HomeMy WebLinkAboutPRE24-000010_8225 S 132nd St_Single Family Residence_PlanningSummary_FINAL
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: February 15, 2024
TO: Pre-Application File No. 24-000010
FROM: Brianna Burroughs, Associate Planner
SUBJECT: VEK SFR – 8225 S 132nd ST (Parcel number 2144800535)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, and City Council). Review comments may also need to be
revised based on site planning and other design changes required by City staff or made by the
applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal
Code. The Development Regulations are available online at
https://www.codepublishing.com/WA/Renton/.
Project Proposal:
Location: 8225 S 132nd ST (Parcel number 2144800535)
Zone: Residential 14 (R-14)
Proposal: SFR & ADU- build one (1) single family residence and one
(1) Accessory Dwelling Unit on vacant property.
Lot Square Footage: Exist: 26,483 SF
Current Lot Type: Internal lot
Site Access: Primary access from S 132nd ST
Current Use: Vacant Lot
Proposed Primary Structure Square
Footage:
3,975 SF
Critical Areas: regulated slopes (>15% & <=90%) and an unnamed non-
fish bearing seasonal stream (Type Ns)
1. Zoning/Land Use: The subject property is located within the Residential-14 (R-14) zoning
classification. The Residential-14 Zone (R-14) is established for high-density residential
development that will provide a mix of residential styles including small lot detached
dwellings or attached dwellings such as townhouses and small-scale flats. Development
VEK SFR PRE24-000010
Page 2 of 10
February 15, 2024
promoted in the zone is intended to increase opportunities for detached dwellings as a
percent of the housing stock, as well as allow some small-scale attached housing choices
and to create high-quality infill development that increases density while maintaining the
single family character of the existing neighborhood.
Detached dwellings and detached accessory dwelling units (DADU’s) are permitted uses
within the R-14 zone.
2. Development Standards: The project would be subject to RMC 4-2-110A, Development
Standards for Residential Zoning Designations effective at the time of complete
application (noted as “R-14 standards” herein).
Density: The density range allowed in the R-14 zone is a minimum of seven (7) dwelling
units with a maximum of 14 dwelling units per net acre. The area of public rights-of-way,
legally recorded private access easements and critical areas (i.e. very high landslide
hazard areas, protected slopes, wetlands, Class 1 to 4 streams and lakes or floodways)
would be deducted from the gross site area to determine the “net” site area prior to
calculating density. In order to calculate the proposed density of the project, any area of
public road, private driveway/easement, and/or critical area dedication must be known.
All fractions which result from net density calculations shall be truncated at two (2)
numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for minimum or
maximum density that result in a fraction that is 0.50 or greater shall be rounded up to
the nearest whole number. Those density calculations resulting in a fraction that is less
than 0.50 shall be rounded down to the nearest whole number. The R-8 zone has a
minimum density of four (4) dwelling units per acre with a maximum of eight (8) dwelling
units per acre.
Minimum Units per acre 7 Units
Maximum Units per acre 14 units
Current lot size in acres 0.60 acres
Proposed lots 1
Gross density 1.64 du/ac
The applicant would be required to demonstrate compliance with the net density
requirements of the zone at the time of formal application.
The proposal to build one detached dwelling unit and one detached accessory dwelling
unit currently does not meet the minimum density standards of this section. Please be
advised, this calculation will change following any dedication of frontage to
accommodate street improvements as well as any other proposed easements (such as
Native Growth protection Easements) or tracts. A density worksheet deducting street
improvements, private easements and critical areas will be required to be submitted
with the building permit application in order to demonstrate that the minimum density
requirements cannot be met. See RMC 4-2-110E.1.b for more details on submittal
requirements.
