HomeMy WebLinkAboutT-38472100 M I O Co a 0 O L0 0 SP -I 320 ILLUMINATION, TRAFFIC SIGNAL SYSTEMS, AND ELECTRICAL 8.20,2(1) Equipment List and Drawings Paragraph four of Section 8-201 is deleted and replaced as (allows The Contractor shall submit for approval an sets of shop drawings far each of Me following typos astandards rated for on This projecb 1. Light standards with or without pre -approved Plans. Paragraph five of Section 8-20.2(1) is deleted. 81 Foundations Section 8-20.3(4) is revised and supplemented as follows: The anchor halts shall match that of Me device to be installed thereon. Concrete shall be placed against undisturbed earth if possible. Disturbed earth or backfill material shall be compassed to 95 percent of the material's maximum density. Before placing the concrete the Contractor shall block-out around any other underground carries that Ile In the excavated base so that the concrete will not adhere to the utility line. Concrete foundations shall be troweled, brushed edged and finished in a workmanship -like manner. Concrete shall be promptly cleaned from the exposed portion of the anchor bolls and conduit after placement. Foundation shall all be Class 3000 compete. After the specified curing Traded, the Contractor may Install Me applicable device thereon. All concrete foundations shall be constructed in Me manner specified bi t. Where no sidewalks are to be instilled the grade tar Me top M Me foundation shall be P above the finished grade of surrounding landscaping. 2. Where sidewalk or imsed Islands are to be constructed as a pan of this project, the top of the foundation shall be made rush with the tap of Me sidewalk or island (See detiil sheet) All concrete foundations shall be located as per stationing an Me Plans at as laated by Me Engineer in Me Tient. 8.20.3(8) Conduit Section 8-20.3(5) is revrsed and supplemented as follows: The paragraph requiring galvanized steel conduit at cerin locations Is deleted. Galvanized steel conduit (RGS) shall only be placed ifso indicated in the Plans. RGS conduit and things shall be slowed only where intercepting existing RGS conduit. Pull Wires shall be installed by the Contractor. am.m,m nmprm �'Y gmrs SP -5 Cry Pack matter grout shall consist of a 1:3 mature of pomand cement and fine sand with just enough ureter so that Me mixture will stick together on being molded into a bell by hand and will not exude morsture when so pressed A one half-inch drain hole shall be led in the bottom of Ma Brod pad as samar on the standard call. DIVISION 9 MATERIALS 9.29 ILLUMINATION, SIGNALS, ELECTRICAL 9.29.1 Conduit Section 9-29.1 is supplemented as follows: The conduit PVC -non-metallic shall be of Me Nm types indicated below: 1. Schedule 80 Extra heavy wall PVC conforming W ASTM. Standards, tape used in all installations under roadways. 2. Schedule 40 heavy wall PVC conforming in ASTM Standards. 429.2 Junction Boxaa (RC) Section 9-29.2 is supplemented as allows: Junction boxes shall be reinforced concrete with galvanized deal fame anchored in place and galvanized steel aver plate (Diamond pdmm) as indicated on decal shares. Junction boxes far copper wire shall incorporate a locking lid per City of Renton Standard Delds. Juncl an boxes in sidewalks shall have con-sdd Ids. 9.29.3 Conductors, Cable Section 329.3 Is revised and supplemented as follows: Items 8 and i t are revised as allows: e. Detector loop wire shall be IMSA 51-T(orerpetuba)d12 or 014 AWG stranded copper s 11. Communications able shall meet REA specification PE -39 and shall have No. 19 AWG vires with 0.008 inch FPAIMPR coded aluminum shielding. The able shall have a petroleum compound completely filling the inside of Me cable. Each Who shall be numbered at each terminal end with a wrap-around type numbering ship baring the circult number shown on the Plans. The Contractp shall provide and Install all the necessary Wring, fuses and fiMngs so as to complete the Installation of the signal and lighting equipment as shown on Me Plans. All reasons and installation methods, except as noted otherwise herein, shall comply with applicable sections M the