HomeMy WebLinkAboutP_Site_Plans_CUP_180118_v1MAP CREATED BY:
Date: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Landuse_CUP\Renton\Version_N\PSE_Renton_Index.mxdTopo Basemap - ESRI Online,Transmission Line - PSE
ST169
ST900
§¨¦405 Renton
Renton
Newcastle
KingCounty 6
7
8
9
10
11
12
13
14
15
16
17 18
19 20
21
22
23
24 25
26 27
28 29 30
1
2
3 4
5
I0 0.25 0.5Mile
RENTON
CONDITIONAL USE PERMIT INDEX /CRITICAL AREAS LAND USE PERMIT
SOURCES:
APPLICANT:Brad StrauchPuget Sound EnergyP.O. Box 97034, Bellevue WA 98009-9734 (425) 456 - 2556
ACREAGE IN RENTON: 54.5 acres
§¨¦405 Renton
Newcastle 8888!(D!(D&-&-4/2C-16AA1
4/2C-16BA1 K
i
n
g
C
o
u
n
t
ySE 95TH
WAY
0423059142 33451004453345100450
3345100470
3345100475
7788000140
K i n g C o u n t yC
i
t
y
o
f
N
e
w
c
a
s
t
l
eC i t y o f R e n t o n
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I220+00831
4/2SCT10EAST 100FT/WEST 100FTSTA=221+56.71HT=88FT EL E=325.36
400
420440
460480
340
360
380
320
300
280
SITE PLAN
500
520540560
400
420440
460480
340
360
380
320
300
280
500
520
540560
Profile V iewStruc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 1 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 2
§¨¦405 Renton
Newcastle88!(D!(D&-&-4/1C-18AC1
4/1C-18BC1 #*#*0423059069
0423059142
3345100450K i n g C o u n t yC i t y o f R e n t o n
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I215+00210+00501
831
4/1
SCDE60EAST 072FT /W EST 072FTST A=213+1.0HT =72FT ELE=449.25
400
420
440460
480
340
360
380
320
500
520
540560
580
600
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 2 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 1MATCHLINE SHEET: 3
§¨¦405 Renton
Newcastle 888888!(D!(D!(D!(D!(D&-&-&-&-&-3/9C-17AC1
3/9C-17BC1
3/10C-2AC1
3/10C-2BC1 4/1C-18AC1#*S
E
1
0
0
T
H
S
T
N
E
2
4
T
H
S
T
0423059002
0423059069
0423059142
0423059282
0423059313
04280000100428000015
0428000020
0428000290 K i n g C o u n t yCity of RentonSITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I210+00501
205+00418
3/10SCA15EAST 095FT /W EST 095FTST A=208+1.11HT =95FT ELE=450.50
400
420440
460
480
380
500
520
540560
580
600620
640
660680
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 3 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 2MATCHLINE SHEET: 43/9SCHDE5EAST 050FT /W EST 050FTST A=203+76.41HT =50FT ELE=440.87
§¨¦405 Renton
Newcastle 888!(D!(D!(D!(D&-&-&-&-&-3/7C-1A1
3/8C-17AC1
3/8C-17BC1
3/9C-17AC1
3/9C-17BC1
S
E
1
0
0
T
H
S
T
126TH AVE SE0423059002
04280000200428000025
0428000095
04280000950428000100
0428000105
0428000155
0428000160
0428000165
04280001900428000195
04280002000428000205
0428000210
0428000290 0428000290
0428100530
3449820290 3449820300
3449820310
3449820320
K i n g C o u n t yC i t y o f R e n t o n
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I200+00361239
3/9SCHDE5EAST 050FT /W EST 050FTST A=203+76.41HT =50FT ELE=440.87
3/8SCHD E5ST A=200+3.60EAST 050FT /W EST 050FTELE = 438.00
3/7DCT 2D90FTST A=197+97.16HT =77FT ELE=444.87
400
420440
460480
380
500
520
540560
580
600
620
640
660
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 4 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 3MATCHLINE SHEET: 5
§¨¦405 Renton
Newcastle8!(D!(D&-3/6C-1A1
NE21STS
T NEW P ORT CTNE
OLYMPIAAVENE0423059035 0428100530
0428100540
0428100545
3449820140
3449820150
3449820160
3449820170
3449820190
3449820200
3449820210
3449820220
34498202303449820240
3449820250
3449820260 3449820270 3449820280
3449820460
3449820470
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 195+00190+00615
3/6DCT 2D95FTST A=191+72.13HT =80FT ELE=401.63
852
400
420440
460480
380
500
520
540560
580600
400
420440
460480
340
360380
320300
500
