Loading...
HomeMy WebLinkAboutT-425505NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. T 0 rr I- 2 N T z �0 V J z 0 I— L;.i DocuSign Envelope ID' 9MBQDAB-4385- 664-AE66-57BFFZ56ID7F v,�CKET CABIN, 10 AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK DISCONNECT 3 AMP IN LINE FUSE KITS S.E.C. OR EQUAL, ONE PER CURRENT CARRYING REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE LID STANDARD DUTY AND RECEPTACLE WIRING JUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40,10 SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS CONCRETE PAD OR SIDEWALK PER STD PLAN 120 24'(LllN) COVER #8 BARE COPPER GROUND WiRE GROUND LUG TO LUMINAIRE /TO RECEPTACLE —120VAC RECEPTACLE WIRING, IF APPLICABLE. WIRING 512E PER CONTRACT TO LUMINAIRE GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTOR. TERMINATE AT LUMINAIRE ,,.GROUND LUG Wil, WFER II GROUND, - GROUND II II NON -INSULATED #4 AWG CLAMP II II STRANDED COPPER, II PROVIDE 3' MIN. SLACK. 1 -EQUIPMENT GROUND WIRES TO PVC CONDUIT ILL_ A LUG TO I II ROUTE FROM GROUNDING WIRE W/GREEN INSULATION REBAR CONNEDCTIO FROM SERVICE CABINET, REBAR USING AN ACORN SEE NOTE 2, THHIS SHEET CLAMP 2 -LIGHTING SYSTEM 5/8"x8 COPPER CLAD CONTACTOR GROUND ROD CONCRETE FOUNDATION (SIZED AS REO'D.) 2 - 120YAC RECEPTACLE SYSTEM WIRES TO SERVICE CABINET, IF APPLICABLE (SIZED AS REQ'D.) NOTES: 1. MIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY, 2. MINIMUM GROUND WIRE SIZE SHALL BE A AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 1 EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED MRE, STIED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS. SHALL BE RUN FROM THE FIXTURE TO THE POLE GROUND LUG. 5- ALL CONDUIT SHALL BE PVC SCHEDULE 80. LUMINAIRE ELECTRICAL WIRING SYSTEM DocuSign Envelope ID: 9D9B0DA"385-4664-AE66-57BFF1561DIF f- CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 0.0 • SEE STD PLAN 126-2 FOR ADDITIONAL NOTES e PLAN VIEW SIZE TO FIT SIZE TO FIT 6 CABINET B 1 -UPI 0 ICABlNET1'-0" t ' --GRADE LEVEL FRONT VAE SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES SHIM TO PLUMB SEE NOTE 3 Q 4 HOOPS �11 4 BAR E�AC-I CORNER y �6" MEN 1 TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH V-6" + 2 1'-6" — — — — - #4 BAR EACH #4 CORNER 111 _HOOPS I!I! PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126,2 CONTROLLER CABINET FOUNDATION DocuSign Envelope ID:9D960DAB-0355.4664-AE66-57BFF1561D7F —SMALL CELL SFMD BY ONERS. SHROUD SHALL BE SEOURELY FA5TDIED TO 11E TDP Or POH.E WA b A36 STEEL P INT ECiFia�CtiS- HIJT$ HIND BOLTS, AMOUNTING DETAILS PER PALE tea- 1 V THCK Ll1tllkFER#, Pq.i, CAST ALUMINUM I v-1 WANUFACTLPWR OTHERWISE PROVIIA POLE CAP '•m BASE PLACE BASE PARTS, AND ANY AD01110RAL f��'7 ALVMIRUU S HROW EOIALL BE FACTORY ON THE POLE (BY MA?MFACTURER) �-e- 9+ALL 1� iA4CIORY PIDiAEO AND P�WDE 15'E B0.t CIRCLE COATED TO WATCH SWISH COLOR, DOME SHILL LED LWIHAIIKE (WATTAGE M 1g) 1.3e DIA_ HOLES NTH 1 1/4" • PLANS TYPE 1 IES DISTRIBUTION, 9OCGK OCT. DNA, 4 HEM HFJD COFMECT FIG ALL BA+{LtiNG AND ALL OTHER MOUNTING o -,�,LLEKIH /LUMNAIRE ARW 120-277V UNIVERSAL DRIVER C?5 A OR BOLTS ANO NUTS F RDWARt SiAti MAIU1 F3AA9i COLOR. .,d' PLANS,L8aYp2 WTH FLAT L1.