National Electrical Code. 9-299 Ballast, Transformers uc.w, msmnp.m evry.ugmn dCALL 2 WORKING DAYS BEFORE YOU DIG: (Z5 811 SP -2 Except intercepting existing RGS conal all conduk shall be rigid non-metallic unless P e 9 g g retract otherwise in the Piens or Special Provisions. At conduit openings shall be hied with approved bell -ends or Bushings. Well thickness a conduit shall be consistent within continuous conduit runs with no mixing of different schedule types between terminations. The Contractor shall prawde and Install all conduit and immunity ratings at the locations noted on the Plans. Conduit sea shall be as indicated on the wiring and conduit schedule shown on Plans. Conduit to be provided and ingather shall be M Me type indicated below: Schedule 40 heavy wall PVC Conforming to ASTM standards shall be used whenever the condult is to be placed other than within the roadway area. Schedule 80 extra heavy wall PVC Conforming to ASTM standards shall be used when the conduit's to be placed within the roadway area. At joints shall be matte wlth strict compliance to the manufacturers recommendations regandirg cement used and environmental conditions. 2Junction 0.onJu otIo Boxes Section 8-20.3(fi) is supplemented az follows: All Model boxes and associated concrete pacts shall be installed on compacted sub grade Which shall include six inches of 518th -inch minus crushed surfacing top course material Installed under and around the base of lane junction box. The function box shall include installation a a 4" thick pad and a 12- diameter cement concrete pad enclosing Me junction box as per plans, specifications and detail sheets. Concrete shall Ica promptly cleaned tram the junction box frame and lid. Jumped boxes shall have galvanized sail Inds and frames. Junction boxes used for electrical wiring shall utilize a locking IM per City of Renton Standard Details. 8.20.3(9) Bonding, Grounding Section B-20,3(9) is supplemented as follows AI street light standards, signal poles and other standards on which electrical equipment is mounted shall be grounded to a copper clad metallic ground rod 518 inch in diameter x 8'0° in length complete with a a AWG bare copper bonding strap located in Me nearest junction box. At signal controller abineb and slgnaNrghting service cabinets shall be grountled W a 518 Inch in diameter x 8'17 in length toolbar clad metallic ground rod located in the nearest junction baa eennm, munup,m .uµv.�r4mu SP -6 Section 9-29.9 is supplemented as follows: The Ballast shall be pre -wired a the lamp socket and teminel based. 9.29,1of21 Decoretive Luminaires Ratlway scale luminaires shall be: Cyclone Lighting CY55131-GAL-3120W-0K-240-0P3624-RAL9005TX. O.A.E. Cyclone Lighting CY55P1-GAL-3-8UW-0K-246 CP3624-RAL9005TX, O.A.E. Roadway snake luminaire arms shall be: Cyclone Lighting CP412 C1(6']FBXX-RAL9Di O.AE. Cyclone Lighting CP4124-C1(1 ZYBM-RAL9005TX, O.A.E. Roadway sake poles shall be: Valmont 40RTA Pole: 4000WOOST4NRALINOW5011TCSGP013-BK62, O.A.E. Pe lestran stake luminaires shall be: Cycler Lighting CYMS5P1-GAL- M4K-240. P3924-RALWOBU,O.A.E. Pedestrian stake arms shall be: Cyclone Lighting CP4124-Ci14-}E OC-RAL9005TX, 01 Perdegnan stake pokes shall be: Valmont 21' 4' RTA Pole: 210440TO6T4A1RAL900514ORTCS011013-8K62, O.A.E 3291 Phatselectric Controls Section 329.1112) is deleted and replaced as follows: Photoelectric controls shall be a plug-in Mercer rated to operate on 120 volts, 60 Ha The unit shall consist of a light emotive element connected to necessary control relays. The unit shall be so designed Mat a fellows of any electronic component will energize the lighting cards. The photo all shall be a solid state device whh stable lumon "dues in the temperature range a-55 degrees C W ♦TO degrees C The photo cell shall be mounted externally on top of the luminaire. In a contactor controlled system, the photo all to control the system shall be mounted on the luminaire nearest to Me servicelcontidor cabinet. The photo all shall be capable of swltdting -ON' 1,000 wafts of incandescent load as a minimum. The phoacell shall be rated tar a 20+ War Inde