HomeMy WebLinkAboutW-425001C) LO CV N ME- C) LO CV CV r�7 J J w m Q 7E Q 0 ai N O N 00 CT r' LJ LJ V) w Go 0 U z O in z Q d- x w i C Q) C co 00 0 O O 00 a w 0 10' 20' 40' SCALE: 1 "=20' UTILITY CROSSING TABLE CROSSING# IE UPPER UTILITY T/P LOWER UTILITY SEPARATION Ol 26.24 8" SD 24.74 3/4" W 1.50'± O 25.28 8" SD 23.78 3/4" W 1.50'± O 26.61 8" SD 25.83 6" SS 0.78'± ® 25.12 6" SS 23.62 3/4" W 1.50'± UTILITY CROSSING NOTE: CONTRACTOR IS TO PROVIDE A MINIMUM OF 1.5' VERTICAL SEPARATION BETWEEN SANITARY SEWER AND WATER, A MINIMUM OF 0.5' VERTICAL SEPARATION FOR DRY UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. SANITARY SEWER NOTES: 1. SANITARY SEWER CLEAN OUT PER CITY OF RENTON STANDARD DETAIL 403.1. SEE DETAIL 1 /C8.1. (TYP.) 2. ALL SANITARY SEWER CATCH BASINS SHALL BE PER DETAIL 6/C8.1. PROPOSED 13' X 19.5' ACCESS EASEMENT REC NO. 20230928000786 e^inr e^r,°.rn rn, iT, i nr 1—.1 nn., rrrn n.,e^rn — 7% REVISED 20' X 5' ACCESS EASEMENT REC NO. 20230928000786 /P SEWER EASEMENT REC NO. 5253595 1 165 LF NEW \ 3/4" TYPE K COPPER TUBING TO TRASH ENCLOSURE 10' GAS EASEMENT KC REC NO. 20130411001089 VA�V077 . 20 LF 6" PVC SS CAA 2.00% / CONNECT TO EXISTING SEWER G, �\ O O nn SIDE SEWER NORTH OF POINT DRAFTED BASED ON SIDE SEWER CARD #2067318 FROM THE CITY OF RENTON. CONTRACTOR TO INDEPENDENTLY VERIFY, THE LOCATION OF THE SIDE SEWER AND NOTIFY BARGHAUSEN OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. a G UTILITIES CONSTRUCTED UNDER TED-40-4063 TO REMAIN IN AREAS OF PROPERTY NOT DISTURBED BY EXPANSION WORK \ YY Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com 15' X 100' / SEWER EASEMENT REC NO. 9708110700 d 4 0 WASTEWATER AND WATER PLAN FOR CHICK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON REVISION SURVEYED: RLH DESIGNED: ADB DRAWN: MMM CHECKED: JC BY DATE APPR APPROVED: ADB \ \ \ \ O \ \ so SID \ k \ ` 59 XISTING RPBA TO \ RASH ENCLOSURE. ELOCATE AND s \ \ ELISE RPBA IF \ \ ALVAGEABLE. 'ILITIES EASEMENT 0001119 ` \ c \ �-- POWER EASEMENT \ KC REC. NO. 9410201209 m s f 9 ' - \ \ SLOPES & UTILITIES EASEMENT \ --- - - --- ---- ------- \ SCALE: VERTICAL: NAVD 1988 171=20' HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY �S 10°53' 15"W 42.03' S19°57'04"E 48' SS�O N A L ENG CITY OF RENTON Plonning/Building/Public Works Dept. O UTILITY POTHOLING NOTE: THE CIRCLED LOCATIONS ARE REQUIRED TO BE POTHOLED TO VERIFY VERTICAL AND HORIZONTAL LOCATION OF EXISTING UTILITY AND/OR POTENTIAL CONFLICTS WITH EX. UTILTIES. POTHOLING SHOULD OCCUR PRIOR TO INSTALLING ANY PROPOSED UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. UTILITY POTHOLING: SEE SHEET C9.0 FOR POTHOLING REQUIREMENTS 0 Know what's below. p Call before you dig. ® Dial 811 S-425001 FW--425012 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/05/2023 WASTEWATER UTILITY ffAV,% ~� jstowell 11 /27/2023 DATE: WASTEWATER AND WATER PLAN 03/29/2023 FIELDBOOK: E% FOR PAGE: CHICK-FIL-A RENTON ® 375 RAINIER AVE S RENTON, WA 98055 C8.0 STORE NO.:04249 SHEET 12 OF: 20 CV T O O co CV W, W , oo H • T CV Q J co O O 00 cc ,a