520
540560
580600
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 5 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 4MATCHLINE SHEET: 6340
360
320300
§¨¦405 Renton
Newcastle
8
8
!(D!(D&-&-3/5C-18AC1
3/5C-18BC1#*#*MR01(Honey Creek)Type F
0423059035
0423059342
3888320090
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I185+00852
3/5SCDE60EAST 090FT /W EST 090FTST A=183+20.03HT =90FT ELE=403.89
400
420440
460480
340
360380
320300
280
260
500520
240
400
420440460
480
340
360380
320
300
280
260
500
520
240
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 6 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 5MATCHLINE SHEET: 7
§¨¦405 Renton
Newcastle
8 8
!(D!(D&-3/4C-1A1
NE15 TH ST0423059023
0423059097
0423059269
0423059342
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I180+00175+00672
3/4SCDE60105FTST A=176+67.86HT =91FT ELE=397.38
400
420440
460
480
340
360380
320300
500
520
540560
580600
400
420
440
460
480
340
360380
320300
500
520
540560
580600
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 7 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 6MATCHLINE SHEET: 88
§¨¦405 Renton
Newcastle8888!(D!(D!(D!(D&-&-3/2C-1C1
3/3C-1C1
SR 9
0
0
0423059080
04230590970423059127
0423059145
0423059153
0423059269
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I170+00536401
3/3DCA15100FTST A=171+22.20HT =100FT ELE=389.41
3/2DCA15090FTST A=167+21.64HT =90FT ELE=391.71
400
420440
460
480
340
360
380
320300
500
520
540560
580600
400
420
440
460480
340
360380
320300
500
520
540560
580600
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 8 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 7MATCHLINE SHEET: 9
§¨¦405 Renton
Newcastle8!(D!(D&-3/1C-1A1
NE 12TH STLYNNWOOD AVE NE
MONROE AVE NE
0423059096
0423059127
0423059169
0423059182
0423059316
0423059317
77361000057736100009773610001077361000157736100016
7801300000
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 165+00160+00564458
3/1DCT 2125FTST A=161+67.96HT =109FT ELE=383.42
400
420
440
460480
340
360380
320
SITE PLAN
500
520
540
560580
600
400
420440
460480
340
360380
320
500
520
540560
580
600
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 9 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 8MATCHLINE SHEET: 10
§¨¦405 Renton
Newcastle
8
8
!(D!(D!(D!(D&-&-2/9C-1A1
2/10C-1A1#*MONROE AVE NE
LYNNWOOD AVE NE
28548000302854800035285480004028548000452854800050
2854800055
28548000602854800065
285480007028548000752854800080
7227900028
7227900030
7801300000
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I155+00525
2/10DCT2100FTSTA=156+96.08HT=86FT EL E=390.15
2/9DCT2100FTSTA=151+75.53HT=86FT EL E=397.22
400
420440
460480
340
360380
320
500
520
540560
580
600620
400
420440
460
480
340360
380
320
500
520540
560580
600620
Profile V iew Struc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 10 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 9MATCHLINE SHEET: 11
§¨¦405 Renton
Newcastle
8
!(D!(D&-2/8C-1A1NE10THST
MONROE AVE NE
2854800080
2854800085285480009028548000952854800100
2854800105 2854800110 2854800115 2854800120 2854800125 7227900028
7809000005780900001078090000157809000020
7809200005
780920001078092000157809200020
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxd&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 150+00145+00533542
2/8DCT 2110FTST A=146+42.17HT =95FT ELE=393.88
400
420440
460
480
340
360380
SITE PLAN
500
520540
560580
600620
400
420440
460
480
340
360
380
500
520
540560
580
600620
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 11 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 10MATCHLINE SHEET: 12Projec t Corr dior
§¨¦405 Renton
Newcastle!(D!(D&-2/7C-1A1
