Loading...
HomeMy WebLinkAboutR-410928O LLJ D 0 0 I U W 0 n W LLJ Z LEGAL DESCRIPTION THE NORTH 2 z ACRES OF THE SOUTH EAST QUARTER OF THE SOUTHEAST QUARTER OF NORTHWEST QUARTER IN SECTION 5, TOWNSHIP 22 NORTH, RANGE 5 EAST 5 EAST, W.M IN KING COUNTY WASHINGTON. EXCEPT THE EAST 30 FEET FOR ROAD. ALSO EXCEPT THE RIGHT OF WAY FOR 106TH AVENUE SOUTHEAST AND ALSO EXCEPT THAT PORTION THERE OF CONVEYED TO THE STATE OF WASHINGTON FOR STATE ROUTE 515 BY DEED RECORDED UNDER RECORDING NO 8906291184: SITUATED IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WASHINGTON SITE DATA TAX PARCEL NO: 052205 9078 SITE ADDRESS: #19805 108TH AVE SE RENTON, WA 98055 TOTAL SITE AREA: 97,174 SF ZONING: R-4 POLE CAP ALLOY 43 WITH S.S. SCREWS LID I / 4 1/2" O.D. GROUND LUG WITH 3/8" DIAMETER HOLE OPPOSITE HANDHOLE I BRACKET OR MAST ARM LENGTH SHOWN ON STREET LIGHTING PLANS WIRE HOLE WITH 1" I.D. RUBBER GROMMET , TAPERED BRACKET 0.125" WALL ALLOY 6063-T6 EXTRUDED POLE PLATE ALLOY 6063-T6 WITH 1/2"-.13 NC ALUMINUM HARDWARE TAPERED ALUMINUM TUBE 0.250 WALL ALLOY 6063-T6 SATIN GROUND FINISH 3'-6" MIN. NO. 151 HANDHOLE (4"X6" NOMINAL) ALLOY A356 T6 NON -FLUSH WITH COVER AN S.S. HEX. HEAD SCREWS (FRAME TAPPED 1/2" .13 NC FOR GROUNDING). MOUNT ON SIDEWALK 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH DESIGN AND SIDE CONSTRUCTION STANDARDS SECTION 6.14 AND REFER TO WSDOT STANDARD SPECIFICATION SEC. 8-20.2(1) BASE FLANGE ALLOY A356 T6 WITH 2. MOUNTING HEIGHT INCREASES BY 6" WHEN BREAKAWAY BOLT COVERS AND S.S. HEX. HEAD COUPLINGS ARE USED. SCREW 3. APPROVED LIGHT POLES ARE VALMONT SERIES 21 AND SERIES GROUT BETWEEN BASE FLANGE AND 22 STANDARDS AND MAST ARMS FOUNDATION IF A BREAKAWAY 4. APPROVED LIGHT FIXTURES ARE AUTOBAHN ATBM H MVOLT R3 COUPLER IS NOT REQUIRED NL P7. BREAKAWAY COUPLER SEE SECTION SEE CURB AND GUTTER DETAILS 6.14.0 AND STANDARD PLAN 6-89 FOR ADDITIONAL INFORMATION FOR FOUNDATION AND ]-BOX. NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLICATE. THE ORIGINAL, SIGNED BY THE WASF FA ENGINEER AND APPROVED FOR PUBLICATION IS KEPT ON FILE AT �� OF I1 �� THE CITY OF KENT. A COPY MAY BE OBTAINED UPON REQUEST. ���� CITY OF DENT ENGINEERING DEPARTMENT KENT CITY LIGHT STANDARD 38296 WASHINGTON r� w 0 I STERN �1y� DESIGNED COK SCALE NONE STANDARD PLAN DRAWNCOK SSIQAAL CHECKED COK DATE 12/2019 6 - 8 6 APPROVED ENGINEER ELEVATION - 40 FOOT 2" N.T.S. SLIP FITTER 40 FOOT MOUNTING I HEIGHT 2'-0" MIN. SEE DETAIL 6-86A FOR STRAIN RELIEF SIDEWALK DRIVEWAY- - L FACE 10' MIN. OF CLEARANCE CURB FROM DRIVEWAY AGI- CALCULZATION ZONE PRINTOUT COMPONENT SCHEDULE 1 METERBASE: 100 AMP ILLUSTRATED. PROVIDE 150 AMP WHEN AND IF DESIGN LOAD REQUIRES, 4 JAW SAFETY SOCKET, AW #114TB, WITH 5TH JAW AT 9:00 POSITION (CONTRACTOR TO VERIFY WITH SERVING UTILITY). 