Loading...
HomeMy WebLinkAboutR-396402w J w z 0 m U U) 75 m 0 N 0 N \ 00 N 0 E \ 0 3 0 E 0 N 0 00 i m 0 / X W m 0 a / N 0 00 i 0 0 O 00 L� Q0 C) I Q w THE BINDING SITE PLAN AMENDMENT, SITE PLAN, AND A STREET MODIFICATION ARE APPROVED SUBJECT TO THE FOLLOWING CONDITIONS. 1. THE APPLICANT SHALL COMPLY WITH THE MITIGATION MEASURES ISSUED AS PART OF THE DETERMINATION OF NON —SIGNIFICANCE — MITIGATED, DATED FEBRUARY 3, 2017. 2. THE APPLICANT SHALL SUBMIT A FINAL DETAILED LANDSCAPE PLAN TO, AND APPROVED BY, THE CURRENT PLANNING PROJECT MANAGER PRIOR TO BUILDING PERMIT APPROVAL. LAND USE CONDITIONS FOR UW MEDICINE -VALLEY MEDICAL CENTER MEDICAL OFFICE BUILDING EXPANSION 6. THE APPLICANT SHALL SUBMIT A FINAL MITIGATION PLAN FOR ALL CONSTRUCTION IMPACTS TO THE CRITICAL AREAS AND THEIR BUFFERS. THE FINAL MITIGATION PLAN SHALL BE SUBMITTED TO AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO THE NORTH PARKING GARAGE EXPANSION BUILDING PERMIT APPROVAL. 7. THE APPLICANT SHALL COMPLY WITH THE REQUIRED ACCESS ROADWAYS WITHIN 150 FEET OF ALL POINTS ON THE BUILDINGS OR OBTAIN AN ACCESS VARIANCE FROM THE RENTON FIRE AUTHORITY PRIOR TO BUILDING PERMIT ISSUANCE. 8. THE APPLICANT SHALL COMPLY WITH THE FOLLOWING INTERSECTION IMPROVEMENTS AT TALBOT RD 3. THE APPLICANT SHALL PROVIDE A REVISED REFUSE AND RECYCLING ENCLOSURE PLAN THAT PROVIDES S/VMC NORTH ACCESS RD—S 177TH ST INTERSECTION PRIOR TO CERTIFICATE OF OCCUPANCY OF THE A DETAIL CUT —SHEET OF THE SELF —CLOSING DOOR MECHANISM AND INCLUDES A ROOF OVER THE PROPOSED NEW MEDICAL OFFICE BUILDING (MOB): STORAGE AREA (OR ANY FUTURE PROPOSED REFUSE AND RECYCLING STORAGE AREAS ONSITE). THE PLAN a. RELOCATE THE VMC NORTH DRIVEWAY TO ALIGN WITH S 177TH ST; SHALL BE SUBMITTED TO, AND APPROVED BY, THE CURRENT PLANNING PROJECT MANAGER PRIOR TO b. INSTALL A SIGNAL WITH PERMISSIVE PHASING; BUILDING PERMIT APPROVAL. C. ADD TWO (2) 100—FOOT LONG EASTBOUND LANES FROM THE VMC SITE TO TALBOT RD S, ONE OF THE LANES WOULD BE THROUGH LEFT AND THE OTHER WOULD BE RIGHT ONLY; 4. THE APPLICANT SHALL SUBMIT A PLAN THAT INCLUDES 21 ACCESSIBLE STALLS, AS STIPULATED IN THE d. ADD A DROP RIGHT TURN LANE FROM THE SOUTHBOUND APPROACH FROM TALBOT RD S TO THE AMERICANS WITH DISABILITIES ACT (ADA), BETWEEN THE SURFACE PARKING STALLS LOCATED ON THE VMC SITE; MEDICAL OFFICE BUILDING (MOB) LOT (PROPOSED LOT 4) AND THE NORTH PARKING GARAGE e. PROVIDE A WIDER THROAT FOR THE VMC NORTH DRIVEWAY INBOUND LANE FROM TALBOT RD EXPANSION LOT (PROPOSED LOT 8). 5. UNDER THE REQUESTED STREET MODIFICATION, THE APPLICANT SHALL COMPLY WITH THE FOLLOWING STREET IMPROVEMENTS: a. A 10—FOOT RIGHT—OF—WAY DEDICATION SHALL BE MADE ALONG TALBOT ROAD S. ON PARCELS 8857670100, 8857670110, 31223059085, AND 3123059065. b. THE 0.5' CURB AND 6' SIDEWALK SHALL REMAIN IN PLACE ALONG THE ENTIRETY OF THE TALBOT RD S FRONTAGE. C. A 12—FOOT RIGHT—OF—WAY DEDICATION SHALL BE MADE ALONG S 43RD ST ON PARCEL 8857670100 AND RIGHT—OF—WAY DEDICATION RESULTING IN A 35—FOOT RADIUS AT THE NORTHWEST CORNER OF S 43RD ST AND TALBOT RD S. d. ALL EXISTING DRIVEWAYS AND RAMPS (INCLUDING COMPANION RAMPS) ALONG THE TALBOT RD S AND S 43RD ST SHALL BE BROUGHT UP TO CURRENT ADA STANDARDS. PIGMENT SHALL BE ADDED TO THE REPLACED CONCRETE IN ORDER TO MATCH THE EXISTING SIDEWALK AND CONCRETE curbs. e. ALL UTILITIES AND OVERHEAD POWER LINES MUST BE UNDERGROUNDED WITHIN THE PROPOSED INTERSECTION IMPROVEMENTS AT TALBOT RD S/VMC NORTH ACCESS RD—S 177TH ST. f. ALL REQUIRED STREET LIGHTING AT THE PROPOSED INTERSECTION IMPROVEMENTS AT TALBOT RD S/VMC NORTH ACCESS RD—S 177TH ST SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE AT 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. HORIZONTAL CONTROL NOTE: CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. MONUMENT DEMOLITION