Loading...
HomeMy WebLinkAboutT-422206N N I ^I IJ W I - F- O w 0 w O INSTALL DECAL NUMBERS VERTICALLY. INSTALL IN DRY WEATHER, 50° F OR ABOVE I NUMBERING EXAMPLES LED TYPE WATTAGE H- w LJ Ln CURB �9 _ + A5 � z TRAFFIC FLOW CD FOR STD PLAN 117.1 FOR STD PLAN 116.1,117.2, 117.4 1-3 4' TO 2' 0.88" o\ \t I N n N ~ �y■ DECAL: REFLECTORV ED GOTHIC GOLD OR WHITE LEGEND ON BLACK BACKGROUND STREET LIGHT STANDARD STD. PLAN- 121 PUBLIC WORKS DECAL NUMBERING SYSTEM PRC DEPARTMENT ANTFf 46n A DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E SHIM TO PLUMB 2 SEE NOTE 3 SHIM TO PLUMB SEE NOTE 3 NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES FOR THE CONTROLLER AND CONTACTOR CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STO PLAN 135, 7. 2" CONDUIT SHALL BE PLACED FROM THE COMBINED BBS/CONTACTOR TO THE CONTROLLER CABINET. 8. EACH CABINET SHALL HAVE A %" DIAMETER PLASTIC DRAIN PIPE. 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS. 10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. 11. WOODEN SHIMS SHALL NOT BE USED 12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3 //4 HOOPS SHIM TO PLUMB (EQUAL SPACES) SEE NOTE 3 4J 2" IIIIII I L 6" MIN 1" TO 2' AC FRONT wEw 3 - #4 REINFORCING BAR (EQUAL SPES) DIAMETER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 5 SEE NOTE 7 3/8" DIAMETER PLASTIC DRAIN SEE NOTE 5 a m _�D U 0w>=` u ZUU tt HORIZONTAL COMBINED FOUNDATION REINF. BAR DIAGRAM 6 PIECES #4 HOOPS 3 - #4 REINFORCING BAR (EQUAL SPACES) CONTROLLER CONBTACTOR CABINET CABINET 10" WDTH 5- WIDTH 10" + 1" + 2• PLAN VIEW COMBINED CONTROLLER/BBS/CONTACTOR FOUNDATION CABINET FOUNDATION PUBLIC WORKS DETAILS a DEPARTMENT STD. PLAN - 126.2 139VED: 3/13/2019 1 4:1 �- DATE DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 Z ID O O m N � 000� DODO � m - 7. N n N z N °0 z M v ¢ W a o r o N Of a 0 Z 0... z Q � 0 V 00 a ' 0 IL w tI O N 0 w W............ N 0 C._ o w LU - O m O wOf H(�xx W UjwC]F O� w Z U U> J x w w Z-- a Fn CO H H Z m�=1-w a am U W= a 0 0 z 0 U xa~zx wawa l-Z��H �wml- QWw wx ��� ml-Qp o L=i wW F- �Zxw °W w3 1n U) w Q _ 0 w F aL1 �m w mmQ- U)-C7 � z�zLU �UZLL =_ 0 zF_a Owxw LU-J ad0_ <LZ F_ LLi wo3 Tn00 a co w�=0 F-LU LU a F_ a_ 0 � Z LU w wZ)w V) cWa wwjw x 2 Z z Ho�F co wQZ_ LU CD Q = w Y N J >H z Q O > a CO MIA z c� � Z� wm M H_ Daw 0 w w U U Ir PUBLIC WORKS 2­9 SERVICE CABINET ppPROVE:PLAN - 122.1 �•� EPAR MENTBn PaStuCfYd8/2021 1 4: N 10 DATE DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E GENERAL NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS(I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 7. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. 8. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. Gti TRANSPORTATION NOTES STD. PLAN - 135 ®� PUBLIC WORKS A ROVED: DEPARTMENT GAZ 3/13/2019 1 4 DATE 31 1 DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 COMPONEN I SCHIEIUULE OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5TH JAW AT 9:00 POSITION O PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, IOK AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 40/1 SIGNAL (IF PRESENT) 1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 1511 CONTROL 3 - 20/1 SPARE O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891ODPA34VO2 -I REQUIRED 4O PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW SO PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKE(S) SHALL BE ADDED WHEN