATIVE LUMINAIRE POLE BY OTHERS
O INSTALL TYPE 1 JUNCTION BOX.
INTERCEPT EXISTING CONDUIT WITH NEW CONDUIT
Os IN -KIND AND ROUTE CONDUIT INTO NEW JUNCTION
BOX. SPLICE CONDUCTORS INTO EXISTING
ILLUMINATION CIRCUIT.
O PROTECT EXISTING LUMINAIRE AND POLE TO REMAIN.
IMPROVEMENT LEGEND:
E E
EXISTING UNDERGROUND CONDUIT
�--��
PROPOSED LUMINAIRE POLE
J❑
EXISTING JUNCTION BOX
o
EXISTING SIGNAL POLE
®
PROPOSED JUNCTION BOX TYPE 1
PROPOSED CONDUIT
Know WN aft below.
Cal I before you dig.
T-422204
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
oast
10/12/2022
HOME DEPOT FEUROM
CIVIL CONSTRUCTION PERMIT PM
� Na
ROW LIGHTING PLAN IL1.0