Loading...
HomeMy WebLinkAboutR-398725n 00 O M O NET0 n i Ln Z _O H H W cc LL m O N J FIRE STATION IRRIGATION SCHEDULE POP-UP HEAD W/ SWING JOINT RISER SVM MANUFACTIIRER/MODEL ARC PSI GMP+10^/ RADIUS /WrL ® RAINBIRD 1812SAM-PRS30-MPR-5Q 90 30 0.11 5' ® RAINBIRD 1812SAM-PRS30-MPR-5H 180 30 0.22 5' ® RAINBIRD 1812-SAM-PRS30-U8F 360 30 1.16 8' ® RAINBIRD 1812-SAM-PRS30-U8H 180 30 0.57 8' ® RAINBIRD 1812SAM-PRS30-U8Q 90 30 0.29 8' (SJ RAINBIRD 1812SAM-PRS30-U10F 360 30 1.80 10' DWGS RAINBIRD 1812SAM-PRS30-U10H 180 30 0.90 10' 4 RAINBIRD 1812SAM-PRS30-U10Q 90 30 0.45 10' Q RAINBIRD 1812SAM-PRS30-U12F 360 30 2.86 12' W/ RAINBIRD 1812SAM-PRS30-U12H 180 30 1.43 12' RAINBIRD 1812-SAM-PRS30-U12Q 90 30 0.72 12' RAINBIRD 1812SAM-PRS30-U15H 180 30 2.04 15' n RAINBIRD 1812-SAM-PRS30-U15Q 90 30 1.01 15' o RAINBIRD 1812SAM-PRS30-MPR-I5RCS 30 0.54 4'x 15' o RAINBIRD 1812SAM-PRS30-MPR-I5LCS 30 0.54 4'x 15' RAINBIRD 1812SAM-PRS30-MPR-I5SST 30 1.33 4'x 30' FIRE STATION IRRIGATION ABBREVIATIONS FIRE STATION IRRIGATION NOTES 1. ALL IRRIGATION WORK SHOWN IS ALTERNATE#1. 2. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION. THESE LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MANUFACTURERS RATED GPM FOR EACH NOZZLE. 3. LOCATE AUTOMATIC CONTROL VALVES IN PLANTING AREAS AT POINT OF EASY ACCESS. OWNER'S REPRESENTATIVE TO REVIEW &APPROVE FINAL LOCATION OF ALL QUICK COUPLERS & AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 4. CONTRACTOR SHALL COORDINATE IRRIGATION EQUIPMENT WITH PLANT MATERIAL, TO AVOID CONFLICTS, SPRAY BLOCKAGE & ANY OTHER ITEMS DEEMED APPROPRIATE BY THE OWNER'S REPRESENTATIVE. 5. PSI IS APPROXIMATELY 98 PSI AT ELEVATION 210' PER CITY OF RENTON PRE -APPLICATION MEMORANDUM DATED 18 MAY, 2017. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EX PSI. NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES BETWEEN THE DESIGN PSI & EX PSI PRIOR TO PROCEEDING WITH WORK. 6. SYSTEM DESIGNED TO 30 PSI (SPRAY HEADS). 7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT MATERIALS OR SITE CONDITIONS. 8. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS WITH GENERAL CONTRACTOR. 9. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & REVIEWED BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. LOCATE SLEEVES ON DIMENSIONED "AS -BUILT' DRAWING TO ALLOW FOR FUTURE LOCATION & USE. ON "AS -BUILT" DRAWING, MAINLINE SHALL BE DIMENSIONED FROM ROADWAY CURB @ 30' OC TO ALLOW FOR FUTURE LOCATION. 10. CONTRACTOR TO AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM IN FIRST SEASON. 