CITY OF RENTON SURFACE WATER
STANDARD NOTES
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER HEREBY REFERRED TO AS APPLICANT MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR.
2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION.
3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE
WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO
CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS, ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO
THE CITY.
4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER,
SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY
THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION
FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY.
5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL
THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL
UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A
CONFLICT EXISTS.
7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY.
REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS.
8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND
MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL
BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY.
9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE
APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS.
10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE
DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED.
11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE
APPROVED BY THE CITY.
12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND
220.20,
13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 51NSIDE AND OUTSIDE.
14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN
204.10, 204.20, 204.30, AND 204.50. STRUCTURES SHALL HAVE:
• RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY.
• ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE.
• ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE
PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO.
15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM.
16. LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS
SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN.
17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE
DRIVEWAY TO THE BOTTOM OF THE DITCH.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 267.00
c®• PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR D:
�I� DEPARTMENT NOTES (1 OF 2) GAZ 9/28/2018
Publk works FEminlnram, DATE
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
FINISHED GROUND
D/4
D
'D/4
/
CULVERT CROWN FIELD CUT PIPE BEVEL
SEE NOTE 1
NOTEE
E
SEE
2
D/4 NOTE
t fl� 2
SEE NOTE 3
D
m
SEE
NOTE
2
6.
SIDE VIEW
CULVERT INVERT
'\/� ' •
��///�\I1 ,•
24"
.,.
FRnUT VIEW
5 3/4"x3/4" DIA. THREADED
10" (TYP.) ROD, 4" EMBEDMENT WITH
1/2" (TYP.) HEX HEAD NUT (TYP.)
1 112" 4., O 3/4" MAX. (TYP.)
(TYP.) (TYP.)
T- 1" MAX. 1" MAX.
' • D-2", SEE NOTE 1
INSTALL RESIN BONDED
ANCHOR (TYP.)
SECTION A
5 3/4"x3/4" DIA. THREADED
10" (TYP.) ROD, 4" EMBEDMENT WITH
'1. (FYP.) HEX HEAD NUT (TYP.)
1 112" 4" o 3/4" MAX. (TYP.)
(TYP.) (TYP.)
T-o 1" MAX. 1" MAX. 3 1/2"
L ' .
VARIES INSTALL RESIN BONDED
D-2", SEE NOTE 1 ANCHOR (TYP.)
SECTION B
7/8" DIA. HOLE I 3/8" x 4" x 10"
STEEL PLATE
1/ 3 (TYP.)
3" x 3" x 5/16"
STRUCTURAL TUBING
HEADWALL, SEE STD. PLAN
222.00 FOR DETAILS
SAFETY BAR (TYP.)
RESIN BONDED ANCHOR (TYP.)
- 3 1/2" x 3112" BLOCKOUT (TYP.),
FIELD CUT CULVERT TO MATCH
BLOCKOUT IN HEADWALL
CULVERT PIPE
OR PIPE ARCH
ISOMETRIC VIEW
NOTES:
1. D = INSIDE DIAMETER OF CULVERT PIPE, OR PIPE ARCH SPAN WIDTH, 36" MAXIMUM.
2. THE DISTANCE BETWEEN THE SAFETY BARS, AND BETWEEN THE TOP BAR AND THE
CULVERT CROWN, SHALL BE EQUAL SPACES OF NO MORE THAN 24". THE DISTANCE MAY
VARY 35/64" (31") BETWEEN BARS TO FACILITATE PLACEMENT.
3. SLOPE SHALL MATCH SIDE SLOPE; 6H:1V PREFERRED, NOT STEEPER THAN 4H:1 V.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 222.20
• PUBLIC WORKS TYPE 2 SAFETY BARS FOR CULVERT OR APPR D
VQ'1` DEPARTMENT GAZ 9/28/2018 1
PIPE ARCH (ON CROSS ROADS)
r"botwo,kswmminrato. DATE
IPE BEDDING
NOT TO SCALE
:45 AN
:45 AN
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
DRAINAGE DETAILS
FOR
CHICK=FIL=A RENTON
SECTION 18, TWP. 23 N., RGE 5 EAST, W. M.
