HomeMy WebLinkAboutW-426803SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. 00 N ti NN I.L I-300 - n C"'l 0 r� C"'l 0 CV C6 0 U N a 0 �I n w / co CY 0 C"'I C0 co (D / c 0 O) Of / 0 CY co / ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RESTRAINT SERIES 1100 RESTRAINED (OR APPROVED EQUAL) AND CONCRETE BLOCKING PER COR STANDARD PLANS REFER TO SHEET C-6.1 FOR UTILITY CROSSINGS I i 26+00 -15' WATER LINE EASEMENT 15 25+00 14 35 c° 26 d. LI<I I 37 I 138 I 39 aA 40 'AS G S 41 I I I 42 SD 21+00 32 24+49 I o I 22 21 I 23 I I0 - 24 w ' VALVE TO BE CLOSED UNTIL o I 0 25+49 NEW WATER MAIN IS INSTALLED, _ _ -I 28+48 TESTED AND APPROVED cry N o 4 I aLf 27+00 :I 3 I I E al LL AL 10 12" DI W 20+0U4---, W W 308-ZONE I 33 44 I PROPOSED 15' WATER LINE EASEMENT 28+00 36 16 I 25 24+00 I °° I 8 9 12 I 7 W +12�� - � 10.5' 196-ZONE ----------- _ _ 22+00 6 -7 27 20 I---- 29 I 43 5.2 IF I ` I I I• �. o o 26+39 28 43 30 WATER LINE EASEMENT I I 1 31 1 27+30J i i ri --I r.00 10VdW00 10VdW00 13VdW00 lOVdW00 lOVdW00 lOVdW00 1C""A00 10VdIM"I I I I --- --------------I COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPtJ I I I 1Ctid V^IOJ 13 VdW00l lOVdWOC 10VdWO0 I 10VdW00l lOVdC W00l lOVdW. I I I I �I I - - - J I W I COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT C( i V) 0 0 0 0 0 0 1 I .o. d : da A. O ° ?J ° ° N 1'29"W 3 2.OG' ° -x - x� GEM< F FO F F F 7�77_ F^ F^ WATER PLAN NOTES 1. ALL WORK ON THE EXISTING WATER SYSTEM, INCLUDING CONNECTIONS TO EXISTING MAINS, ABANDONMENT OF EXISTING PIPES, WATER SERVICES, OR OTHER SYSTEM COMPONENTS SHALL BE PERFORMED BY CITY FORCES WITH THE DIRECT SUPPORT OF THE CONTRACTOR. 2. MAXIMUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURE'S RECOMMENDED PERMISSIBLE DEFLECTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXISTING PIPES FOR PROPER FITTING AND DEPTH. 4. THE CONTRACTOR WILL PROVIDE AND INSTALL THE METER THAT IS LARGER THAN 2-INCHES 0 LLJ 'IC'/Y a� �- .II, a�n1� I PROPOSED 126 KEY HOTEL FFE = 31.5 0 D w (n O IV 0 rn rl f� I; IA I I� co I> I I EXISTING I FIRE HYDRANT I cn 4 c� D co 0 0 NEI C I IC ° S S I ° +28 I I S . . . . . . ... . ti Fv Fv F^ -„ F71 C 5 CIVIL CONSTRUCTION PERMIT COMMENTS NAVIX 12.07.23 JET SURVEYED: Z.NALL SCALE: 4 CIVIL CONSTRUCTION PERMIT COMMENTS NAVIX 10.20.23 JET DESIGNED: 0 3 CIVIL CONSTRUCTION PERMIT APPLICATION NAVIX 06.02.23 JET J.GREEN/D.RIDDLE O ® 2 SITE PLAN REVIEW RESUBMITTAL NAVIX 03.03.23 JET DRAWN: J.GREEN D.RIDDLE Q 1 INITIAL SITE PLAN REVIEW SUBMITTAL NAVIX 02.10.23 JET CHECKED: ONE INCH