Loading...
HomeMy WebLinkAboutT-42680200 N Ti 47 O w F- LU Z Q a. ti W Q CT O I r� N O N O O U N Q0 n LJ / co CT 0 N N r, r, (D / C O / O co / m a< I � J 3 D I �I y n I O I D I 0 I D I y o F - ---I 9- RDLa�-RDL afir COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT I COMPAI I COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT I C( SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. I I I r I I D I I I Cn F F F n FO F0 FO_ -F� IDI�FO � F rn 5 CIVIL CONSTRUCTION PERMIT COMMENTS 4 CIVIL CONSTRUCTION PERMIT COMMENTS 0 3 CIVIL CONSTRUCTION PERMIT APPLICATION O 2 SITE PLAN REVIEW RESUBMITTAL �Q 1 INITIAL SITE PLAN REVIEW SUBMITTAL NO. REVISION I ' c� D (r C14 I NAVIX 12.07.23 JET SURVEYED: Z.NALL NAVIX 10.20.23 JET DESIGNED: J.GREEN/D.RIDDLE NAVIX 06.02.23 JET NAVIX 03.03.23 JET DRAWN: J.GREEN D.RIDDLE NAVIX 02.10.23 JET CHECKED: J.TAFLIN J.GREEN BY DATE AP P R APPROVED: J. TAFLI N SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY LEGEND - - - - PROPERTY LINE STORM DRAIN SD SANITARY SEWER SS COMBINED FIRE LINE F WATER LINE W GAS LINE GAS P ELECTRICAL LINE WET UTILITY CROSSING TABLE CROSSING UTIL 1 (1) UTIL 1 EL. UTIL 2 (2) UTIL 2 EL. DELTA C1 12" SD EL:26.02 6" SS EL:22.34 3.68' C2 12" WA EL:23.37 6" SS EL:21.63 1.74' C3 12" WA EL:26.06 12" SD EL:24.96 1.10'* C4 12" SD EL:25.41 6" SS EL:21.73 3.68' C5 12" WA EL:24.59 6" SS EL:22.13 2.46' C6 8" SD EL:26.92 12" WA EL:25.90 1.02'* C7 12" SD EL:26.66 12" WA EL:26.01 0.66'* C8 12" SD EL:26.73 6" WA EL:24.70 2.03' C9 12" SD EL:26.96 6" WA EL:25.44 4.52' C10 12" SD EL:27.00 2" WA EL:25.45 1.55' C11 12" SD EL:27.04 1" WA EL:25.51 1.53' C12 2" POWER EL:27.69 12" WA EL:25.99 1.70' C13 2" POWER EL:27.69 12" WA EL:26.03 1.66' C14 8" GAS EL:23.29 12" WA EL:21.66 1.63' (1) ALL UTILITY 1 ELEVATIONS ARE TO INVERT OF PIPE, UNLESS OTHERWISE NOTED. (2) ALL UTILITY 2 ELEVATIONS ARE TO CROWN OF PIPE, UNLESS OTHERWISE NOTED. • 18" MIN. CLEARANCE BETWEEN WA AND SS. • 6" MIN. CLEARANCE ALL OTHER CROSSINGS if O UTILITY 1 (3) *CONTRACTOR TO USE ETHAFOAM BLOCKING IF VERTICAL CLEARANCE OF 18" CAN NOT BE ACHIEVED. O UTILITY 2 (4) CONTRACTOR TO VERIFY EX. UTILITY LOCATION, DEPTH, AND ELEVATION PRIOR TO CONSTRUCTION. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. J 0 10 20 40 SCALE: 1 inch = 20 ft. NAVIX SITE I CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com 12/07/2Q23 T-426802 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING IL yqi 12/20/2023 w WEST77 PARTNERS LIVAWAY HOTEL PARK AVENUE NORTH RENTON, WA 98057 WET UTILITY CROSSINGS r 0 O 0 N LAI LO w O O O N N W ii W Z DATE: 12.07.2023 FIELDBOOK: PAGE: DRAWING N0: C-6.1 W SHEET: 0F: 32 41