Loading...
HomeMy WebLinkAboutR-425001J J L�j m < I EL N N N 0 N 0 0 w I1 a) Go 0 U z 0 1n z < m X w i i co CD 00 O O 0 Do a w GENERAL SITE NOTES: 1. THE CONTRACTOR SHALL OBTAIN AND HAVE AVAILABLE COPIES OF THE APPLICABLE GOVERNING AGENCY STANDARDS AT THE JOB SITE DURING THE RELATED CONSTRUCTION OPERATIONS. 2. CONTRACTOR SHALL ENSURE THAT ALL NECESSARY PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION WHETHER SHOWN ON THESE PLANS OR NOT. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE OR SHOWN ON RECORD DRAWING PROVIDED BY OTHERS ARE SHOWN HEREON. EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND ARE SUBJECT TO A DEGREE OF UNKNOWN VARIATION. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. BARGHAUSEN CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR RECORDS OF OTHERS. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC., TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE APPROPRIATE UTILITIES INVOLVED PRIOR TO CONSTRUCTION. 6. INSPECTION OF SITE WORK WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE GOVERNING JURISDICTION. INSPECTION OF PRIVATE FACILITIES WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 7. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY THE CONTRACTOR SHALL CONTACT THE AGENCY AND/OR UTILITY INSPECTION PERSONNEL AND ARRANGE ANY REQUIRED PRE -CONSTRUCTION MEETING(S). CONTRACTOR SHALL PROVIDE ONE WEEK MIN. ADVANCE NOTIFICATION TO OWNER, FIELD ENGINEER AND ENGINEER OF PRE -CONSTRUCTION MEETINGS. 8. THE CONTRACTOR IS RESPONSIBLE FOR WORKER AND SITE SAFETY AND SHALL COMPLY WITH THE LATEST OSHA STANDARDS AND REGULATIONS, OR ANY OTHER AGENCY HAVING JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE "MEANS AND METHODS" REQUIRED TO MEET THE INTENT AND PERFORMANCE CRITERIA OF OSHA, AS WELL AS ANY OTHER ENTITY THAT HAS JURISDICTION FOR EXCAVATION AND/OR TRENCHING PROCEDURES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. 10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL ADJACENT PUBLIC AND PRIVATE PROPERTIES AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL EXISTING UTILITY SERVICES THAT ARE TO REMAIN OPERATIONAL WITHIN THE CONSTRUCTION AREA WHETHER SHOWN OR NOT SHOWN ON THE PLANS. 11. TWO (2) COPIES OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. ONE (1) SET WITH RECORDS OF AS -BUILT INFORMATION SHALL BE SUBMITTED TO BARGHAUSEN CONSULTING ENGINEERS, INC. AT COMPLETION OF PROJECT. 12. CONTRACTOR SHALL OBTAIN SERVICES OF A LICENSED LAND SURVEYOR TO STAKE HORIZONTAL CONTROL FOR ALL NEW IMPROVEMENTS. STAKING CONTROL SHALL BE TAKEN FROM ELECTRONIC PLAN FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. 13. CONTRACTOR SHALL REQUEST FROM BARGHAUSEN CONSULTING ENGINEERS INC., PRIOR TO ANY CONSTRUCTION STAKING OR CONSTRUCTION WORK, A FORMAL CONSTRUCTION RELEASE PLAN SET OR SPECIFIC RELEASE IN WRITING. THE APPROVED AGENCY PERMIT DRAWINGS WILL NOT BE CONSIDERED CONSTRUCTION RELEASE PLANS BY BARGHAUSEN CONSULTING ENGINEERS, INC UNLESS BARGHAUSEN CONSULTING ENGINEERS, INC HAS GIVEN A FORMAL WRITTEN RELEASE OR ISSUED A CONSTRUCTION RELEASE PLAN SET. CURB AND GUTTER NEW PROPERTY LINE BARRIER CURB CONCRETE COVER SHEET FOR CHICK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON N77'26'42"E 148.56' n • %1 S12°33'18"E 94.21� \ < LIMIT OF \ WORK -N20° 15'00"W 95.07'\ a \ N77'26'42"E 55.75' \ - .,'� ta \\ \\SA- C__1 c 0 30' 60' 120' SCALE: 1 "=60' S19°57'04"E 274.63' M %0 ,•;.tea. !'