HomeMy WebLinkAboutP_Atkinson Building PlansOF SCALE:9116 E SPRAGUE AVE #547 SPOKANE, WA509-928-0880LOUVERED PERGOLA CALL 811BEFOREYOU DIGOR VISITWWW.CALL811.COMSCOPE OF WORK: DESIGN & INSTALLATION OF A NEW MECHANICALLY OPENING LOUVERED PERGOLA AS DESIGNED HEREIN AT THE ADDRESS NOTED ABOVE EXCLUSIONS: THE DESIGN OF THE EXISTING HOST STRUCTURE, MECHANICAL ELEMENTS, EGRESS, WATERPROOFING ELECTRICAL, WIRING, FAN BEAMS, FANS, OR ANY ACCESSORY ATTACHMENTS ARE NOT INCLUDED WITH THIS DESIGN OR CERTIFICATION U.N.O DESIGN CRITERIA: INTERNATIONAL BUILDING CODE (2018) / WASHINGTON STATE BUILDING CODE (2018) & ASCE 7-16 LOAD COMBINATIONS 1. ROOF LOADS: DEAD LOAD........................... 2 PSF LIVE LOAD (REDUCIBLE)..................20 PSF 2.WIND LOADS: BASIC WIND SPEED.......................110 MPH EXPOSURE.................................... C COMPONENT AND CLADDING WIND PRESSURE PER ASCE 7-16 3.SEISMIC LOADS: SITE CLASS D - DEFAULT SEISMIC DESIGN CATERGORY....... D SS..............................................1.726 S1..............................................0.887 SDS...........................................1.150 SD1...........................................0.591 4.SNOW LOADS: Pg.............................................25 PSF Ps...21 PSF (ADD 5 PSF FOR RAIN SNOW SURCHARGE) Cs............................................ 1.0 Ct............................................. 1.2 SNOW DRIFT............................... PER CODE 5.RISK CATEGORY: CATEGORY...........................................II SEISMIC IMPORTANCE FACTOR...............1.00 GENERAL NOTES 1. THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE ABOVE REFERENCED BUILDING CODE. STRUCTURE SHALL BE FABRICATED IN ACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 2. THE EXISTING HOST STRUCTURE MUST BE CAPABLE OF SUPPORTING THE LOADED SYSTEM AS VERIFIED BY THE ENGINEER & OR ARCHITECT OF RECORD, et.al. THE HOST STRUCTURE WHICH IS DESIGNED, CERTIFIED, AND INSPECTED BY OTHERS MUST PROVIDE SUFFICIENT, CAPACITY FOR THIS SPECIFIED DECK SYSTEM. NO WARRANTY OR GUARANTEE TO THESE CONDITIONS, EITHER EXPRESSED OR IMPLIED, IS OFFERED WITH THIS CERTIFICATION. 3. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. ALL STRUCTURAL MEMBERS AS SHOWN HAVE BEEN DESIGNED TO CARRY IN PLACE DESIGN LOADS ONLY; THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SUPPORT OF ANY ADDITIONAL LOADS AND FORCES IMPOSED DURING MANUFACTURING, TRUCKING, ERECTING, AND HANDLING. 4. SPECIAL INSPECTIONS MAY BE REQUESTED OR REQUIRED AT THE DISCRETION OF THE AUTHORITY HAVING JURISDICTION. 4.1. IN AREAS OF SEISMIC DESIGN CATEGORY (SDC) D-F, AN INSPECTOR SHALL EXAMINE THE DESIGNATED SEISMIC SYSTEM, MOUNTING, AND ANCHORAGE REQUIRING QUALIFICATION IN ACCORDANCE WITH SECTION 13.2.2 OF ASCE 7 PER IBC 1705.12.4, AS WELL AS INSPECT REINFORCEMENT AND VERIFY PLACEMENT PER IBC 1908.4 LOUVERED PERGOLA DESIGN & OPERATION: 1. LOUVERS SHALL BE SPACED SUCH THAT THEY ALLOW 50% SYSTEM POROSITY WHEN FULLY OPENED. 2. SYSTEM NOT DESIGNED TO HANDLE CONCENTRATED LOADS FROM HUMAN ACTIVITY. 