NE 8TH STNE 7TH CTMONROE AVE NE
7809000025780900003078090000357809000040780900004578090000507809000055
780920002078092000257809200030780920003578092000407809200045780920005078092000557809200060780920006578092000707809200075
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I140+00615 542
2/7DCT 2110FTST A=140+98.42HT =95FT ELE=394.84
400
420440
460480
340
360
380
500
520
540560
580
600620
400
420
440
460
480
340360
380
500520
540
560
580
600620
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 12 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 11MATCHLINE SHEET: 13
§¨¦405 Renton
Newcastle
8
8
888!(D!(D!(D!(D&-&-2/5C-1A1
2/6C-1A1NE 7TH STNE 7TH PLMONROE AVE NE
7227800425
7227800426
7809200080
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I 135+00130+00601
2/6DCT2115FTSTA=134+85.06HT=100FT EL E=386.81
2/5DCT2100FTSTA=128+84.48HT=86FT EL E=378.68
400
420
440
460
480
340360
380
320
500520
540
560
580
400
420
440
460
480
340
360380
320
300
500
520
540
560
580
Profile V iewStruc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 13 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 12MATCHLINE SHEET: 14300
§¨¦405 Renton
Newcastle8!(D!(D&-2/4C-1C1
NE 6TH PLNE 6TH STRENTON TECH ACRD
MONROE AVE NE
7227800425
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I125+00120+00598594
2/4DCA15085FTST A=122+86.01HT =85FT ELE=378.32
400
420
440
460
480
340
360380
320
300280
500
520
540
560
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 14 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 13MATCHLINE SHEET: 15
§¨¦405 Renton
Newcastle88!(D!(D&-2/3C-1A1
M O NRO E AVE NE
RENTON TEC H A C R D72278004257227800500
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 120+00594
115+00652
2/3DCT 2110FTST A=116+81.81HT =95FT ELE=341.54
400
420
440
460
480
340
360380
320
300
280
500
520
540
560
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 15 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 14MATCHLINE SHEET: 16
§¨¦405 Renton
Newcastle88!(D!(D!(D!(D&-&-&-2/1C-18AC1
2/1C-18BC1
2/2C-1C1#*NE 4TH
STRENTON TECH
ACRD
1623059058
1623059059
1623059111
1623059112
7227800500
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I110+00281
2/2DCA15D115FTST A=110+39.98HT =115FT ELE=340.44
2/1SCDE30EAST 100FT /W EST 100FTST A=107+58.76HT =100FT ELE=339.96
105+00400
420
440
460
480
340
360380
320300
280
500
520
540
260
400420440
460
480
340
360
380
320300
280
260
500520
540
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 16 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 15MATCHLINE SHEET: 17
§¨¦405 Renton
Newcastle!(D!(D&-1/7C-1A1
1434000010
1434000012
1434000020
1623059059
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I 105+00100+00755
1/7DCT2D105FTSTA=100+3.83HT=91FT EL E=331.93
400
420
440
460
480
340
360380
320
300
280260
500520
540
Profile V iew Struc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 17 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 16MATCHLINE SHEET: 18
§¨¦405 Renton
Newcastle!(D!(D&-1/6C-1A1
1434000010
1434000020
1623059133
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I95+0090+00673585
1/6DCT2105FTSTA=93+31.08HT=91FT EL E=337.03
400
420
440
460
480
340
360380
320
300
280260
500520
540
400
420
440
460
480
340
360
380
320
300
280260
500520540
300
280260
Profile V iew Struc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 18 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 17MATCHLINE SHEET: 19
§¨¦405 Renton
Newcastle!(D!(D!(D!(D&-&-1/4C-1A1
1/5C-1A1SE 1ST STINDEX AVE SE1434000010
1434000020
1623059133
4307300550 4307300560 4307300570 4307300580 4307300590 4307300600 4307300610
4307301240
4307310360