J.TAFLIN J.GREEN AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: J. TAFLI N SCALE ACCORDINGLY LEGEND PROPERTY LINE _ -W-W-W-W-W EX. 12" WATER MAIN 0 10 20 40 3 W WATER LINE C-4.5 310.1 ,i FIRE HYDRANT NSCALE: 1 inch = 20 ft. C-4.3 2 FIRE DEPARTMENT CONNECTION C-4.5 Q POST INDICATOR VALVE STORM DRAIN LINE O 00 BEND/TEE WITH THRUST BLOCKING 330.1 330.2 5' MIN. N 330.7 C-4.3 C-4.4 N GATE VALVE O C-4.4 WATER LINE 350.3 c�i DDCVA DETECTOR DOUBLE CHECK VALVE ASSEMBLY 0.5' MIN. N C-4.4, C-4.5 I 1 RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY 360.2 VWgTER/STORM SEPARATION I�I PRESSURE REDUCING VALVE 340.E 370.4 1 C-4.5 N.T.S. Z3204C-4.4C-4.5 C-4.5DOMESTIC WATER METER WATER SCHEDULE OCONNECT TO EXISTING 1s 72 LF 12" DI WATER MAIN 40 1 - 1" DCVA BACKFLOW ASSEMBLY 340.8 1 12" WATER MAIN PER STD. PLAN 340.2 STA: 22+32.27, 30.13' RT CONNECT TO EXISTING 1 - 12" X 6" TEE (FLxFL) O 16 WATER MAIN WITH: Cfl 1 - 12" ADAPTOR (FLxMJ) 310.1 1s " co4.2 41 1 - 12 GATE VALVE (MJxFL) C-4.3 1 - 16 X 12 TEE (FL) 1 LF 1.5" PE IRR. O to 1 - 6 GATE VALVE (MJxFL) 340.2 2 - 16" BUTTERFLY VALVE (FLxMJ) 42 1.5"IRRIGATION POINT OF CONNECTION O 1 - 12 GATE VALVE FLxMJ 1 -FIRE HYDRANT ASSEMBLY (FLxMJ) O 21 LF 6" DI C-4.4 2 - 16" SLEEVES (MJ) O 43 3" PRESSURE RELIEF PIPE AND STAND PIPE OO THRUST BLOCKING 1 - 12" SLEEVE (MJ) STA: 20+04.49, 0.00' THRUST BLOCKING W/ APPROVED AIR GAP (SEE STD PLN 340.6), M REFER TO STD. PLN. 300.3 FOR TO BE INSTALLED BY CITY FORCES. (y O 53 LF 12" DI WATER MAIN TESTING/FINAL CONNECTION DETAILS AND ALL 44 1 - TEMPORARY 12" END CAP (MJ) Q 1 - 90. BEND (MJ) REQUIRED FITTINGS/APPURTENANCES. GATE 1 - TEMPORARY 2" BLOW -OFF ASSEMBLY 340.2 3 O VALVE TO BE NORMALLY OPEN. 1 - 12"-LONG BODY SLEEVE (MJ) THRUST BLOCKING STA: 23+24.41, 0.00' RT 12" DI SPOOLS LENGTH TO FIT STA: 20+57.18, 0.63' RT FINAL CONNECTION TO NEW HYDRANT TEE TO 300.4 20 24 LF 4" DI O BE MADE BY CITY FORCES UPON COMPLETION 62 LF 12" DI WATER MAIN OF ALL CLEANING, TESTING AND DISINFECTION 4" DOMESTIC WATER METER WITH 320.4 676-WA VAULT OR APPROVED EQUAL OF NEW WATER MAIN PER STD PLAN 300.4. O5 21 1 - CONCRETE VAULT (612-LA) WITH STA: 22+26.24, 28.04' RT 3 LOCKING STEEL COVERS (3-332P) O AND 24" CONCRETE RISER EXTENSION 22 4 LF 4" DI (612-2X), OR APPROVED EQUAL 4" REDUCED RBPA IN SAFE-T-COVER 360.2 2 - 12"x10" REDUCER (MJxMJ) L0 23 HOT BOX MODEL 300-AL OR to 2 - MIN. 3 LF 10" DI SPOOLS (FLxPE) C-4.5 FLANGED ENDS SHALL BE 6" AWAY APPROVED EQUAL M 1 STA: 22+26.19, 36.93' RT CDFROM INSIDE VAULT WALLS C)1 - DI COUPLING