�15S LENS) BY CYMONE AX (OR APPROVED EQUAL) BRIVER SMALL 9E POLE BASE PLATE DETAIL E1HI91. COLOR:. RAIL 90051x 'JET BLACK' HNTEr,SHAL TO THE FIXTURE- I M uOUNANG ARM 9-0. GR APPROVED {QUAIL MATH PAINT CHIP 7n DETAILS SEE STD RAN 117,3. WIRING PER SM PLAN 119. DECCRATW LUM[NAIRE PCLE NOES v *C 2" CONDIA1, UNLESS STATED --� OT+ERMSE ON THE PLANS. MUBOUT 1' T ROUND TUBULAR —TioN '� FRQU EDGE OF CDMCRETE (NO TAPER) AND OANEcf TO CITY Jl#€C�T0 Box 27 14' PER STD PLAN 1119_�g 04 7' CONDUIT, STUBOUT Y FROM OF E FOUONABOYI, CC J3 OF POLE SPkCE FOR Cl7k}EDGE TO N ARRIfO ORNENTED AT 90'0_ UR TYPE 1 OR TYPE Z JUKT10N BO 70� FOR LETIGIH OF PALE FOUNDATION SECTION GROUND POLE TO FOUNDA110N CONDM-% SEE FODNBAPON SECTION. PER M PLAN 119 18EYO' S2 0.--, TEa5 SME T o ANGCff BOLTS,SEE RNI]EOR BOLT }� o ASSEUITLT DETAIL, TNT$ ISMEET TOP OF COACRETE PADISMWALK 2/3 OF POLE SPACE FOR 3TY/LFALITY POLE CHAMBER DETAIL - DUNE STYLE LEO LUMINAIRE (WATTAGE PER PLANS, rYPE 3 CS DISTROUnGN. 4000K CCT. 120-277V VNIVMAL WrWM (750m4 OR LOVER), WTH FLAT GLASS LENS) BY CYCLONE (OR APPROWD EQUAQ DRIVER SHALL BE INTEGRAL TO THE FDMRE- FOR MOUNTING ARM DETAILS SEE STD PLAN 117.1 RRING PER STD PLAN 119. C-0" TER STREET uCHT STANDARD DECAL NVABERTNG DETAIL REFER TO CITY OF RERTCN SM PLAN 131 A595 GR. A. 55451. TAPERED STEEL POLE SHAFT, 35.75' LONG, O-MS' THID. 1983' 80TTOM AD., 5,80- r0P O-D. x (2) SrEEL 1' x 10' RAM HDLE WTH CQ4ER 40 NEAT HOLDER VrH FA5iENERS FCR GRDUNBING ALUWNUM BASE COVER, SEEI L.0 I R u] REBAR PER STRUCTR,AL ANALYSIS 4 �i5 1N� = x w � F� c a a 8 40' i I 180' -O' �I I �09Ic 2m FOUNDATION DETAIL ■ DECORkIIVE ROADWAY LUMINAIRES 1.3$' DLA- HOLE (TYP) ARE WONTED AT W ■ DECCRA11YE PEDEStRIAN LUMINAIRES r1- IMICK STEEL PLArE ARE YOi1RZO AT 1W �• • HANW1T1E5 ARE YOUHIED At 15T J/ BOLT ORCLF PER POLE BASE PLATE ORIENTATION LOCATIDFt DETAIL TNS SHEET STANDARD DETAIL 117.19 -B" HGH 510E1TALN OR "TER STRIP r ROVDTfAY CCNUT E PAD/SGEW&K PER ST➢ RiVi in IF 5URFACE G NOT LM. W1 TALL ObUT Al SEE F"DATION DE704L, THIS SHEET EPEE OF BASE OF POLE AND BASE COVER- PROVIDE i/;r FT]UNDA-UN OWL BE LOCATED AT LEAV 5' DIA- DRAIN TORE THRODGH GROUT AWAY MW 01-Y UTAJTIES UNLESS OTHERMASE APPROVED BY THE C'-.. tires-�. PUBLIC WORKS DEPARTMENT m m n ANCHOR�DLPLATE DETAIL IV Or F Ai ANCHOR 80lT TEMPLATE {TYp) � ANCHOR BELT, 4 1oTAe., 1 3i" pA„ STEEL f1554 OR {RJ50E 55 1 Y,' HEM NUTS (6 REDS PER ANCHOR BOLT}, AND a flAi VrA5HER5 (6 REQ'0 PER ANCHOR BOLT) ANCHOR BOLT ASSEMBLY DETAIL FOUNDATION NOTES. 1, 90ROTIJWS SHALL NOT BE ALLOWED 7- ALL FOUHDATVON HARDWAK SKAT! BE MDT -DIPPED GAL4ANIZED IN ACCOROWCE WITH THE LATEST WSDOT STANDARD SPECIFICATION 0.CROR 9-29,B(5) f4VHDATION HARDWARE ARTERIAL STREET SMALL CELL DECORATIVE LUMINAIRE POLE DETAILS LABEL THE STREET FACING SIDE OF THE CABINET WITH ADDRESS NUMBER {WIO STREET NAME) USING AN ENGRAVED PHENOLIC NAMEPLATE WITH 2" HIGH BLACK LETTERING ON WHITE BACKGROUND. ATTACH NAMEPLATE WITH ADHESIVE METER BA8E MAIM CONTROL LTG GROUND FAULT RECEPT THE METER DOOR SHALL BE REMOVABLE. UNLESS SPECIFIED IN THE PLANS, THE METER DOOR HINGE SHALL BE LOCATED ON LEFT SIDE OF THE CABINET WIRING SCHEMATIC 120/24OV, SINGLE PHASE, 3 WIRE PHOTO CELL DocuSign Envelope ID' 9139BODA8-03B5-4664-AE66-57BFF1581D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY DECAL NUMBERS/LETTERS, SEE NUMBERING EKM PLE, THIS. SHEET. SHALL BE INSTALLED IN DRY WEATHER, 50' F OR ABOVE__, 