Loading...
HomeMy WebLinkAboutS-396203420 E 0 I m 0 N d5 0 O 0 3 rc m I Q r r� m I Q i 3 0 0 T E E 0 Q) 0 a U a a a) rr i 0 N i a_ 0 0 NE 114 OF THE SW 114 AND SE 114 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON A CROSSING #1 STA. 0+17.74, 7.94' RT. 12" SD IE=391.64 8" SS CROWN=389.11 SEPARATION=2.53' CROSSING #2 STA. 0+24.98, 7.94' RT. 10" DI WA IE=394.21 8" SS CROWN=389.67 SEPARATION=4.54' I � - ...-.._... --• SS S_0.07T1 6g EASEMENT CROSSING #3 STA. 1 +23.31, 21.98' RT 8" SD IE=400.88 8" SS CROWN=399.01 SEPARATION=1.87' FINISHED GRADE AT SEWER ALIGNMENT CL EXISTING GRADE ATE I SSMH-1346-03, STA. 1 +09.29, 7.97' RT. R►M= 403.31 CROSSING #4 STA. 1 +23.24, 30.40' RT. 8" SS IE=403.75 8" SD CROWN=402.25 SEPARATION=1.50' EX-SSMH IE= 395.41 (T 1 IN (NE) VERIFY INVERT ELEV IE= 395.31 (TO OUT S) ;- PRIOR TO CONSTRUCTION) IE=395.41 STA. 15+36.42, 6.21' RT. (172ND ST) SSMH-1346-02, RIM=390.63 STA. 0+64.29, 7.95' RT. IE=379.28 IN (E) RIM=400.38 IE=379.18 �8"O� 8"�OUT (W) IE= 392.16 0 15 IE= 392.0680 _ 161 -LF: _Ir PVC 29 LF. 8' SS S=0.1000 SSMH-1346-01, CUT IN j STA, 16+89.36, 4.56' LT. ' RIM=397.92 SSMH-1346-04, IE= 386.70 IN (N STA. 1 +29.49, 28.29' RT. IE=386.60 �8::O� 8"0OUT �S) - RIM=405.64 85 LF. 8" PVC IE= 398.41 TO IN (N IE= 398.31 �ErO� OUT �SW) E(-SSMH SEWER ALIGNMENT VERIFY INVERT ELEV SCALE: HOR: 1"=20' 34 LF. Er SS S=0.0100 _. _. PRIOR TO CONSTRUCTION) �- VER: 1"=10' STA. 17+82.23, 3.56' RT. (72ND ST) RIM=400.75 IE= 391.23 PVC IN (S) IE=391.13 �6::O 8"0 PVC) OUT (N) O rn J Z \\ PARCEL � O rnm #JJc3 fUJ�2c3-J z � s o -10' SD ESMT pq 0' CITY EMERGENCY --- ACCESS ESMT 111 `7­7 L---------- _ _- - - _ SSMH-1346-03 --- 1+00 M 6', SEE C1-3, PG. 51- 16 WATER & - - ROPOSED SEWER ESMT WATER SSMH-1346-02 I 4.5' R/W DEDICATION I 6" MIN ®2% MIN - i C.O. IE=404.00 COTTAGE D FF ELEV=410.50 SSMH-1346-04 15 LF. 8" SS GREASE INTERCEPTOR INTAKE STA. 1 +77.87, 28.48' RT. RIM=408.00 IE= 399.73 (8"0) IN (N) GREASE INTERCEPTOR OUTFALL STA. 1 +68.87, 28.47' RT. RIM=408.00 IE= 399.40 (8" 0) OUT (S) 5 LF. 8r SS S=0.1100 SSMH-1346-05, STA. 1 +64.04, 28,38' RT. RIM=407.11 IE=398 85 TO IN (N) IE= 398.75 8"O OUT ((S) IE=39885 6"0 IN (E) TAIX PARCEL 420 400 380 ITA STORM DETENTION PIPE, TYP --------------------------------------------------, I --__ �- �----- O SSMH-1346-05 PRIVATE GREASE- ._ ti ------ 60 w I o w l 3 I I� 3 w - -._I -- - ----- 1 L --- r 6" MIN 2% MIN C.O. IE=404.00 GREASE INTERCEPTOR OUTLET COTTAGEA