span. e.xma wRwuogrm ewssmwM VERTICAL DATURk CITY OF RENTON, NAVD 88 BENCHMARK. CITY OF RENTON CONTROL POINT NO. 1864 WAS HELD FOR ELEVATION, BEING 19.488 FEET (NAVD88) SP -3 with a bare copper bonding step sized in accordance with Me Plans, specifications and appkiabke came. Ground rods are considered miscellaneous items and all costs are 0 be included with Me system or conductors. Ground straps are also miscellaneous items unless a separate pay item is provided in Me -Schedule of pdcesi 8G20,3(10) Service& Transformer, Intelligent Transportation System Section 8-20.3(10) is revised and supplemented as (allows Paragraph taro is deleted. Paragraph three is deleted. The f slowng is added Power serves shall be single phase 120/240 volt, 3 wire 60 cycle A.C. (street lighting contactor/traffic signal, grounded neutral service) Per City of Renton Standard Details. The Power service paint shall be as noted an the Plans and well be verified by the electrical servicing utility. 8.28. 13 Illuminatlon 3( ( Systems 8-203(13RA Light Standards Search 8-20.3(13)A is deleted and replaced as tallows Light standards shall he handled when leading, unloading, and erecting in such a manner that they will not be damaged. Any pans that are damaged due to the Contractors operations shall be repaired or replaced at the Contractors expense, to the satisfaction of Me Engineer. Light standards shall not be erected on concrete foundations until foundations have set at least 72 hours or attained a compressive strength of 2.400 psi, and shall be raked sufficiently to be plumb after all load has been placed, or as p(hervme directed by Me Engineer. Light Standards shall be credact in accomance with section 8-20.314). Anchor bolts shall extend through the top M1eavy-hex nut two, of threads to the extent Possible Anchor bolts shell be tightened by Me Tum.01-Nut Tightening Method in accordance wit Sections 6-03.3(33) and 8-20.3(4). Anchor bobs damaged after to foundation concrete is placed shall riot be repaired by bending or walling. The Contractor's repair procedure is to be submitted W the Engineer for approval prior W making any repairs. The procedure is W include removing Me damaged portion of Me anchor bolt, coding threatls on Me undamaged ponies to remain, the installation of an approved threaded sleeve not and stud, and reporting Me foundation with epoxy concrete repair. The grout pad shall not extend above Me elevated of the bottom of the bass. vexaNn.l�m apvJ nrgmrf CHECKED FOR COWILIANCE TO CITY BTANDARDB Date Date— Date— SP4 Anchor Base: A one piece anchor base of adequate strength, shape and size shall be secured to Me Inner end of the shaft so Mat Me base shall be capable of resisting at its yield pant Me bantling moment of Me shaft at its yield point. The base shall be provided with four sbded or round holes to receive the anchor bolls. Nut covets shall be provided with each poke. Anchor BOBS: Four steal anchor bolts, as& flttid with two hex nuts and has washers, shall be fumishad with the pole. Anchor hefts shall meet Me requirements of Section 9-06.5(3) and 9-08.5(4). The anchor bolt yield point shall be capable of warning Me bending moment of the pole shaft at its yield point. The Contractor shall assure that all anchor bolts conform to the recommended ASTM specifications M me pole manufacturer ant shall secure and submit be Me City fat approval all manufacturer data on pole bending moment, anchor bolt fabrication data, lest results and any other data Mal may be required to confirm that the anchor bolts meat these specifications. Miscellaneous Hardware: All hardware (bolts, nuts, screws, washes, etc.) needed to complete Me installation shall be stainless steel. I.D. (Identification for poles): The Contractor shall supply and install a combination of 4 - Ttllgits and one letter on each pole, Whether individual lumdaire or signal pole with luminaire. The letter and numbers combination shall be mounted at Me 15 foot level an lie pole facing approaching traffic. Legends shall be added with transparent film, resistant to door "sell and ultraviolet exposure. The decal markets