APPLICABLE U�c O PUBLIC WORKS SERVICE CABINET NOTES ZD,wPLAN - 122.2 ,��pp � DEPARTMENT M BPFtI IOIV0a$tu Cha 8/2021 1 4 : N 8B8131 8 44 ... DATE "BAND• - -- _ --- OR MOUNTING ON EXISTING METAL POLE OR LUMINAIRE 4" MIN. T EDGE OF t" "zjj_cAt""" c GALVANIZED BOLT WITH GALVANIZED WASHERS. NOTES 1. DIMENSIONS FOR THE PARTS USED TO ASSEMBLE THE BASE CONNECTIONS ARE INTENTIONALLY NOT SHOWN. BASE CONNECTIONS ARE PATENTED, MANUFACTURED PRODUCTS THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST CRITERIA. THE BASE CONNECTION DETAILS ARE SHOWN ON THIS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE ASSEMBLED. 2. A 2- (IN) POST WITH A 2 1/4- (IN) PSST ANCHOR OR A 2 1/4- (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE SUBSTITUTED. SEE CONTRACT PLANS. 3. PERFORATED SQUARE STEEL POST SHALL MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 9-06. 4. USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED HARDWARE THAT MEETS THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS 9-06 AND 9-28. EDGE OF TRAVELED / ROADWAY 30'---•1 90' FOR REFLECTORIZED SIGNS: MOUNT FACING 3*(degree) OUTWARD IF SIGN IS WITHIN 30 FEET OF ROADWAY 81014 FACE ORIEIIII II SIGN POST -- o: LINGLINtlIl O LOWER SIGN POST 5 16" IN CORNER BOLT 3/ FLANGED SUPPORT (IN) SHOULDER BOLT WITH NUT AND WASHERS �• 2 REQUIRED (TYP.) 8 T STOP GN POST IY `> TYPE STA SIGN SUPPORT t LOWER SIGN POST SUPPORT - 2.25" (IN), 7-GAGE. HOT -DIP GALV., IN. " HEAVY-DUTY ANCHOR IAM I'"YFRCIAL CONCRETE MOUNTING ON METAL POST SIGN MOUNTING ON SINGLE STD. PLAN- 129 ®) PUBLIC WORKS DEPARTMENT METAL POST APPROVED: (ADOPTED) 6-Z- I.w 3: DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E CONDUIT ENTRANCE AREA •oao.9. PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET -GRADE LEVEL N < N FRONT VIEW , SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION El SHIM TO PLUMB _ SEE NOTE 3 o #4 HOOPS IIT #4 BAR�� CORNER 6" MIN 1" TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH 1'-6" + 2" 1'-6" IIII �� 1 #4 BAR EACH + 1 A A #4 CORNER W Z _HOOPS CID- - - -1-114- IIII Liu PLAN VIEW CONTROLLER CABINET FOUNDATION NOTES PER STD PLAN 126.2 CABINET FOUNDATION STD. PLAN - 126.1 DETAILS APPgOVED: Z 3/13/2019 I DATE T. 20, DIAMETER = 7/8" 4-7/8" 1/4" LOAD LINE 1/4" FUSE O CUTTING RINGS FUSE KIT VV 1 C Jt-LILC SPLICE KIT FUSE KIT & SPLICE KIT DETAILS O ADOPTED G, CITY OF RENTON STANDARD PLANS N'T 1ST DATE: 04/04 _.......... _.. .___, nwr. NAUP- .Ir)11 CP PAr F'.Ini 7 RECORD DRAWINGS THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED BY THE GENERAL CONTRACTOR AND ENGINEER OF RECORD. PEA N Mo LARS ANDERSEN & ASSOCIATES, INC. � pE WA CIVIL CIVIL ENGINEERS - LAND SURVEYORS - PLANNERS 0 Q )P` ` �iCo'�� 4694 WEST JACQUELYN AVENUE - FRESNO CALIFORNIA 93722 TEL: 559 27 -2790 FAX: 559 276-0850 WWW.LARSANDERSEN.COM y 56573 �v -4/28/2023 o�FSS�ONAL�-SCOTT A. MOMMER RCE 56573 DATE: 1 BULLETIN #1 LR 8/22/22 DZ SURVI APEX 912111M VWCA_ Imo 1 2 BULLETIN #2 LR 9/30/22 DZ I I In,NOCITY OF 3 BULLETIN #3 LR 10/25/22 DZ LR ROW - AS-BUILTS LR 4/28/23 DZ ° LR ow rm %4�0 RENTON TO' CHEMM DZ AT FULL 91 DATUM planning/Building/Public Works Dept. A000 NO. REVISION BY DATE APPR o 11,ar wa1 APP110VED: DZ 9GLE IiDpOLY :l T-422206 IN COMPLIANCE WITH CITY OF RENTON STANDARDS HOME DEPOT CIVIL CONSTRUCTION PERMIT ROW LIGHTING DETAILS 00 C-0 r C) C) N N 1 LJ r N J i IolaFt 0- 10/12/2022 W FELINOM Q FML W ma IL1.2 2 OHM 34 °F 55 O 2