3. DURING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS A HIGH WIND OR SNOW ADVISORY FOR THE AREA, THIS SYSTEM MUST BE LOCKED IN THE OPEN POSITION, WITH THE LOUVER BLADES VERTICAL, AND ANY FANS OR ACCESSORY COMPONENTS SHALL BE REMOVED. WINDSCREENS, IF SPECIFIED, SHALL BE RETRACTED PRIOR TO WIND SPEEDS OF 35 MPH. 4. THE STRUCTURE SHALL NOT BE WALKED UPON AND IS NOT DESIGNED FOR HUMAN ACTIVITY OR STORAGE. 5. THE STRUCTURE SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR PAINTED INSTRUCTIONS TO THE OWNER OR TENANT STATING THAT (1) THE SYSTEM IS NOT DESIGNED FOR HUMAN ACTIVITY AND (2) TO REPOSITION THE LOUVERS AND WINDSCREENS DURING WIND OR SNOW ADVISORIES. THE CANOPY OWNER SHALL BE NOTIFIED OF THESE CONDITIONS BY THE PERMIT HOLDER AT THE TIME OF SALE. 6. SYSTEM SHALL BE EQUIPPED AND SOMFY CERTIFIED TO OPERATE PROPERLY WITH SENSORS WHICH WILL PROMPT THE LOUVER BLADES TO ROTATE TO THE OPEN (VERTICAL) POSITION WHENEVER THE WIND SPEED REACHES 45 MPH MINIMUM, OR TEMPERATURE DROPS TO 32° FAHRENHEIT OR LOWER, AND/OR INCLUDE THE ABILITY FOR MANUAL OPENING AND LOCKING BY THE USER. 7. LOUVERED ROOF SYSTEM SHALL BE PER MANUFACTURER MAXIMUM SPANS OR BY OTHERS. 8. NO CERTIFICATION IS OFFERED FOR WATERPROOFING, SIZING, OR OPERATION OF GUTTERS. 9. SYSTEM NOT DESIGNED FOR WATERSHED OF RAINFALL FROM ADJACENT ROOFS UNLESS SPECIFICALLY SHOWN HEREIN, TYP. STRUCTURAL MATERIALS AND CONNECTIONS STRUCTURAL ALUMINUM & ALUMINUM WELDING: 1. ALL COMPONENTS SHALL BE STRUCTURAL ALUMINUM (U.N.O.) AND SHALL BE FABRICATED AND ERECTED ACCORDING TO THE GOVERNING BUILDING CODE AND MATERIAL STANDARDS REFERENCED ON THIS SHEET. 2. ALL STRUCTURAL ALUMINUM SHALL BE MIN 1/8" THICK U.N.O. AND BE OF THE FOLLOWING ALLOY AND TEMPER: 2.1. BEAMS, PURLINS, COLUMNS ..... 6063-T6 2.2. ALL OTHER EXTRUSIONS .......... 6063-T6 2.3. FASTENERS ............................ SS 316 3. STRUCTURAL ALUMINUM SHALL BE FRAMED PLUMB AND TRUE AND ADEQUATELY BRACED DURING CONSTRUCTION. 4. ALL BEAMS SHALL HAVE A MINIMUM 1 1/2" DEPTH FULL BEARING SUPPORT UNLESS NOTED OTHERWISE. 5. WHERE ALUMINUM IS IN CONTACT WITH OTHER METALS EXCEPT 300 SERIES STAINLESS STEEL, ZINC OR CADMIUM AND THE FAYING SURFACES ARE EXPOSED TO MOISTURE, THE OTHER METALS SHALL BE PAINTED OR COATED WITH ZINC, CADMIUM, OR ALUMINUM. 6. UNCOATED ALUMINUM SHALL NOT BE EXPOSED TO MOISTURE OR RUNOFF THAT HAS COME IN CONTACT WITH OTHER UNCOATED METALS EXCEPT 300 SERIES STAINLESS STEEL, ZINC, OR CADMIUM. ALUMINUM SURFACES TO BE PLACED IN CONTACT WITH MASONRY, CONCRETE, WOOD, FIBERBOARD, OR OTHER POROUS MATERIAL THAT ABSORBS WATER SHALL BE PAINTED. 7. FOR ALUMINUM IN CONTACT WITH CONCRETE: ACCEPTABLE PAINTS: PRIMING PAINT (ONE COAT), SUCH AS ZINC MOLYBDATE PRIMER IN ACCORDANCE WITH FEDERAL SPECIFICATION TT-P-645B (“GOOD QUALITY”, NO LEAD CONTENT). ALT: HEAVY COATING OF ALKALI RESISTANT BITUMINOUS PAINT. ALT: WRAP ALUMINUM WITH A SUITABLE PLASTIC TAPE APPLIED IN SUCH A MANNER AS TO PROVIDE ADEQUATE PROTECTION AT THE OVERLAPS. 