SITE SPECIFIC DATA
PROJECT NAME
4249 - VMC MEDICAL OFFICE
BUILDING
PROJECT LOCATON
RENTON, WA
STRUCTURE ID
/I
TREATMENT REQUIRED
VOLUME BASED (CF)
2-YEAR RELEASE RATE (CFS)
0.0499
TREATMENT HGL AVAILABLE (FT)
N/A
PEAK BYPASS REQUIRED (CFS) - IF APPLICABLE
0.33
PIPE DATA
I E.
MATERIAL
DIAMETER
INLET PIPES
69,73
CPEP
12"
OUTLET PIPE
69.23
CPEP
12"
PRETREATMENT
BIORLTRATION
DISCHARGE
RIM ELEVATION
79.42
79.42
79.42
SURFACE LOAD
PARKWAY
PARKWAY
PARKWAY
FRAME & COVER
030"
030"
N/A
WETLANDMEDIA VOLUME (CY)
1.60
WETLANDMEDIA DELIVERY METHOD
PER CONTRACT
ORIFICE SIZE (DIA. INCHES)
01,09"
NOTES
CONSTRUCTION NOTES AND DETAILS
FOR
UW MEDICINE -VALLEY MEDICAL CENTER
MEDICAL OFFICE BUILDING EXPANSION
SITE CURBING
BY OTHERS
C/L
DRAIN DOWN UN£ 1'-2"
INLET PIPE
INTERNAL BYPASS DISCLOSURE:
VERTICAL
UNDERDRA/N
I
SEE NOTES
THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED
MANIFOLD'.
PR£ -FILTER
AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE
=': ?
CARTRIDGE
ASSESSED TO ENSURE NO UPSTREAM FLOODING PEAK HGL AND BYPASS
CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY.
LOW INFLOW PIPE DISCLOSURE:
71ANDMEDIA
I
OUTLET PIPE
IT IS RECOMMENDED THAT A SUFFICIENT VARIATION IN ELEVATION BETWEEN THE
BED
SEE NOTES
INLET AND OUTLET BE PROVIDED TO ALLOW FOR ACCUMULATION OF SEDIMENT IN
THE PRE-TREATMENT CHAMBER. FAILURE TO DO SO MAY RESULT IN BLOCKAGE
PATENTED
1'-2
AT INFLOW POINTS) WHICH MAY CAUSE UPSTREAM FLOODING.
PERIMETER
PLAN VIEW
VOID AREA
0 �
I
INSTALLATION NOTES
1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT MATERIALS AND
INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND
APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE
MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN
MANUFACTURERS CONTRACT
2. UNIT MUST BE INSTALLED ON LEVEL BASE MANUFACTURER
no,
RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY
THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE TO VERIFY_
PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATONS
J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE.
(PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE
5"
6'-4"
5"
MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL CAPS
T_2"
AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON -SHRINK
GROUT PER MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL
ELEVATION VIEW
MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS.
4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING
PIPES.
5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS,
MANHOLES, AND HATCHES CONTRACTOR TO GROUT ALL MANHOLES AND
HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE.
6, DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION.
GENERAL NOTES
1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED.
2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO
CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS
AND ACCESSORIES PLEASE CONTACT MANUFACTURER.
SITE SPECIFIC DATA
PROJECT NAME
4249 - VMC MEDICAL OFFICE
BUILDING
PROJECT LOCATION
RENTON, WA
STRUCTURE ID
12
TREATMENT REQUIRED
VOLUME BASED (CF)
2-YEAR RELEASE RATE (CFS)
0.02
TREATMENT HGL AVAILABLE (FT)
N/A
PEAK BYPASS REQUIRED (CFS) - 1F APPLICABLE
0.066
PIPE DATA
LE.
MATERIAL
DIAMETER
INLET PIPES
87.10
CPEP
12"
OUTLET PIPE
86.60
CPEP
12"
PRETREATMENT
BIDFILTRATION
DISCHARGE
RIM ELEVATION
98.17
98.17
98.17
SURFACE LOAD
PARKWAY
PARKWAY
PARKWAY
FRAME & COVER
030"
030"
N/A
WETLANOMEOM VOLUME (Cy)
1.60
WETLANDMEDIA DELIVERY METHOD
PER CONTRACT
ORIFICE SIZE (DIA. INCHES)
00.71 "
NOTES:
SIIE CURBING
BY OTHERS
rUPRYPE
PR£-RTL MR
CARTRIOG£
OUTLET PIPE
S££ NOTES
INSTALLATION NOTES
1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT MATERIALS AND
INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND
APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE
MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN
MANUFACTURERS CONTRACT
2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER
RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY
THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE TO VERIFY
PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATIONS.
J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE.
(PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE
MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL CAPS
AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON -SHRINK
GROUT PER MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL
MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS.
4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING
PIPES,
5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS,
MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND
HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE.
6. DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION.
GENERAL NOTES
1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED.
2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO
CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS
AND ACCESSORIES PLEASE CONTACT MANUFACTURER.
-�Hq�s 18215 72ND AVENUE SOUTH
m� �Z KENT, WA 98032
(425)251-6222
o (425)251-8782 FAX
Zl
CIVIL ENGINEERING, LAND PLANNING,
/Iy0 ENGXN� SURVEYING, ENVIRONMENTAL SERVICES
EA
9ANN0IE 79.42
"Q'L GRAD£ RINGS
C, IL
� 78.86
I
TOP OF VAULT
F1 F1
78.02
I �
I
I
o
NPEAK
O
ao
HGL
F
-�---
fLOW 71.92
RISER
E OUT 69.73
69.23
1
5"4'-0"5"
RIGHT END VIEW
4 -10"
LEFT END VIEW
D241N DOWN LINE
INTERNAL BYPASS DISCLOSURE:
THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED
AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE
ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS
CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY.