� V` \ Ad R' \ O NOTIFICATION REQUIREMENT NOTE: PROPOSED DEVELOPMENT INCLUDES WORK THAT MAY DISTURB ADJACENT PARCELS AND WITHIN A JOINT LEGEND ACCESS EASEMENT. CONTRACTOR TO CONFIRM WITH 4G DEVELOPMENT AND CONSULTING, INC. (951-970-9138) AND/OR CHICK-FIL-A FOR ANY RESTRICTIONS, TEMPORARY EASEMENTS OR AGREEMENTS PROPOSED FOR CONSTRUCTION, PROPER NOTIFICATION TIMING, AND PHASING CONSIDERATIONS TO LIMIT DISTURBANCE TO EXISTING ADJACENT PROPERTY OWNERS AND ALL PARCELS PARTY TO AFOREMENTIONED JOINT ACCESS EASEMENT. ASPHALT SAWCUT CONTOUR WATER WATER METER STORM SANITARY GAS POWER PAINT STRIPE TYPE 1 CATCH BASIN TYPE 2 CATCH BASIN SANITARY SEWER CLEANOUT a CURB PROPERTY LINE PAINT STRIPE CONCRETE CONTOUR WATER STORM TYPE 1 CATCH BASIN SANITARY SS MANHOLE GAS POWER OVERHEAD POWER UNDERGROUND GRAVEL/SAND (AS NOTED) ASPHALT BUILDING LINE WATER LINE OH/UG TEL. LINE ESTIMATED EARTHWORK OUANTITIES: CY CUT: 1,900 CY FILL: 900 CY NET: 1,000 CY (CUT) AREA TO BE DISTURBED 0.80 AC EARTHWORK QUANTITIES ARE APPROXIMATE AND HIGHLY DEPENDENT ON SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. CONTRACTOR SHOULD PERFORM INDEPENDENT ESTIMATE FOR BIDDING. LUMINAIRE (LUM.) YARD LIGHT POWER METER POWER POLE JUNCTION BOX (AS NOTED) 432 - - CATCH BASIN (CB) _ _ _ _ _ W _ _ _ _ STORM MANHOLE (SDMH) SANITARY SEWER MANHOLE (SSMH) -- -SD-- CLEANOUT (AS NOTED) ❑ GAS METER __SS__ GAS VALVE O WATER VALVE (WV) G FIRE HYDRANT(FH) CONNECTION (FDC) P (OHS WATER METER P (UG)- SIGN DIRECTIONAL ARROW - BOLLARD CONIFEROUS TREE - W - -T(xx)- DECIDUOUS TREE rs Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com MONUMENT PROTECTION NOTE: CONTRACTOR SHALL FIELD LOCATE ALL MONUMENTS WITHIN THE AREA OF DISTURBANCE PRIOR TO CONSTRUCTION AND PROTECT FROM DISTURBANCE/DESTRUCTION TO THE MAXIMUM EXTENT FEASIBLE. IF IT IS NECESSARY TO REMOVE OR REPLACE A MONUMENT DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION HAVING AUTHORITY (RCW 58.24.040) AND BE FULLY RESPONSIBLE FOR OBTAINING PERMITS FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES PRIOR TO DISTURBANCE/DESTRUCTION OR RELOCATION OR REPLACEMENT (WAC 332-120). APPLICATIONS MUST BE COMPLETED BY A REGISTERED LAND SURVEYOR AND MAY BE OBTAINED FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES: WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES PUBLIC LAND SURVEY OFFICE 1111 WASHINGTON STREET S.E.P.O. BOX 47060 OLYMPIA, WASHINGTON 98504-7060 (206)902-1 190 UPON COMPLETION OF CONSTRUCTION, ALL MONUMENTS DISPLACED, REMOVED, OR DESTROYED THAT ARE ABLE TO BE REPLACED, SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR, AT THE COST AND AT THE DIRECTION OF THE CONTRACTOR, PURSUANT TO THESE REGULATIONS. THE APPROPRIATE FORMS FOR REPLACEMENT OF SAID MONUMENTATION SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR. SITE PLAN