8. ALUMINUM SHALL NOT BE EMBEDDED IN CONCRETE TO WHICH CORROSIVE COMPONENTS SUCH AS CHLORIDES HAVE BEEN ADDED IF THE ALUMINUM WILL BE ELECTRICALLY CONNECTED TO STEEL. EMBEDDED ALUMINUM ELEMENTS WILL BE COVERED WITH PLASTIC TAPE OR OTHERWISE PROTECTED AS PER 2015 ADM M.7.3. 9. BOLT HOLES SHALL BE DRILLED THE SAME NOMINAL DIAMETER AS THE BOLT + 1/16". 10. ALUMINUM WELDING SHALL BE PERFORMED IN ACCORDANCE WITH WELD FILLER ALLOYS MEETING ANSI/AWS A5.10 STANDARDS TO ACHIEVE ULTIMATE DESIGN STRENGTH IN ACCORDANCE WITH THE ALUMINUM DESIGN MANUAL PART I-A, TABLE 7.3.1. ALL ALUMINUM CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE TOLERANCES, QUALITY, AND METHODS OF CONSTRUCTION AS SET FORTH IN THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING CODE-ALUMINUM (D1.2). MINIMUM WELD IS 1/8" THROAT FULL PERIMETER FILLET WELD UNLESS OTHERWISE NOTED. 11. STAINLESS STEEL FASTENERS SHALL BE ASTM F593 316 SS COLD WORKED CONDITION. PROVIDE (5) PITCHES MINIMUM PAST THE THREAD PLANE FOR ALL SCREW CONNECTIONS. ALL FASTENER CONNECTIONS TO METAL SHALL PROVIDE 2xDIAMETER EDGE DISTANCE AND 3xDIAMETER SPACING. 12. SELF-DRILLING SCREWS SHALL BE TEK BRAND / ALL POINTS FASTENERS OF SIZE #14, STAINLESS STEEL 300 SERIES, WITH MINIMUM 1/2" THREAD ENGAGEMENT BEYOND THE CONNECTED PART, UNLESS OTHERWISE NOTED. 13. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 14. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. STRUCTURAL WOOD (AS APPLICABLE): 1. ALL DIMENSION LUMBER SHALL; BE STRUCTURAL GRADE #2 SPRUCE-PINE-FIR OR BETTER, MEET ALL APPLICABLE REQUIREMENTS PER THE WESTERN WOOD PORDUCTS ASSN. (WWPA) "GRADE RULE BOOK", AND BE PRESSURE-IMPREGNATED (PT) BY AN APPROVED PROCESS (ACQ 0.4 PRESSURE TREATED) PRESERVATIVE IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE BUILDING CODE AND AMERICAN WOOD PRESERVERS ASSN (AWPA) "BOOK OF STANDARDS" OR 0.42 SPECIFIC GRAVITY MIN. 2. ALL METAL CONNECTORS IN CONTACT WITH WOOD USED IN LOCATIONS EXPOSED TO WEATHER SHALL BE GALVANIZED. 3. NAILS SHALL PENETRATE THE SECOND MEMBER A DISTANCE EQUAL TO THE THICKNESS OF THE MEMBER BEING NAILED THERETO. THERE SHALL BE NOT LESS THAN 2 NAILS IN ANY CONNECTION. 4. MEMBERS SHALL BE FREE OF CRACKS AND KNOTS. MOISTURE CONTENT SHALL BE 19% OR LESS. 5. WOOD THAT IS IN CONTACT WITH CONCRETE OR MASONRY, AND AT OTHER LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS, SHALL BE PROTECTED WITH 30 # FELT (UNLESS NOTED OTHERWISE) OR PRESSURE TREATED IN ACCORDANCE WITH AITC-109. MEMBER SIZE SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. OTHER MATERIALS (AS APPLICABLE) 1. ANY SPECIFIED LIGHT GAUGE STEEL MEMBERS SHALL CONFORM TO ASTM A36 AND CURRENT EDITION OF AISC WITH MINIMUM Fy = 36KSI 2. GLASS PANELS (IF SHOWN) SHALL BE MIN 3/8" FULLY TEMPERED GLASS & MUST COMPLY WITH ANSI Z97.1 / CATEGORY II CPSC 16 CFR 1201 AS CERTIFIED BY GLASS MANUFACTURER ANCHORS & FASTENERS 1. ALL FASTENERS TO BE #14 OR GREATER ASTM F593 COLD WORKED 304 STAINLESS STEEL, UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM-PLATED OR OTHERWISE CORROSION-RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 2. ALL METAL CONNECTORS USED IN LOCATIONS EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED. 3. ALL FASTENERS SHALL BE SPACED WITH 2x DIAMETER END DISTANCE AND 2.5xDIAMETER MIN. SPACING TO ADJACENT FASTENERS, UNLESS NOTED OTHERWISE. PROVIDE (5) PITCHES MINIMUM PAST THE THREAD PLANE FOR ALL FASTENERS. 