Loading...
HomeMy WebLinkAboutT-396203N Cfl M T V 0 rr I-- W LU U Q U 1l VJ Z 0 F— Z � Lij LL T NE 714 OF THE SW 114 AND SE 7/4 OF THE NW 714, SEC 29, TWN 29, RGE 5 E, I , I i f , �f�f f W f Ij I Z f r i � O i f Q i 1 cf, f D=3 Dz=o PUBLIC WORKS SERVICE CABINET 81D. PLAN - 122.1 +I J+ DEPARTMENT WITHOUT BBS AN] DIAMETER = 7/8" 4- 7 /8"� 1/4" LOAD FUSE,, LINE 1/4' CU-TING RINGS FUSE KIT EPDXY AFILLL INLINE SPLICE ConvV CII I SPLICE KIT FUSE KIT & SP110E 1UT DETAILS ADOPTED CITY OF RHIrON • ��` STANDARD PLANS LOT DATA: 04/04 t�n DWG. NAME:J013 SP PAGE: JO13 iA TEST SWITCH TERMINAL BLOCK — STREET LIGHTING CONTACTOR CABINET WIRING SCHEMATIC TYPE III SERVICE 120/240 VOLT MOUNTED ON NEAREST LUMINAIRE TO GROUND ROD WIRING COLOR CODE A. WHITE JACKE - (NEUTRAL) B. BLACK JACKET (LINE) C. GREEN JACKET (GROUND) p. RED JACKET (LOAD) _. GREEN OR BARE WIRE (GROUND) O� PUBLIC WORKS STREET LIGHTING CONTACTOR STD. PLAN - 123 DEPARTMENT CABINET SCHEMATIC �fj1w NOTES: All dimensions are minimum. Exact configurations vary among different "manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 4000PS concrete is allowed if box reinforcement consists of 5 X 6 - W3 k W3 welded wire fabric weided to the frame When noted in the contract Type 2 and Type 3 Boxes sholl oe provided with 12" deep extension boxes When noted in the contract. Type 2 Boxes sholl be provided with a 110' X 27 1/2' 10 gage divider plate complete with fasteners. Non -concrete Boxes may be submitted for approval. Evaluation will include on H-20 Load Test JUNCTION BOX DIMEN51CiN TAOU r-- -6 paw ITEM D4K T, TYPE 1 T}PE Z h Esox Outside len th 22 22 33 Box Outside Mdth 17 1 ? 2t22 Box inside L th IS 19 Box Inside Width 13 14 Lid Len tl- 1$ 18 2Lid Width 13 13 Box DB #h 12 12 12 Lid & Frame th 5 16 5 16 5 16 Wr1I Thickness MFlln. 1 1 2 1 1 2 1 1 2 Mtfl ti Rail fdrCEfilltfit W- 3 'W- 215 W-- 2. S Le end Sae Detai See Detail See Detttil • ITEM MATERIALS Box WN P9 concrete See t�rte9 Frame Diamond Note Steel - A786 Lid Support 1 Al6 Sled L a T. - AS Lid Dislmond Note Steel - A786 iAnchors I Steel Wife or Tee Plate iRmforament I ASTM A-82 Steel -kPALVAN{GtU Slttl_ LEGEND DETAIL (Bark L) r1sai KA-4 SlIGNALS LIGHTING TSi T5-LT TELEMETRY i1R%KA " r ryn -Form Letters with I M. weld Bow. Grind o'f Owniond Pattern before fontning lef tan. Electrical Consultants, Inc. 19015 36th Avenue West, Suite E Lynnwood, Washington 98036 Phone (425) 775-1799 FAX (425) 774-9870 1 I PLAN MEM W&VATM VIEW a" GINAVU PAO COMP*CWD r"4CAL AMCT10M )loot I114TALI.A7KW OETAMS a TYifMflax t,.,p PE 0 TY'g' am 1100 iEZelt ftAk 1111A s n ripe. r uo JUNCTION BOX DETAILS ADOPTED tl7Y a► iIBIITt3t1 Standard plans LST DATE.-11/89 DWG. NAME: JR-36 SP PAGE: J016 KING COUNTY, WASHING TON CONDUIT ENTR. AREA o°o PLAN W W sizE Too nT SZE TO FIT CABINET CABINET a + i I -code Level 4 FRONT VIEW SIDE VIEW STREET LIGHT CONTAQIQR FOUNDATION Shia to piu— Shim to Piumo +T See Note 3 -_ _-SNote 3 i 1 04 heepe _-qyae hoops is f'-/4 Uar eocn caner bar aoe, nor `o ; 5" MIN --- - - t" to 2" J �- 6- Mm - --- t to 2" J 3/e" ai_tr pi mx &sii, \`3/e' 3ameier W-tic a.;, SIDE 1GEYl SIB VIEIV I'-e" CapFet6.pth, 1'-e" V-Ir Cabk t Opth I u m ear aoeh m /4 her a-J, corner � come `e + /4 hoops N l+•wa e + 8 - — 6. ILI PLAN VIEW RJ PI AN VIEW PAD MOUNT PAD MOUNT CQhlTROLLER CABINET FOUNDATION BATTERY BACKUP SYSTEM (BBB) FOUNDATION For NOTES see Std. Plan 126.2 + J PUBLIC WORKS CABINET FOUNDATION DETAILS RD�, PLAN - 126.1 DEPARTMENT N a -- LE.:.,.,TEK ITE-ON GROUP GreenCobraTm LED