4307310370
4307310380
43073103904307310400
4307330340 4307350010
4307350020
4307351230
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I85+00583 585
1/5DCT 2115FTST A=87+86.09HT =100FT ELE=299.67
1/4DCT 2; 130FTST A=81+73.15HT =113FT ELE=259.19
400
420
440
460
340
360
380
320300
280260
180
200
220240
300
280260
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 19 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 18MATCHLINE SHEET: 20
§¨¦405 Renton
Newcastle!(D!(D!(D!(D&-&-1/3C-1A1
1/4C-1A1
#*FERNDALEAVESE4307300390
4307300410
4307300420
4307300430
4307300460
4307300470 4307300480 4307300490 4307300500 4307300510 4307300520 4307300530 4307300540
4307301230
4307301240
430732022043073202304307320240430732025043073202604307320270 4307330270 4307330280 4307330290 4307330300 4307330310 4307330320 4307330330 4307330340
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I
1/4DCT 2; 130FTST A=81+73.15HT =113FT ELE=259.19
80+00515548
1/3DCT 2D085FTST A=76+58.13HT =73FT ELE=306.00
75+00400
420
440
460
340
360380
320
300
280
260
180
200
220
240
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 20 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 19MATCHLINE SHEET: 21
§¨¦405 Renton
Newcastle !(D!(D!(D!(D!(D&-&-&-1/2C-18BC1
1/3C-1A1
1/2C-18AC1
#*#*FERNDALEAVESESE 3RD ST
3955901130
4307300380
4307300390
4307300400
4307300410
4307300420
4307301220
4307301230
4307301260
4307320250430732026043073202704307320280430732029043073203004307320310
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I
548
75+0070+00410
1/2SCDE60EAST 070FT /W EST 070FTST A=71+9.79HT =70FT ELE=334.50 400
420
440
460
480
340
360380
320300280
260
500520
240
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 21 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 20MATCHLINE SHEET: 22
§¨¦405 Renton
Newcastle!(D!(D&-1/1C-1A1
Not Rated
SR 169
1623059035
1623059131
4307301220430730TRCT
430732032043073203304307320340430732TR-W
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I
410
65+001,524
1/1DCT 2D090FTST A=66+89.56HT =77FT ELE=333.62
400
340
360
380
320
300
280260
120
140
160
180
200
220
240
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 22 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 21MATCHLINE SHEET: 23
§¨¦405 Renton
Newcastle
Cedar River [ND]Type S, Shoreline
NR02Type Ns
NR02Category II
NR03Category III SR 169CEDAR RIVER TRLRIV
E
R
VIE
W
P
A
R
K
WALK1623059012
1623059033
1623059078
162305HYDR
SITE PLAN
Date : 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProje c t Corrid or
&-Propos e d Pole Loc ation
!(D Exis ting Pole Loc ation–To Be Re m ove dTrans m is s ion Line - Propos e d
Trans m is s ion Line - Exis ting
#*Pote ntial Stringing Site
Re c om m e nd e d Ac c e s s - Propos e d Pole
Und e rground Powe r Utility LineUnd e rground W ate r & W as te wate r Utility Line
Parc e l
City Juris d ic tion Bound ary
Stre am
W e tland
W e tland or Stre am Buffe r
Land s lid e Hazard
Land s lid e Hazard 50ft Buffe r
Ste e p Slope
Ste e p Slope 50ft Buffe r
Eros ion Hazard I60+0055+001,524 320
300
280260
100
120
140160
180
200
220
240
4060
80
Profile Vie wStruc ture
Cond uc torGround Line
Major Ele vation GridMajor Station Grid
Minor Station Grid Page 23 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Fe e t1 inc h = 50 fe e t
MAP EX TEN T
RENTON
SOURCES: Road s and Parc e ls - King County (2015), Ae rial- King County (2015); Stre am s , W e tland s and Buffe rs ,Land s lid e Hazard and Buffe rs , and Ste e p Slope s andBuffe rs from W ate rs he d Com pany (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Propos e d Pole N um be rStruc ture Type (Se e Appx. A)Cons truc tion Sc e nario Ke y(Se e Appx. B)MATCHLINE SHEET: 22MATCHLINE SHEET: 24