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE ARE DEPTHS INTO SOLID SUBSTRATE AND DO NOT INCLUDE THICKNESS OF STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON-CRACKED CONCRETE ONLY. 5. ANCHOR QUANTITIES INDICATED IN DETAILS ARE FOR GRAPHICAL PURPOSES ONLY. DO NOT SCALE DIAMETER, LENGTH, OR PENETRATION(S). HEAD STYLE(S) ARE FREELY INTERCHANGEABLE. NON-STRUCTURAL ELEMENTS: 1. THE INSTALLATION OF ANY ACCESSORIES THAT DO NOT AFFECT THE STRUCTURAL INTEGRITY OF THE STRUCTURE ARE OUTSIDE THE SCOPE OF THIS CERTIFICATION AND NOT REQUIRED TO BE CERTIFIED UNDER THIS STRUCTURAL DRAWING. THEY MAY BE INSTALLED WITHIN LIMITATIONS STATED HEREIN AND AS DESIRED PER MFR. SPECIFICATIONS. DETAILS PROVIDED HEREIN ARE FOR REFERENCE ONLY FOUNDATION, CONCRETE, AND REINFORCEMENT FOUNDATION & EARTHWORK 1. SURROUNDING SOIL TO BE WELL COMPACTED BY MECHANICAL MEANS TO 90% OPTIMUM DENSITY, BE FREE OF MUCK AND ORGANICS, AND ACHIEVE 2000 PSF MIN BEARING PRESSURE AND LATERAL BEARING PRESSURE BELOW NATURAL GRADE OF 150 PSF. 2. EXCAVATIONS NEAR ADJACENT FOOTINGS AND FOUNDATIONS SHALL NOT REMOVE LATERAL SUPPORT WITHOUT FIRST UNDERPINNING OR PROTECTING THE THE FOOTING OR FOUNDATION AGAINST SETTLEMENT OR LATERAL TRANSLATION. 3. SOIL SHALL BE CLASSIFIED OR VERIFIED BY OTHERS PRIOR TO CONSTRUCTION AS SAND CLASS OR BETTER. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED THE ENGINEER OF RECORD MUST BE NOTIFIED. 4. FILL TO BE PLACED OVER THE NATURAL GROUND TO ACHIEVE THE FINISH PAD ELEVATION. BACKFILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SOILS CONTAINING LESS THAN 5% ORGANIC WITH NO MORE THAN 30% ROCK, AND NO ROCK LARGER THAN 3 INCHES IN DIAMETER AND PLACED IN LOOSE LIFTS NOT TO EXCEED 12 INCHES IN THICKNESS. ALL FILL MATERIAL FOUND AT FOUNDATION LEVEL AND BACKFILL SHALL BE COMPACTED TO 98% OF THE STANDARD PROCTOR DENSITY. CONCRETE 1. CONCRETE MIXTURES SHALL BE DESIGNED TO REACH A COMPRESSIVE STRENGTH OF 3,000 PSI IN 28 DAYS. 2. ALL MIXING, TRANSPORTING, PLACING, & CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318. 3. NO ADMIXTURES ARE TO BE USED WITHOUT THE WRITTEN APPROVAL OF THE ABOVE-SIGNED ENGINEER. 4. CONCRETE SHALL BE TYPE 1 PORTLAND CEMENT MEETING THE REQUIREMENTS OF ASTM C150, AGGREGATES TO MEET ASTM C33. POTABLE WATER SHALL BE USED. 5. SLUMP SHALL BE A MINIMUM OF 3" AND MAXIMUM OF 5" CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING SHALL BY THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. REINFORCING STEEL 1. ALL REINFORCEMENT SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A615, GRADE 60 (U.O.N.), FREE FROM OIL, LOOSE SCALE AND LOOSE RUST AND BENT, LAPPED, PLACED, SUPPORTED AND FASTENED ACCORDING TO THE "ACI DETAILING MANUAL" (SP-66) AND THE ACI 318. 