Street light GC1 F-Series Specification Data Sheet Luminaimte Deft Weight 21 Ibs i9.5 kgl EPA 0.9 it" TyPfi0le{i pe catalog qo. 25 =9 m GC160E-MV-NW-2-GY-700 I ovooCosoo ®oo®®ooamo Ordering Information • e Sample Catalog No. 6C1 60F My NW 2 GY 350 BSK RPB FDC Product No. St Type Voltage' Color Distribution finish Drive 3 Options of LEDs Temperature Current � GCl 20F 4 MV 1 ZC T"J WW 3000i, 42 Type 2 ]GY Gray 350 350MA HSS' House Side Shield 3OF HV 3 Type 3 DO Dark SW 530mA (Factory Installed) 40F C1N -.x„ - Bronze* 700 7OOmA FDC" Fixed Drive Current 60 SK Black 1A" 1A FFA' Full Field Adlustability SOFLPCR Less Photocontrol Receptacle I PCR7 ANSI 7 wire Photocontrol I I Receptacle j I PCR7-CR' Control Ready 7-wire Photocontrol Receptacle i sc PCR Shorting Cap I WL Utility Wattage Label , Notes: 1 MV is DLC qualified. HV is DLC qualified on request, consult factory. 2 Gray. Black and Dark Bronze standard, consult factory for other finishes. HSSII -louse Side Shield 3 Specified drive current code is the factory set maximum drive current. Field ad)ustable current selector enables SPWD Square Pole Horaorital Arm Bracket standard dimming to tower wattage drive currents only. Consult factory if wattage limits require a special drhre i �PS10 Round Pole Horizontal Arm Bracket current PTd10 Pole Top Tenon Horizontal 4 SA drive current only available with 40F. ! Arm Bracket S Flush mounted house side shield factory installed. Shieid cuts light off at 112 mounting height behind [uminaire- nd210 Pole Top Tenon Horizontal 6 Non -field adjustable, fixed drive current. Arm Bracket (2@180') WSW 7 The FFA option enables full field adjustability from the specified drive current code to all drive currents available. Wall Horizontal Arm Bracket WK Bird Deterrent Spider Kit This option is not DLC qualified. i III Twist Lock Photocontrol 8 Control -ready wired at factory for wireless node dimming. Suppiled at maximum drive current. If lower drive L�L<tC" Long -Life Twist Lock Photocontrol current is required, consult factory, . Twist Lock Shorting Cap 9 Flush mounted house side shield. Shield cuts light off at 172 mounting height behind lumirwire. Specify Modal__ - and Color. A—Tiorles are ordered separately and not to he :ntluded in 10 Specify Color (Gy, DO, BK) the analog numfief 11 specify My 1120.27711) or HV (347V-4WV) 02017 Leotek Electronics USA, GCl_F-Serles_Spec Sheet_090717. Specifications subject to change without notice. R COei S U.S.A.; Liill��... UNDERGROUND UTILITY NOTE YOU MUST CALL 1-800-424-555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCAVATION WHERE ANY UNDERGROUND UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN BEARING SUBSTANTIAL REPAIR COST. co N 0 ^ 1 ` W N 0 0 0 T J 1 0 0 0 0 1 T I t'\ I IN COMPLIANCE WITH CITY OF RENTON STANDARDS � CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION 1 REVISED PER HEARING EXAMINERS CONDITIONS OF APPROVAL MEV 7-14-17 SUINEYFD Lac SCALE: AS NOTED -- ONE INCH "p" ' °w1e° �1D°' DATUM CITY OF R V R E N TO N VASOF Planning/Building/Public Works Dept. REN TON SPECIAL CARE COMMUMI TY, LL C REN TON SPECIAL CARE COMMUM/ TY 17033 108 TH AVE SE, REN TON, WA 98055 STREET LIGHTING DETAILS 2 REVISED PER CITY COMMENTS 9-21-17 �M 1 RAD GRWN 4 REVISED PER CITY COMMENTS MEV 11-13-17 5 6 - 6 REVISED PER CITY COMMENTS -- - _ REVISED PER CITY COMMENTS 12-15-17 2-07-17 eye► I AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY N0. REVISION BY DATE i APPR V J V 02-05-18 FIRDWX PAGE: O ES-03 z SHEET: OF: W 3 3 T-396203