VEK SFR PRE24-000010
Page 3 of 10
February 15, 2024
Minimum Lot Size, Width and Depth –
Minimum lot size 3,000 SF
Minimum Lot width 30 FT
Minimum Lot width for Corner lots 40 FT
Minimum Lot Depth 60 FT
In order to ensure compliance with Tier 1 requirements for Tree Preservation Priority,
pursuant to RMC 4-4-130H2a, lot size and lot dimensions of the zone may be decreased
by a maximum of 10 percent (10%), provided the applicant can demonstrate to the
Administrator’s satisfaction that the reduction is necessary to ensure the preservation of
all significant trees, as defined in RMC 4-11-200, required for retention within dedicated
tract(s), pursuant to RMC 4-4-130H1a, Minimum Tree Retention Requirements.
The proposal does not intend to subdivide the lot. Compliance with minimum lot size,
width and depth standards will be verified at the time of land use application.
Building Standards –
Building Coverage: 65%
Impervious Surface Coverage: 80%
Building Height: 24 ft., increase up to 32 ft. possible subject to
administrative conditional use permit
approval.
Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical
feet from the maximum wall plate height; common rooftop features, such as chimneys,
may project an additional four vertical feet (4’) from the roof surface. Non-exempt vertical
projections (e.g., decks, railings, etc.) shall not extend above the maximum wall plate
height unless the projection is stepped back one-and-a-half horizontal feet (1.5’) from
each façade for each one vertical foot (1’) above the maximum wall plate height. The
maximum wall plate height for detached accessory structures is 12 feet (12’) and the total
floor area must be less than that of the primary structure. Accessory structures are also
included in building lot coverage calculations.
The site plan provided a building coverage percentage of 19% and an impervious surface
coverage percentage of 36%. These numbers are meeting the code standard maximums
for the zone. No building elevations were provided. The site plan indicates that the
building height may be 32 FT but there was no indication in the narrative that the
applicant is seeking an administrative conditional use permit for the extra height. An
Administrative CUP is a Type II permit process which consists of a public notice posting,
public comment period, and staff decision approval. If the applicant is interested in this
process please see the Conditional Use Permit Submittal Requirements for more details.
VEK SFR PRE24-000010
Page 4 of 10
February 15, 2024
Setbacks and lot type –
Front Yard Setback: 15 FT 10 FT when access is taken from the
alley
Secondary Front Yard Setback: 15FT
Side Yard Setback: 4FT 4 ft. for unattached side(s), 0 ft. for
the attached side(s)
Rear Yard Setback: 10 FT
Building Separation: 4FT- A proposed ADU must be four feet (4’)
from any residential structure. (Anything
closer would be considered attached, and
attached ADU’s are not permitted).
Lot Type:
The parcel is considered an interior lot and the site plan provided appears to meet
setbacks for the zone. Compliance with required setbacks and building orientation for
new development would be verified at the time of building permit application.
3. Residential Design and Open Space Standards: All new primary dwelling units within the
R-14 zone are required to meet applicable standards within RMC 4-2-115 Residential
Design and Open Space Standards. In addition, any retained dwelling units included in the
development must also comply with these standards. The standards of the Site Design
subsection are required to be addressed at the time of subdivision application. When new
dwelling units are created in the R-14 zone any retained dwelling units included in the
development shall comply with the standards of this section.
No building elevations have been provided for the Single Family Residence or the ADU.
Please also see the ADU pre-application comments for design standards for the ADU.
VEK SFR PRE24-000010
Page 5 of 10
February 15, 2024
Compliance with building design requirements would be verified at the time of building
permit application.
4. Access/Parking: See RMC 4-4-080 for complete Access and Parking standards.
Setbacks from property line: Driveways shall not be closer than five feet (5') to any property
line.
The maximum width of single loaded garage driveways shall not exceed nine feet (9') and
double loaded garage driveways shall not exceed sixteen feet (16'). If a garage is not
present on the subject property the maximum width of a driveway shall be sixteen feet
(16').
There shall be no more than one driveway for each one hundred sixty five feet (165') of
street frontage serving any one property or among properties under unified ownership
or control; for each one hundred sixty five feet (165') of additional street frontage another
driveway may be permitted subject to the other requirements.