shall be 2 -1a -inch square with yellow reflectorized 2 -inch legend on a black background. The I.D. number will be assigned to each pole at Me end of the contract or project by the Transportation Maintenance Assistant Manager and tooMinated through the City Inspector. Cost for the recalls shall be considered Incidental to Me contract bid. Light standards shall meet the pole detail requirement below and the detail sheets on the approved plan documents. The pole shaft shall be provided With a 4" x 6' flush hand hole near the base and a matching metal cover secured with stainless steel screws or bolts. The pole shall be adjusted far plumb after all needed equipment has been installed thereon. After pole is installed aid plumbed nuts shall be tightened on anchor bobs using proper sa ed sockets o end or box wrenches. Use of fers wrenches or other basis that can Pen r .pipe damage ofine muss. will not be permitted Tools shall foundation M sufficient size to achieve adequate base torquing to the pati. TM1e space betweenpack orconcrete and trovron antl the bottom of the pole base piste shall Must filled with a dry pack monar grout and troweletl to a smooth finish conforming a Me contour of Me pole base plate. NOTE: THE 2014 WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION AND THE CITY OF RENTON SPECIAL PROVISIONS SHOWN ON THIS SHEET SHALL BE CONSIDERED PART OF THESE CONTRACT DOCUMENTS. THE FRONTAGE ILLUMINATION SCOPE OF WORK SHOWN ON SHEETS IL1.01 THRU IL1.09 SHALL BE CONSTRUCTED IN ACCORDANCE WITH THESE WSDOT STANDARD SPECIFICATIONS AND CITY SPECIAL PROVISIONS. IKEA PROPERTY INC dER j 420 ALAN WOOD ROAD Q Z '• WAS/y C,t CONTACT: DWGHT E. SLATON CONSTRUCTION MANAGER ( P: (610) 834-0180; C. 303-549-4623 (W E: DWGHTSLATONOIKEACOM IL ENGINEER O T TRANSPORTATION TRANSPORTATION ENGINEERING NORTHWEST 3NAL fiq SE 8TH STREET, SURE 200 Z BELLNUE, WA 98004 Z Q 0��.��'�Qil ILL! E: DUBREUILOTENW.COM Z Q w J 0 0 Q W w > Q W F Z Q O � ir LL Q ILL! Y 0 SP -I 320 ILLUMINATION, TRAFFIC SIGNAL SYSTEMS, AND ELECTRICAL 8.20,2(1) Equipment List and Drawings Paragraph four of Section 8-201 is deleted and replaced as (allows The Contractor shall submit for approval an sets of shop drawings far each of Me following typos astandards rated for on This projecb 1. Light standards with or without pre -approved Plans. Paragraph five of Section 8-20.2(1) is deleted. 81 Foundations Section 8-20.3(4) is revised and supplemented as follows: The anchor halts shall match that of Me device to be installed thereon. Concrete shall be placed against undisturbed earth if possible. Disturbed earth or backfill material shall be compassed to 95 percent of the material's maximum density. Before placing the concrete the Contractor shall block-out around any other underground carries that Ile In the excavated base so that the concrete will not adhere to the utility line. Concrete foundations shall be troweled, brushed edged and finished in a workmanship -like manner. Concrete shall be promptly cleaned from the exposed portion of the anchor bolls and conduit after placement. Foundation shall all be Class 3000 compete. After the specified curing Traded, the Contractor may Install Me applicable device thereon. All concrete foundations shall be constructed in Me manner specified bi t. Where no sidewalks are to be instilled the grade tar Me top M Me foundation shall be P above the finished grade of surrounding landscaping. 2. Where sidewalk or imsed Islands are to be constructed as a pan of this project, the top of the foundation shall be made rush with the tap of Me sidewalk or island (See detiil sheet) All concrete foundations shall be located as per stationing an Me Plans at as laated by Me Engineer in Me Tient. 