NOTE: CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR OBTAINING PERMITS FROM ANY JURISDICTIONS HAVING AUTHORITY FOR REMOVING AND REPLACING ALL SURVEY MONUMENTATION THAT MAY BE AFFECTED BY CONSTRUCTION ACTIVITY. UPON COMPLETION OF CONSTRUCTION, ALL MONUMENTS DISPLACED, REMOVED, OR DESTROYED SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR, AT THE COST AND AT THE DIRECTION OF THE CONTRACTOR, PURSUANT TO THESE REGULATIONS. THE APPROPRIATE FORMS FOR REPLACEMENT OF SAID MONUMENTATION SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR. V0 ASS 42 n U 2 2s� CO <T"HG ENGIN�� S; f. INSTALL ALL CURB RETURNS TO CITY STANDARDS; g. INSTALL ALL CURB RAMPS AND CROSSWALKS TO CITY AND ADA STANDARDS; AND h. INSTALL ACCESSIBLE PEDESTRIAN SIGNALS (APS). 9. THE APPLICANT SHALL REPLACE THE CENTRAL DRIVEWAY BEACON WITH A RECTANGULAR RAPID FLASHING BEACON (RRFB) TO INCREASE PEDESTRIAN SAFETY. THE PEDESTRIAN SIGNAL PLAN SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER AND THE CITY OF RENTON PUBLIC WORKS TRANSPORTATION DIVISION PRIOR TO BUILDING PERMIT APPROVAL. 10. THE APPLICANT SHALL SUBMIT A CHANNELIZATION PLAN FOR REVIEW AND APPROVAL BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER AND THE CITY OF RENTON PUBLIC WORKS TRANSPORTATION DIVISION PRIOR TO BUILDING PERMIT APPROVAL. 11. THE APPLICANT SHALL MAKE BUS SHELTER IMPROVEMENTS TO THE TWO (2) EXISTING BUS STOPS CONSISTING OF ACCESSIBLE BOARDING AREAS, SHELTER FOOTINGS, AND QUEUEING AND WAITING AREAS FOR TRANSIT USERS AT THE INTERSECTION OF TALBOT RD S AND S 177TH ST INTERSECTION. CIVIL CONSTRUCTION PLANS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE CITY OF RENTON PLAN REVIEW PROJECT MANAGER PRIOR TO ISSUANCE OF THE RIGHT—OF—WAY CONSTRUCTION PERMIT FOR THE SIGNALIZED INTERSECTION. ALL REQUIRED BUS SHELTER IMPROVEMENTS SHALL BE COMPLETED PRIOR TO CERTIFICATE OF OCCUPANCY OF THE NEW MEDICAL OFFICE BUILDING (MOB). 12. THE APPLICANT SHALL SUBMIT A LIGHTING PLAN THAT ADEQUATELY PROVIDES FOR PUBLIC SAFETY WITHOUT CASTING EXCESSIVE GLARE ON ADJACENT PROPERTIES; PROVIDES ORNAMENTAL LIGHTING FIXTURES; AND OTHERWISE COMPLIES WITH EXTERIOR LIGHTING REQUIREMENTS OF RMC 4-4-075. THE FINAL LIGHTING PLAN SHALL BE SUBMITTED TO AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO BUILDING PERMIT APPROVAL. 13. THE APPLICANT SHALL SUBMIT A DETAILED SEQUENCING PLAN WITH DEVELOPMENT PHASES AND ESTIMATED TIME FRAMES. 14. THE APPLICANT SHALL PROVIDE A PROVISION ON THE FACE OF THE BINDING SITE PLAT REQUIRING ANY SUBSEQUENT DEVELOPMENT OF THE SITE TO BE IN CONFORMANCE WITH THE APPROVED AND RECORDED BINDING SITE PLAN. 15. THE APPLICANT SHALL PROVIDE A DEDICATION STATEMENT AND ACKNOWLEDGEMENT ON THE FACE OF THE BINDING SITE PLAN FOR ALL REQUIRED DEDICATIONS DESCRIBED IN THE ABOVE CONDITIONS OF APPROVAL. 18215 72ND AVENUE SOUTH SAQ_R �F W A Sy/ KENT, WA 98032 (425)251 6222 (425)251 8782 FAX F pF�/ S6 E `% 2 REVISED PER AS —BUILT CONDITIONS CIVIL ENGINEERING, LAND PLANNING, l 0L ECG\ Di CP-03 SURVEYING, ENVIRONMENTAL SERVICES 10/28/20 NO. REVISION ZTW 0/28/2q ZTW ZTW 4/2/18 1 ZTW iFly—Mm - i a SURVEYED: DESIGNED: ZTW DRAWN: CHECKED: APPROVED: AS SCALE: N/A ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM CITY OF R E N T 0 N Planning/Building/Public Works Dept. CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORDING DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY BARGHAUSEN CONSULTING ENGINEERS, INC AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEYED INFORMATION AND DOCUMENTED FIELD REVISIONS. R-396402 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LAND USE CONDITIONS UW MEDICINE - VALLEY MEDICAL CENTER MEDICAL OFFICE BUILDING EXPANSION 400 SOUTH 43RD STREET RENTON, WASHINGTON 98055 DATE: 12/29/2017 FIELDBOOK: PAGE C1.1 28 00 N S U N LO 0 FD I C.