Maximum driveway slopes shall not exceed fifteen percent (15%); provided, that
driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with
positive drainage discharge to restrict runoff from entering the garage/residence entering
public or private streets, alleys, sidewalks, and/or pedestrian pathways. To exceed fifteen
percent (15%), a variance from the Administrator is required.
Driveways and driveway approaches in the public right-of-way shall be paved with
asphaltic concrete, cement, or equivalent alternative materials of a permanent nature as
approved by the Public Works Department. Surfacing treatments that provide increased
infiltration opportunities, such as permeable pavements, shall be used where feasible and
consistent with the Surface Water Design Manual.
Parking Spaces Required- Single Family: A minimum of 2.0 per dwelling unit, however, 1.0
per dwelling unit may be permitted for 1 bedroom or less dwelling units. Tandem parking
is allowed. In addition, if the primary structure on a site where an accessory dwelling unit
(ADU) is proposed does not meet the City’s minimum parking standards, 1.0 additional
off-street parking space is required to obtain approval.
The site plan provided shows one driveway approach off S 132nd ST, aligned with
Earlington Village intersection. The driveway is setback 5 feet from the property line,
the width is 16 FT, and the material is asphalt. The current proposed site plan appears
to be meeting access and parking standards. The driveway slope is not stated.
Compliance with driveway standards would be verified at the time of building permit
review.
5. Landscaping: See RMC 4-4-070 for Landscaping Standards.
Street Frontage Landscaping Required: Ten feet (10') of on-site landscaping is required
along all public street frontages, with the exception of areas for required walkways and
driveways and those zones with building setbacks less than ten feet (10'). In those cases,
ten feet (10') of landscaping shall be required where buildings are not located. The
landscape strip shall contain a mixture of trees, shrubs, and groundcover.
Street Trees and Landscaping Required Within the Right-of-Way on Public Streets:
Minimum planting strip widths between the curb and sidewalk are established according
to the street development standards of RMC 4-6-060. Street trees and, at a minimum,
VEK SFR PRE24-000010
Page 6 of 10
February 15, 2024
groundcover per subsection L2 of RMC 4-4-070 shall be planted within planting strips
pursuant to the following standards, provided there shall be a minimum of one street tree
planted per lot. See RMC 4-4-070.F.2.a-c for details on street tree and landscape
standards. Street trees shall be planted in the center of the planting strip between the
curb and the sidewalk at the following intervals; provided, that, where right-of-way is
constrained, irregular intervals and slight increases or decreases may be permitted or
required.
Pervious Areas to Be Landscaped: With the exception of critical areas, all portions of the
development area not covered by structures, required parking, access, circulation or
service areas, must be landscaped with native, drought-resistant vegetative cover.
Landscaping may also include hardscape such as decorative paving, rock outcroppings,
fountains, plant containers, etc. All of the landscaped area that is not planted with trees
and shrubs or covered with a tree grate must be planted in ground cover plants, which
may include grasses. Mulch must be confined to areas underneath plants and is not a
substitute for ground cover plants.
Tree Planting Locations: Trees shall be planted in locations that meet required spacing
distances from facilities located in the right-of-way including, but not limited to,
underground utilities, streetlights, utility poles, traffic signs, fire hydrants, and driveways;
such spacing standards are identified in the City’s Approved Tree List. Generally, the
following spacing is required: i. Small-sized maturing trees: thirty feet (30') on center; ii.
Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized maturing
trees: fifty feet (50') on center.
A conceptual landscape plan shall be provided with the Building Application as prepared
by a licensed Landscape Architect, a certified nurseryman or other certified professional.
Please be aware that frontage improvements will be required.
6. Significant Tree Retention: When significant trees (greater than 6-inch caliper or 8-
caliper inches for alders and cottonwoods) are proposed to be removed, a tree inventory
and a tree retention plan along with an arborist report, tree retention plan and tree
retention worksheet shall be provided with the formal land use application as defined in
RMC 4-8-120. The tree retention plan must show preservation of at least 30% of
significant trees. Please refer to RMC 4-4-130, Tree Retention and Land Clearing
Regulations for further general and specific tree retention and land clearing
requirements.