NOTE: SITE PLAN HAS BEEN PROVIDED BY WARE MALCOMB. BARGHAUSEN CONSULTING ENGINEERS, INC. HAS NOT VERIFIED THE ACCURACY OF THE SITE PLAN. HORIZONTAL CONTROL NOTE: CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. SURVEYED: RLH DESIGNED: ADB DRAWN: MMM CHECKED: JC NO. REVISION BY DATE APPR APPROVED: ADB �A,ll�,xwo •u u V 1. N10'53' 15"E 42.03' 19'57'04"W 4 48' ��� y PROJECT INFORMATION HORIZONTAL DATUM - BASIS OF BEARINGS - NAD 83/91 THE HORIZONTAL DATUM FOR THIS PROJECT IS NAD 83(91) PER CITY OF RENTON. CITY OF RENTON CONTROL POINT NO. 60 WAS HELD FOR POSITION AND A LINE BETWEEN CITY OF RENTON CONTROL POINT NO. 60 AND CITY OF RENTON CONTROL POINT NO. 1898 WAS HELD FOR ROTATION BEING NORTH 67. 23' 14" EAST. VERTICAL DATUM - BASIS OF ELEVATIONS - NAVD88 THE VERTICAL DATUM FOR THIS PROJECT IS NAVD88 PER CITY OF RENTON. CITY OF RENTON BENCHMARK NO. 1920 WAS HELD FOR ELEVATION, BEING 27.87 FT. (NAVD88). PROPERTY ADDRESS 375 RAINIER AVE S RENTON, WA 98055 PARCEL NUMBERS: 000720-0149 000720-0215 LEGAL DESCRIPTION - SEE ALTA SURVEY SITE BENCHMARK MAG/WASHER IN SIDEWALK OF RAINIER AVENUE SOUTH AT THE NORTHEAST CORNER OF THE SITE, 2.0' SOUTHWEST OF RAINIER'S CURB THE ELEVATION FOR THIS MAG/WASHER: EL=30.63' (NAVD88) CIVIL SHEET LIST SHEET NUMBER SHEET TITLE C1.0 COVER SHEET C2.0 EXISTING CONDITIONS MAP C3.0 TESC AND DEMO PLAN C3.1 TESC DETAILS C4.0 GRADING PLAN - NORTH C4.1 GRADING PLAN - SOUTH C5.0 DRAINAGE PLAN C5.1 DRAINAGE DETAILS C5.2 DRAINAGE DETAILS C6.0 HORIZONTAL CONTROL PLAN C7.0 SITE PLAN C8.0 WASTEWATER AND WATER PLAN C8.1 WASTEWATER AND WATER DETAILS C9.0 COMPOSITE UTILITY PLAN C10.0 CFA DETAILS C10.1 CFA DETAILS C10.2 CFA DETAILS C10.3 CONSTRUCTION DETAILS C10.4 CONSTRUCTION DETAILS C 1 1.0 CONDITIONS OF APPROVAL LANDSCAPE SHEET LIST SHEET NUMBER SHEET TITLE L1 LANDSCAPE NOTES L2 LANDSCAPE REQUIREMENTS & CALCULATIONS L3 LANDSCAPE PLAN L4 PLANT SCHEDULE L5 LANDSCAPE DETAILS L6 IRRIGATION PLAN L7 IRRIGATION NOTES & DETAILS L8 IRRIGATION DETAILS L9 PATIO PLAN SITE INFORMATION Sw SUNSp� gVvp. SITE S 3RD STREET 5 q1N P�A�E RENTON, WASHINGTON VICINITY MAP N.T.S. UTILITY CONTACT INFORMATION EXISTING ON -SITE SURFACE AREAS TOTAL LOT AREA: 55,571 SF (1.28 AC) STORM DRAINAGE CITY OF RENTON TOTAL SITE AREA: 57,297 SF (1.32 AC) WATER 1055 S GRADY WAY RENTON, WA 98057 TOTAL ON -SITE IMPERVIOUS: 49,245 SF (1.13 AC) (425) 430-7299 TOTAL OFF -SITE IMPERVIOUS: 2,674 SF (0.06 AC) SANITARY SEWER CITY OF RENTON TOTAL PERVIOUS: 8,052 SF (0.18 AC) WATER 1055 S GRADY WAY RENTON, WA 98057 PROPOSED ON -SITE SURFACE AREAS (425) 430-7299 TOTAL LOT AREA: 55,571 SF (1.28 AC) TOTAL SITE AREA: 57,297 SF (1.32 AC) NATURAL GAS PUGET SOUND ENERGY TOTAL IMPERVIOUS: 45,311 SF (1.04 AC) ELECTRIC 10885 NE 4TH STREET TOTAL PERVIOUS: 11,985 SF (0.28 AC) BELLEVUE, WA 98009 (888) 225-5773 PARKING STALL INFORMATION PARKING STALLS REQUIRED: 54 TELEPHONE SERVICES COMCAST STANDARD PARKING STALLS: 24 (OTHERS AVAILABLE) ONE COMCAST CENTER COMPACT PARKING STALLS: 28 PHILADELPHIA, PA 19103 ADA PARKING STALLS: 2 (800) 934-6489 GEOTECHNICAL REPORT NOTES: OWNER 1. THE FOLLOWING GEOTECHNICAL REPORTS FOR