CITY OF RENTON, KING COUNTY. STATE OF WASHINGTON
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT
AND SHALL MEET THE FOLLOWING SPECIFICATIONS:
• 4-8INCH ROCK /40-70%PASSING;
• 2-4INCH ROCK /30-40%PASSING; AND
• LESS THAN 2 INCH ROCK 110 - 20% PASSING.
19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE
CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS.
20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED, A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" SHALL BE LOCATED AT THE PROPERTY
LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00.
21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED
TO THE CITY PRIOR TO CONSTRUCTION.
22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV
ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL
PROJECT CURBS, GUTTERS AND/OR PAVEMENT.
23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS
AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS
TESTED.
24, FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL
EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN
264.00.
25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY
CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM
SYSTEM PROVIDED DURING CONSTRUCTION.
26, ADEQUATE SAFEGUARDS SAFETY DEVICES PROTECTIVE EQUIPMENT FLAGGERS AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE HEALTH AND SAFETY OF
THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED
RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY.
27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER
PROTECTION REGULATIONS (RMC 4-3-050).
28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF
STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A
SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS.
29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT.
30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM.
31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE
PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO
CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE
MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE,
THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING
ASTM C1781.
STD. PLAN - 267.10
Ar
%. PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR D:
DEPARTMENT NOTES (2 OF 2) GAZ 9/28/2018 I
DATE
DocuSign Envelope 1D: 6EECF5B6-602A-4E4A-B436-A317AA638878
3/4' FLAT FACE GOTHIC
❑❑
4❑❑ ❑
❑ STORM ❑ C 4"
❑ ° ❑ ❑ q T -� 8-13/16"DIA 1�-
° °
8-1/8"DIA
1 I 11
10-1/2" DIA
(2) 3/8"-16 SS SOCKET HEAD CAP 15" DIA
(1) OPEN PICKHOLE 1" SCREW (ALLENHEAD) W/WSHRS 5/8
ON A 8" DIA BOLT CIRCLE
PLAN VIEW FRAME SECTION COVER SECTION
CAST IRON FRAME AND
COVER, SEE NOTE 3 -
I---i
Qv
8" CLASS "B"
ASPHALT, SEE NOTE 4
CLEANOUT RISER, SEE NOTE 2
SOIL TIGHT 45' BEND
WYE
SOIL TIGHT
COUPLER
UNDERDRAIN, FOOTING
DRAIN COLLECTOR, OR
ROOF DRAIN COLLECTOR
PIPE, SEE NOTE 1
�� Illflfllflfll
TO OVERFLOW
STRUCTURE OR
STORM MAIN \
•�v�./i�✓% `MECHANICAL PLUG OR
CONTINUED CONNECTION
TYPICAL CLEANOUT CONFIGURATION
PAVED AREA (TYP.)
112" EXTEND CLEANOUT RISER
2" ABOVE DESIGN PONDING
ELEVATION OR PER PLAN FERNCO GASKETED
DESIGN PONDING QUIK CAP OR SIMILAR
ELEVATION 4"STREAMBED COBBLES
.;� PER WSDOT 9-03.11(2)
- 4" COMPACTED SAND OR
GRAVEL BACKFILL FOR DRAINS 8C_7Q Q�BC
PER WSDOT 9-03.12(4) O�
CLEANOU
SEE NOTE
NOTES:
1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10.
2. CLEANOUT RISER SHALL BE SAME SIZE AND MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE.
3. FRAME AND COVER SHALL BE EJ PRODUCT NO. 00367549BOl OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM".
4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE
COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI.
GENERAL NOTES:
1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100
FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT
CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES.
2. ALL FITTINGS SHALL BE SOIL TIGHT.
3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE.
4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 226.00
• PUBLIC WORKS APPROVED:
DEPARTMENT STORM SYSTEM CLEANOUT GAZ 9/28/2018 1
PubLt works nammrso-am, DATE
4 STORM CLEANOUT
NOT TO SCALE
Barghausen
Consulting Engineers, Inc.