0 G 4 S 6 � NUMBERING EXgMU z N G N �a. PEDESTRIAN SCALE CURS DECAL TRAFFIC DECAL ORIENTATION FORPOLES SHOWN ON STD PLAIN 1i8.1 a• PEDESTRIAN SCALE DECAL Tcuw PEDESTRIAN SCALE DECAL TFIAFFIC TRAFFIC fL17WFLOW DECOL01111011ATW I14R F10LES 8N1511MGN SYf!li.AM ili9 TRAFFC TLDW DEAL OM MEAIIOM FOR POLES SHIM ON M PLAN 1171 A 117,1A 1i.86" - 1 ROADWAY SCALE DECK. PEDESTRIAN SCALE DECAL DE AL NOTES,- 1. DECALS SHALL BE REFLECTORIZEU, GOTHIC FONT, GOLD OR WHITE LEGEND ON BLACK BACKGROUND SCALE CALE DccuS,gn Envelope ID, FR9FD43ff-8022-4654-ABD3-E560AA1FS959 ['l M14)NEN I %A-I1L.II1 I.!. METERHASL 200 AMP.4 JAW, MANUAL BYPASS. B-LINE U264 W/ 5"' JAW AT qM0 POSITION PANELBOARD: 1201240 VAC, 125 AMP COPPER BUS, I PHASE, 3 WIRE, 18 CKT. 1 OK A€C MAiN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A. B 1 -20/1 ITS 1 - 20/1 6ROUND FAULT RECEPTACLE 1 -40/1 SIGNAL (IF PRESENT) I -40/1 AUX]LLIARY SIGNAL OF PRESENT) 2 - 50I2 SMALL CFLL HI'LANCH 1 - 1511 CONTROL 3 - 2011 SPARE CONTACTOR: iN1EMA 1AGHTING RATED, 30 AMP 4 PULE, 120 VAC C011.• SQD 89 1 ODPA34VO2 - I REQUIRED PHOTO ELECTRIC CELL: 18()G WATT, 124) VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE (:ABINET BEHIND W1REQLASS WINDOW PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK} 0 GROUND FAULT RECEPTACLE.: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2"ANULL, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LI1T-OFF TYFE),STAINLESS STEEL VAULT HANDLES WITII ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLCISFTD CELL NEOPRFNF GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: II€NGED AND SECURED WITII QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM i - REOUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKERS} SHALL BE ADDED WHEN APPLICABLE STD. PLAN - 117.1 A G � LUMINAIRE STANDARD DECAL STII. PLAN - 121 APPROVED: . PUBLIC WORKS NUMBERING SYSTEM ApP�QI'UD: . � PUBLIC WORKS 7/27/2022 1 DEPARTMENT 712712022 DEPARTMENT Mlrisl+Iin Paswrila M11rRn Paslucha '� • .. WE N DATE N ELEVATION 21' TEST SERVICE SWITCH WIREWAY 18' SECTION 3�" 72" 4U•' DEADFRONT s" pie � 2', TrP. FOOTPRINT NOTES PER STANDARD PLAN 122.2 _- CABINET FOUNDATION STD PLAN - 1281 1 CIVIL CONSTRUCTION PERMIT PUBLIC WORKS DETAILS APPIROVED: 2 CIVIL CONSTRUCTION PERMIT RESUBMITTAL DEPARTMENT' R� u 7127/2022 is.-_ _r MatFnPasiwahHe 3 CIVIL CONSTRUCTION PERMIT RESUBMITTAL lV DATE W NO. REVISION J L� 04/21 /23 SURVEYED: 07/21 /23 DESIGNED: 09/08/23 GRL/LAB DRAWN: GRL/LAB CHECKED: EMS/TDR BY DATE APPR APPROVED: EMS SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM �TENW Transportation Engineering NorthWest Transportation Planning I Design I Traffic Impact & Operations 11400 SE 8th St, Suite 200, Bellevue, WA 98004 1 Office (425) 889-6747 Project Contact: Grant Lewis Phone: 952-270-9089 CITY OF RENTON Planning/Building/Public Works Dept. SERVICE CABINET NOTES PLAN - 1222 APP OV D: MB IFl aStuCfgaf2021 1 4 1 _ DATE y5fc.•,:. STF :'DF MIA.sy''•'%'lii Ot A 52125 ?W •�.,Q! STEM`;: G\ S70NAL•�a T-425505 09-08 2023 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING -11u) CBarnes 12/04/2023 yqi 12/06/2023 -:Dl TOWNS ON 12TH 3916 & 3926 NE 12TH ST RENTON, WA 98056 ILLUMINATION DETAILS DATE: 09/08/2023 FIELDBOOK: PAGE: DRAWING NO: L-- 0 5 SHEET:OF: 79 88 X X X X X X N J X X X X X XM W T L.L