Loading...
HomeMy WebLinkAboutR-410912LEGAL DESCRIPTION 0 7- THE NORTH 2 � ACRES OF THE SOUTH EAST QUARTER OF THE SOUTHEAST QUARTER OF NORTHWEST QUARTER IN SECTION 5, TOWNSHIP 22 NORTH, RANGE 5 EAST 5 EAST, W.M IN KING COUNTY WASHINGTON. 0 EXCEPT THE EAST 30 FEET FOR ROAD. ALSO EXCEPT THE RIGHT OF WAY FOR 106TH AVENUE SOUTHEAST: AND ALSO EXCEPT THAT PORTION THERE OF CONVEYED TO THE STATE LJJ OF WASHINGTON FOR STATE ROUTE 515 BY DEED RECORDED UNDER RECORDING NO 8906291184: SITUATED IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WASHINGTON 12'x4'X DEEF STANDARD LOCKING MH FRAME & LID SEE KCRE DWG NO. 7-022 FOR DETAILS OF HAND HOLD, STEPS OR LADDE SEE KCRDCS DWG 7-01 OF CITY OF RENTON PROPOSED STM MH^(TYPE-11 ^48'^)^I ^I^ n DETENTION VAULT - PLAN VIEW SCALE :1 "=5'-0" INFORMATION SHOWN ON THIS DRAWING REGARDING EXISTING UTILITIES IS COMPILED FROM TOPOGRAPHY SURVEY BY CENTREPOINTE CONSULTANTS. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE AND CONFIRM THE LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES, AND ADVISE THE ENGINEER OF ANY POTENTIAL CONFLICTS. SURVEY BENCHMARK CITY OF RENTON BM 1852, BRASS DISC IN CONIC SI NE 4TH ST AND 148TH AVE SE. PUBLISHED 138.614 METERS NAVD 88 = 454.769 FEET CITY OF RENTON BM 2110 - 1/8" BRASS PIN IN 3" CONIC MON IN CASE AT THE SI OF SE 176TH ST AND 116TH AVE SE PUB ELEV = 448.162 NAVD88 SURVEY CENTREPOINTE CONSULTANTS 14209 29TH ST E #105 SUMNER, WA 98390 PHONE: (253) 987-7859 PORTION OF THE NORTHWEST 4, SECTION 5, TOWNSHIP 24 NORTH, RANGE 5 EAST. W.M. STRUCTURAL PLANS FOR THE WET VAULT TO BE SENT SEPERATELY FOR THE SPECIFICATION OF WATER RESTRICTOR REFER TO PLAN 237.0 OF CITY OF RENTON, SHOWN ON THIS SHEET. \ L lo� 12'x4 SUMP PIPE FROM CB INV EL=455.45 INSTALL FROP WITH PIPE SUPPORTS THAT IS OPEN ONE THE BOTTOM AND ON THE TOP INV=447.16 SEE FLOW RESTRICTOR SEE LADDER RUNGS ETAILS IN THIS SHEET FOR ALL NOT SHOWN ORIFICE ELEVATION FOR CLARITY. _ I r5�x10' GRATE OPENING RIM EL=465.1 PL FINISHED GRADE 0.5' x10' GRATE OPENING M EL=466.2 FINISHED GRADE 5'x10' GRATE 5'x10' GRATE OPENING OPENING RIM EL=464.5 RIM EL=466.2 CONSULTANT MAINLAND ENGINEERING CONSULTANTS CORPORATION UNIT 206 8363 128TH STREET SURREY, B.C. V3W 4131 TEL: (604) 543 8044 FAX: (604) 543 8104 EMAIL: CIVIL@MAINLANDENG.COM 5. REISSUED FOR REVIEW SGC 2023/03/14 4. REISSUED FOR REVIEW SGC 2022 12 02 3. REISSUED