LOW INFLOW PIPE DISCLOSURE:
UNDEROR4/N
r MANIFOLD
IT IS RECOMMENDED THAT A SUFFICIENT VARIATION IN ELEVATION BETWEEN TH£
',:;'=' �4_
INLET AND OUTLET BE PROVIDED TO ALLOW FOR ACCUMULATION OF SEDIMENT IN
THE PRE-TREATMENT CHAMBER. FAILURE TO DO SO MAY RESULT IN BLOCKAGE
. -... YQ7/ AA/AIAClVA
AT INFLOW POINT(S) WHICH MAY CAUSE UPSTREAM FLOODING.
U� `+'1
BED
PATENTED
PLAN VIEW
PERIMETER
VOID AREA
c/L
aIa
5.'I �6'I4•�+5.
��IIII
ELEVATION VIEW
L� SAOR
,7 �E W A Sys
24661 �
o�`�sSTE ��G\���
AL
10/28/20
6"- MZy. BASE
5' �� 4'-0" _5"
4'- f0"
dl
RIGHT END VIEW
MANHOLE
98,17 C/L
:::::-
WE RINGS
97.56
OF VA Ut T
95.39
a i
00
F" Hot
88.92 ROW
coffma
R13£R
if IN
87.10 IE OUT
0o i� 86.60
LEFT END VIEW }
2 REVISED PER AS -BUILT CONDITIONS
CP-03
NO. REVISION
FRAME AND LADDER OR STEPS
OFFSET.
RIM= 86.00
MARKED "DRAIN"
WITH LOCKING BOLTS
SEE KCRS DWG'S 49 & 50
8" DIA. CLEANOUT
SHEAR GATE PER DETAIL
NOTES
INVERT
EL=62.75
b PIPE SUPPORTS
3" x .090 GAGE BOLTED
OR EMBEDDED 2" IN WALL
AT MAXIMUM 3' SPACING.
MINIMUM ONE SUPPORT
a a MIN.
a`
12" OUTLET
FRAME AND LADDER OR STEPS
OFFSET.
RIM= 80.63
MARKED "DRAIN"
WITH LOCKING BOLTS
SEE KCRS DWG'S 49 & 50
8" DIA. CLEANOUT
SHEAR GATE PER DETAIL
NOTES
EL=63.12
O
d o
O d
a
d
O d.
d 4.
SDMH #6 DETAIL
NOT TO SCALE
a
d
18" OUTLET
SURVEYED:
DESIGNED:
ZTW
ZTW 10/28/2C ZTW DRAWN: ZTW
ZTW 4 2 18 ZTW cHECKEO
AS
BY DATE APPR APPROVED:
AS
CB #8 DETAIL
NOT TO SCALE
12" INLET
PIPE
INVERT
EL=74.8
RISER SHALL EXTEND
TO THE TOP OF THE
12" OUTLET PIPE.
PIPE SUPPORTS
3" x .090 GAGE BOLTED
OR EMBEDDED 2" IN WALL
AT MAXIMUM 3' SPACING.
18" ]-MIN-
MINIMUM ONE SUPPORT
6
INVERT
EL=68.75
RISER SHALL EXTEND
TO THE TOP OF THE
18" OUTLET PIPE.
CONSMC'nON RECORD
DRAWING
THIS CONSTRUCTION RECORDING DRAWING IS A
COPY OF THE APPROVED CONSTRUCTION
DRAWINGS PREPARED BY BARGHAUSEN
CONSULTING ENGINEERS, INC AND HAS BEEN
EDITED TO REFLECT ASBUILT CONDITIONS. THE
INFORMATION PROVIDED ON THESE RECORD
DRAWINGS IS A COMBINATION OF FIELD
SURVEYED INFORMATION AND DOCUMENTED
FIELD REVISIONS.
NOTES:
1. PIPE SIZES & SLOPES: SEE PLANS.
2. METAL PARTS:
A) CORROSION RESISTANT OR GALVANIZED OR ALUMINIZED TYPE II
B) IF GALVANIZED STEEL PIPE, HAVE ASPHALT TREATMENT I
4. FRAME & LADDER OR STEPS OFFSET SO:
A) CLEANOUT GATE IS VISIBLE FROM TOP
B) CLIMBDOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE.
C) FRAME IS CLEAR OF CURB
CALE: __
N/A HORIZONTAL• HAD 1983/1991 CITY OF
[;%Rl RENTON
ONE INCH DATUM '
AT FULL scALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
N
0
S
F^il
F+I
NOTES:
1. PIPE SIZES & SLOPES: SEE PLANS.
2. METAL PARTS:
A) CORROSION RESISTANT OR GALVANIZED OR ALUMINIZED TYPE II
B) IF GALVANIZED STEEL PIPE, HAVE ASPHALT TREATMENT I
4. FRAME & LADDER OR STEPS OFFSET SO:
A) CLEANOUT GATE IS VISIBLE FROM TOP
B) CLIMBDOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE.
C) FRAME IS CLEAR OF CURB
R-396420
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
W
U
r�
M
Q
DATE,
CONSTRUCTION NOTES AND DETAILS 2/29/201 7
O
UW MEDICINE - VALLEY MEDICAL CENTER FlELDBOK:
PAGE W
MEDICAL OFFICE BUILDING EXPANSION DRAvnNGNO:
400 SOUTH 43RD STREET 04
RENTON, WA 98055 SHEET: OF:
C23 28