HomeMy WebLinkAboutW-425503Z ti O Z O O v PROPOSED FINISH GRADE CONTOUR EX GROUND (TYP) SEE SHEET C6.09 CONTOUR (TYP) 17425.57, 5.00' RT 74 TRACT) 1-12" 45° BEND (M✓) i (STORM DRA/NA GE) W/ CONC BLOCK/NG WA TER EASEMENT (TYP) II \ -sss- 73 I WATER BSBL (TYP) SEE SHEET I J �ao2 �� PROPOSED 17f8217, 5.00 RT 72 � T_- _ Q �\ \ - \\ STREET LIGHT 1-12 /Tf_ (FL) 06. 07 221E I F - . •. --- ___- \9 ` �' ��• (TYP) 2-12 GATE VAL l/E (FLxM✓) 12 DI TOP OF NUT 424.45 TOP OF NUT 424.47 84 -- 0 71 �� P --__ -_- -- I — 1-12"x8" REDUCER FL - I PRERTY LINE ,\ � SCALE: 1 " - 3 O' O - I �o (TYP) 1-8" GATE VAL l/E FLxM✓ • / — �\ �`, �`44 TOP OF NUT 424.12 85 = z 12 D/ W/ CONC BLOCK/NG — — 00 \\ �� \� �" rvy�22 \ . f 15f56.32, 5.00' RT \ D/ 4 1-12 "x22.5° BEND (M✓) o , � W/ CONC BLOCKING > SELF 15 �vv .. �f11.18, 5.28 RT WA TER � T2" D/ \00 ¢�! 12 �� ° — 1- 12"x22.5° BEND M✓ 17f62.51, 5.00' RT - 87 { EASEMENT l a \ — — — ' W/ CONC BLOCK/NG - 12 W TEE (MAR) SEE 70 1-6" GATE VAL I/E (FLxM✓) ° � ;;� � �; . ; s� '� TRACT H, I TOP OF NUT 421.90 SHEET a� ` 'fie. 2��o p (CR/ 17CAL AREA) FIRE HYDRANT ASS Y BTU FLANGE 425.69 69 � — � p. � , W/ CONC BLOCK/NG C6.07 ' �i \ 2 10 UTILITY OO EASEMENT FIRE HYDRANT ASSEMBLY ' 15+ � (TYP) PER C. O.R. STD DTL 310.1, 68 ° SEE SHEET C6.31 (TYP) t 66 63 N � I N C6 0 65 64 I . 62 61 60 ATC E ET 16f96.08, 28.75' L T TRACT M 16142.54, 22.33' L T 5 5EE 1-12" 45-BEND (M✓) (OPEN SPACE) 1-12" 45-BEND (MJ) W/ CONC BLOCK/NG W/ CONC BLOCKING 16f05.7 ,, 5. 00' RT STANDARD I" WATER SERVICE 12"x6" TEE (UJxFL) PER C.O.R. STD DTL 320.1, 16f 15.21, 5.00' RT 1-6" GATE VALVE (FLxM✓) SEE SHEET C6.31 (TYP) 1-12" 45° BEND (M✓) TOP OF NUT 429.75 W/ CONC BLOCKING FIRE HYDRANT ASS'Y BTU FLANGE 429.75 W/ CONC BLOCKING 436 426 416 18+50 18+00 17+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 it 17+00 16+50 16+00 1 440 i PROPOSED ELEV. F 9 ROAD � (TYP) 15+50 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N O 430 v W1v, J' vJ 420 O V, vi 4-4 410 Q SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. KEY MAP WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE—HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓) END(S) SHALL HAKE A WEDGE —TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON —POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425503 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROAD A (15+00 -END) O 0 N N N H DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.02 SHEET: OF: 50 93 CONSTRUCTION RECORD DRA WINGS