FOR REVIEW SGC 2021 /04/14 2. IREISSUED FOR REVIEW MK 2020/06/19 1. ISSUED FOR REVIEW MK 2019/11 /19 N0. REVISION BY DATE PL _,TOP OF LIVE TOP OF DEAD STORAGE TOP SEDIMENT STORAGE 5'x10' GRATE OPENING FINISHED GRADE RIM EL=467.5 --i AB SURVEYED: SURVE AB DESIGNED: EM AB AB DRAWN: MK AB CHECKED: RM APPR APPROVED: AB 7' GRATE OPENING EL=467.5 SCALE: AS SHOWN ONTALLN D 1983/1991 HORIZONTAL: ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY TOP OF LIVE STORAGE TOP OF DEAD STORAGE INV=451.70 TOP OF LIVE i0.7 STORAGE �.7 TOP OF DEAD STORAGE 48 7 TOP SEDIMENT STORAGE INV=447.70 2023-03-15 re.:7,y=rw,.,npg IE: GEE *3G6.6QE Ara1E�� e�,r "�,%6A 17 T$ RE W OVAR E'A45TERTIrAT Clk1PLING ICR FLAANGG - 'I MN CI faoeMOF TfT ANY F10WNT N OF FLIAT R&5THlGT4)R TEE INCLLOL'44 ELEIMI 7 MN ELBOOP RE S TALC TOA, SEE DETAIL w4 NOTE 10 6MN r WIN. a- uAx 1uTE wElrsr, TO EUN2* ► ft nw.n..0 AS W CFWCD M NOrt S ELB4'rf RE�iF�T+a1R iIET�LIL ELIVAnm PER FLANS 12'MN UNDEN PAVIFL"T AllaTR]NAL�•^ IR Rl1fIC�Iw SLTSITD ALLOL4 AG�DE55 T4 T: S OR ti'MJLT3 WHEN CATCH 19 F ILL® WITH WATER t ANCLE AS / tN�4[-SSARY, tf 8E3E NOTE 7 rf FRAWE 8&Oub COWER AMIaumj- 0Arr WITH LCCKM WETS PFR ,STIT PI AN ?OL 9P 719' ILE14lt. vERT+CJNI6" {DATE FVI SECCHDARL' INLET 4v WIN. WATER! EIllIM,REBTIMlffrM 7qjff.jZF 3ltbIETAILA1NbF4bYf 10 HNIG'i4LDra SEEPS. ORLADOEP PFE SUPPORTS 5EE NOTE 6 ITS } 5-0 f SERE NOTE P jTIP r h!N 7 MN. I D 1 IIIIETRIC I I CUTLET PPE. BEE INLET PIPE FIDTEJL T 111. 7 NvEkT AND SHEAR STATE WITH OCHTROL ROD FOR CI FAN. l.tpAPN"IEINT J4d DEwf4iEn CLEAN ELEVAT1014 PER FL044 FUR VERTICft AlI91YENTY.fTN WVER-I I7'5afxTE7N or PIP! A1TAJ7.1l0 LY PER BTp PLAN 317. GAkSPETED BAND TO ALLOW REIADVAL II" MIN_ MI I.Mg RiSTR1GTOR PLATE WITH ORIFICE DIAAS SPECFNEDI SEE ROTE 10 Ncrnm SE01ION A 1, LEEAWMAPAJWOFA54'DIAMETERTYPE 2CATCH Et4BFI. ] M fLWF r.- A fry' fWygAR or YfIOP/Q P{AK FWW. 1. METAL PAM PREFERNED TO BE STAIIE.FM STEEL ALLYAHCMD STEEL. OR ALUIINKM ALL OTHER STEEL PARTS MUST EE G LVANQED WITH TREATWENTS 1, 2. OR 5. 4 rRAm ANo L AcazR QR STRP Wr$9T 5a A CLEANOLFT GATE ISVIABLE FROM TOP. EI. CLM4'_D04r1N SPACE IS CLEAR OF RISER AHD CLEANCUT GATE t. FROAE IS CLEAT! of OJN& 4. IF METAL OUTLET PIPE CONNEGTS Tl] CEMENT CONCRETE POPE: OIJfLET PPE TO HAVE SMOOTH 0.0. EQUAL TO DON(3RETE PIPE I D LEES IN E. PFkUn[E AT LEAST ONE t R bW OAOE SUPPORT &RACKET AfNCNOIRIEA TO COmMETE STALL. IL"MLIIR S'-0`vEftTf:4L 9PAC7NC;. 