HomeMy WebLinkAboutR-426823SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
00
c0
N
41
O
0
W
H
LU
Z
a
a
ti
V♦
LU
i
Q
I`0
Lr�
I
C"'l
CD
N
CD
U
0
N
I
U
U
I
C7
W
Q
U
C=
O
U
>_
C3
C3
I
CD
W
N
i
U
O
N
15
O
O
J
/
C=
U
I
C7
U
0
Q
U
CD
/
00
0
CV
i
a�
Q�
rn
FINI
PAS
Ion
J LO D
O O ^ LW
�
Qww
a�wwn�
�oLLw
w
U Z U
D-m
� U
TYPICAL DECIDUOUS TREE PLANTING
/`\ l NOT TO SCALE
2" BARK MULCH
211 WATER BASIN
PLANTING MIX
GROUNDCOVER PLANTING
NOT TO SCALE
GRNDCVR1
CITY OF RENTON I PERMIT CENTER
(D
TREE RETENTION AND CREDIT WORKSHEET
TREE RETENTION REQUIREMENTS
A minimum retention of thirty percent (30%) of all significant trees (as defined in RMC4-11-200) is required on site
Please complete the form below to verify compliance with minimum tree retention requirements.
Identify total number of trees 6-inch caliper or greater (or alder or
cottonwood trees 8-inch caliper or greater) on site:
Trees
• Deductions —Certain trees are excluded from the retention calculation:
0 Trees that are high -risk, as defined in RMC 4-11-200:
Trees
0 Trees within existing and proposed public right-of-way:
Trees
0 Trees within wetlands, streams, very high landslide hazards,
protected slopes, and associated buffers:
Trees
• Total remaining trees after deductions:
0
Trees
• Required tree retention (30%):
0
Trees Required
• Identify number of trees proposed for retention:
Trees Proposed
• Identify number of trees requested for replacement in lieu of retention
(skip page 3 if no tree replacement is requested):
0
Trees
TREE CREDIT REQUIREMENTS
Tree credit requirements apply at a minimum rate of thirty (30) credits per net acre. Complete the form below to
determine minimum tree credit requirements.
• Gross area of property in square feet: 72895 Square Feet
• Deductions: Certain areas are excluded from tree credit calculation:
0 Existing and proposed public right-of-way: Square Feet
o Wetlands, streams, very high landslide hazards, protected slopes,
and associated buffers: Square Feet
• Total excluded area: 0 Square Feet
• Net land area (after deductions) in square feet: 72895 Square Feet
• Net land area (after deductions) in acres: 1.67 Acres
• Required tree credits: 50 Tree Credits Required
rentonwa.gov/permitcenter I planningcustomerservice@rentonwa.gov 1 425-430-7294 10/6/2022 Page 1 of 3
ROOT BARRIER ALONG STREET FRONT CURB
STREET PAVING
REMOVE BURLAP AND TWINE OFF
ROOTBALL
GENTLY COMPACTED PLANTING MIX
AS SPECIFIED
RECOMPACTED PLANTING MIX
UNDISTURBED NATIVE SOIL
CU CONSTRUCTED SOIL
NOTE:
ALL GROUNDCOVER/SHRUB
SPACING SHALL BE
EQUIDISTANT UNLESS
OTHERWISE SPECIFIED
DISTANCE ON CENTER AS
SPECIFIED
START FIRST ROW OF
PLANTING AT 1 /2 THE
PERPENDICULAR SPACING
BETWEEN ROWS
EDGE OF PLANTING AREA
TRIANGULAR PLANT SPACING
NOT TO SCALE
TREE RETENTION AND CREDIT WORKSHEET
PROPOSED TREE CREDITS
Please complete the table below to calculate the total tree credits proposed for your project. Identify the quantity of trees
for each tree category, after deducting trees within excluded areas, as shown in the previous section.