§¨¦405 Renton
Newcastle!(D!(D&-0/9C-1A1
SE8THSTHARRINGTON PL SE
KIRKLAND AVE SE
1623059012
1623059078
1623059078
7701590000
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I50+00595
0/9DCT2D100FTSTA=51+65.84HT=86FT EL E=249.01
400420
340
360
380
320
300
280260
120140160
180
200
220
240
Profile V iewStruc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 24 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 23MATCHLINE SHEET: 25
§¨¦405 Renton
Newcastle
!(D !(D
!(D
!(D!(D
&-
&-
&-&-
&-
0/8C-18BC1
0/8C-18AC1
115-5
115-4115-3
#*
#*
NR02Type Ns
NR04Category III
H
A
R
RIN
G
T
O
N
PL
S
E
SE 8T
H
S
T
SE 8THPL
2123059003
7701570000
7701590000
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdProjec t Corrid or
&-Prop osed Pole L oc a tion
!(D Existing Pole L oc a tion–To Be Rem ovedTra nsm ission L ine - Prop osed
Tra nsm ission L ine - Existing
#*Potentia l Stringing Site
Rec om m end ed Ac c ess- Prop osed Pole
U nd erground Power U tility L ineU nd erground Wa ter & Wa stewa ter U tility L ine
Pa rc el
City Jurisd ic tion Bound a ry
Strea m
Wetla nd
Wetla nd or Strea m Buffer
L a nd slid e Ha za rd
L a nd slid e Ha za rd 50ft Buffer
Steep Slop e
Steep Slop e 50ft Buffer
Erosion Ha za rd I45+00697
0/8SCDE90EAST 100FT/WEST 100FTSTA=45+62.15HT=100FT EL E=275.79
400
420
440
460
480
340
360380
320300
280
260
500
200220
240
Profile V iewStruc ture
Cond uc torGround L ine
Ma jor Eleva tion GridMa jor Sta tion Grid
Minor Sta tion Grid Page 25 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION N
I 0 25 50 Feet1 inc h = 50 feet
MAP EXTENT
RENTON
SOU RCES: Roa d s a nd Pa rc els - King County (2015), Aeria l- King County (2015); Strea m s, Wetla nd s a nd Buffers,L a nd slid e Ha za rd a nd Buffers, a nd Steep Slop es a ndBuffers from Wa tershed Com p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Prop osed Pole Num b erStruc ture Typ e (See Ap p x. A)Construc tion Sc ena rio Key(See Ap p x. B)MATCHLINE SHEET: 24MATCHLINE SHEET: 26
§¨¦405 Renton
Newcastle
!(D
!(D!(D !(D
&-
0/7C-1A1
NR01(Ginger Creek)Type Np
NR01Category III
NR02Category IIINR02Category
I
I
I
D
NR02
-
E
s
t
i
m
a
t
e
d
Category
I
I
I
NR02Category III
2023059001
2023059050
2123059003
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 40+0035+00702
0/7DCT 2D110FTST A=38+95.26HT =95FT ELE=360.45
400
420
440
460
480
340
360
380
320300
280
500520
540
560
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 26 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION N
I 0 25 50 Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 25MATCHLINE SHEET: 27
§¨¦405 Renton
Newcastle
!(D !(D
!(D!(D!(D
&-&-
0/5C-1A1
0/6C-1A1
NR02Category IIID
C
EDAR
RIDGEDRSE
2023059001 2023059001
2023059050 2023059050
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I30+00700
0/6DCT 2125FTST A=31+83.14HT =109FT ELE=400.66
400
420
440
460
480
340360
380
500
520
540
560
580600
620
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 27 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION N
I 0 25 50 Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 26MATCHLINE SHEET: 28
§¨¦405 Renton
Newcastle
!(D !(D !(D
!(D!(D !(D!(D
&-
&-
&-
&-
&-0/3C-19C10/5C-1A1
0/4C-18AC1
0/4C-18BC1
115-2
#*BEACON WAY
S
2023059001
2023059002
2023059003
2023059066
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 25+0020+00546
0/5DCT 2D125FTST A=24+98.52HT =109FT ELE=414.55
0/4SCDE110EAST 070FT /W EST 070FTST A=19+47.02HT =70FT ELE=430.97299
0/3DCDE2075FTST A=17+38.25HT =75FT ELE=43
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 28 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION N