7. LOCATEELBOW RESTRIGTORISIA5NECESSARY TOPROVIDE NINIWUMICLEARANCEASSHIMW 6. LOCATE AD MOKAL LADI ER PouI,IOili N STRUCTURE& UEMAS ACCESS TO TAmKaAPC YALILTS TO ALLO* A.C'CES9IILT•TEN CwTCM BASIN 0 FiLuwwTtt wATEFR 0. WHEN CONNECTNG TO A NEW PIIPE U5E A FLEXIBLE OOFMIECTOR IKOR-NySEAL DWI WTTH GORRL*ATED PFE A016WI R OR rWFROM1EO Ei'LLP&)- WHEAL DONNE TING TGAi EXISTING PIPE USE A FABRi ITED SAND COLL.IA OF THE &ME I1M,TERI1il AS THE C04NEC71NS PFE ID. IF TIN MKTIPN I$ 4slD ONLY rC R WILL CONTflol, TI-IM RILDOW REMTN N311%AND RESTRICTOR PLATES W1rH oRIrkrEs ARE NoT REoUFRo. U"LES5 @"E FMt% NOTED, DU M NG 15 lIOT TQ SGLLE II I 0 t TD. PLAN - 237.00 PUBLIC WORKS FLOW CONTROL STRU�CT'IJRE - AZ 9/28/2D16 I DEPARTMENT RESTRICTOR TEE .., DATE NOTES 1. MINIMUM RESTRICTOR ORIFICE DIA. TO BE 0.25". 2. ADJUSTMENT IS REQUESTED TO LENGTHEN THE FLOW OF THE VAULT AND KEEP THE EXIT ON THE SAME SIDE; AND KEEP THE LENGTH TO WIDTH RATIO OF VAULT MORE THAN 3:1 , BAFFLE IS OMMITED AS RATIO LENGTH TO WIDTH RATIO OF VAULT POOL IS GREATER THAN 5:1. CALL 48 HOURS BEFORE YOUR DIG CALL 811 C TY OF RENTON Planning/Building/Public Works Dept EMERGENCY OVERFLOW EL=460.7 PIPE SUPPORTS (2 MIN) 3"x0.090 ALUMINUM W/J' STAINLESS BOLTS OUTLET PIPE MAX. WS=460.7 ORIFICE #3(0.82" DIA) 4" ELBOW INV EL=459-21• /--18.0" RISER ORIFICE #2(1.39" DIA) 4" ELBOW INV EL=456$3 F SHEAR GATE 452.70 r12" MIN. Z 0_.50% SLOPE RESTRICTOR PLATE WITH 1 T 4 ° ORIFICE ELEV=450.7 DRILL A 0.55" IN PLATE N °'n 1 n BOLTED TO FLANGE OR T DRILLED TO CAP Q Z N on LADDER RUNGS ALL NOT SHOWN FOR CLARITY. n � Q Q Q 447.16 a a a Q a a :4 5 AP CONDITION OF APPROVAL: ORIFICE ELEVATIONS ARE MEASURED FROM THE OUTLET PIPE ELEVATION AND NOT FROM THE BOTTOM OF THE FROP TEE. ORIFICE ELEVATIONS TO BE SET AT THE ELEVATIONS RED -LINED ON THE PLANS. 459.21 1458.081 Cox i I MAN FLOW RESTRICTOR SEE DETAIL �- (FOR SPECIFICATION REFER TO STD Q PLAN 237.00 OF CITY OF RENTON.) SHOWN ON THIS SHEET SCALE :1 "=2' R-41 0912 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS u� 0 EDEVELOPMENT ENGINEERING SURFACE WATER UTILITYJV% z l Sippo 03/30/2023 J Farah 03/30/2023 ' LLl Q DATE 2023/03/14 M A D U E N O SHORT PLAT FIELDBGOK: W PAGE: 19805 108TH AVE SE, RENTON, WA 98055 DRAWING NO: 0 COMBINED DETENTION 8c WET 12 0 VAULT DETAILS SHEET: 12-OF-42