In addition to retaining a minimum of 30% of existing significant trees, each new lot would
be required to provide a minimum tree density of 30 tree credits per net acre. Tree credits
encourage retention of existing significant trees with larger trees being worth more tree
credits.
TREE SIZE TREE CREDITS
New small species tree 0.25
New medium species tree 1
New large species tree 2
VEK SFR PRE24-000010
Page 7 of 10
February 15, 2024
TREE SIZE TREE CREDITS
Preserved tree 6 – 9 caliper inches 4
Preserved tree 10 – 12 caliper inches 5
Preserved tree 12 – 15 caliper inches 6
Preserved tree 16 – 18 caliper inches 7
Preserved tree 19 – 21 caliper inches 8
Preserved tree 22 – 24 caliper inches 9
Preserved tree 25 – 28 caliper inches 10
Preserved tree 29 – 32 caliper inches 11
Preserved tree 33 – 36 caliper inches 12
Preserved tree 37 caliper inches and greater 13
Protected trees shall be retained in the order of priority listed in RMC 4-4-130H.2. Protection
of trees or groves by placement within a dedicated tract (Tier 1) is the highest priority.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees
on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and
their associated buffers; significant trees over sixty feet (60') in height or greater than
eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting
properties from strong winds, which could otherwise allow such sheltered trees to be blown
down if removed.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical area or
its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City's discretion.
The Administrator may authorize the planting of replacement trees on the site if it can be
demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4-
130H.1.e can be met.
Tree retention standards shall be applied to the developable area, as defined in RMC 4-11-
040, Definitions D, of a property. A formal tree retention plan and tree retention worksheet
prepared by an arborist or landscape architect would be reviewed at the time of the land
use application.
VEK SFR PRE24-000010
Page 8 of 10
February 15, 2024
7. Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this
project, the location must be designated on the landscape plan and grading plan with top of
wall and bottom of wall elevations. A fence and/or wall detail should also be included on the
plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the
bottom of the footing to the finish grade at the top of the wall requires a building permit. The
maximum height of any fence or retaining wall is 72-inches subject to further height
limitations in setbacks and clear vision areas noted in RMC 4-4-040D. A fence shall not be
constructed on top of a retaining wall unless the total combined height of the retaining wall
and the fence does not exceed the allowed height of a standalone fence. For more
information about fences and retaining walls refer to RMC 4-4-040.
8. Critical Areas: According to COR Maps, there are regulated slopes (>15% & <=90%) and an
unnamed non-fish bearing seasonal stream (Type Ns) on the site.
Geologically hazardous areas are present on the site. Whenever a proposed development
requires a development permit and a geologic hazard is present on the site of the proposed
development geotechnical studies by licensed professionals, such as a geotechnical
engineer and/or engineering geologist, are required.
The required study shall demonstrate the following review criteria can be met: (a) The
proposal will not increase the threat of the geological hazard to adjacent or abutting
properties beyond pre-development conditions; and (b) The proposal will not adversely
impact other critical areas; and (c) The development can be safely accommodated on the site.
The geotechnical study must meet the requirements set forth in the City of Renton Critical
Areas Regulations, RMC 4-3-050. Per RMC 4-3-050 the City may require an independent
secondary review of any valid geotechnical reports by a qualified specialists selected by the
City, at the applicant’s expense. Based upon the results of a geotechnical report and/or
independent review, conditions of approval for developments may include increased buffers
and/or increased setbacks from buffers. Buffers are established from the top, toe, and sides
of slopes. Alterations to critical areas buffers is subject to RMC 4-3-050I. Protected slopes also
require a 15-foot building setback beyond the required buffer.
Type Ns streams require a minimum buffer of 50 feet with an additional structure setback
from the buffer of 15 feet.
Alterations to stream buffers may be permitted in the case of degraded stream buffer width
with enhancement or an averaged stream buffer width per RMC 4-3-050I.
Please note a stream study, prepared by a qualified biologist, would need to verify the
classification and delineation of the stream. The city does not have a biologist on staff and
may send out the stream study to a secondary reviewer with all costs to be paid by the
applicant.