FF ELEV=410.50 6" MIN ® 2% MIN C.0 IE=404.00 GREASE INTERCEPTOR INTAKE I I I I I I 1 I I r_ I 1 I 1 I 1 1 1 I 1 I I I 1 I I SURVEY INFORMATION LEGAL DESCRIPTION LOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. TOGS HER WITH: THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. VERTICAL DATUM - NAVD-W NORTH AMERICAN VERTICAL DATUM-1988 BENCHMARK PRWECT BENCHMARK.• FOUND REBAR AND CAP EMW LS144651(AS SHOWN ON MAP) ELEVATION = 409.72 FEET PROJECT BENCHMARK.• CITY OF RENTON MON11640 3" BRASS DISC STAMPED "KING COUNTY SURVEY MONUMENT" IN CASE FOUND CO-ORDS: N=170649.17 E=1305835.94 ELEVATION = 465.87 FEET BASIS OF BEARING THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N O1'4332" E EQUIPMENT & PROCEDURES METHOD OF SURVEY.' SURVEY PERFORMED BY FIELD TRAVERSE INSTRUMENTATION.• LDCA TCRA 1105 ROBOTIC ELECTRONIC TOTAL STATION PRECISION.• MEETS OR EXCEEDS STATE STANDARDS WAC 332-130-090 BASIS OF BWING.• THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01'4332" E. SIDE SEWER SERVICE TABLE DIST. TO SERVICE COTTAGE (FROM DOWNSTREAM SERVICE LENGTH TO IE AT MAIN FINISHED STUB DEPTH AT SLOPE MANHOLE) STUB CONNECTION FLOOR ELEVATION STUB A-1 0+ 20 399.73 410.50 404.00 6.50' 21.3X A-2 0+ 1 20 398.85 410.50 j 404.00 6 50' 25 7x 8 0+ 61 401.60 410.50- -404.5 i 6.' 4.87i % - -. - 0+ C 46 401.60 410.50 ; 404 6 5' S 27i D 0+ - 27 395.41 410.50 404 6.5' 31.8x 0 w > w 60 SCALE: 1" = 20' MINI 20' 0 20' 40' LEGEND STORM PIPE DRAIN PIPE ------ SEWER PIPE WATER PIPE P POWER PIPE G-- GAS PIPE S EX -SEWER O CLEAN OUT m396203 TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATEL Y TO THE ATTENTION OF THE ENGINEER. PLAN REVIEW # 04-1346 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center -a-, mmmmmmmm i-, i>' �'- � � a,- Q o cr_ r-� _�� CN a Q I cD c0 CV I 1- I "I- T N Z Z C) N o E3� I 00 (n z O C/) z m� N Z I Cn z m I N V) z m 0 o=� L 0 0 m 0 M o m 0 m 0 f WQ w Y L'-'JiJ u Y W U U Y LLIJ U Y W U N U Z QQ cn O cn O w a- V) O V) O= a W = O V)cn CD � L-jN O cn O cn U o W a W a W a-a� > a W a- W a- J W u- ^ 00 Q N "' 1 "' 'n ^ a' N cal c 0000 > c on cn ua d E 0 2. 0 v 0 �2s z N vs S 3 vQ <� o �3 U Z Z 02 0 ZO J W W O W Uj V) w w C) Z W _J Q 3: W W a v WZ 0 � O o � Z �o / Ujv � E. VILl�A wasg��c O� 0�)� p �' 40908 •, ISTI;RFO SSf0NAL JOB NUMBER: 16-137 DRAWING NAME: 16137A-SS-PP DESIGNER: MEV DRAFTING BY: NC DATE: 5-25-17 SCALE: 1 " = 20' JURISDICTION: SOOS CREEK LASE MAP C2 DRAWING: C-136 SHEET 2 OF 8