HomeMy WebLinkAboutW-4250030 10' 20' 40'
SCALE: 1 "=20'
J
J
Li
m
Q
Q
O
O
N
O
N
O
a
c�
w
Q0
m
Oo
i
0
U
Z
0
in
z
Q
a-
X
w
c
Go
co
O
O
CD
a
w
�v
�1
7-7 %�11
10' WIDE ACCESS ESMT -
REC NO. 7607260646
RELINQUISHED
09/28/2023
REVISED 20' X 5' -
ACCESS EASEMENT
REC NO. 20230928000786
N
SEWER EASEMENT
REC NO. 5253595 N
!t
PROPOSED 13' X 19.5' -
ACCESS EASEMENT
REC NO. 20230928000786
COMPOSITE UTILITY PLAN
FOR
CHICK=FIL=A RENTON
SECTION 18, TWP. 23 N., RGE 5 EAST, W. M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
f \ !
\
!
T s \ ! \
!
\
D \ \
\
o \
G \ \
PROP. DRIVE THROUGH !
CANOPY PER ARCH. PLANS oo \
10' GAS EASEMENT
°. D° o' KC REC. NO. 20130411001089wo
� \
�.
0 ° D G
D G
POWER EASEMENT ° ° g \ �'� PHILIPS LUMINAIRE POLE
�
KC REC NO. 9410201209 4T a \ r PER TENW ILLUMINATION PLAN
'427
16l • a ; G
°o CIA
d ° \
QD
2
w
5
v
P°
3 C,
\ p 0 °
1 o y SLOPES & UTILITIES EASEMENT
PER 20110620001119 C
\ ° ..o Ira ° ° �\v \.
10' GAS EASEMENT \ o ° �° \ °'° 4 !o c `\ \ \
KC REC NO. 20130411001089
0 \ \ \
\ �D d \
\
` - ° ° \\
a o \
\16 CB
4 ° ° . v \ `Ilk01
\
s� c POWER EASEMENT
G �' c KC REC. NO. 9410201
°d / GG \ .
\ N sa y D O' S
SD SD SD •eFf.••p? - d. ,
SD SD SD SD O So
SD SD j,� SO e : •D
i
o
\ • �. O 'O
d F46
41
4 °
/ .. ...
A.
d .
° G . ° G pi S SS SS . / a • SG 6
SEWER EASEMENT \ a :o 4.
i 5 p .d• / /
REC NO. 5253595 /\ e. sN o 4 .6 /
D d °
/ ° .ID d
UTILITIES CONSTRUCTED UNDER
TED-40-4063 TO REMAIN IN
AREAS OF PROPERTY NOT
DISTURBED BY EXPANSION WORK
Barghausen
Consulting Engineers, Inc.
18215 72nd Avenue South
Kent, WA 98032
425.251.6222 barghausen.com
15' X 100' /
SEWER EASEMENT
REC NO. 9708110700
G d e
No.
s�
REVISION
BL�G
e . ��• "00
SURVEYED: RLH
DESIGNED: ADB
DRAWN: MMM
CHECKED: JC
BY DATE APPR APPROVED: ADB
GAS VALVE (TYP.)
Fos, j—A
s.
m `
4
/ SLOPES & UTILITIES EASEMENT
KC REC NO. 20110811001003
P�W. Wxx 0
AWFA
UEDA
\\S\
cn
1
10' GAS EASEMENT
1
4.
1
pONA4D
S 10'53' 15"W �' E W A S
42.03' Q a.� 'y/�
\ 10 21036182
S19°57'04"E ���F�FG/STE���,
�4.48' SS/O N A L ENG
CITY OF
RENTON
Planning/Building/Public Works Dept.
UTILITY NOTES:
OTHE CIRCLED LOCATIONS ARE REQUIRED TO BE POTHOLED TO CONFIRM WHETHER
OR NOT UTILITY CONFLICTS NEED TO BE RESOLVED. POTHOLING SHOULD OCCUR
PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING
ENGINEERS, INC. OF ANY CONFLICTS.
IS TO PROVIDE A MINIMUM OF 1.5' VERTICAL SEPARATION BETWEEN
OCONTRACTOR
SANITARY SEWER AND WATER, A MINIMUM OF 0.5' VERTICAL SEPARATION FOR DRY
N
UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC.
OF ANY CONFLICTS.
O
O
UTILITY PROTECTION NOTE:
o
C'7
UTILITY LOCATE DATA INDICATES THE EXISTENCE OF AN EXISTING GAS SERVICE
N
LOCATED UNDER THE SIDEWALK AND CURB RETURN OF RAINIER AVENUE. THE
U
CONTRACTOR SHALL ORDER INDEPENDENT UTILITY LOCATES AND TAKE ANY OTHER
NECESSARY ACTIONS TO CONFIRM THE HORIZONTAL AND VERTICAL LOCATIONS.
EXISTING GAS SERVICE TO BE PROTECTED.
UTILITY CROSSINGS: SEE SHEET C8.0 FOR CROSSING TABLE
< DRY UTILITIES CONSTRUCTION NOTES:
1. PROPOSED POWER LINE TO CANOPY.
2. RELOCATE POWER TO BUILDING AS NEEDED FOR MENU BOARD
CONSTRUCTION.
3. EXISTING TRANSFORMER TO BE REMOVED AND RELOCATED.
4. RELOCATE AND REUSE IF SALVAGEABLE EXISTING RPBA TO TRASH
ENCLOSURE.
5. PROPOSED GAS LINE TO CANOPY.
6. APPROXIMATE LOCATION OF PROPOSED TRANSFORMER.
COORDINATE CONDUIT SIZE, METER LOCATION AND CONTRACTOR
SCOPE OF WORK WITH PURVEYOR AND MEP PLANS PRIOR TO
CONSTRUCTION.
0 Know what's below.
p Call before you dig.
® Dial 811
S-425003 W-425003
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
Ar% IL
yqi 12/05/2023 W
WASTEWATER UTILITY
jstowell 11 /27/2023
DATE:
COMPOSITE UTILITY PLAN o3/29/2023
FI ELDBOOK:
E% FOR PAGE:
CHICK-FIL-A RENTON DRAWING NO-
® 375 RAINIER AVE S RENTON, WA 98055 C9•0
STORE NO.:04249 SHEET 14 OF: 20
os
T
N
Q
J
M
O
O
CID
r1