Loading...
HomeMy WebLinkAboutT-422204N N N O W I- 0 0- LU 0 LU 0 19.88, (TO CORNER SIGIII-----___ GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT UTILITY AGENCIES 48 HOURS PRIOR TO COMMENCING WORK AND SHALL COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY. 6. THE CONTRACTOR SHALL SALVAGE AND DELIVER ALL EXISTING LIGHTING EQUIPMENT SPECIFIED FOR REMOVAL BACK TO CITY OF RENTON, UNLESS OTHERWISE NOTED IN WRITING BY THE ENGINEER. 7. THE LOCATIONS OF PROPOSED CONDUITS AND JUNCTION BOXES SHOWN IN THESE PLANS ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. 8. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS OF ALL PROPOSED FOUNDATIONS WITH THE ENGINEER PRIOR TO EXCAVATION. 9. PROPOSED JUNCTION BOXES LOCATED WITHIN SIDEWALKS AND CURB RAMPS SHALL BE EQUIPPED WITH SLIP -RESISTANT LIDS. 10. TYPE 1 BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10. 11. THE CONTRACTOR SHALL LABEL ALL CONDUCTORS FOR STREET LIGHTS WITHIN EACH JUNCTION BOX. 12. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONDUCTORS ASSOCIATED WITH EXISTING LIGHTING EQUIPMENT SPECIFIED FOR REMOVAL, UNLESS OTHERWISE NOTED. CAP AND ABANDON EXISTING UNUSED CONDUIT. REMOVE PORTIONS OF ABANDONED CONDUIT WHERE IN CONFLICT WITH NEW CONDUIT, UNLESS OTHERWISE NOTED. 13. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THIS PLAN. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH LOCATION TO CONFIRM THAT THERE ARE NO CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED STREETLIGHT POLES PRIOR TO CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 14. LUMINAIRE WIRING SHALL BE PER THIS PLAN AND CITY OF RENTON STANDARD PLAN 119. 15. STREET LIGHT POLES SHALL BE NUMBERED PER CITY OF RENTON STANDARD PLAN 121. COORDINATE WITH THE CITY OF RENTON FOR NUMBERING. 16. FUSING AND/OR SPLICING OF LUMINAIRE WIRING SHALL BE PER CITY OF RENTON STANDARD PLAN J013. mil 7+15.95 It"M -E -E E -E LUMINAIRE POLE SCHEDULE LUMINAIRE RENTON POLE CENTERLINE STATION OFFSET LONGITUDE LATITUDE LUMEN OUTPUT MOUTING ARM WATTAGE DISTRIBUTION LUMINAIRE TYPE NOTES POLE NO. NO.** REFERENCE *** *** HEIGHT LENGTH 4 * S. GRADY WAY 10+76.7 42.9 FT RT 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 0* S. GRADY WAY 1 1 +37.4 43.3 FT RT 23,200 (ROADWAY) 35FT, 8FT, 120W, III, CYCLONE DOMIA (ROADWAY), 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 0* S. GRADY WAY 1 1 +96.9 34.9 FT RT 2,582 (PEDESTRIAN) 1 6.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 4 S. GRADY WAY 12+61.3 33.9 FT RT 23,200 (ROADWAY) 35FT, 8FT, 120W, III, CYCLONE DOMIA (ROADWAY), 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 0* S. GRADY WAY 13+20.7 34.1 FT RT 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) S. GRADY WAY 13+82.4 35.2 FT RT 23,200 (ROADWAY) 35FT, 8FT, 120W, III, CYCLONE DOMIA (ROADWAY), * O 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 0* S. GRADY WAY 14+79.4 33.9 FT RT 23,200 (ROADWAY) 35FT, 8FT, 120W, III, CYCLONE DOMIA (ROADWAY), DS 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) 0* S. GRADY WAY 15+36.4 33.3 FT RT 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) DS S. GRADY WAY 15+95.9 33.7 FT RT 23,200 (ROADWAY) 35FT, 8FT, 120W, III, CYCLONE DOMIA (ROADWAY), * 0 DS 2,582 (PEDESTRIAN) 16.5FT 4FT 20W III CYCLONE DOMIA MINI (ROADWAY) GENERAL NOTES CONTINUED 17. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 18. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 19. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 20. LUMINAIRE FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 21. ALL ILLUMINATION SYSTEM ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE ---- REPRESENTATIVE. 22. CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL, (425) 430-7423 FOR STREET LIGHTING INSPECTION PRIOR TO ENERGIZING. 23. THE CONTRACTOR SHALL SUBMIT, FOR REVIEW BY THE ENGINEER, DESIGNS FOR THE LUMINAIRE POLE FOUNDATIONS THAT BEAR THE SEAL AND SIGNATURE OF A VALID LICENSED WASHINGTON STATE PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY STRUCTURAL AND/OR GEOTECHNICAL ANALYSIS THAT MAY BE NEEDED TO DETERMINE THE NECESSARY FOUNDATION DEPTHS FOR THE ARTERIAL STREET DECORATIVE LUMINAIRE POLES AND THE ARTERIAL PEDESTRIAN LUMINAIRE POLES, IN ACCORDANCE WITH CITY OF RENTON STANDARD PLANS 117.1 AND 117.2. A GEOTECHNICAL ENGINEER SHALL BE PRESENT AT THE TIME OF BORING OF THE FOUNDATION TO VERIFY SOIL CONDITIONS. LEGEND * CITY OF RENTON LIGHTING ** CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, EREC CUTSHALL (425 430-7423 FOR POLE NUMBERS TO BE INCLUDED ON POLES. *** CONTRACTOR SHALL DETERMINE FINAL COORDINATES FOR RECORD DRAWINGS. DS - DEFERRED SUBMITTAL. LIGHT POLE BASE INSTALLED AS OF 4/20/2023 UNDER CITY DEFERRAL AGREEMENT. FULL LIGHT POLE INSTALLATION REQUIRED UPON MATERIAL AVAILABILITY. 1 BULLETIN # 1 LR 8/22/22 DZ suffam 2 BULLETIN #2 LR 9/30/22 DZ DomNm 3 BULLETIN #3 LR 10/25/22 DZ ROW - AS-BUILTS LR 4/28/23 DZ ova% NO. REVISION 0. RECORD DRAWINGS THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED BY THE GENERAL CONTRACTOR AND ENGINEER OF RECORD. p�AN M LARS ANDERSEN & ASSOCIATES, INC. WA Sy�0'�l CIVIL ENGINEERS - LAND SURVEYORS - PLANNERS o�� TEL: WEST JACQU-2790 LYF AVENUE - FR50 .LABS NIANDE 9372M TEL: 559 27 -2790 FAX: 559 276-0850 WWW.LARSANDERSEN.COP1 � Z 56573 S OAF �FGISTER��\� 4/28/2023 SS�ONAL_ SCOTT A. MOMMER RCE 56573 DATE: aoKe APEX 1" = 30' � , ", CITY OF LR RENTON LR am NCR ° DZ N Fsc� DATUM u planning/Building/Public Works Dept. sWrOWM 90" N0001IMM ur DZ GENERAL NOTES: 1. ALL CONSTRUCTION MATERIALS FOR TRAFFIC SIGNS, TRAFFIC STRIPING, PAVEMENT MARKERS, AND PAVEMENT MARKINGS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. 2. ALL LIGHTING INSTALLATIONS TO BE MADE PER CITY OF RENTON STANDARD DETAILS AND PLANS. 3. ALL STREET LIGHTS TO EXTEND 2-FEET INTO THE STREET. CONTRACTOR TO MOVE FOUNDATION OR INCREASE ARM LENGTH ACCORDINGLY IF NOT. IF THE FOUNDATION IS SHIFTED CLOSER TO THE CURB, ALL NEW STREETLIGHT FOUNDATIONS MUST BE SHIFTED EQUALLY FOR UNIFORM INSTALLATION. CONSTRUCTION NOTES: INSTALL DECORATIVE LUMINAIRE POLE PER RENTON Q CITY STD PLAN 117.1. CONNECT TO EXISTING ELECTRICAL CONDUIT PER CITY STANDARDS. O INSTALL DECORATIVE PEDESTRIAN LUMINAIRE POLE PER RENTON CITY STD PLAN 117.2. CONNECT TO EXISTING ELECTRICAL CONDUIT PER CITY STANDARDS. 30 EXISTING 1 4" ELECTRICAL CONDUIT. CONTRACTOR TO CONFIRM SIZE AND LOCATION. O PROPOSED DECORATIVE LUMINAIRE POLE BY OTHERS O INSTALL TYPE 1 JUNCTION BOX. INTERCEPT EXISTING CONDUIT WITH NEW CONDUIT Os IN -KIND AND ROUTE CONDUIT INTO NEW JUNCTION BOX. SPLICE CONDUCTORS INTO EXISTING ILLUMINATION CIRCUIT. O PROTECT EXISTING LUMINAIRE AND POLE TO REMAIN. IMPROVEMENT LEGEND: E E EXISTING UNDERGROUND CONDUIT �--�� PROPOSED LUMINAIRE POLE J❑ EXISTING JUNCTION BOX o EXISTING SIGNAL POLE ® PROPOSED JUNCTION BOX TYPE 1 PROPOSED CONDUIT Know WN aft below. Cal I before you dig. T-422204 IN COMPLIANCE WITH CITY OF RENTON STANDARDS oast 10/12/2022 HOME DEPOT FEUROM CIVIL CONSTRUCTION PERMIT PM � Na ROW LIGHTING PLAN IL1.0 ' 32 °F' 55 00 Cfl M O O N N 1 LJ H H N Q J L0 O O O O N 0 a_ LLI 0 LLI 2 0