HomeMy WebLinkAboutPRE_StaffComments_240229_v1DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
|www.rentonwa.gov
PREAPPLICATION MEETING FOR
Kennydale Lakeline Sanitary Sewer
West of Lake Washington Blvd N from 2725 Mountain View Ave N
to 3903 Lake Washington Blvd N
PRE 24-000037
February 29, 2024
Contact Information:
Planner: Andrew Van Gordon, 425.430.7286, avangordon@rentonwa.gov
Public Works Plan Reviewer: Sam A. Morman, 425.430.7383, samorman@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 206.550.8523, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Development Engineering Director, Department of
Community & Economic Development Administrator, Public Works Administrator and
City Council).
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: February 29, 2024
June 20, 2011
TO: Andrew Van Gordon, Associate Planner
FROM: Sam Morman, Civil Engineer II
SUBJECT: Kennydale Lakeline Sanitary Sewer
Mountain View Ave N and Lake Washington Blvd. N
PRE24-000037
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located West of Lake
Washington Blvd N from 2725 Mountain View Ave N to 3903 Lake Washington Blvd N. The following
comments are based on the pre-application submittal made to the City of Renton by the applicant.
WATER
1. The project is within the City of Renton’s water service area however, it does not impact the water
system or water needs of affected properties.
SEWER
2. The project is within the City of Renton’s sanitary sewer service area.
3. There is an existing 8-inch force wastewater main located in Lake Washington.
4. There is an existing 8-inch gravity force main in Lake Washington Blvd. N.
5. This project is proposing to replace the existing side sewers of a number of residences along the
waterfront that are draining to the wastewater main located in Lake Washington, so that they drain
to newly constructed mains in Mountain View Ave N. All new sewer stubs shall conform to the
standards in RMC 4-6-040 and City of Renton Standard Details.
6. For altering/replacing any retaining wall exceeding 4-feet in height (height includes any wall footing
or portion of the wall buried), a separate building permit will be required.
2
7. A public sewer easement will be required over all facilities on private property to be maintained by
the City.
8. Sewer mains shall have a minimum 10-foot horizontal and 1.5-foot vertical clearance between
sanitary and water utilities. Sewer mains shall have a minimum 7-foot horizontal and 1.5-foot
vertical clearance between sanitary and surface water utilities. Clearance is measured from outside
edge to outside edge of pipe. A conceptual utility plan will be required as part of the land use
application for the subject development.
SURFACE WATER
1. Critical areas on site that may affect stormwater review include regulated (steep) slopes, erosion
hazard areas, wellhead protection zones, and landslide areas.
2. Erosion control measures to meet the City requirements shall be provided.
3. Outside of erosion control, there are no expected surface water requirements, as impervious
surface removed for the sole purpose of installing utilizes is not considered replaced.
TRANSPORTATION
1. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay
Requirements.
2. There are no other expected transportation requirements for the scope of work shown in the
submitted documents.
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e., electrical, phone, and cable services, etc.) along
property frontage or within the site must be underground. The construction of these franchise
utilities must be inspected and approved by a City of Renton inspector.
2. Adequate separation between utilities as well as other features shall be provided in accordance
with code requirements:
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
3. All civil construction permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for
the most up-to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
4. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan
shall be on separate sheets.
5. Additional Building Permit Applications will be required for the following:
a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040.
3
b. Detention vaults for storm water flow control.
c. Demo of any existing structures on the project site(s).
6. Fees quoted in this document reflect the fees applicable in the year 2023 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to
the permit type. Please visit www.rentonwa.gov for the current fee schedule.
7. A demo permit is required for the demolition of the existing building. The demo permit shall be
acquired through the building department.