2. ALL WELDING WIRE FABRIC IS TO CONFORM TO ASTM A185 MINIMUM YIELD STRENGTH OF 85 KSI. 3. CLEAR COVER FOR REINFORCEMENT SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: FOOTINGS EXPOSED TO EARTH: 3" UNFORMED FACES EXPOSED TO EARTH: 3" FORMED FACES IN CONTACT WITH EARTH: 2" SLABS NOT IN CONTACT WITH EARTH: 3/4" SLABS EXPOSED TO WEATHER: 2" BEAMS AND COLUMNS: 1-1/2" 4. ALL STEEL SHALL BE SECURELY HELD IN PLACE DURING POURING OF CONCRETE. IF REQUIRED, ADDITIONAL BARS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR TO FURNISH SUPPORT FOR ALL BARS. 5. WHEN REINFORCING STEEL IS NOTED AS CONTINUOUS REINFORCING IN SLABS, WALLS, AND/OR BEAMS, SPLICE CONTINUOUS REINFORCING STEEL ONLY WHEN UNAVOIDABLE DUE TO STOCK LENGTHS. 5.1. LAP CONTINUOUS REINFORCING A MINIMUM OF 48 BAR DIAMETERS IN BEAMS & COLUMNS, 36 BAR DIAMETERS IN SLABS. 5.2. STAGGER ALL SPLICES A MINIMUM OF FOUR FEET. ADJACENT BAR WITH SPLICES ARE NOT ACCEPTABLE. 5.3. LOCATE TOP BAR FOR SPLICES WITHIN MIDDLE HALF GO THE SPAN AND LOCATE BOTTOM BAR SPLICES AT SUPPORTS, OR BETWEEN SUPPORTS AND 1/3 SPAN POINT UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR SCHEDULES. 5.4. CONTINUITY AT COLUMNS SHALL BE PROVIDED BY CONTINUING HORIZONTAL REBARS THROUGH COLUMNS OR BY BENDING HORIZONTAL REINF. INTO COLUMNS A DISTANCE OF 30". 5.5. PROVIDE 12" STANDARD ACI HOOK MINIMUM FOR ALL DISCONTINUOUS TOP REINFORCING. 5.6. PROVIDE INTERIOR AND EXTERIOR HORIZONTAL LAPPED CORNER BARS AT ALL CORNERS TO MATCH SIZE, TYPE AND SPACING OF HORIZONTAL WALL REINFORCING IF APPLIED. 5.7. PROVIDE 2- #5 X 48" DIAGONALLY AT CORNERS OF ALL OPENINGS WIDER THAN 15". EXTEND BOTTOM BARS 8" PAST OPENINGS GREATER THAN 3'-0" ON BOTH SIDES. 5.8. 3. LAP SPLICES IN WELDED WIRE FABRIC ARE TO BE MADE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET IS NOT LESS THEN THE CROSS WIRE SPACING PLUS 3" 6. SHOP DRAWINGS SHALL BE SUBMITTED FOR E.O.R. REVIEW AND APPROVAL BEFORE INSTALLATION. 7. ALL STRUCTURAL PRECAST UNITS AND THEIR ATTACHMENTS TO THE MAIN STRUCTURE SHALL BE INSPECTED AFTER ERECTION, BUT BEFORE CONCEALMENT. SUCH INSPECTIONS SHALL BE PERFORMED BY AN ARCHITECT OR PROFESSIONAL ENGINEER REGISTERED IN THE PERMITTING STATE. CERTIFICATION & LIABILITY 1. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THE PROPOSED SYSTEM LAYOUT, COMPONENTS SELECTED, AND INSTALLATION. THESE DRAWINGS ARE NOT INTENDED TO BE USED AS FABRICATION OR SHOP DRAWINGS. 2. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT SHALL REMAIN IN CONFORMANCE WITH THE LIMITATIONS OF THIS PLAN. THE CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION, AND VERIFY THAT PROPOSED DIMENSIONS AND FIELD CONDITIONS AGREE WITH THIS PROPOSED PLAN. 3. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. THIS ENGINEERING SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 4. USE OF THIS SIGNED & SEALED DOCUMENT CONSTITUTES ACCEPTANCE OF THE PROPOSED SYSTEM LAYOUT, COMPONENTS SELECTED, AND INSTALLATION REQUIREMENTS. 5. THIS DOCUMENT SHALL NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF THE CERTIFYING P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 6. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 7. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE ONLY PERMITTED TO SHOW SITE-SPECIFIC CONDITIONS, HOWEVER ANY CHANGES, ALTERATIONS OR ADDITIONS MADE TO THE CONTENT OF THIS DOCUMENT WILL INVALIDATE THIS CERTIFICATION. 8. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED Zeyn B. Uzman, PE, SE, PEng 305 Charleston Greene Malvern, PA 19355 (217)217) 652 -2%12 BBBBBBBBBBBBBBBBBBBB 8MichaelAtkinson3401 Lake WashingtonBlvd N Renton, WA 98056 SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 100 COVER PAGE A100 TITLE SHEET NO. TOP VIEW A102 POST LAYOUT VIEW A103 SECTION 1-1 A200 NOTES DETAILS A301 DETAILS A302 DETAILS A303 PERSPECTIVE VIEW A101 FRAME: black LOUVERS: ADOBE SYSTEM: 8" BEAMS & 5.5" GUTTERS ELEVATION: ROOF SHEET INDEX presented by StruXure Washington projectMichael Atkinson address 3401 Lake Washington Blvd N Renton, WA 98056 contract no. 2109513 STRUXURE INC. 154 ETHAN ALLEN Drive dahlonega, ga 30533 DETAILS A300 DURING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS A HIGH WIND OR SNOW ADVISORY FOR THE AREA, THIS SYSTEM MUST BE LOCKED IN THE OPEN POSITION, WITH THE LOUVER BLADES VERTICAL THE STRUCTURE SHALL ALSO NOT BE WALKED UPON AND IS NOT DESIGNED FOR HUMAN ACTIVITY OR STORAGE. SECTION a-a A201 DETAILS A304 DETAILS A305 BEAM LAYOUT VIEW A104 GUTTER LAYOUT VIEW A105 FAN & LIGHTS LAYOUT VIEW A106 DETAILS A306 DETAILS A307 SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 101 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 LEGEND N.T.S. PERSPECTIVEVIEW A 1 2 B1SCALE:1/2" = 1'-0" TOP VIEW A201 A-A A201 A-A A200 1-1 A200 1-1 HOST STRUCTURE (WALL ATTACHMENT) 144" 252"SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 102 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 TOP VIEW 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0" POST LAYOUT VIEWA 1 2 B HOST STRUCTURE (WALL ATTACHMENT) 244" 248" 136"140" COLUMN 8" x 8" x 3/16"SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 103 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 POST LAYOUTVIEW 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0" BEAM LAYOUT VIEWA 1 2 B HOST STRUCTURE (WALL ATTACHMENT) SINGLE PERIMETER BEAM 2" x 8" x 18" CORNER BEAM CONNECTOR CORNER BEAM CONNECTOR SINGLE PERIMETER BEAM 2" x 8" x 18" CORNER BEAM CONNECTOR CORNER BEAM CONNECTOR SINGLE PERIMETER BEAM 2" x 8" x 18" SINGLE PERIMETER BEAM 2" x 8" x 18" DOUBLE PERIMETER BEAM (2) 2" x 8" x 18" DOUBLE PERIMETER BEAM (2) 2" x 8" x 18" 248" 138" SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 104 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 BEAM LAYOUTVIEW 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0" GUTTER LAYOUT VIEWA 1 2 B HOST STRUCTURE (WALL ATTACHMENT) 5 12" GUTTER CORNER GUTTER CORNER GUTTER CORNER GUTTER CORNER GUTTER 5 12" GUTTER5 12" GUTTER 5 12" GUTTER 5 12" GUTTER 5 12" GUTTER 71"79"8"71"8" 127" FAN BEAM 8" x 2" x 1 8"FAN BEAM 8" x 2" x 18" SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 105 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 GUTTERLAYOUT VIEW 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0" FAN & LIGHTS LAYOUT VIEWA 1 2 B HOST STRUCTURE (WALL ATTACHMENT) LED