8.20.3(8) Conduit Section 8-20.3(5) is revrsed and supplemented as follows: The paragraph requiring galvanized steel conduit at cerin locations Is deleted. Galvanized steel conduit (RGS) shall only be placed ifso indicated in the Plans. RGS conduit and things shall be slowed only where intercepting existing RGS conduit. Pull Wires shall be installed by the Contractor. am.m,m nmprm �'Y gmrs SP -5 Cry Pack matter grout shall consist of a 1:3 mature of pomand cement and fine sand with just enough ureter so that Me mixture will stick together on being molded into a bell by hand and will not exude morsture when so pressed A one half-inch drain hole shall be led in the bottom of Ma Brod pad as samar on the standard call. DIVISION 9 MATERIALS 9.29 ILLUMINATION, SIGNALS, ELECTRICAL 9.29.1 Conduit Section 9-29.1 is supplemented as follows: The conduit PVC -non-metallic shall be of Me Nm types indicated below: 1. Schedule 80 Extra heavy wall PVC conforming W ASTM. Standards, tape used in all installations under roadways. 2. Schedule 40 heavy wall PVC conforming in ASTM Standards. 429.2 Junction Boxaa (RC) Section 9-29.2 is supplemented as allows: Junction boxes shall be reinforced concrete with galvanized deal fame anchored in place and galvanized steel aver plate (Diamond pdmm) as indicated on decal shares. Junction boxes far copper wire shall incorporate a locking lid per City of Renton Standard Delds. Juncl an boxes in sidewalks shall have con-sdd Ids. 9.29.3 Conductors, Cable Section 329.3 Is revised and supplemented as follows: Items 8 and i t are revised as allows: e. Detector loop wire shall be IMSA 51-T(orerpetuba)d12 or 014 AWG stranded copper s 11. Communications able shall meet REA specification PE -39 and shall have No. 19 AWG vires with 0.008 inch FPAIMPR coded aluminum shielding. The able shall have a petroleum compound completely filling the inside of Me cable. Each Who shall be numbered at each terminal end with a wrap-around type numbering ship baring the circult number shown on the Plans. The Contractp shall provide and Install all the necessary Wring, fuses and fiMngs so as to complete the Installation of the signal and lighting equipment as shown on Me Plans. All reasons and installation methods, except as noted otherwise herein, shall comply with applicable sections M the National Electrical Code. 9-299 Ballast, Transformers uc.w, msmnp.m evry.ugmn dCALL 2 WORKING DAYS BEFORE YOU DIG: (Z5 811 SP -2 Except intercepting existing RGS conal all conduk shall be rigid non-metallic unless P e 9 g g retract otherwise in the Piens or Special Provisions. At conduit openings shall be hied with approved bell -ends or Bushings. Well thickness a conduit shall be consistent within continuous conduit runs with no mixing of different schedule types between terminations. The Contractor shall prawde and Install all conduit and immunity ratings at the locations noted on the Plans. Conduit sea shall be as indicated on the wiring and conduit schedule shown on Plans. Conduit to be provided and ingather shall be M Me type indicated below: Schedule 40 heavy wall PVC Conforming to ASTM standards shall be used whenever the condult is to be placed other than within the roadway area. Schedule 80 extra heavy wall PVC Conforming to ASTM standards shall be used when the conduit's to be placed within the roadway area. At joints shall be matte wlth strict compliance to the manufacturers recommendations regandirg cement used and environmental conditions. 2Junction 0.onJu otIo Boxes Section 8-20.3(fi) is supplemented az follows: All Model boxes and associated concrete pacts shall be installed on compacted sub grade Which shall include six inches of 518th -inch minus crushed surfacing top course material Installed under and around the base of lane junction box. The function box shall include installation a a 4" thick pad and a 12- diameter cement concrete pad enclosing Me junction box as per plans, specifications and detail sheets. Concrete shall Ica promptly cleaned tram the junction box frame and lid. Jumped boxes shall have galvanized sail Inds and frames. Junction boxes used for electrical wiring shall utilize a locking IM per City of Renton Standard Details. 8.20.3(9) Bonding, Grounding Section B-20,3(9) is supplemented as follows AI street light standards, signal poles and other standards on which electrical equipment is mounted shall be grounded to a copper clad metallic ground rod 518 inch in diameter x 8'0° in length complete with a a AWG bare copper bonding strap located in Me nearest junction box. At signal controller abineb and slgnaNrghting service cabinets shall be grountled W a 518 Inch in diameter x 8'17 in length toolbar clad metallic ground rod located in the nearest junction baa eennm, munup,m .uµv.