18215 72nd Avenue South
Kent, WA 98032
425.251.6222 barghausen.com No- REVISION
:45 Al
:45 An
4", 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
6
5���0.(7c 3FFNO;
26 . TFs
/ \ L
P
A
fl
#3 BAR EACH CORNER
flZ.
fl
\ I N
#3 BAR EACH SIDE
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP",
STD. SPEC. 9-05.20
12"
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9-05.12(2)
15
' CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
))
9-05.50( 9 OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 11:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION.
ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING I5 NOTTO SCALE(NTS)
STD. PLAN - 200.00
..R PUBLIC WORKS APPR ED:
DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018
kubut works n°mlmsvamr DATE
#3 BAR EACH
CORNER 18" MIN.
TYPE 1 CATCH BASIN
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
MIN. 4,000 PSI COMPRESSIVE
STRENGTH CONCRETE BAND (TYP.)
DEPRESS LANDSCAPING 1"
PERMEABLE NEXT TO EDGE TREATMENT
PAVEMENT SECTION,
SEE STD. PLAN 261.16
._ 1U_
EXTEND TO BOTTOM OF /
PAVEMENT BASE
CONCRETE BAND AT LANDSCAPE
PERMEABLE FLUSH EDGES KEY OR EXPANSION JOINT
PAVEMENT SECTION, PER DPW APPROVAL (TYP.)
SEE STD. PLAN 261.10
IMPERMEABLE
PAVEMENT
O
2" MIN. EMBEDMENT KEY
FROM ADJACENT IMPERMEABLE
PAVEMENTBASE
CONCRETE BAND EXTEND TO
BOTTOM OF PAVEMENT BASE
CONCRETE BAND BETWEEN PAVEMENT
NOTES:
1. ALL PERMEABLE PAVEMENT APPLICATIONS SHALL CONFORM TO THE
CITY OF RENTON SURFACE WATER DESIGN MANUAL SECTION C.2.7 AND
WSDOT LOCAL AGENCY GENERAL SPECIAL PROVISIONS.
2. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 261.00
•tea PUBLIC WORKS PERMEABLE PAVEMENT - APPR D
'�1� DEPARTMENT EDGE TREATMENTS GAZ 9/28/2018 :45 AM
vubllt Works Mminlstratar UAIE
PERMEABLE PAVEMENT EDGE
xz
NOT TO SCALE
SURVEYED: RLH
DESIGNED: ADB
DRAWN: MMM
CHECKED: JC
BY DATE APPR APPROVED: ADB
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
SEE NOTE 4
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT. THE SURFACE
AREA OF THE BASE SECTION MUST BE
MORTARED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION 4�ADJUSTMENT SECTION
� F
BASE SECTION
NOTES:
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER,
DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO
MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED.
3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT.
4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Yz BOND.
5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR.
6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3.
7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-20.3(2).
8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS.
9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF
SUFFICIENT LENGTH.
10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 202.00
o PUBLIC WORKS PRO
RI
DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 1 9
V41307vobro woes n°mlmsn,to, DATE
:45 Al CATCH BASIN INSTALLATION
NOT TO SCALE
:45 Al
0 Know what's below.
p Call before you dig.
® Dial 811
R-425008
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY D DEVELOPMENT ENGINEERING `
J Farah 11 /21 /2023 yqi 12/05/2023
SCALE: DATE:
N/A VERTICAL: NAVD 1988 CITY OF o� DRAINAGE DETAILS
03/29/2023
HORIZONTAL: NAD 1983/1991
FIELDBOOK:
10
RENTON 0 FOR PAGE:
ONE INCH • CHICK-FIL-A RENTON DRAWING NO:
AT FULL SCALE Plonning/Building/Public Works Dept. ® IF NOT ONE INCH 375 RAINIER AVE S RENTON, WA 98055 C5
SCALE ACCORDINGLY
STORE NO.: 04249 SHEET: o OF: 20
T
N
J
vi
co
Nt
O
O
O
M1
W
r�1