Loading...
HomeMy WebLinkAboutT-396201NE 114 OF THE SW 114 AND SE 114 OF THE NW 114, SEC 29, T WN 2 9, R GE 5 E, Et I � i ;# I (- WER POLE ± S 4 El AND 11 2' INL OF OP2TY tINE I _r I +---y 4 I it s __.=--W----_ - --------------- - - - - - - - - - - - - FIRE HYDRANT LIES 0 t N 4F PROPERTY LINE� 6, 5 1 3 I 4 00 I 1+00 O "� q --==c- S ---i-G-----G-----G- 18+00 SC 172ND 19+00 _ _ __ --�- ;Ai 2 REVISED PER CITY COMMENTS 4 REVISED PER CITY COMMENTS 5 REVISED PER CITY COMMENTS Electrical Consultants, Inc. 6 REVISED PER CITY COMMENTS 19015 36th Avenue West, Suite E CONFORMED SET Lynnwood, Washington 98036 Phone (425) 775-1799 FAX (425) 774-9870 NO REVISION P:vl I I 1 KING COUNTY, WASHING TON PLAN SYMBOLS LEGEND: N TYPE 1 JUNCTION BOX, WITH CONCRETE PAD — PVC CONDUIT, UNDERGROUND ® ELECTRICAL SERVICE CABINET ® SECONDARY SERVICE BOX ® WIRE NOTE ® CONSTRUCTION NOTE ® POLE NUMBER i NEW PEDESTRIAN LIGHT POLE, LED NEW ROADWAY LIGHT POLE, LED EXST 75KVA XFMR -- W GENERAL NOTES: 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE FOR THE GRAPHIC REPRESENTATION ONLY AND FINAL LOCATIONS SHALL BE CONFIRMED WITH THE CITY OF RENTON INSPECTOR AND/OR PUGET SOUND ENERGY. 2. ALL WORK SHALL BE IN ACCORDANCE CITY OF RENTON STANDARDS AND SPECIFICATIONS. 3. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE INSPECTOR FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 4. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 72 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 5. EXISTING FEATURES WITHIN CITY RIGHT-OF-WAY TO REMAIN UNLESS OTHERWISE NOTED. 6. CONTRACTOR TO REPLACE EXISTING ELEMENTS IN KIND WHEN DAMAGED DURING CONSTRUCTION. 7. REFER TO CIVIL CONSTRUCTION PLANS FOR EXACT STREET LIGHT LOCATIONS. 8. CONTRACTOR SHALL COORDINATED FINAL POWER CONNECTION TO STREET LIGHT SERVICE CABINET WITH PSE. CONSTRUCTION NOTES Ol INSTALL NEIGHBORHOOD STREET PEDESTRIAN LIGHT FIXTURE, POLE AND CONCRETE FOUNDATION PER COR STANDARD PLAN 116.1. ASSOCIATED JUNCTION BOX AND CONCRETE PAD PER DETAILS ON SHEETS ES-02 AND ES-03, AND LUMINAIRE POLE SCHEDULE. 20 INSTALL ARTERIAL STREET DECORATIVE ROADWAY LIGHT FIXTURE AND POLE PER STANDARD PLAN 117.1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEETS ES-02 AND ES-03, AND LUMINAIRE POLE SCHEDULE. O3 INSTALL ELECTRICAL SERVICE CABINET PER DETAILS ON SHEET ES-03, REFER TO SCHEDULE FOR LOCATION ALONG 108TH AVE. SE SHOWN AT APPROXIMATE STATION 10+65, 31.07' LT. COORDINATE WITH PSE FOR SERVICE CONNECTION. LABEL BACK OF CONTACTOR WITH ADDRESS LOCATION, USE 1" LETTERS. OINSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD "B". PAD SHALL BE MODIFIED SO THAT JUNCTION BOX SITS AGAINST SIDEWALK. O PROVIDE NEW LED STREET LIGHT HEAD ON EXISTING UTILITY POLE BEING RELOCATED. REUSE EXISTING ARM. CONNECT AND PROVIDE POWER FROM NEW STREET LIGHT SERVICE CABINET. PROVIDE LEOTEK - GREEN COBRA ROADWAY LUMINAIRE. CAT NO. GC1-60E-MV-NW-2-GY-700 O STUB SPARE CONDUIT TO PROPERTY LINE OR END OF SIDEWALK IMPROVEMENT. 07 CONTRACTOR TO PROVIDE TRENCHING AND BACKFILL ACROSS 108TH AVE SE. PER PSE STANDARD #6750.6500. COORDINATE EXACT ROUTE WITH PSE. LUMINAIRE POLE SCHEDULE POLE LOCATION * POLE POLE LOCATION STATION OFFSET LED LAMP MAST ARM MOUNTING STANDARD NO. ID. LAT. (N) LONG. (W) (FEET) WATTAGE (FEET) HGT.(FEET) PLAN # O5015CI35(ST) 5016B60 PED 47.449331 122.197178 108TH AVE SE 11+95 32.05' LT 135/60 10'/4' 35/14' 117.1 O5017C135(ST) 5018860 PED 47.449044 122.197101 108TH AVE SE 10+99 32.05' LT 135/60 10'/4' 35'/14' 117.1 O 108TH AVE SE (EXISTING POLE) 10+54 25,09' LT 130LED - 35 - ® 5019A44 47.448957 122.197302 SE 172ND ST. 19+07 21.06' RT 44 NA 14' 116.1 O 502OA44 47.448944 122.197605 SE 172ND ST. 18+20 21.06' RT 44 NA 14' 116.1 © 5021A44 47.448907 122.197971 SE 172ND ST. 17+33 21.D6' RT 44 NA 14' 116.1 O 47.448952 122.197133 108TH AVE SE (SVC CABINET) 10+65 31.06' LT 20 00 8" D.I. --WA- MAW � c- I I v Z w 3G-----G----_ - N - SIG W CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION 9-21-17 SLWAuLOC MEV 11-13-17 12-15-17 Denim. RAD 2-07-17 DWm 3-16-18 aeM �A BY DATE APPR I A * FINAL POLE LOCATIONS TO BE DOCUMENTED AT TIME OF CONSTRUCTION. UTILITY CONTACTS: PUGET SOUND ENERGY - POWER BRAD ELKIN - bardley.elkin®pse.com PROJECT MANAGER PHONE: 425-495-6489 UNDERGROUND UTILITY NOTE YOU MUST CALL 1-800-424-555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCAVATION WHERE ANY UNDERGROUND UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN BEARING SUBSTANTIAL REPAIR COST. SCALE: 1 " = 20' -0" EAU NO 103/101 ONE NCH DATUM AT FULL SCALE IF NOT ONE MCH SCALE ACCORDNGLY WIRING SCHEDULE No. 0 CONDUIT SIZE CONDUCTORS 1 2" PVC (SCHEDULE 40) 2-#8, 1-#8 GND (GREEN) 2 2" PVC (SCHEDULE 40) 2-#8, 1-#8 GND (GREEN) 3 2" PVC (SCHEDULE 40) 2-#8, 1-#8 GND (GREEN) 3-#14 PHOTOCELL 4 2. PVC (SCHEDULE 80) SPARE (TO PROPERTY LINE) 5 2" PVC (SCHEDULE 80) PSE POWER / co/� (0 O 1 T X u V IN COMPLIANCE WITH CITY OF RENTON STANDARDS � CITY OF RENTON SPECIAL CARE COMMUMI TY, LL C RENTON RENTON SPECIAL CARE COMMUMI TY 17033 108TH AVE SE, RENTON, WA 98055 Planning/Building/Public Works Dept. STREET LIGHTING PLAN T-396 V J _Q V 4j v1 02-05-18 FEIDDOIL• Z C) ES-01 z 1 OF: 3 201