�r4mu SP -6 Section 9-29.9 is supplemented as follows: The Ballast shall be pre -wired a the lamp socket and teminel based. 9.29,1of21 Decoretive Luminaires Ratlway scale luminaires shall be: Cyclone Lighting CY55131-GAL-3120W-0K-240-0P3624-RAL9005TX. O.A.E. Cyclone Lighting CY55P1-GAL-3-8UW-0K-246 CP3624-RAL9005TX, O.A.E. Roadway snake luminaire arms shall be: Cyclone Lighting CP412 C1(6']FBXX-RAL9Di O.AE. Cyclone Lighting CP4124-C1(1 ZYBM-RAL9005TX, O.A.E. Roadway sake poles shall be: Valmont 40RTA Pole: 4000WOOST4NRALINOW5011TCSGP013-BK62, O.A.E. Pe lestran stake luminaires shall be: Cycler Lighting CYMS5P1-GAL- M4K-240. P3924-RALWOBU,O.A.E. Pedestrian stake arms shall be: Cyclone Lighting CP4124-Ci14-}E OC-RAL9005TX, 01 Perdegnan stake pokes shall be: Valmont 21' 4' RTA Pole: 210440TO6T4A1RAL900514ORTCS011013-8K62, O.A.E 3291 Phatselectric Controls Section 329.1112) is deleted and replaced as follows: Photoelectric controls shall be a plug-in Mercer rated to operate on 120 volts, 60 Ha The unit shall consist of a light emotive element connected to necessary control relays. The unit shall be so designed Mat a fellows of any electronic component will energize the lighting cards. The photo all shall be a solid state device whh stable lumon "dues in the temperature range a-55 degrees C W ♦TO degrees C The photo cell shall be mounted externally on top of the luminaire. In a contactor controlled system, the photo all to control the system shall be mounted on the luminaire nearest to Me servicelcontidor cabinet. The photo all shall be capable of swltdting -ON' 1,000 wafts of incandescent load as a minimum. The phoacell shall be rated tar a 20+ War Inde span. e.xma wRwuogrm ewssmwM VERTICAL DATURk CITY OF RENTON, NAVD 88 BENCHMARK. CITY OF RENTON CONTROL POINT NO. 1864 WAS HELD FOR ELEVATION, BEING 19.488 FEET (NAVD88) SP -3 with a bare copper bonding step sized in accordance with Me Plans, specifications and appkiabke came. Ground rods are considered miscellaneous items and all costs are 0 be included with Me system or conductors. Ground straps are also miscellaneous items unless a separate pay item is provided in Me -Schedule of pdcesi 8G20,3(10) Service& Transformer, Intelligent Transportation System Section 8-20.3(10) is revised and supplemented as (allows Paragraph taro is deleted. Paragraph three is deleted. The f slowng is added Power serves shall be single phase 120/240 volt, 3 wire 60 cycle A.C. (street lighting contactor/traffic signal, grounded neutral service) Per City of Renton Standard Details. The Power service paint shall be as noted an the Plans and well be verified by the electrical servicing utility. 8.28. 13 Illuminatlon 3( ( Systems 8-203(13RA Light Standards Search 8-20.3(13)A is deleted and replaced as tallows Light standards shall he handled when leading, unloading, and erecting in such a manner that they will not be damaged. Any pans that are damaged due to the Contractors operations shall be repaired or replaced at the Contractors expense, to the satisfaction of Me Engineer. Light standards shall not be erected on concrete foundations until foundations have set at least 72 hours or attained a compressive strength of 2.400 psi, and shall be raked sufficiently to be plumb after all load has been placed, or as p(hervme directed by Me Engineer. Light Standards shall be credact in accomance with section 8-20.314). Anchor bolts shall extend through the top M1eavy-hex nut two, of threads to the extent Possible Anchor bolts shell be tightened by Me Tum.01-Nut Tightening Method in accordance wit Sections 6-03.3(33) and 8-20.3(4). Anchor bobs damaged after to foundation concrete is placed shall riot be repaired by bending or walling. The Contractor's repair procedure is to be submitted W the Engineer for approval prior W making any repairs. The procedure is W include removing Me damaged portion of Me anchor