I 0 25 50 Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 27MATCHLINE SHEET: 29400
420
440
460
480
340360
380
500
520
540
560
580600
620
§¨¦405 Renton
Newcastle !(D!(D!(D!(D!(D!(D!(D!(D&-&-&-&-&-0CC0/1C-18BC10/2C-19C1
0/3C-19C1
0/4C-18AC10/4C-18BC1
0/1C-18AC1
0/4C-18A115-2#*BEACON WAY S
2023059002
2023059003
2023059051
2023059062 2023059066
2023059066
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I 20+000/4SCDE110EAST 070FT /W EST 070FTST A=19+47.02HT =70FT ELE=430.97
15+00306 299
0/3DCDE2075FTST A=17+38.25HT =75FT ELE=430.35
0/2DCDE90090FTST A=12+38.27HT =90FT ELE=431.39
400
420440460
480
340
360380
500
520
540
560
580
600
620
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 29 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION NI02550Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 28MATCHLINE SHEET: 30
§¨¦405 Renton
Newcastle
!(D!(D!(D
&-
&-
&-0/1C-18AC1
0/1C-18BC1
0/2C-19C1
BEACONWAYS2023059003
2023059051
2023059062
2023059066
SITE PLAN
Da te: 1/18/2018Path: G:\Projects\Washington\Puget_Sound_Energy_007022\EnergizeEastsideMapbook_10059878\7.2_WP\Map_Docs\Renton\Landuse_CUP\Version_N\PSE_Renton_CUP.mxdPro jec t Co rrido r
&-Pro p o sed Po le Lo c a tio n
!(D Existing Po le Lo c a tio n–To Be Rem o vedT ra nsm issio n Line - Pro p o sed
T ra nsm issio n Line - Existing
#*Po tentia l Stringing Site
Rec o m m ended Ac c ess- Pro p o sed Po le
U ndergro und Po wer U tility LineU ndergro und W a ter & W a stewa ter U tility Line
Pa rc el
City Jurisdic tio n Bo unda ry
Strea m
W etla nd
W etla nd o r Strea m Buffer
La ndslide Ha za rd
La ndslide Ha za rd 50ft Buffer
Steep Slo p e
Steep Slo p e 50ft Buffer
Ero sio n Ha za rd I
332
0/2DCDE90090FTST A=12+38.27HT =90FT ELE=431.39
10+00199
0/1SCDE110/SCDE90075FTST A10+35.18HT =75FT ELE=443.43
400
420440
460
480
360380
500
520
540
560
580
600
620
640660
Pro file View Struc ture
Co nduc to rGro und Line
Ma jo r Eleva tio n GridMa jo r Sta tio n Grid
Mino r Sta tio n Grid Page 30 of 30
BASED ON PSE ENGINEERINGDESIGN REVISION N
I 0 25 50 Feet1 inc h = 50 feet
MAP EX T ENT
RENTON
SOU RCES: Ro a ds a nd Pa rc els - K ing Co unty (2015), Aeria l- K ing Co unty (2015); Strea m s, W etla nds a nd Buffers,La ndslide Ha za rd a nd Buffers, a nd Steep Slo p es a ndBuffers fro m W a tershed Co m p a ny (2017).
For cartographic purposes only.
Note:Note: Underground utility lines are surveyed in thevicinity of poles only. Existing Lake Tradition poles aren'trepresented by new conductors because they are anexisting line, and are being represented due to the polesbeing replaced.
5/7C-16A1
Pro p o sed Po le Num b erStruc ture T yp e (See Ap p x. A)Co nstruc tio n Sc ena rio K ey(See Ap p x. B)MATCHLINE SHEET: 29MATCHLINE SHEET: 31
STRUCTURE TYPES
Appendix A
Date: 1/18/2018
BASED ON PSE ENGINEERING DESIGN REVISION N
RENTON
Structure Type Naming Convention Description
SCDE C-18 A/B Single circuit deadend
SCT C-16 A/B Single circuit tangent
DCT C-1 / C-19 Double circuit tangent (D denotes OHGW overhead groundwire)
DCA C-1B Double circuit angle - equiv to a C1 with a post brace to handle bigger angle
SCHDE C-17 A/B Single circuit horizontal deadend (only under SCL line)
SCA C-2 A/B Single circuit angle
*number after type in table denotes angle
Eastside 230 ROW and structure options.dgn 8/16/2017 2:06:44 PM
Structure Height
65'-105'
85'-90'
70'-120'
85'-115'
50'
90'-95'
CONSTRUCTION SCENARIOS
Appendix B
Date: 1/18/2018
BASED ON PSE ENGINEERING DESIGN REVISION N
RENTONStructure Type
Typical Construction
Scenario
(Not in critical area)
Typical Construction
Scenario
(In a critical area)
C-1 A1 A2
C-2 C1 C2
C-1B C1 C2
C-16 A1 A2
C-17 C1 C2
C-18 C1 C2