H:\CED\Planning\Current Planning\Admin Docs\templates\Staff Report Templates
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: February 29, 2024
TO: Pre-Application File No. 24-000037
FROM: Andrew Van Gordon, Associate Planner
SUBJECT: Kennydale Lakeline Sanitary Sewer West of Lake Washington Blvd
N from 2725 Mountain View Ave N to 3903 Lake Washington Blvd
N
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, Development Services Director, Development
Engineering Director, and City Council). Review comments may also need to be revised based on
site planning and other design changes required by City staff or made by the applicant. The
applicant is encouraged to review all applicable sections of the Renton Municipal Code. The
Development Regulations are available online at https://www.codepublishing.com/WA/Renton.
Project Proposal: The applicant proposes to install prefabricated individual lift stations that will
intercept the current side sewer exiting homes on the lake side of property on the shoreline of
Lake Washington. Sewage will be pumped through a 1.25-inch (1.25”) pressurized force main up
to Mountain View Ave N where it will be combined with a shared three-inch (3”) force main up to
the King County Interceptor located in Lake Washington Blvd N. A separate electrical system to
power the lift stations will be installed parallel to the new force main with some deviation when
needed. A control panel and backup generator for the electrical system is intended to be installed
between the parking for Kennydale Beach Park and Lake Washington Blvd N. Site restoration will
include minor drainage improvements, pavement and landscape restoration.
The scope of work will extend approximately from 2725 Mountain View Ave N to 3903 Lake
Washington Blvd N. Work will occur within public right-of-way, APN 3124059004, APN
3224059005 and on privately owned property. Access to the private property is proposed through
obtaining easements from the individual property owners.
Current Use: The existing sewer main is underwater withing Lake Washington. The sewer main
was originally constructed in 1972 to intercept side sewers from shoreline homes that previously
drained directly into Lake Washington.
1. Zoning /Land Use Designation, and Overlays: The project area is partially located within both
the Residential – 6 (R-6) zone and Residential – 8 (R-8) zone. The Urban Conservancy and
Single Family Residential shoreline designation in the Lake Washington Reaches overlays the
Kennydale Lakeline Sanitary Sewer
Page 2 of 6
February 29, 2024
project area. The purpose of the Urban Conservancy environment is to protect, conserve,
restore and manage existing areas with ecological functions of open space, floodplain, and
other sensitive lands where they exist in urban and developed settings, while allowing
compatible uses. The objective of the Single Family Residential Shoreline Overlay District is to
accommodate residential development and appurtenant structures that are consistent with
the Shoreline Management Element of the Comprehensive Plan.
The proposal would be considered a Utilities, Small use. Utilities, Small are defined as:
“Small scale facilities serving local areas within the City, including underground power lines,
water, sewer, and storm water facilities included within a Council-adopted utility system
plan, fiber optic cable, pump stations and hydrants, switching boxes, and other structures
normally found in a street right-of-way to serve abutting properties. Facilities also include
electric vehicle infrastructure located on public or private property such as a charging
station.”
Within the R-6 and R-8 zones small utilities use is permitted provided that aboveground
public utility facilities, such as water towers, reservoirs, water treatment facilities and pump
stations shall be treated with public art, subject to approval by the Arts Commissions.
If the proposed facilities are not included in a Council-adopted utility system plan, then the
proposal would be considered a Utilities, Medium use. Utilities, Medium are defined as:
“Moderate scale facilities serving the City, including subregional switching stations (one
hundred fifteen (115) kv and smaller), and municipal sewer, water, and storm water
facilities not included in a Council-adopted utility system plan.”
Within the R-6 and R-8 zones medium utilities use is reviewed and approved through an
Administrative Conditional Use Permit provided that aboveground public utility facilities,
such as water towers, reservoirs, water treatment facilities and pump stations shall be
treated with public art, subject to approval by the Arts Commissions.
2. Development Standards: The project would be subject to RMC 4-2-110A, Development
Standards for Residential Zoning Designations effective at the time of complete application
(noted as “R-6 standards” and “R-8 standards” herein).