TREE SIZE
TREE CREDITS TREE QUANTITY
I TOTAL TREE CREDITS
RETAINED TREES
Preserved tree 6-9" caliper
4
0
Preserved tree 10 —12" caliper
5
0
Preserved tree 12 —15" caliper
6
0
Preserved tree 16 —18" caliper
7
0
Preserved tree 19 — 21" caliper
8
0
Preserved tree 22 — 24" caliper
9
0
Preserved tree 25 — 28" caliper
10
0
Preserved tree 29 — 32" caliper
11
0
Preserved tree 33 — 36" caliper
12
0
Preserved tree 37" caliper and greater
13
0
NEW TREES
New small species tree (30' or less at maturity)
0.25
20
15
New medium species tree (30' to 50' at maturity)
1
0
New large species tree (50' or more at maturity)
2
23
46
TREE CREDITS PROPOSED:
rento—gw/oermltotlNer I planningcustomerservice@rentonwa.gov 1 425-430-7294
51
10/6/2022 Page 2 of 3
TRI-SPACE
NOTE:
PLANT TREES 1" HIGHER THAN
DEPTH GROWN IN NURSERY
TREE PIT SHALL BE NOT LESS
THAN 2 TIMES ROOTBALL
DIAMETER
2" DIA. LODGEPOLE PINE
STAKES - TYP.
3/4" CHAINLOK FASTENER
- TYP.
REMOVE BURLAP, TWINE AND WIRE BASKETS
2" MULCH LAYER -HOLD BACK FROM TRUNK 6"
3" WATERING BASIN -
Q
m� II
o w
=1
FINISH GRADE
BREAK SIDES AND BOTTOMS
OF PLANTING PIT TO ALLOW
FOR ROOT PENETRATION
PLANTING MIX AS SPECIFIED
RECOMPACTED NATIVE SOIL
TYPICAL CONIFEROUS TREE PLANTING
NOT TO SCALE
TREE-CON1
5'-0"
N
EXTERIOR BUILDING WALL
3/4" DIA. DRAINROCK BED
CONTINUOUS ALUMINUM EDGING WITH STAKES
MULCH COVER
0 0 0 0 0 0
3 TO
I
COMPACT SUBGRADE
DRA NROCK STRIP
NOT TO SCALE
PAVR-STONE
dl� ��d
d� � r�
REMOVE BURLAP AND
d� d TWINE OFF TOP 1 /3 OF
ROOTBALL
3" WATER BASIN
I FINISH GRADE
2" MULCH LAYER
PLANTING MIX AS SPECIFIED
BREAK SIDES AND BOTTOMS
OF PLANTING PIT TO ALLOW
FOR ROOT PENETRATION
RECOMPACTED NATIVE SOIL
6" I, ROOTBALL I, 6"
TYPICAL SHRUB PLANTING DETAIL
NOT TO SCALE
SHRUB-1
JGM
LANDSCAPE ARCHITECTS
INCORPORATED P.S.
LANDSCAPE ARCHITECTURE
URBAN DESIGN
SITE PLANNING
PARKS AND
RECREATION PLANNING
12610 NE 104TH STREET
KIRKLAND, WA 98033
PH: 425.454.5723
CELL: 206.795.3196
E-: jgm@jgm-inc.com
www.jgm-inc.com
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
T��
CERTIFICATE NO. 442
R-426822
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
fCCURRENT PLANNING � � DEVELOPMENT ENGINEERING
lark Close 12/15/2023 yqi 12/20/2023 '
5 CIVIL CONSTRUCTION PERMIT COMMENTS JGM 12.07.231 CL SURVEYED: SCALE: WEST77 PARTNERS DATE:
Z.NALL VERTICAL: NAVD 1988
4 CIVIL CONSTRUCTION PERMIT COMMENTS JGM 10.20.23 CL HORIZONTAL: NAD 1983/1991 CITY OF 12.07.2023
O DESIGNED: C. LEWI S ® L I VAWAY HOTEL FIELDBOOK:
3 CIVIL CONSTRUCTION PERMIT APPLICATION NAVIX 06.02.23 JET PAGE:
2 SITE PLAN REVIEW RESUBMITTAL NAVIX 03.03.23 JET DRAWN: C.LEWIS RENTON PARK AVENUE NORTH
ONE INCH DATUM • DRAWING NO:
4 1 INITIAL SITE PLAN REVIEW SUBMITTAL NAVIX o2.10.23 JET CHECKED: C.LEWIS AT FULL SCALE RENTON WA 98057 L2,0
O� IF NOT ONE INCH Planning/Building/Public Works Dept.
NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY HOTEL PLANTING DETAILS SHEET. 34 OF. 41
r
O
00
N
O
O
9
N
u
to
O
O
9
M
N
Q
M
J
co
0
O
O
1
N
N
W
IL
V♦
LU
Z
LL
a
ti
V♦
W
i