HomeMy WebLinkAboutR-396217NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N co O co O 96"0 CMP DETENTION PIPE AT 0.00% 0 LENGTH VARIES, SEE PLAN w � TOP OF PIPE EL-399.06 ,399-9� 36"0 ACCESS MANWAY, TYP 36"0 ACCESS MANWAY, TYP FINISHED GRADE VARIES, SEE PLAN AND PROFILE -\ TOP OF LIVER 398.73 100 YR WSEg398.54 50 YR WSE= -4 398.54 -______________________________ - _________________________ 10 YR WSE­3� 398.50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 YR WSE=44�- - 397.67 BEGIN LIVE STORAGE EL­3�391.49 - -_-- ------------------------------ - __________________ w BOTTOM OF PIPE EL�1-9� Ir 391.06 0.5 SEDIMENT STORAGE 36"0 CMP ACCESS LADDER, TYP 36"0 CMP 36"0 CMP -/ Q DETENTION PIPE - TYPICAL PROFILE U 2 L.F. 36 0 SD @ 0.00% SCALE: 1"=10' J Q ACCESS MANWAY PER COR 0 STD PLAN 235.10, w FINISHED GRADE VARIES, DETENTION TANK ACCESS 0- SEE PLAN AND PROFILE DETAIL, SEE PLAN FOR LOCATIONS, TYP 399 06 Z TOP OF PIPE EL=39 6� O TOP OF LIVE =38-398.73 0.5' FREE BOARD 1­_ 100 YR WSE�398.54 _ _ _ _ _ _ _ _ z 50 YR WSE�398.54 w 10 YR WSE=2'398.50 �� - ---- - - - -- - - - - - - Ir 2 YR WSE=39 397.67 E 0 co O I CD O N U 0) 0) O n on 3 J 0- I to 1 Q r r7 m I Q / m c 0 0 T E E 0 v 0 0 0 U Q C 0 Q) to i r,0 O N i C .3 0 0 BEGIN LIVE STORAGE EL=39�-56 391.49 391.06 BOTTOM OF PIPE EL=391.88 0.5' SEDIMENT STORAGE 36"0 CMP DETENTION PIPE - TYPICAL SECTION optional parallel tank ---------- 1 _ access dsers (max spacing shown below) inlet pipe (backup systems, where allowed) 2' min A O control structure SCALE: 1"=5' FOR 2 OR MORE ADJACENT PIPES IF- �- 7 1 I min. diameter same as inlet pipe A flow J 36" J Oinlet pipe (flow through) type 2 CB required access risers for flow, through system only PLAN VIEW NTS "Flow -through" system shown solid. Designs for "flow backup" system and parallel tanks shown dashed 2" min. diameter air vent pipe welded to tank (required if no access riser on tank) 50' max 100' max access risers ON sediment storage r� 36" min. size as required 2' min diameter (typ) control structure (PROP-Tshown) SECTION A -A min. 54" dia. Type 2 CB NTS "Flow -through" system shown solid. NOTE: All metal parts corrosion resistant. Steel parts galvanized and asphalt coated (Treatment 1 or better) zY + �► PUBLIC WORKS TYPICAL DETENTION TANK STD. PLAN - 235.00 f, NT DEPARTMENT MARCH 2O08 AS-BOIL T DRAWINGS 4 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 8' 0 DETENTION TANK PER COR STD PLAN 235.00 NOTE: CMP 10 GAGE OR BETTER. standard type 2-60" clam. CB concrete top slab 36" CMP riser -, standard locking compacted pipe bedding M.H. steps 12" O.C. weld or brit standard M.H. steps PLAN NTS SECTION NTS NOTES: 1. Use adjusting blocks as required to bring frame to guide. 2. All materials to be aluminum or galvanized and asphalt coated (Treatment 1 or better). 3. Must be located for access by maintenance vehicles. 4. May substitute WSDOT special Type IV manhole (RCP only). DETENTION PIPE SUMMARY CHART STORM LIVE STORAGE VOLUME (CF) RELEASE RATE (CSF) EVENT REQUIRED DESIGNED AS -BUILT REQUIRED DESIGNED AS -BUILT 2 YR 19,555 19,962 0 0.041 0.036 0.036 10 YR 22,267 22,827 22,267 0.074 0.058 0.0573 100 YR 22,352 22,894 22,352 0.098 0.093 0.09L2L] NOTE PI F1i-F VERIFY/UPDATE 1. SEE APPROVED BUILDING PERMIT 317004182 FOR ADDITIONAL I THESE NUMBERS CONSTRUCTION DETAILS FOR DETENTION PIPE INSTALLATION. frame locking lid (marked "DRAIN") mounted over 24" diam. eccentric opening maintain 1" gap between dtom of slab & top of .cr - provide pliable isket to exclude dirt riser, 36" diam. min., same material & gage as tank welded or fused to tank detention tank PUBLIC WORKS DETENTION TANK STD. PLAN - 235.10 DEPARTMENT ACCESS DETAIL MARCH 2O08 1 th A N N 1 T4'r- o C! A Ry Surveying 5 LD Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com 0 1 AS -BUILT DRAWINGS NO. REVISION 0 removable watertight coupling or flange frame &solid cover marked "DRAIN' with locking bolts 2" min. see note 3 elevation per plans 1' min. under pavement 16" max. g" T vertical bar � T gratefor max. 6" min. design W.S. secondary inlet v plate welded to elbow with orifice as specified elbow restrlctor, see detail ELBOW pipe supports handholds, steps or RESTRICTOR see Nole 6 ladder DETAIL 1.5 x D min. 2' min. T cutlet pipe inlet D see notes 1 & 1 dipa 2 shear gate with control invert and elevation rod for cleanoutPorein per plans -N 12" (rod bent as required for vertical alignment 12" with cover) o .E welded restrictor plate - 12" with orifice diameter as IF specified (not needed if for spill control only) /\ SECTION A -A 2' min. clearance to any portion of frop-T including elbows NOTES- A 1. Use a mimimum of a 54" diameter type 2 / catch basin. 2. Outlet Capacity: 100-Year developed peak flow. 3. Metal Paris: Corrosion resistant. elbow resbictor Non -Galvanized parts perferred. see detail Galvanized pipe parts to have asphalt treatment 1. 4. Frame and ladder or steps offset so: A. Cleanoul gate is visible from lop. B. Climb -down space is dear of riser and cleanout gate. C. Frame is clear of curb. 5. If metal outlet pipe connects to cement concrete pipe: outlet pipe to have smooth O.D. equal to concrete pipe I.D. less 4". 6. Provide at least one 3" X .090 gage support bracket anchored to concrete wall. (maximum T-0" vertical spacing) 7. Locate elbow restriclor(s) as necessary to provide minimum clearance as shown. S. Locate additional ladder rungs in structures used as access to tanks and vaults to allow access when catch basin is filled with water. A angle as necessary see note 7 addtional ladder rungs 2' min (in sets) to allow access to tanks or vaults when catch is filled with water �ZY � PUBLIC WORKS FLOW RESTRICTOR STD. PLAN - 237.00 DEPARTMENT OIL POLLUTION CONTROL �FN C TEE MARCH 2O08 12" 0 TO CB-1 REMOVABLE WATERTIGH COUPLING OR FLANGE 2" MIN. TO ELBOW 6" MIN. MAX PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED ELBOW RESTRICTOR RISER EL=398.73 RISER rl =zno �n D 1 /2" 0 ORIFICE r- IE=398.22 1-1/8"0 ORIFICE IE=397.28 4" ELBOW RESTRICTO SEE DETAIL, TYP I DISCHARGE TO CB-1 1 IE=391.36 12"� PIPE SUPPORTS - SEE NOTE 4 RESTRICTOR PLATE 1 /2"0 ORIFICE IE=389.50 EL=387.50 SEE DETAIL, ` v vDETAIL, TYP" PLAN 54"0 MIN ELEVATION CONTROL STRUCTURE CB-2 SCALE: 1"=2' TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. MEV 12-13-18 SURVEYED: SCALE: LDC VERTICAL: NAVD 1988 AS NOTED DESIGNED: HORIZONTAL: NAD 1983/1991 C TY O MEV RENTON ENTON NC ONE INCH DATU M • CHECKED: MEV AT FULL SCALE Plan ning/Building/Public Works Dept. IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY MEV ROM DETENTION PIPE SD C'7 00 Cfl O O T C'7 O O O O T Q J z 50 YR WS LO EL=398.47 O O O O I T n� FROM CB-3 1 FROM DETENTION PIPE IE=391.49 36 SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) M N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 STORM DRAINAGE DETENTION PLAN R-396217 OC U Q UU DATE: C^ FIELDO00 .- O 8 - 1 7 ��♦♦ PAGE: O DRAWING NO: SD-01 Z SHEET: 7F: 17 23