Building Standards – The R-6 standards allow a maximum building coverage of 40 percent
(40%) of the lot area; the maximum impervious coverage is 55 percent (55%). The R-8
standards allow a maximum building coverage of 50 percent (50%); the maximum impervious
coverage is 65 percent (65%). The maximum wall plat height for both zones is restricted to 24
feet (24’) with a maximum of two (2) stories. Roofs with a pitch equal to or greater than 4:12
may project an additional six (6) vertical feet from the maximum wall plate height; common
rooftop features, such as chimneys, may project an additional four vertical feet (4’) from the
roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.) shall not extend
above the maximum wall plate height unless the projection is stepped back one-and-a-half
horizontal feet (1.5’) from each façade for each one vertical foot (1’) above the maximum wall
plate height. The maximum wall plate height for detached accessory structures is 12 feet (12’)
and the total floor area must be less than that of the primary structure. Accessory structures
are also included in building lot coverage calculations.
Kennydale Lakeline Sanitary Sewer
Page 3 of 6
February 29, 2024
New development would need to comply with the maximum building coverage, impervious
surface requirements, and building height regulations of the zone at the time of land use
application.
Setbacks – Setbacks are the minimum required distance between the building footprint and
the property line. The required setbacks for the R-6 zone are: Front yard and secondary front
yard (applies to corner lots): 25 feet (25’); Side yard: combined 15 feet (15’) with not less than
five feet (5’) on either side; Rear yard; 25 feet (25’). The required setbacks for the R-8 zone
are: Front yard: 20 feet (20’) except when all vehicle access is taken from an alley, then 15
feet (15’); Secondary front yard (applies to corner lots): 15 feet (15’); Side yard: five feet (5’);
Rear yard: 25 feet (25’).
New development would need to comply with zoning setbacks. Compliance with required
setbacks for new development would be verified at the time of land use application.
3. Significant Tree Retention: A review of COR Maps appears to show that there are mature
trees on the site. When significant trees (greater than 6-inch caliper or 8-caliper inches for
alders and cottonwoods) are proposed to be removed, a tree inventory and a tree retention
plan along with an arborist report, tree retention plan and tree retention worksheet shall be
provided with the formal land use application as defined in RMC 4-8-120. The tree retention
plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130,
Tree Retention and Land Clearing Regulations for further general and specific tree retention
and land clearing requirements.
In addition to retaining a minimum of 30% of existing significant trees, the project would be
required to provide a minimum tree density of 30 tree credits per net acre. Tree credits
encourage retention of existing significant trees with larger trees being worth more tree
credits.
TREE SIZE TREE CREDITS
New small species tree 0.25
New medium species tree 1
New large species tree 2
Preserved tree 6 – 9 caliper inches 4
Preserved tree 10 – 12 caliper inches 5
Preserved tree 12 – 15 caliper inches 6
Preserved tree 16 – 18 caliper inches 7
Preserved tree 19 – 21 caliper inches 8
Preserved tree 22 – 24 caliper inches 9
Preserved tree 25 – 28 caliper inches 10
Kennydale Lakeline Sanitary Sewer
Page 4 of 6
February 29, 2024
TREE SIZE TREE CREDITS
Preserved tree 29 – 32 caliper inches 11
Preserved tree 33 – 36 caliper inches 12
Preserved tree 37 caliper inches and greater 13
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant
trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas
and their associated buffers; significant trees over sixty feet (60') in height or greater than
eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting
properties from strong winds, which could otherwise allow such sheltered trees to be blown
down if removed.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical area or
its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City's discretion.
The Administrator may authorize the planting of replacement trees on the site if it can be
demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4-
130H.1.e can be met.
Unless exempted by critical areas, RMC 4-3-050C, or Shoreline Master Program Regulations,
RMC 4-3-090, no tree removal, or land clearing, or ground cover management is permitted
on portions of property with buffers associated with shorelines of the State, pursuant to
RMC 4-3-090, Shoreline Master Program Regulations. It is expected that removed significant
trees will be replaced based on the tree credit value of each significant tree removed.
Compliance with required setbacks for new development would be verified at the time of
land use application.
