P"O"G`" © ADDITIONAL IRRIGATION EQUIPMENT, CONSISTS OF:
WILKINS 950 XLT- 1•• DOUBLE CHECK VALVE (STATE APPROVED); TEST AND CERTIFICATION
BY LICENSED BACKFLOW TESTER
WILKINS 850 - BALL VALVE, SIZE TO MATCH PIPE
LOCATE DCVA IN WATER ROOM ON NORTH SIDE OF MEDICAL OFFICE FACILITY
ADJACENT TO TRASH AREA. COORDINATE LOCATION WITH GENERAL CONTRACTOR AND PLUMBER
- - - - - - - - - - - - - MAINLINE - SCH 40 PVC (18•• COVER); SIZE PER PLAN, 1-1/2•• SIZE MINIMUM
LATERAL - SCH 40 PVC (12" COVER); SIZE PER PLAN, 3/4" SIZE MINIMUM
SLEEVE
LANDSCAPE
and IRRIGATION PLAN
PVC; 24" MINIMUM
COVER AT VEHICLE
CROSSINGS, TWICE THE
SIZE OF
INSERT
FOR
��
SIZE MINIMUM
23
23.1-32
UW MEDICINE - VALLEY MEDICAL CENTER
a
GPM (MAX.)
MEDICAL
OFFICE BUILDING EXPANSION
STATE OF
WASHINGTON
(0
REGISTERED
O
LANDSCAGE �R�HITECT
co
\\�1A�����V��
N
O
IRRIGATION LEGEND
JEFF M. Y
VARLE
CERTIFICATE "° "`
U
SYMBOL
DRIP EMITTER
HUNTER LANDSCAPE DRIPLINE COMPONENTS WITH HUNTER BARBED FITTINGS AND ADAPTERS
O
ICZ-101-LF WITH 40 PSI PRESSURE REGULATOR
PLD -04-18 DRIP EMITTER TUBING 0.40 GALLONS PER HOUR FLOW, EMITTERS 18•• O.C.
AIR/VACUUM RELIEF RELIEF VALVE KIT, IN VALVE BOX
GALVANIZED TIE -DOWN STAKES, AT 3' ON CENTER
PLUS HUNTER IH -12 -60 -CV TREE -IRRIGATING RISERS, WITH HEB-60 POINT SOURCE EMITTER
INCLUDED
00
2 PER TREE, LOCATED ON OPPOSITE SIDES OF THE ROOTBALL. CONNECT RISERS TO DRIPLINE
ON SAME VALVE.
m
O
0
0
co
Q
SYMBOL
MANUFACTURER
DRIP IRRIGATION:
®
HUNTER ICZ-101-LF VALVE
ONE VALVE PER BOX
HUNTER WSS-SEN WIRELESS SOLAR SYNC. INSTALL ON SOUTH SIDE OF BUILDING
EXPOSED TO WEATHER. COORDINATE RAIN SENSOR LOCATION WITH ARCHITECT.
N
O
HUNTER PRO -C 12 -STATION (HARDWIRE CONNECTION); PROVIDE GROUND AND BATTERIES
0
PER MFR. SPECS. LOCATE IN SAME ROOM AS WATER METER AND DCVA. COORDINATE LOCATION
WITH
o
GENERAL CONTRACTOR, AND ELECTRICIAN
p
Q
HUNTER 3/4" QUICK COUPLING VALVE, IN VALVE BOX, WITH (2) KEYS AND SWIVELS
(fl
IY
PLASTIC BALL VALVE, MATCH LINE SIZE, IN VALVE BOX
0 -
BRONZE GATE VALVE, MATCH LINE SIZE, IN VALVE BOX
NEW 3/4" WATER METER. SEE CITY OF RENTON STANDARD DETAIL 320-1
P"O"G`" © ADDITIONAL IRRIGATION EQUIPMENT, CONSISTS OF:
WILKINS 950 XLT- 1•• DOUBLE CHECK VALVE (STATE APPROVED); TEST AND CERTIFICATION
BY LICENSED BACKFLOW TESTER
WILKINS 850 - BALL VALVE, SIZE TO MATCH PIPE
LOCATE DCVA IN WATER ROOM ON NORTH SIDE OF MEDICAL OFFICE FACILITY
ADJACENT TO TRASH AREA. COORDINATE LOCATION WITH GENERAL CONTRACTOR AND PLUMBER
- - - - - - - - - - - - - MAINLINE - SCH 40 PVC (18•• COVER); SIZE PER PLAN, 1-1/2•• SIZE MINIMUM
LATERAL - SCH 40 PVC (12" COVER); SIZE PER PLAN, 3/4" SIZE MINIMUM
SLEEVE
- CLASS
200
PVC; 24" MINIMUM
COVER AT VEHICLE
CROSSINGS, TWICE THE
SIZE OF
INSERT
PIPE
AND/OR WIRES, 4•'
SIZE MINIMUM
23
IRRIGATION SHOWN DIAGRAMATICALLY FOR PLAN CLARITY. COMMON TRENCH AND PLACE EQUIPMENT
IN LANDSCAPE; MANIFOLD GROUPED VALVES IN ADJACENT SHRUB AREAS WHERE FEASIBLE.
ALL IRRIGATION CONNECTIONS AND FITTINGS SHALL BE LEAD-FREE
SCH 40 PIPE SIZING CHART
PIPE SIZE
1 3/4"
1 1"
11 1/4"
11 1 2"
1 2"
2 1/2 -
2"FLOW
FLOW
GPM
1 1-8
8.1-13113.11
23
23.1-32
32.1-53
53.1-74
GPM (MAX.)
No.
R-3964-30
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
close 01/22/2018
1"=30''V'8"IRRIGATION PLAN - IRRIG. SCHEDULE
CITY OF UW MEDICINE - VALLEY MEDICAL CENTER
" REN TON
" znv ,K,a MEDICAL OFFICE BUILDING EXPANSION
ero,� 5 �. w I DATUM Plannmy�euBdmg/Pub�Pc wows Dept. 400 SOUTH 43RD STREET
aevsoN ev DATC All. we AS RENTON, WASHINGTON 98055