HomeMy WebLinkAboutR-425016CONSTRUCTION DETAILS
M FOR
HI K-FIL=A RENTON0C C
I
SECTION 18, TWP. 23 N., RGE 5 EAST, W. M.
LLI
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
SEENUTE2 /B"R X 5/B"D DUMMY JOINT BEENOTE2
r
O' Z' - 0° T?
i
I
3/8- PREMOLDED JOINT FILLER (iYP) II CEMENTCONCRE
L — - CURBANDGUTIF.R
SEE SHEET C4.0
FOR GRADES
TOP Ij "
'.URB AND
UTTER PER
'7.0
EE SHEET C4.0
OR GRADES
SECTION A -A
NOT TO SCALE
J
w
m CONCRETE FLUME
NOT TO SCALE
CURB AND
GUTTER PER
C 7.0
TOP OF CURB
GUTTER FLOWLINE
//'�—
Barghausen
Consulting Engineers, Inc.
18215 72nd Avenue South
Kent, WA 98032
425.251.6222 barghausen.com
N0.
PLAN VIEW
FACEOF
CURB +_
CENTERUNEOF
FRAME 6 GRATE
6 1 2' 13'
1 /2" R. 1'LR
RROADWAX
FRAMEAND GRATE -NOT INCLUDED
IN CURB AND DUTTER.61D ITEM
SLOPE
TOP OF
REWCESS T ROADWAY
p .. •
D . • •' ADJUSTMENT SECnON - NOT INCLUDED
e ' IN CURS AND GUIrFER BID REM
CATCH BASIN - NOT DOAMED
D •
IN CURS AND GUTTER BIDIT6M
�.
SECTION
+4D
GENERAL NOTES-
1. The Intent of this design Is to facilitate the removal
of a catch basin with minimal disturbance
.'
of the curie.
'
2. The expansion joints of the
adjacent eldewalk shall
be adjusted to be In
line wlththesecurb
expansion joints.
I
? \ IS%4F-41C VIEW
STD. PLAN — 101.1
CEMENT CONCRETE CURB
PRO D:
* + PUBLIC WORKS
DEPARTMENT
INSTALLATION AT
CATCH BASINS
DA
REVISION
CITY OF RENTON STANDARD PLAN 101.1
NOT TO SCALE
SURVEYED: RLH
DESIGNED: ADB
DRAWN: MMM
CHECKED: is
BY DATE APPR APPROVED: ADB
SCALE:
N/A
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
2
a.
W
0
(D
Z
1--
0
O
LL
D_
O
LL.
Z
,OIJ
V
W
W
U)
BRICK
ARCHI
CONCI
ON GF
ih
TOP OF FINISHED WALL AS OCCURS
5 CONTINUOUS IN 8" DEEP
ROUTED BOND BEAM
" MASONRY WALL WITH #5
ERTICALS CENTERED AT 48" O.C.
ND HORIZONTALS REINFORCING
ER G.S.N. - GROUT SOLID BELOW
TRADE
INISHED GRADE OR TOP OF
AVING AS OCCURS
2'-0" WIDE x 12" THICK MINIMUM
CONCRETE FOOTING WITH 2 #5
CONTINUOUS
DOWELS TO MATCH AND LAP
VERTICAL WALL REINFORCING PER
TYPICAL DETAIL; ALTERNATE
BENDS.
2'-6" TO 4'-6" MAX - 6" MASONRY FREE STANDING WALL FOOTING
0 T URL CARUSO ■ TURLEY ■ SCOTT ■ INC.
WAS �
CONSULTING STRUCTURAL ENGINEERS
Q �. 1215 WEST RIO SALADO PARKWAY, SUITE JOB NUMBER DRAWN
18-1910 NCR
TM 11-03 23 TEMPE, ARIZONA 85281 WWW.CTSAZ.COM
Ph: (480)774-1700 Fax: (480)774-1701 DATE GR 11.03.2023 ENFDR
22020627 w�
GlSTER�� ��� TITLE CHICK-FIL-A RANIER AVE SHEET
s 303
�cTL'RAt 375 RANIER AVE S SSK7
RENTON, WA 98055
DRAW INGS/CALCULATIONS ARE CONSIDERED PRELIMINARY - NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE
3.0' MASONRY FREE STANDING WALL DETAIL
NOT TO SCALE
VERTICAL: NAVD 1988 •
HORIZONTAL: NAD 1983/1991 CITY OF
I
RENTON
NxilVR
Planning/Building/Public Works Dept.
0 Know what's b@IOW.
p Call before you dig.
1 Dial 811
J R-425016
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
F
yq i 12/05/2023 W
CONSTRUCTION DETAILS
0 FOR
CHICK—FIL—A RENTON
® 375 RAINIER AVE S RENTON, WA 98055
STORE NO.:04249
DATE:
03/29/2023
PAGE
DRAWING NO:
C10.4
SHEET: 19 OF: 20
1
L_J
T
N
J