4. Fences/Retaining Walls: Fences or retaining walls installed as part of this project must be
designated on a landscape plan and grading plan with top of wall and bottom of wall
elevations. A fence and/or wall detail should also be included on the plan. A retaining wall
that is 4 feet or taller, as measured by the vertical distance from the bottom of the footing to
the finish grade at the top of the wall requires a building permit. The maximum height of any
fence or retaining wall is 72-inches subject to further height limitations in setbacks and clear
vision areas noted in RMC 4-4-040D. A fence shall not be constructed on top of a retaining
wall unless the total combined height of the retaining wall and the fence does not exceed the
allowed height of a standalone fence. For more information about fences and retaining walls
refer to RMC 4-4-040.
Kennydale Lakeline Sanitary Sewer
Page 5 of 6
February 29, 2024
5. Critical Areas: Per COR Maps the project area will take place within regulated shoreline areas,
high erosion hazard areas, medium and high landslide hazard areas, sensitive slope areas and
wellhead protection area zone 2. The overall purpose of the wellhead protection regulations
is to protect aquifers used as potable water supply sources by the City from contamination by
hazardous materials. Some uses are restricted that store, handle, treat, use, or produce
substances that pose a hazard to groundwater quality. Development within high seismic
hazard areas require a geotechnical study completed by a licensed professional.
A geotechnical report and hydrogeologic study may be required based on the final proposed
scope of work. Due to the project being located within regulated shoreline areas, shoreline
permitting is required. A standard stream or lake study prepared by a qualified biologist
would be required to demonstrate compliance with the Shoreline Master Program and
development criteria found in Critical Areas Regulations RMC 4-3-090. The study shall
demonstrate if the proposal meets the criteria of no net loss of ecological functions as
described in RMC 4-3-090D2. If the proposal requires mitigation for substantial impacts to
the existing vegetation buffer in order to demonstrate no net loss of ecological functions, a
supplemental stream or lake study is required. It is the applicant’s responsibility to
determine whether any other critical areas are present on the site prior to formal land use
application.
6. Environmental Review: The proposal would require environmental review pursuant to the
State Environmental Policy Act (SEPA). The project is located within the Urban Conservancy
shoreline designation and therefore WAC 197-11-800 does not apply. An Environmental
Checklist must be submitted with the proposal and the City’s Environmental Review
Committee is required to issue a Threshold Determination prior to any issuance for permits
on the site.
7. Permit Requirements: The proposed project would require a Shoreline Substantial
Development Permit, and Environmental (SEPA) Review. The applications would be reviewed
concurrently within an approximate timeframe of 6-8 weeks. The 2024 application fees would
total $5,071.50 ($3,030 Shoreline Substantial Development Permit review + $1,800 SEPA
Review + $241.50 5% technology fee = $5,071.50). Any modification requests to code
standards are $290.00 per modification + an additional 5% technology fee. All fees are subject
to change prior to submittal. Detailed information regarding the land use application
submittal can be found on the City’s Permit Center website. The City requires electronic plan
submittal for all applications.
8. Public Information Sign: Public Information Signs are required for all Type II and Type III Land
Use Permits as classified by RMC 4-8-080. Public Information Signs are intended to inform the
public of potential land development, specific permits/actions being considered by the City,
and to facilitate timely and effective public participation in the review process. The applicant
must follow the specifications provided in the public information sign handout. The applicant
is solely responsible for the construction, installation, maintenance, removal, and any costs
associated with the sign.
9. Impact Fees: It is not anticipated that there would be impact fees associated with the project.
A handout listing all of the City’s Development related fees is available for your review at
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=0&repo=CityofRe
nton
Kennydale Lakeline Sanitary Sewer
Page 6 of 6
February 29, 2024
Next Steps: When the formal application materials are complete, the applicant shall have the
materials pre-screened prior to submitting the complete application package. Please contact
Andrew Van Gordon, Associate Planner at 425-430-7286 or avangordon@rentonwa.gov to
submit prescreen materials and subsequent land use application.
Expiration: It is the applicant’s responsibility to monitor the expiration dates.