ADAPTER (MJxMJ) c-4.5 24 4 LF 4" DI O 2 - 10" DI WATER MAIN (PExPE) N 2 - ADAPTOR (FLxMJ) 340.E 370.4 25 5 LF 12" DI" DI WATER MAIN N STA: 21+29.83, 1.35' RT C-4.4 C-4.5 26 1 - 1" WATER SERVICE PER STD PLN 320.1 13 LF 1"TYPE K COPPER STUB W/ CAP 320.1 N"IX O 16 LF 12" DI WATER MAIN STA: 22+51.08, 0.00' RT a C-4.3 SITE I CIVIL O1 - 90° BEND (MJ) THRUST BLOCKING 27 22 LF 6" DI FIRE 11235 s.e. 6th street I suite 150 STA: 21 +57.64, 0.00' » 2s 6 DOUBLE DETECTOR CHECK bellevue, wa 98004 O 12 LF 12" DI" DI WATER MAIN ASSEMBLY WITH STANDPIPE OUTSIDE 350.3 t: 425.453.9501 1 f: 425-453-8208 56 LF 6" DI C-4.4, C-4.5 www.navixeng.com O1 - 12 X 6 CROSS (MJxFL) STA: 22+17.09, 30.15 RT g• 9 310.1 1 - 12" GATE VALVE (MJxMJ) FIRE DEPARTMENT CONNECTION 2 2 - 6" GATE VALVE (MJxFL) C-4.3 29 STA: 21+30.55, 22.80' RT C-4.5 7 LF 6 DI STUB WITH CAP (NORTH) LI ZABET 1 - FIRE HYDRANT ASSEMBLY pF WAShrj 27 LF 6" DI (SOUTH) 30 2 LF 6" DI FIRE ��� T THRUST BLOCKING 31 POST INDICATOR VALVE w STA: 21+70.33, 0.01 LT STA: 22+17.09, 38.63 RT 10 32 4 LF 6" DI FIRE ,A 41872 PROTECT EXISTING WATER MAIN TO REMAIN. �o��,s�'GIsrER����,w 33 SEE NOTE 44 FOR TEMPORARY CAPPING s10NAL E� 11 EXISTING WATER MAIN ON WEST SIDE. /2/07/ZQ23 EXISTING FIRE HYDRANT INSTALLED UNDER 34 TOPGOLF PROJECT TO BE REMOVED AND RELOCATED WITH NEW HYDRANT TEE AND VALVE 12 48 LF 12" DI WATER MAIN 35 6 LF 12" DI WATER MAIN 1 - 12" X 6" TEE (FLxFL) O 1 - 1" SADDLE TAP 1 - 12" GATE VALVE (MJxFL) 36 1" WATER SERVICE PER STD. PLN.320.1 320.1 13 1 - 12" ADAPTOR (FLxMJ) 1 - 1" GATE VALVE (THREADED) 1 - 6" GATE VALVE (MJxFL) STA: 22+32.16, 0.00' RT THRUST BLOCKING 37 STA: 22+17.09, 0.01 LT 22 LF 1" TYPE K SOFT COPPER TUBING 14 10 LF 12" DI WATER MAIN 38 1 - 1" IRRIGATION METER 320.1 O STA: 22+32.23, 25.46' RT C-4.3 1 - 12" x 4" TEE (MJxFL) 15 1 - 4" GATE VALVE (FLxMJ) 320.4 39 1 LF 1" TYPE K SOFT COPPER TUBING IRR W-426803 STA: 22+26.32, 0.01' LT IN COMPLIANCE WITH CITY OF RENTON STANDARDS 16 13 LF 12" DI" DI WATER MAIN 1 - 12" GATE VALVE (MJxFL) WATER UTILITY DEVELOPMENT ENGINEERING 17 1 - 2 TAPPED REDUCING TEE (MJxFIPT) jchavez 12/20/2023 ' i 12/20/2023 1 - 2" GATE VALVE (THREADED) ya W 7 LF 2" TYPE K COPPER STUB W/ CAP Z THRUST BLOCKING 320.3 z STA: 22+46.33, 0.00' RT C-4.3 Q VERTICAL: NAVD 1988 DATE: HORIZONTAL: NAD 1983/1991 WEST77 PARTNERS 12.07.2023 C I TY OF L I VAWAY HOTEL FIELDBOOK: [;%Rl R E N TO N PAGEI • PARK AVENUE NORTH DRAWING N0. DATUM � Planning/Building/Public Works Dept. RENTON , WA 98057 C-4.0 W WATER PLAN SHEET: 22 OF. 41