11, PROVIDE VARIABLE ARC NOZZLES WHERE NECESSARY PER FIELD DIRECTION TO AVOID OVERSPRAY ON PAVED SURFACES AND BETWEEN PLANTING AND LAWN ZONES. FIRE STATION IRRIGATION LEGEND SYM DESCRIPTION 2 LATERAL LINE WITH PIZE SIZE (SCH 40 PVC), L2.03 SEE PIPE SIZING LEGEND FOR SIZE 2 ------- 2" MAIN LINE (SCH 40) L2.03 2 - IRRIGATION SLEEVE (SCH 40 PVC) L2.03 1C POINT OF CONNECTION L2.01B IRRIGATION CONTROLLER -TORO SENTINEL q CENTRAL CONTROL SYSTEM SB-12-WS1-U; L2.02 © PROVIDE ONE (1) SHHR (SENTINEL HAND HELD REMOTE) WI BATTERY ❑N 1"WATER METER, SEE CIVIL SHEET C4.00 L2.02 2 OO BALL VALVE - NDS, SIZE TO MATCH PIPE SIZE 33 A 1"QUICK COUPLING VALVE W/ KEY L2.03 & HOSE SWIVEL RAINBIRD 44 -LRC 5 ® TORO P220, 1Y" MASTER CONTROL VALVE L2.02 CIRCUIT #1 # GPM 1" VALVE SIZE q RAINBIRD FEB AUTOMATIC CONTROL L2.03 VALVE WI BALL VALVE (SPEARS MVPBV6S) 5 TORO TFS-150 FLOW SENSOR L2.02 1.5" DOUBLE CHECK VALVE, SEE CIVIL SHEET C4.00 3 2" PRESSURE REDUCING L2.02 0 VALVE ZURN WILKENS 500XL / H ` DETAIL IDENTIFICATION L-1 SHEETIDENTIFICA I ION • PROPERTY LINE ------. FUTURE ROW LINE - - -Z15- - - PROPOSED SITE CONTOURS, SEE CIVIL m EX SITE CONTOURS, SEE CIVIL PIPE SIZING LEGEND SYM DESCRIPTION 3/4" 1-1/2" 2" PRESSURE REDUCING VALVE SEE CIVIL DWGS \ FLOW SENSOR I J MASTER CONTROL VALVE I 1 .5" DOUBLE CHECK 1VE ASSEMBLY QUICK COUPLER I I1" WATER PVC MAINLINE METER IRR SYSTEMM DOWN STREAM 1 I L ------ FIRE STATION IRRIGATION 1 f"VIIV I l NOT TO SCALE 1 CONSTRUCTION PERMIT I CD 1 1/29 1 DWK I SI 2 CONSTRUCTION PERMIT REVISION CD 2/12 DWK m a 1'=20' NMI wo'"" III `" D. KooNrs ONE 14Z = C. DIGGINS DATUM J. HDIAT IOU Z IF NOT ONE INN NO. REVISION BY DATE II > J. VOND M""m'm"a. Fcl09AVI:C\I*1111 OCITY OF RENTON Planning/Building/Public Works Dept. In ■ � HBB LANDSCAPE ARCHITECTURE 215WESTWE AVENUE NN I 2V8.882. 3051 ph" 8EI WA 831M MN8232i5Y„ IN COMPLIANCE WITH CITY OF RENTON STANDARDS JRRENT PLANNING cclose 02/15/2018 FIRE STATION 15 1404 N 30TH STREET RENTON, WA 98056 IRRIGATION SCHEDULE, LEGEND, DETAIL, ABBR & NOTES 2/12/18 M O M Ln O O I\ r X N M O O O O 1 r Q J O Nt O 0 O I z O Q (n W m LL PERCENT MFRS MANUFACTURERS & AND MIN MINIMUM @ AT OC ON CENTER #/NO NUMBER NDS NDS INC ABBR ABBREVIATIONS POC POINT OF CONNECTION ARCH ARCHITECTURAL PVC POLYVINYL CHLORIDE It CENTER LINE PSI POUNDS PER SQUARE INCH COR CITY OF RENTON S SLIP DIA DIAMETER SCH SCHEDULE DWGS DRAWINGS SPEC(S) SPECIFICATION(S) EX EXISTING T THREAD GPM GALLONS PER MINUTE TYP TYPICAL IRR IRRIGATION W WIDTH L LENGTH W/ WITH MAX MAXIMUM FIRE STATION IRRIGATION NOTES 1. ALL IRRIGATION WORK SHOWN IS ALTERNATE#1. 2. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION. THESE LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MANUFACTURERS RATED GPM FOR EACH NOZZLE. 3. LOCATE AUTOMATIC CONTROL VALVES IN PLANTING AREAS AT POINT OF EASY ACCESS. OWNER'S REPRESENTATIVE TO REVIEW &APPROVE FINAL LOCATION OF ALL QUICK COUPLERS & AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 4. CONTRACTOR SHALL COORDINATE IRRIGATION EQUIPMENT WITH PLANT MATERIAL, TO AVOID CONFLICTS, SPRAY BLOCKAGE & ANY OTHER ITEMS DEEMED APPROPRIATE BY THE OWNER'S REPRESENTATIVE. 5. PSI IS APPROXIMATELY 98 PSI AT ELEVATION 210' PER CITY OF RENTON PRE -APPLICATION MEMORANDUM DATED 18 MAY, 2017. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EX PSI. NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES BETWEEN THE DESIGN PSI & EX PSI PRIOR TO PROCEEDING WITH WORK. 6. SYSTEM DESIGNED TO 30 PSI (SPRAY HEADS). 7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT MATERIALS OR SITE CONDITIONS. 8. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS WITH GENERAL CONTRACTOR. 9. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & REVIEWED BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. LOCATE SLEEVES ON DIMENSIONED "AS -BUILT' DRAWING TO ALLOW FOR FUTURE LOCATION & USE. ON "AS -BUILT" DRAWING, MAINLINE SHALL BE DIMENSIONED FROM ROADWAY CURB @ 30' OC TO ALLOW FOR FUTURE LOCATION. 10. CONTRACTOR TO AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM IN FIRST SEASON. 11, PROVIDE VARIABLE ARC NOZZLES WHERE NECESSARY PER FIELD DIRECTION TO AVOID OVERSPRAY ON PAVED SURFACES AND BETWEEN PLANTING AND LAWN ZONES. FIRE STATION IRRIGATION LEGEND SYM DESCRIPTION 2 LATERAL LINE WITH PIZE SIZE (SCH 40 PVC), L2.03 SEE PIPE SIZING LEGEND FOR SIZE 2 ------- 2" MAIN LINE (SCH 40) L2.03 2 - IRRIGATION SLEEVE (SCH 40 PVC) L2.03 1C POINT OF CONNECTION L2.01B IRRIGATION CONTROLLER -TORO SENTINEL q CENTRAL CONTROL SYSTEM SB-12-WS1-U; L2.02 © PROVIDE ONE (1) SHHR (SENTINEL HAND HELD REMOTE) WI BATTERY ❑N 1"WATER METER, SEE CIVIL SHEET C4.00 L2.02 2 OO BALL VALVE - NDS, SIZE TO MATCH PIPE SIZE 33 A 1"QUICK COUPLING VALVE W/ KEY L2.03 & HOSE SWIVEL RAINBIRD 44 -LRC 5 ® TORO P220, 1Y" MASTER CONTROL VALVE L2.02 CIRCUIT #1 # GPM 1" VALVE SIZE q RAINBIRD FEB AUTOMATIC CONTROL L2.03 VALVE WI BALL VALVE (SPEARS MVPBV6S) 5 TORO TFS-150 FLOW SENSOR L2.02 1.5" DOUBLE CHECK VALVE, SEE CIVIL SHEET C4.00 3 2" PRESSURE REDUCING L2.02 0 VALVE ZURN WILKENS 500XL / H ` DETAIL IDENTIFICATION L-1 SHEETIDENTIFICA I ION • PROPERTY LINE ------. FUTURE ROW LINE - - -Z15- - - PROPOSED SITE CONTOURS, SEE CIVIL m EX SITE CONTOURS, SEE CIVIL PIPE SIZING LEGEND SYM DESCRIPTION 3/4" 1-1/2" 2" PRESSURE REDUCING VALVE SEE CIVIL DWGS \ FLOW SENSOR I J MASTER CONTROL VALVE I 1 .5" DOUBLE CHECK 1VE ASSEMBLY QUICK COUPLER I I1" WATER PVC MAINLINE METER IRR SYSTEMM DOWN STREAM 1 I L ------ FIRE STATION IRRIGATION 1 f"VIIV I l NOT TO SCALE 1 CONSTRUCTION PERMIT I CD 1 1/29 1 DWK I SI 2 CONSTRUCTION PERMIT REVISION CD 2/12 DWK m a 1'=20' NMI wo'"" III `" D. KooNrs ONE 14Z = C. DIGGINS DATUM J. HDIAT IOU Z IF NOT ONE INN NO. REVISION BY DATE II > J. VOND M""m'm"a. Fcl09AVI:C\I*1111 OCITY OF RENTON Planning/Building/Public Works Dept. In ■ � HBB LANDSCAPE ARCHITECTURE 215WESTWE AVENUE NN I 2V8.882. 3051 ph" 8EI WA 831M MN8232i5Y„ IN COMPLIANCE WITH CITY OF RENTON STANDARDS JRRENT PLANNING cclose 02/15/2018 FIRE STATION 15 1404 N 30TH STREET RENTON, WA 98056 IRRIGATION SCHEDULE, LEGEND, DETAIL, ABBR & NOTES 2/12/18 M O M Ln O O I\ r X N M O O O O 1 r Q J O Nt O 0 O I z O Q (n W m LL