2 PANELBOARD: 120/240 VAC, 100 AMP (150 AMP IF NEEDED), 1 PHASE, 3 WIRE, COPPER BUS, 12 CKT 100 AMP MAIN BREAKER, WESTINGHOUSE BAB2100, 2 POLE WESTINGHOUSE BAB BOLT -ON BRANCH BREAKERS: 4-20/2 ILLUMINATION BRANCH; 1-40/1 SIGNAL BRANCH; 1-20/1 GROUND FAULT RECEPTACLE & CONTROL BRANCH. -SEE NOTE 4 3 CONTACTOR: LIGHTING RATED, 30 AMP, 4 POLE, 120 VAC COIL, (AS REQUIRED). 4 PHOTO ELECTRIC CELL: 1800VA, 120 VAC, ALR #SST-IES (PER WSDOT SPEC). 5 PHOTO -CELL BYPASS SWITCH, SPDT, 15 AMP, 277 VAC. 6 GROUND FAULT RECEPTACLE, 120 VAC, DUPLEX, 20A CABINET: NEMA 3R, PADMOUNT, 1/8" ALUMINUM CONSTRUCTION, 2CL SCREENED AND GASKETED VENTS M DOORS: HEAVY DUTY CONCEALED HINGES (LIFT-OFF TYPE) SEE NOTE 1 STAINLESS STEEL VAULT HANDLES, PADLOCKABLE METER DOOR BEST BLUE CONSTRUCTION LOCK ON DISTRIBUTION DOOR SEE NOTE 2 POLISHED WIRE GLASS WINDOW IN METER DOOR `D CLOSED CELL NEOPRENE GASKET, CARD HOLDER ° FINISH: POLYESTER POWDER COAT, NONE OUTSIDE, WHITE INSIDE LU ° } z 120/240 VAC SEE NOTE 5 = - 1° 3W 1-® M SEE NOTE 3 EE NOTE 6 METER BASE MAIN CONTROL SIGNAL 'LTG L ONE -LINE DIAGRAM PHOTO 0 ELECTRIC CELL 6" 2" (lYP) 0.17' �� I L_ TEST SWITCH GROUND FAULT RECEPTACLE 0 E- 24" 1611 Go; SERVICE CABINET SKYLINE CABINET SERIES 47700-KM-100 OR APPROVED EQUAL BY TESCOR. METERING SECTION CLEARANCES & EQUIPMENT PER PSE AND EUSERC UL LISTED PER STANDARD #508 SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT CABINET FINISHED FRONT SURFACE SIDE CONDUITS TO BE INSTALLED WITHIN THE CONCRETE PEDESTAL TO SERVE THE CABINETS (TYP) in D o° � 4 ri p 4 CLASS 3000 CONCRETE BASE CONCRETE BASE 20" NOTE: THIS PLAN IS NOT A LEGAL ENGINEERING DOCUMENT BUT AN ELECTRONIC DUPLICATE. THE ORIGINAL, SIGNED BY THE j� F � I ENGINEER AND APPROVED FOR PUBLICATION IS KEPT ON FILE AT �� pF WASly j THE CITY OF KENT. A COPY MAY BE OBTAINED UPON REQUEST, Qq"�'T 4 �00 CITY OF KEN`-' �r7 \ �� ENGINEERING DEPARTMENT ti • SERVICE CABINET, CONCRETE KENT 38296 BASE AND ONE LINE DIAGRAM C� WA8HINOTON � GIST �'�� DIESIGNE COK SCALE NONE STANDARD PLAN DRAWNCOK sSIONAL CHECKED COK DATE 2-2019 6 — g 6 E APPROVED NGINEER PROPOSED KENT SERVICE CABINET SURVEY BENCHMARK CITY 0E KENT BENCHMARK NO 7073 PUNCH IN 3" BRASS DISC, INCASED, LOCATED AT THE INTERSECTION DE SOUTH 2O0TH STREET AND 100TH AVE SOUTHEAST. ELEVATION: 343.77 FEET SURVEY CENTREPOINTE CONSULTANTS 14209 29TH ST E #105 SUMNER, WA 98390 PHONE: (253) 987-7859 CONSULTANT MAINLAND ENGINEERING DESIGN CORPORATION UNIT 206 8363 128TH STREET SURREY, B.C. V3W 401 TEL: (604) 543 8044 FAX: (604) 543 8104 EMAIL: CIVIL@MAINLANDENG.COM 4, UPDATED PER CITY COMMENTS MK 2022/04/19 3, UPDATED PER CITY COMMENTS MK 2021 /09/29 2. UPDATED PER CITY COMMENTS MK 2021 /03/08 1, DRAWING ISSUED FOR KENT LIGHTING MK 2020/08/24 N0. REVISION BY DATE SURVEYED: SURVEYED A B DESIGNED: RM AB A B DRAWN: MK AB CHECKED: RM APPR APPROVED: AB FUTURE 40' - -- LIGHT - STANDARD C/W 190E LED 150W NG 150 E HPS ON PSE POLE X TERMINATE CONDUIT INSIDE PROPOSEDJBOX UTILITY SERVICE FROM THIS POLE 10OA-120/240V SERVICE CABINET CONDUIT INSIDE PROPOSEDJBOX ..YyV EXISTING 15OW LIPS GN PSE POLEXISTING / E SANITARY MANHOLE LEAVE EMPTY STUB -OUT 3" FROM JBOX Z OFUTURE 40' Z LIGHT STANDARD C/W 190W LED W 0 O H L.