THE SITE SHALL BE CONSIDERED PART CHICK-FIL-A, INC. OF THESE CONSTRUCTION DOCUMENTS: 5200 BUFFINGTON RD ATLANTA, GEORGIA 30349 SOILS REPORTS: GEOTECHNICAL ENGINEERING REPORT TEL: (404) 305-4407 JOB NUMBER: 81185084 DATE: 06/21 /2018 CONTACT: DON IKELER EMAIL: DON.IKELER@CHICK-FIL-A.COM ADDENDUMS: 1. STORMWATER INFILTRATION (8/24/2018) 2. LETTER OF ADDENDUM TO GEOTECHNICAL REPORT (7/22/2019) GEOTECHNICAL 3. GEOTECHNICAL ENGINEERING REPORT ADDENDUM (10/23/2021) 4. GEOTECHNICAL SUMMARY LETTER (04/06/2023) ENGINEER PREPARED BY: TERRACON CONSULTANTS, INC. TERRACON CONSULTANTS, INC. 21905 64TH AVENUE WEST SUITE 100, 21905 64TH AVENUE WEST SUITE 100 MOUNTLAKE TERRACE, WA 98043 MOUNTLAKE TERRACE, WA 98043 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL TEL: (425) 771-304 PROVISIONS OF THE SOILS REPORT FOR THE SITE BE OBSERVED AND COMPLIED CONTACT: DAVID A. BASKA, PHD, P.E. WITH DURING ALL PHASES OF THE SITE PREPARATION, GRADING OPERATIONS, FOUNDATION, SLAB, AND PAVING CONSTRUCTION. ENGINEER/LAN DSCAP E/ 3. ANY PROVISIONS OF THE SOILS REPORT WHICH CONFLICT WITH INFORMATION SHOWN ELSEWHERE ON THESE DRAWINGS, OR WHICH REQUIRE FURTHER CLARIFICATION, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER FOR DETERMINATION. 4. A REPRESENTATIVE OF THE SOILS ENGINEER SHALL BE AVAILABLE TO OBSERVE AND APPROVE THE EARTHWORK OPERATIONS AND TO VERIFY FIELD CONDITIONS AS WORK PROCEEDS. THE SOILS ENGINEER SHALL SUBMIT FIELD REPORTS CERTIFYING THAT THE METHODS AND MATERIALS OF THE EARTHWORK OPERATIONS WERE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS INVESTIGATION AND THAT THE WORK WAS PERFORMED TO HIS/HER SATISFACTION. 5. THE SOILS ENGINEER SHOULD BE NOTIFIED AT LEAST FIVE (5) WORKING DAYS PRIOR TO ANY SITE CLEARING OR GRADING. FLOOD ZONE PER FIRM 53033CO977G, MAP REVISED AUGUST 19, 2020. THE SUBJECT SITE FALLS IN ZONE "X", AREAS OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN. CIVIL SHEET LIST SHEET NUMBER SHEET TITLE IL-01 ILLUMINATION PLAN IL-02 ILLUMINATION PLAN DETAILS SCALE: ^ VERTICAL: NAVD 1988 1�-_/10� HORIZONTAL: NAD 1983/1991 CITY O F o + RENTON ONE INCH AT FULL SCALE Plonning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY ARCHITECT/SURVEYOR BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVE. SOUTH KENT, WA 98032 TEL: (425) 251-6222 FAX: (425) 251-8782 CONTACT: ALEX BELL, P.E./JEFF VARLEY, R.L.A./OWEN B. HILLE, P.L.S. ARCHITECT WARE MALCOMB 3015 112TH AVE NE #205 TEL: (425) 582-5517 CONTACT: NONY RIVERA EMAIL: NRIVERAOWAREMALCOMB.COM 0 Know what's below. p Call before you dig. ® Dial 811 DEVELOPMENT ENGINEERING yqi 12/05/2023 } [R-425001 IN COMPLIANCE WITH CITY OF RENTON STANDARDS A< SURFACE WATER UTILITY WASTEWATER UTILITY z J Farah 11 /21 /2023 jstowell 11 /27/2023 ' REGIONAL FIRE AUTHORITY eNTc WATER UTILITY t ��y,�. APPROVED �lrp ABDOUL GAFOUR 11 /21/2023 � e cthomas 11/22/2023 "4<F,xE011 DATE: O� COVER SHEET CURRENT PLANNING 0 03/29/2023 A V anGordon 12/OS/2023 FIELDBOOK: 0 FOR PAGE: CHICK-FIL-A RENTON DRAWING N0: ® 375 RAINIER AVE S RENTON, WA 98055 C 1 •0 STORE NO.:04249 SHEET OF: 20 N T 0 0 N W, u os H • H T N Q J co Nt 0 It r�1