HomeMy WebLinkAboutR-396404d"
O
O
M
O
d'I
I
A
W
C�
I
I
I
X
J
w
z
0
a
V
0
Q
0
N
0
N
\
Co
N
0
E
cn
E
I
W
I
N
0)
0
Do
m
O
/
X
w
m
0
/
N
0
O
0
O
00
' 1WallI 0 • •- • • �•
I mmvfi
t
i • ' i,
1 . 1 •.r `' `h,�r-.� ICI
T.E.S.C. LEGEND
DESCRIPTION PROPOSED
TEMPORARY SILT FENCE
TEMPORARY CONSTRUCTION ENTRANCE o 0 0 0 0 0
0 0 0 0 0 0
LIMITS OF CLEARING ,
CATCH BASIN PROTECTION
ROCK CHECK DAM
FLOW ARROW
TEMPORARY DRAINAGE DITCH �•••�•••
INSTALL BAKER TANKS I I / / I %� \ / , �� CESCL-
/ AND FILTRATION SYSTEM \
LOCATION TO BE COORDINATED I ( WALTER HOLBROOK
/ // / CLEARING ' / DURING CONSTRUCTION ' / / / 1\ , Tlt RY C ENTRANCE L
' / l i � � / f R Qj�RSTD. P �I 1 1 � / /
/ LIMITS (TYP.) / / I —�0 NEESER CONSTRUCTION INC.
TH//�uHEEL H F AS REQUIRED
�L� H - / 206-294-1817
CLEAR N / �\ / / / NPDES PERMIT NO:
� \ , LIMIT ,� � \ � � /
ING % /, / 4�/ \ \ / / WAR 3 0 612 3
F�'97.25
/ TEMPORARY 1970.59 SF
/ f SEDIMENT TRAP PER COR STD.(2)
PLAN 211.00
DETAIL PER SHEET C4
\ '
\
/INSTALL INTERCEPTOR DITCH W/
y / ROCK CHECK DAMS PER COR
STD. PLAN 217.10 AND 217.40
DETAIL PER SHEET C4
INSTALL INTERCEPTOR DITCH W/
ROCK CHECK DAMS PER COR
STD. PLAN 217.10 AND 217.4
/ DETAIL PER SHEET C4
F�AJND
p li
BAKER TANK NOTES
1) REQUIRED STORAGE = 77,878 GALLONS
/\ I OTECTI PER R 2) 4-8 x 46 TANKS (20,000 GALLONS EACH) FOR
CB PROTECTION PER COR / \ �� \� \ `\ J \ \ / w p / 0 ( ) C
— i / STORAGE
STD. PLAN 216.30 (TYP.) / \ \ I �� ��`�\\ J \i \ \ 1 / IL P SF�E \ \ / \ 3) 2-8' x 46' TANKS (20,000 GALLONS EACH) FOR
DETAIL PER SHEET C4 / \ \ I l �\ \\\ \ J \ \ I i w / TREATMENT
\�
NOTE -
CONTRACTOR TO SEQUENCE PROJECT T.E.S.C.
\ O
MEASURES TO ENSURE THAT ACCESS WILL BE
MAINTAINED TO THE EXISTING BUILDING TO THE WEST.
QI-G'Hq(j0 18215 72ND AVENUE SOUTH
m� �2 KENT, WA 98032
(425)251-6222
o (425)251-8782 FAX
�Q.`' CIVIL ENGINEERING, LAND PLANNING,
�HG ENG�N� SURVEYING, ENVIRONMENTAL SERVICES
CC
O
N
S
t`
U
0
0
FD
c.6
04
PO
x
IN COMPLIANCE WITH CITY OF RENTON STANDARDS W
o,
�l/
�-� S �F WAS
y/
,P • O
24661
o�FSS 01STE��G���`�
AL
10/28/20
2 REVISED PER AS —BUILT CONDITIONS
A CP-03
NO. REVISION
SURVEYED:
DESIGNED:
ZTW
ZTW 0/28/2 ZTW DRAWN: ZTW
ZTW 4 2 18 ZTW CHECKED:
AS
BY DATE APPR APPROVED:
AS
SCALE:VER`n_
1"=30' HORIZONTAL- ONTAL- N D 1983/1991 CITY OF
RENTON
ONE INCH DATUM vAs•
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
R-396404
T.E.S.C. PLAN
UW MEDICINE - VALLEY MEDICAL CENTER
MEDICAL OFFICE BUILDING EXPANSION
400 SOUTH 43RD STREET
RENTON, WASHINGTON 98055
W
U
W
A
DATE:
12/29/2017
FIELDBOOK:
PAGE:
W
DRAWING NO:
SHEET: OF:
C3 28