LIGHT (Non Struxure Product) SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 106 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 FAN & LIGHTSLAYOUT VIEW 1/2" = 1'-0" A B 88" SINGLE PERIMETER BEAM 2" x 8" x 18" 5 12" GUTTER LOUVER SINGLE PERIMETER BEAM 2" x 8" x 18" 5 12" GUTTER 244"HOST STRUCTURE(WALL ATTACHMENT)COLUMN 8" x 8" x 3/16" 1 SCALE: 1/2" = 1'-0" SECTION 1-1 NOTE: [SRVWV DOO DWWDFKHGWRWKHWRSRID732'(&. YLD  )XQFWLRQDO3RVW%DVH%UDFNHWSHUSRVW 252" 248" FAN BEAM 8" x 2" x 18"FAN BEAM 8" x 2" x 18" SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 200 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 SECTION 1-1 1/2" = 1'-0" 1 2 HOST STRUCTURE(WALL ATTACHMENT)1 SCALE: 1/2" = 1'-0" SECTION A-A NOTE: [SRVWV DOO DWWDFKHGWRWKHWRSRID732'(&. YLD  )XQFWLRQDO3RVW%DVH%UDFNHWSHUSRVW 144" 88" 136" COLUMN 8" x 8" x 3/16" DOUBLE PERIMETER BEAM (2) 2" x 8" x 18" 5 12" GUTTER LOUVERS SINGLE PERIMETER BEAM 2" x 8" x 18" 5 12" GUTTER 138" FAN BEAM 8" x 2" x 18" 11 GUTTER "1 GUTTER5GUTTE2GUTTR FAN B AM 8 2"1FANBEAM8x2x8 COLUMN 8 x 8 x 3/6C 555 O 11 LLL GGG UU GG M UUU MMN TTT NN TTEEE 88 EERRR xx 88 FF " AA xx AANN 33 NN / BB // BBEE 66 AA " AAMM 88 xx 22 xx 8 5 """GGGUUUUUTTTTTTTEEERR HOOD & SCREEN - BY OTHERS SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 201 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 SECTION A-A 1/2" = 1'-0" LOUVERS DETAIL SIDE VIEW ISOMETRIC OUT-SIDE VIEW ISOMETRIC IN-SIDE VIEW PIVOT BAR CAP TRACK BAR BEAM PIVOT BAR PIVOT PIN LOUVER BEAM LOUVER TRACK BAR PIN PUSH NUT TRACK BARBEAM TRACK PIN 5/16" DIA. S.S. W/ 1/2" ENGAGEMENT MIN. PIVOT BAR LOUVER PUSH NUT TRACK BAR PIN TRACK BAR #10 SS TEK SCREW @ 6" O.C PIVOT BAR CAP 6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c. 12"12"12"12" 6"1.866"0.065"SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 300 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS GUTTER CORNER ASSEMBLY ISOMETRIC VIEW CORNER BEAM CONNECTION BEAM BEAM 5.5" GUTTER 5.5" GUTTER GUTTER CORNER TOP VIEW SIDE VIEW BEAM BEAM 5.5" GUTTER GUTTER CORNER CORNER BEAM CONNECTION 5.5" GUTTER #14 TEK SCREW (2-PLACES) CORNER BEAM CONNECTION GUTTER CORNER BEAM BEAM 5.5"3"(4) #14 TEK SCREWS (2) #14 TEK SCREWS(2) #14 TEK SCREWS 6"6"1"#14 TEK SCREW 1" DOWN FROM TOP OF GUTTER EVERY 12" 5.5" GUTTER BEAM 1-7/8" LAP JOINT 1-7/8" LAP JOINT NOTE: THE GUTTER CORNER ASSEMBLY IS INSTALLED FIRST, FOLLOWED BY THE GUTTER LAPPING OVER THE GUTTER CORNER SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 A 301 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS CORNER BEAM CONNECTION PERIMETER BEAM (8) #14 TEK SCREWS TYPICAL CORNER ASSEMBLY CORNER BEAM CONNECTION (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM BEAM SIDE VIEW CORNER BEAM CONNECTION- EXTRUDED WITH CAPS BEAM SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 A 302 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS CORNER BEAM CONNECTION (8) #14 DIA. TEK SCREWS TYPICAL CORNER ASSEMBLY DOUBLE PERIMETER BEAM TO BEAM BEAM 2 BEAM 1 PERIMETER BEAM U-PROFLE TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM DOUBLE BEAM U CHANNEL 2”x1 ¾”x2”x0.125” (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE CORNER BEAM CONNECTION BEAM DOUBLE BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 A 303 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS [3] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 8" x 8" x 0.1875" POST PERIMETER BEAM [2] 2"x8" LOWER BEAM AND CHANNEL INTO POST [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO EACH BEAM 7 3/4" x 2" x 0.125 x 7 3/4" CHANNEL POST CHANNEL PERIMETER BEAM [2] 2"x8" DOUBLE BEAM TO 8X8 POST CONNECTION #14 TEK SCREWS BOTH SIDE #14 TEK SCREWS SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 A 304 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS 8X8 POST MOUNTING TO DECK BOARDSTTTTTTTTTTTTTTTTT T T T T T T T T TTTTTT TT T T T T T T T T T T T T T T T T T T T T T T T TTTTTT TTTTTTTTTTTTTTTTT T T T T T T T T TTTTTT TTTTTTTTTTTTTTTTT T T T T T T T T TTTTTT TTTTTTTTTTTTTTTTTTTTTT T T T T TTTTTTTTTTTTTTTTTTTTTT T T T T TT T T T T T T T T T T T TTTTTTTTTTTTT T T T T T T T T T T T T T TTTTTTTTTTTTTFRONT VIEW SIDE VIEW 8"X8"X0.1875" ALUM. POST DECK BOARDS 8"X8"X0.1875" ALUM. POST DECK BOARDS 2"X8" TREATED BLOCKING VERTICAL 2"X8" TREATED BLOCKING VERTICAL 2"X10" TREATED JOISTS 2"X10" TREATED JOISTS BEAM BEAM [4]516" X 4" GRK FASTENERS [2]516" X 4" GRK FASTENERS PER BLOCK [4]516" X 4" GRK FASTENERS FUNCTIONAL POST BASE BRACKET FUNCTIONAL POST BASE BRACKET SCALE SHEET NO. drawn by date description i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS 732 %<27+(56 732 %<27+(56 A 305 01/16/24MichaelAtkinson3401 Lake WashingtonBlvd N Renton, WA 98056 FOR CONCRETE ATTACHMENT: [2] 1/4" DIAM. ITW STAINLESS STEEL TAPCON INTO WALL W/ 3" EMBEDMENT AND 3" EDGE DISTANCE, SPACED 12" O.C. STAGGERED FOR WOOD ATTACHMENT: [2] 1/4" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 16" O.C. STAGGERED FOR HOLLOW CMU ATTACHMENT: [2] 1/4" DIAM. S.S. HILTI KWIK-CON II+ INTO BLOCK FACE W/ 1-3/4" EMBEDMENT AND 3" MINIMUM EDGE DISTANCE, SPACED 12" O.C. STAGGERED ALUMINUM BEAM PER PLAN 9/16" HOLE DRILLED FOR SCREW INSTALLATION 1"1"16" 32" O.C.32" O.C. 9/16" HOLE DRILLED FOR SCREW INSTALLATION TYPICAL 16" O.C. STUDS 1"1"32" O.C.32" O.C. 16"16"16" BEAM TO HOST STRUCTURE CONNECTION EXISTING HOST STRUCTURE SHALL BE EITHER 3000 PSI POURED CONCRETE, OR ASTM90 HOLLOW / GROUT-FILLED CMU OR #2 SYP WOOD (G=0.55) AS VERIFIED BY OTHERS 3" MIN.EMBED. TYPICAL ANCHOR PATTERN (TO WOOD STUDS SHOWN) HOST STRUCTURE GUTTER PERIMETER BEAM SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 306 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS FAN BEAM CONNECTION BEAM GUTTER U CHANNEL 2”x1 ¾”x2”x0.125” 7" IN LENGTH (4) #14 X 1" TEK SCREWS THRU INSERT INTO GUTTER (4) #14 X 1" TEK SCREWS THRU BEAM INTO INSERT EA. SIDE ACCESSORY BEAM BEAM INSERT BEAM GUTTER SCALE SHEET NO. drawn by date description 3401 Lake WashingtonBlvd N Renton, WA 98056MichaelAtkinson01/16/24 i&s 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533(800) 303-5248 A 307 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 N.T.S. DETAILS