A stream study is required because of the presence of the Type NS stream located on the lot.
Streams and their associated buffers and protected slopes and their associated buffers are
required to be protected from any proposed development activity via a native growth
protection area. The most common method is to create a tract and record a permanent and
irrevocable covenant running with the land or deed restriction on the property title of any
critical area management tract or tracts created as a condition of a permit. It is the
applicant’s responsibility to determine whether any other critical areas are present on the
site prior to formal land use application.
VEK SFR PRE24-000010
Page 9 of 10
February 15, 2024
9. Environmental Review: The proposed project would be subject to Washington State
Environmental Policy Act (SEPA) due to the presence of critical areas onsite. Therefore, an
environmental checklist is a submittal requirement. An environmental determination will be
made by the Renton Environmental Review Committee.
10. Site Plan Approval: Per RMC 4-9-200, site plan review is required for any development in the
R-14 zone. The purpose of the site plan review process is to analyze the detailed arrangement
of project elements to mitigate negative impacts where necessary to ensure project
compatibility with the physical characteristics of a site and with the surrounding are. Site plan
review ensures quality development consistent with the City goals and policies. Site Plan
review analyzes elements including, but not limited to, site layout, building orientation and
design, pedestrian and vehicular environment, landscaping, natural features of the site,
screening and buffering, parking and loading facilities, and illumination to ensure
compatibility with the potential future development. Decision criteria for site plan approval
are itemized in RMC 4-9-200E.3.
11. Permit Requirements: The proposal would require administrative site plan review and
Environmental (SEPA) Review. The application would be reviewed within an estimated time
frame of 6-8 weeks. The 2024 fees would total $5,071.50 ($3,030.00 Admin. Site Plan Review
+ $1,800.00 Environmental Review + $241.50 Technology Fee (5%) = $5,071.50). Each
modification request is $290.00. A 5% technology fee added to the total cost of the reviews
would also be assessed at the time of land use application. All fees are subject to change.
Detailed information regarding the land use permit application submittal requirements can
be found on the Site Plan Review checklist. Other informational applications and handouts
can be found on the City’s Digital Records Library.
The City requires electronic plan submittal for all applications. Please refer to the City’s
Electronic File Standards.
12. Public Information Sign: Public Information Signs are required for all Type II Land Use Permits
as classified by RMC 4-8-080, Permit Classification. Public Information Signs are intended to
inform the public of potential land development, specific permits/actions being considered
by the City, and to facilitate timely and effective public participation in the review process.
The applicant must follow the specifications provided in the public information sign handout.
The applicant is solely responsible for the construction, installation, maintenance, removal,
and any costs associated with the sign.
13. Impact Fees: In addition to the applicable building and construction fees, impact fees would
be required. The fee in effect at the time of residential building permit issuance will apply. For
informational purposes, the 2024 impact fees are as follows:
• A Transportation Impact Fee assessed at $11,485.67 per each new Single Family housing
dwelling unit. (No fee for ADU)
• A Parks Impact Fee assessed at $3,276.44 per each new single family housing dwelling
unit. (No fee for ADU)
• A Fire Impact Fee assessed at $421.98per each new single family housing dwelling unit.
(No fee for ADU)
• A Renton School District Impact Fee assessed at $2,161 (plus a 5% administrative fee) per
each new single family housing dwelling unit.(No fee for ADU)
VEK SFR PRE24-000010
Page 10 of 10
February 15, 2024
A handout listing all of the City’s Development related fees is available for your review at
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=0&repo=CityofRe
nton.
14. Next Steps: When the formal land use application materials are complete, the applicant shall
have the application materials pre-screened prior to submitting the complete application
package. Please contact Brianna Burroughs, Associate Planner at bburroughs@rentonwa.gov
or (425) 430-7246 for an appointment.
15. Expiration: Upon approval, the Site Plan Review is valid for two (2) years with a possible one-
year extension (RMC 4-7-070M). It is the responsibility of the owner to monitor the
expiration date.