bolt, coding threatls on Me undamaged ponies to remain, the installation of an approved threaded sleeve not and stud, and reporting Me foundation with epoxy concrete repair. The grout pad shall not extend above Me elevated of the bottom of the bass. vexaNn.l�m apvJ nrgmrf CHECKED FOR COWILIANCE TO CITY BTANDARDB Date Date— Date— SP4 Anchor Base: A one piece anchor base of adequate strength, shape and size shall be secured to Me Inner end of the shaft so Mat Me base shall be capable of resisting at its yield pant Me bantling moment of Me shaft at its yield point. The base shall be provided with four sbded or round holes to receive the anchor bolls. Nut covets shall be provided with each poke. Anchor BOBS: Four steal anchor bolts, as& flttid with two hex nuts and has washers, shall be fumishad with the pole. Anchor hefts shall meet Me requirements of Section 9-06.5(3) and 9-08.5(4). The anchor bolt yield point shall be capable of warning Me bending moment of the pole shaft at its yield point. The Contractor shall assure that all anchor bolts conform to the recommended ASTM specifications M me pole manufacturer ant shall secure and submit be Me City fat approval all manufacturer data on pole bending moment, anchor bolt fabrication data, lest results and any other data Mal may be required to confirm that the anchor bolts meat these specifications. Miscellaneous Hardware: All hardware (bolts, nuts, screws, washes, etc.) needed to complete Me installation shall be stainless steel. I.D. (Identification for poles): The Contractor shall supply and install a combination of 4 - Ttllgits and one letter on each pole, Whether individual lumdaire or signal pole with luminaire. The letter and numbers combination shall be mounted at Me 15 foot level an lie pole facing approaching traffic. Legends shall be added with transparent film, resistant to door "sell and ultraviolet exposure. The decal markets shall be 2 -1a -inch square with yellow reflectorized 2 -inch legend on a black background. The I.D. number will be assigned to each pole at Me end of the contract or project by the Transportation Maintenance Assistant Manager and tooMinated through the City Inspector. Cost for the recalls shall be considered Incidental to Me contract bid. Light standards shall meet the pole detail requirement below and the detail sheets on the approved plan documents. The pole shaft shall be provided With a 4" x 6' flush hand hole near the base and a matching metal cover secured with stainless steel screws or bolts. The pole shall be adjusted far plumb after all needed equipment has been installed thereon. After pole is installed aid plumbed nuts shall be tightened on anchor bobs using proper sa ed sockets o end or box wrenches. Use of fers wrenches or other basis that can Pen r .pipe damage ofine muss. will not be permitted Tools shall foundation M sufficient size to achieve adequate base torquing to the pati. TM1e space betweenpack orconcrete and trovron antl the bottom of the pole base piste shall Must filled with a dry pack monar grout and troweletl to a smooth finish conforming a Me contour of Me pole base plate. NOTE: THE 2014 WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION AND THE CITY OF RENTON SPECIAL PROVISIONS SHOWN ON THIS SHEET SHALL BE CONSIDERED PART OF THESE CONTRACT DOCUMENTS. THE FRONTAGE ILLUMINATION SCOPE OF WORK SHOWN ON SHEETS IL1.01 THRU IL1.09 SHALL BE CONSTRUCTED IN ACCORDANCE WITH THESE WSDOT STANDARD SPECIFICATIONS AND CITY SPECIAL PROVISIONS. IKEA PROPERTY INC dER j 420 ALAN WOOD ROAD B� CONSHOHOCKEN, PA 19428 '• WAS/y C,t CONTACT: DWGHT E. SLATON CONSTRUCTION MANAGER ( P: (610) 834-0180; C. 303-549-4623 (W E: DWGHTSLATONOIKEACOM 15tH �O 2 ENGINEER nIST,. G T TRANSPORTATION TRANSPORTATION ENGINEERING NORTHWEST 3NAL fiq SE 8TH STREET, SURE 200 9 BELLNUE, WA 98004 CONTACT: GLEN DuBREUIL 0��.��'�Qil P: (425) 250-0582; G (206) 295-6776 E: DUBREUILOTENW.COM �TENW IKE Transmportafion Eng�ineenngwNorthWest IJ�4en sw+gry, gmrs CITY OF RENTON MEPARTMENT OF PUBLIC WORKS FRONTAGE ILLUMINATION SPECIAL PROVISIONS REDEVELOPMENT. RENTOI 10 as io T-384721 0 Z O 7 W U 00