� HYDRANT V V PLAN SCALE. 1 "50' 2022-07-26 SCALE: VERTICAL: NAVD 1988 1 s _50 HORIZONTAL: NAD 1983/1991 ONE INCH D A TU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY O M N VICINITY MAP 1 " 1 000' CONSTRUCTION NOTES: 1. ALL LUMINAIRES SHALL BE SUPPLIED AND INSTALLED TO SUIT THE CURRENT EDITION OF THE CITY OF KENT GENERAL CONDITIONS. 2. ALL CONSTRUCTION OF THE STREET LIGHTING SYSTEM SHALL MEET ALL THE GENERAL CONDITIONS OF THE CITY DE KENT AND KENT REFERENCES TO WSDOT STREET LIGHTING STANDARDS. LIGHTING LEGEND PROPOSED 40 FOOT LIGHT STANDARD WITH 12 FOOT MAST ARM C/W 190W AUTOBAHN LED FIXTURE (ATBM H MVOLT R3 NV PL) FUTURE 40' POLE IF FUTURE RE -DEVELOPMENT OF EAST SIDE OF 108 AVE ---- WERE TO TAKE PLACE (LIGHTING CALCULATIONS BASED ON FUTURE DAVITS) - 3#8 USE-2 Conductors & 1#12 USE-2 BOND inside 2" Schedule 80 RPVC Conduit C.O. 2" Schedule 80 RPVC Conduit only D.S. 2" Schedule 80 RPVC U/G Dip Service C/W 3#2 USE-2 Service Conductors ITT Service Cabinet ( Voltage 120 / 240 ) Service Main Breaker Size 100 Amps. Service on or from Utility Power Pole ( Voltage 120 / 240 ) R Streetlight on Red Phase Conductor B Streetlight on Black Phase Conductor ■ Proposed Street Light Junction Box ROADWAY LIGHTING DESIGN CRITERIA PER: KENT STANDARD (TABLE 6.15) ROADWAY (NAME) 108 AVE S.E. ROAD CLASSIFICATION PRIMARY ARTERIAL PEDESTRIAN CONFLICT LOW ILLUMINANCE RECOMMEND/DELIVERED 1.5Fc/1.6Fc UNIFORMITY RECOMMENDED/DELIVERED 3:1 / 1.9:1 MAX/MIN 6:1 / 3.6:1 MIN ILLUMINATION 0.8 Fc LIGHT LOSS FACTOR 0.76 SPACING (STAGGERED) 230' STAGGERED (50' ROAD WIDTH) FUTURE LIGHT LOCATIONS USED IN CALCS ASSUMES FUTURE EAST SIDE REDEVELOPMENT EQUIPMENT: FIXTURE TYPE: LED I WATTAGE: 190W I MTG. HEIGHT: 40' DIST TYPE: 3M IES FILE: I MODEL: IATBMHMVOLTR3NLP70 NFORMATION SHOWN ON THIS DRAWING REGARDING EXISTING UTILITIES IS COMPILED FROM DIVERSE SOURCES, AND MAY NOT BE COMPLETE OR ACCURATE. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE AND CONEIRM THE LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES, AND ADVISE THE ENGINEER OF ANY POTENTIAL CONFLICTS. I IVA No. RE C-2204826 BASED ON THE SUBM TTED DRAWINGS AND SPECIFICATIONS PROVIDED BY THE A-PPLICANT'S LICENSED ENGINEERS, SURVEYORS ACID ARCHITECTS AND OTHER CERTIFIED PROFESSIONALS, THESE PLANS ARE APPROVED FOR CONFORMANCE WITH THE CITY OF KENT ENGINEERING DIVISION'S REQUIREMENTS U N O O O O 0 D C O O O O 0J / k 4 0 0 410915 IN COMPLIANCE WITH CITY OF KENT STANDARDS 0 CALL 48 HOURS EL BEFORE YOUR D C CALL 811 4 H C TY OF MADUENO SHORT PEAT DATE: FIELDDBO K: PAGE: KENT _D/O4/19 � 0 19805 108TH AVE SE, RENTON, WA 98055 El— DRAWING No: Planning/Building/Public Works Dept. 8 CL STREET LIGHTING PLAN SHEET Q OF 10